0% found this document useful (0 votes)
118 views9 pages

Calculation For Wall Anchor Bracket Project Phase 1A &1B: Data - 08 11 2020 REV 00

This document provides a structural calculation to check the adequacy of a wall anchor bracket under an applied load of 15 kN. It details the input data and codes used, then performs calculations to check the stresses in the horizontal SHS, welds, and base plate are below allowable values. The stresses were found to be acceptable in all components. Anchor selection is also considered based on the moment and shear loads transferred to the base plate.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
118 views9 pages

Calculation For Wall Anchor Bracket Project Phase 1A &1B: Data - 08 11 2020 REV 00

This document provides a structural calculation to check the adequacy of a wall anchor bracket under an applied load of 15 kN. It details the input data and codes used, then performs calculations to check the stresses in the horizontal SHS, welds, and base plate are below allowable values. The stresses were found to be acceptable in all components. Anchor selection is also considered based on the moment and shear loads transferred to the base plate.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

CALCULATION FOR WALL ANCHOR BRACKET 

PROJECT‐PHASE‐1A &1B 

Data – 08‐11‐2020 
     REV‐00 

 DOCUMENT NUMBER: STS‐P1A‐GEN‐SDW‐BMU‐GEN‐0005 
 

1. OBJECTIVE 
 
Objective of the calculation is to check whether the wall anchor bracket is 
safe under the applied load. 
 
2. CODES USED 
 BS 7985 

 
3. INPUT DATA 
Ultimate load on the anchor Fb= 15 kN (As per BS 7985: Clause 12.3.5.2)  

   

4. LOAD  

          
 

         

   
     

                                                                                                                                      1 
 
PROJECT : PHASE-1A Engineer : VIVEK___________
PROJECT NO. Verified : ASHWIN__________
Revision: 00 | Date : 08-11-2020

5.DESIGN FOR WALL ANCHOR BRACKET IN PUT OUT PUT

Steel materials safety factor

FOS : νE1  1.5

LOADS ACTING ON THE WALL ANCHOR BRACKET


Load acting on the bracket Fb  15kN (Refer page-1)

MATERIAL PROPERTIES
1)Mild Steel
Grade  S275JR
Tensile strength, yield : σEA  275MPa

Tensile strength, ultimate : σUA  430MPa

Modulus of elastisity : EA  200GPa

Max allowable stress σEA


σA1  σA1  183.333  MPa
νE1

2)Weld Electrode
Grade  E35
N
Design strength of the electrode σAE  220
2
mm

2
5.1 CHECK FOR HORZONTAL SHS
Selected SHS 75x75x6

Effective length of SHS L1  283mm

4
Moment of inertia Ix  1264300mm

Distance from nutal axis Yx  35.7mm


2
Area of cross section ASHS  1617mm

Moment on SHS M 1  Fb  L1 M 1  4.245  kN m

Bending stress on SHS M 1  Yx


σ1  σ1  119.866  MPa
Ix

Shear stress on SHS Fb


τ1 
ASHS τ1  9.276  MPa

Equivalent stress on SHS 2 2


σ1eq  σ1  3  τ1 σ1eq  120.938  MPa

Max allowable stress σA1  183.333  MPa


stress_status_1  if σ1eq  σA1 "OK" "NOT OK" 
stress_status_1  "OK"

5.2 CHECK FOR WELD

Weld thickness : thw  6mm

Weld throat thickness : thwt  0.707thw thwt  4.242  mm

2
Weld area Aw  2248mm
4
Moment of inertial of weld Ixw  4020000mm

Yw  43.16mm

Bending stress on the weld


σ2 
M1 Yw σ2  45.576 MPa
Ixw

Fb
Shear stress on the weld due to Fh τ2  τ2  6.673  MPa
Aw

Equivalent stress on weld 2 2


σ2eq  σ2  3  τ2 σ2eq  47.018 MPa

3
Design strength of weld elctrode σAE  220  MPa


stress_status_2  if σ2eq  σAE "OK" "NOT OK" 
stress_status_2  "OK"

5.3 CHECK FOR BASE PLATE

Length of base plate Lp  195mm

Plate width b P  105mm

Plate thickness t P  20mm

Ls  135mm
Bolt spacing
C1  30mm
Bending over hang

 b  t 2
Section modulus of plate
Z2 
 P P Z2  7000 mm
3
6

Area of cross section of plate


A2  b P tP 2
A2  2100 mm

Tensile force on anchors M1


Pb 
Ls Pb  31.444 kN

4
Bending stress on the plate
σ3 
Pb C1 σ3  134.762  MPa
Z2

Shear stres on the plate Pb


τ3  τ3  14.974 MPa
A2
τ3  14.974 MPa

Equivalent stress on plate 2 2


σ3eq  σ3  3  τ3 σ3eq  137.235  MPa

Max allowable stress as per EN 1808 case-1 σA1  183.333  MPa


stress_status_3  if σ3eq  σA1 "OK" "NOT OK" 
stress_status_3  "OK"

5.4 SLECTION OF ANCHORS


M b  M 1  4.245  kN m
Moment acting on base plate
Shear load
Fs  Fb  15 kN
Refer attachd hilti report

5
C-FIX 1.90.0.0
Database version
2020.9.11.10.1
Date
08/11/2020

fischer FZE

Jebel Ali Free Zone Warehouse No XB


P.O. Box 261738 Dubai

[email protected]
www.fischer.ae

Design Specifications
Anchor
Anchor system fischer Bolt anchor FAZ II
Anchor Bolt anchor FAZ II 16/25 R, stainless steel,
Property Class ≥ 70
Calculated anchorage 74 mm
depth
Design Data Anchor design in Concrete according European Technical
Assessment ETA-05/0069, Option 1,
Issued 24/04/2020

Geometry / Loads / Scale units


mm, kN, kNm

Value of design actions (including

partial safety factor for the load) Static

Not drawn to scale

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 1
C-FIX 1.90.0.0
Database version
2020.9.11.10.1
Date
08/11/2020

Input data

Design method TR055/ETAG 001, Annex C, Method A


Base material Normal weight concrete, C35/45, EN 206
Concrete condition Non-cracked, dry hole
Reinforcement Normal or no reinforcement. No edge reinforcement
Drilling method hammer drilling
Installation type Push-through installation
Annular gap Annular gap not filled
Type of loading Static or quasi-static
Base plate location Base plate flush installed on base material
Base plate geometry 195 mm x 105 mm x 20 mm
Profile type Customized profile

Design actions *⁾
# NSd VSd,x VSd,y MSd,x MSd,y MT,Sd Type of loading
kN kN kN kNm kNm kNm
1 0.00 15.00 0.00 0.00 4.25 0.00 Static or quasi-static

*⁾ The required partial safety factors for actions are included

Resulting anchor forces


Tensile action Shear Action Shear Action x Shear Action y
Anchor no. kN kN kN kN
1 28.44 7.50 7.50 0.00
2 0.00 7.50 7.50 0.00

max. concrete compressive strain : 0.34 ‰


max. concrete compressive stress : 11.6 N/mm²
Resulting tensile actions : 28.44 kN , X/Y position ( -68 / 0 )
Resulting compression actions : 28.44 kN , X/Y position ( 82 / 0 )

Resistance to combined tensile and shear loads


Eq. (5.8a)
Proof successful Eq. (5.8b)

Eq. (5.8c)

Remarks
The general and technical remarks you will find in the complete printout.

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 2

You might also like