The document provides guidelines for x-ray exposures for various anatomical regions including measurements, exam types, source-to-image distance (SID), use of grid, kilovoltage peak (kVp), and milliampere seconds (mAs) ranges. It includes exposure guidelines for regions such as skull, spine, chest, shoulder, abdomen, pelvis, upper extremity, and lower extremity. The guidelines are intended to help determine appropriate exposure factors for x-rays.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
54 views2 pages
FDR Flex QUIK MANUAL
The document provides guidelines for x-ray exposures for various anatomical regions including measurements, exam types, source-to-image distance (SID), use of grid, kilovoltage peak (kVp), and milliampere seconds (mAs) ranges. It includes exposure guidelines for regions such as skull, spine, chest, shoulder, abdomen, pelvis, upper extremity, and lower extremity. The guidelines are intended to help determine appropriate exposure factors for x-rays.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2
POWERING UP DEMONSTRATING .5.
At the Study Acquisition win-
dow, click on the “blinking” .1. Insert a freshly charged .1. Wait for D-EVO to finish its exposure menu. battery into D-EVO initialization tasks (approx. 2 minutes)
.6. MAKE SURE that D-EVO
Amber (status) and Green is “READY” (power)LEDs will illuminate .7. Make the X-ray exposure. .2. Register a patient (e.g. .2. Insert a freshly charged Patient’s Name = DEMO) battery into the Utility Box. and click “Next”
3. Power up the Utility Box
.3. Select an Anatomical Re- .8. Having acquired the image, gion and Exposure Menu demonstrate other FDX CSL (e.g. UpperExtremity, features Hand) …
Green (power) LED will
illuminate SHUTTING DOWN … and click “Start Study” .1. Shutdown the FDX CSL .4. Power up the laptop. application … .4. Position D-EVO, a phantom, and the X-ray source to acquire the image.
(the laptop will power off)
.2. Turn off the Utility Box, re-
move its battery, and insert the battery port cover. The FDX CSL application .3. Remove D-EVO’s battery, will launch. insert the battery port cover. FDR Cesium Detector PFS-0025815-B Adult Technique Guide Effective Date: 08.14.2012 Anatomical Measurement (cm) MAS Region Medium Exam SID GRID KVP Small Medium Large Skull 18 to 21 Skull PA/AP 40 Yes 80 3.6 6 8 S value 200-600 14 to 17 Skull Lateral 40 Yes 80 1.8 3.6 6 18 to 21 Skull Townes, Waters 40 Yes 85 3.6 7 12 14 to 17 Facial Bones Lat. (Bucky) 40 Yes 80 1.8 3 3.6 14 to 17 Facial Bones Lat. (Non-Bucky) 40 No 60 1 2 3 18 to 21 Nasal Bones (Non-Bucky) 40 No 60 1 2 3 Spine 11 to 14 Cervical AP/OBL 40 Yes 80 1.8 3.6 6 S value 200-600 11 to 14 Cervical Lateral 72 Yes 80 6 8 12 11 to 14 Cervical Odontoid 40 Yes 80 2.5 5 6 21 to 25 C-7/T-1 Swimmers 40 Yes 85 7 12 20 20 to 24 Thoracic AP/OBL 40 Yes 80 6 8 12 28 to 32 Thoracic Lateral 40 Yes 85 7 12 15 18 to 22 Lumbar Spine AP/OBL 40 Yes 80 7 12 20 27 to 32 Lumbar Spine Lateral 40 Yes 85 9 20 30 27 to 32 Lumbar L-5/S-1 Spot 40 Yes 90 9 20 30 Chest 20 to 25 Chest PA 72 Yes 110 1.2 2.5 3 S value 400-800 27 to 32 Chest Lateral 72 Yes 110 3.6 5 7 20 to 25 Chest Portable (Grid) 72 Yes 100 1.2 1.8 2.5 20 to 25 Chest Portable (Non-Grid) 72 No <85 1.2 2.5 3 Thorax 20 to 25 Sternum RAO 40 Yes 80 6 8 12 S value 400-800 27 to 32 Sternum Lateral 40 Yes 85 9 12 15 20 to 25 Ribs AP/PA/OBL Upper 40 Yes 70 5 7 12 20 to 25 Ribs AP/PA/OBL Lower 40 Yes 80 6 12 15 Shoulder 12 to 16 Shoulder AP 40 Yes 80 1.8 3.6 5 S value 200-600 4 to 6 Shoulder Axillary (Non-Bucky) 40 No 70 1.2 2.5 3 12 to 16 Scapula AP 40 Yes 80 3 6 10 13 to 17 Scapula Lateral 40 Yes 80 3.6 7 12 Abdomen 18 to 22 Abdomen - KUB 40 Yes 80 7 12 20 S value 200-600 18 to 22 Abdomen - Upright/Decubitus 40 Yes 85 9 15 20 18 to 22 Barium Studies (GI, BE) 40 Yes 100 8 15 20 18 to 22 Contrast Studies (IVP, GB) 40 Yes 80 8 15 20 Pelvis 19 to 23 Pelvis AP 40 Yes 80 8 12 20 S value 200-600 17 to 21 Hip 40 Yes 80 8 12 15 17 to 21 Hip X-Table Lateral 40 Yes 85 8 12 30 Upper-Extremity 1.5 to 4 Fingers 40 No 55 1 1 1 S value 150 - 400 3 to 5 Hand AP/OBL 40 No 55 1 1 2 3 to 5 Hand Lateral 40 No 55 1.2 1.8 2.5 3 to 6 Wrist AP/OBL 40 No 55 1 1 2 3 to 6 Wrist Lateral 40 No 55 1.2 1.8 2.5 6 to 8 Forearm AP 40 No 55 1.2 1.8 3 6 to 8 Forearm Lateral 40 No 55 1.2 1.8 3 6 to 8 Elbow 40 No 55 1.2 1.8 3 Humerus (Bucky) 40 Yes 75 1.8 3 5 7 to 10 (Non-Bucky) 40 No 65 1.2 1.8 3.6 Lower-Extremity 1.5 to 4 Toes 40 No 55 0.5 1 1 S value 150 - 400 6 to 8 Foot AP/OBL 40 No 55 1.2 1.8 2.5 6 to 8 Foot Lateral 40 No 55 1.2 1.8 2.5 8 to 10 Os calsis 40 No 55 1.2 3 5 8 to 10 Ankle AP - Mortise 40 No 55 1.2 1.8 2.5 8 to 10 Ankle Lateral 40 No 55 1.2 1.8 2.5 10 to 12 Tib-Fib AP 40 No 55 1.2 1.8 2.5 10 to 12 Tib-Fib Lateral 40 No 55 1.2 1.8 2.5 10 to 13 Knee AP - Lateral (Bucky) 40 Yes 80 1.8 3.6 6 10 to 13 Knee AP - Lateral (Non-Bucky) 40 No 60 1.2 1.8 2.5 10 to 13 Knee Tunnel 40 No 70 1.2 1.8 2.5 10 to 13 Knee Sunrise 40 No 70 1.2 1.8 2.5 14 to 17 Femur AP/Lateral 40 Yes 80 5 7 12 Disclaimer for filled in chart: This form can be used as a reference in the development of an exposure guide. Use the fill-in version of form to help develop a Technique Chart for each of your exposure rooms.