SPX-100/150/250B-Z Biochemical Incubator Instruction Manual First, The Instructions For Use
1. The document provides instructions for using a biochemical incubator, including how to set the temperature and timer, understand status indicators, and modify parameters during operation.
2. It also lists several matters that need attention for maintenance of the incubator, such as not inverting it more than 45 degrees, avoiding frequent changes to settings, and keeping the inside clean and dry when not in use.
3. The instructions note that the incubator has a one-year warranty period and users should not attempt repairs themselves but contact the manufacturer for any issues.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
926 views3 pages
SPX-100/150/250B-Z Biochemical Incubator Instruction Manual First, The Instructions For Use
1. The document provides instructions for using a biochemical incubator, including how to set the temperature and timer, understand status indicators, and modify parameters during operation.
2. It also lists several matters that need attention for maintenance of the incubator, such as not inverting it more than 45 degrees, avoiding frequent changes to settings, and keeping the inside clean and dry when not in use.
3. The instructions note that the incubator has a one-year warranty period and users should not attempt repairs themselves but contact the manufacturer for any issues.
1. Turn on the power, turn on the power switch, and make the switch in the “on” position, and the device enters the power-on state. At this point, the temperature and time setting operation can be started. 2. The temperature/time button can switch between temperature and time: 1) Temperature setting: Press the temperature/time button and the temperature setting indicator of the meter will light. Press the Set button to enter the SV state, set one of the three numbers in the display window to flash, then press the shift button ( < ) to shift the flashing number to the desired setting, then press the ∨ or ∧ button to change the temperature setting. Set the value to the desired temperature (minimum 0 °C), and finally press the set button to save the set value to the microcontroller. At this time, the left display window displays the measured temperature, and the right display window displays the set temperature. 2) Time setting: Press the temperature/time button, the meter's time setting indicator lights. Press the Set button to enter the TV state, set one of the three numbers in the display window to flash, then press the shift button ( < ) to shift the flashing number to the desired setting, then press the ∨ or ∧ button to change the time setting. Set the value until the required time (minimum 1h). Finally press the set button to save the set value to the MCU. At this time, the left display window displays the measurement time, and the right display window displays the set time. Timing function: When the instrument is powered, the timing function starts. After the timing is over, the output is turned off. The heater and the refrigeration compressor stop working, and the temperature inside the incubator will gradually reach the ambient temperature. 3. Status indication: After the setting is completed, the device runs according to the set parameters. When the measured temperature is lower than the set temperature, the device enters the heating state and the heating indicator lights. Conversely, when the measured temperature is higher than the set temperature, the cooling indicator lights up and the device enters the cooling state. When the measured temperature is higher than the set temperature by 4 °C, the alarm indicator lights and the buzzer sounds. 4. Parameter modification: If you want to modify the temperature and time parameters during operation, modify them according to procedures 1 and 2. 5. Quick setting: When setting parameters, one of the three numbers flashes. If you press the ∧ key, the last digit of the set value is increased by 1; if you press this button, the set value is about 3 seconds later. Add 1 continuously; if you press the ∨ key, the set value is decreased by 1; if you press and hold the key, the set value is continuously decreased by 1 after about 3 seconds. Second, matters needing attention and maintenance 1. During the handling of the incubator, it is forbidden to invert and lay flat more than 45 degrees. 2. Do not change the set value frequently during use, so as to avoid overload caused by frequent startup of the compressor and affect the service life of the equipment. 3. When there is no need for lighting in the box, the lighting switch should be placed in the "off" position to avoid affecting the upper layer temperature and prolong the life of the lamp. 4. This machine is equipped with two sets of fuses. If there is a malfunction during operation, please cut off the power supply first, check if the fuse is intact, and then check other parts. 5. In order to maintain the appearance of the device, do not wipe the surface with a corrosive solution. Wipe the cloth with a dry cloth or alcohol to keep the inside of the box clean. 6. When the equipment is not in use, keep the inside of the box dry and cut off the power. 7. To ensure uniform temperature inside the box, always check the normal operation of the axial fan in the box. During the experiment, the contents of the box should not be placed too densely and should not block the fan outlet to facilitate circulation of the airflow inside the box. 8. Do not touch, touch the temperature probe inside the box, causing the temperature to run out of control. 9. If the equipment fails, you should ask a professional to repair or contact the sales department of the factory. Users should not arbitrarily dismantle. 10. Our products implement “three guarantees”. From the date of product sale, if there are quality problems within one year, the factory is responsible for free maintenance (except for man-made damage). Exceeding the "three guarantees" period of discretionary repairs.