0% found this document useful (0 votes)
149 views1 page

Bushing Drive Sub 31766

This inspection report summarizes the results of inspecting a triple bushing top sub. The inspection included a visual inspection of the connections and body, an ultraviolet inspection of the connections, and a magnetic particle inspection of the body and connections. The inspection found that the two box connections, pin connection, and body were free of defects and acceptable for service. Dimensions of the connections were also within specification. The part was approved for continued use based on the results of the inspection.

Uploaded by

Khalil Chabbouh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
149 views1 page

Bushing Drive Sub 31766

This inspection report summarizes the results of inspecting a triple bushing top sub. The inspection included a visual inspection of the connections and body, an ultraviolet inspection of the connections, and a magnetic particle inspection of the body and connections. The inspection found that the two box connections, pin connection, and body were free of defects and acceptable for service. Dimensions of the connections were also within specification. The part was approved for continued use based on the results of the inspection.

Uploaded by

Khalil Chabbouh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 1

CUSTOMER: Weatherford INSPECTION REPORT

Work location: Weatherford base 2 SPECIFICATION: DS-1 STANDARD CATEGORY 3-5


Report N°: 0503CH18-425 X Visual Inspection connections
W.O N°:88764573 X UV Inspection connections
Page: 1 OF 1 X Visual Inspection body
Date: 25 -10- 2020 X Mag. Particle Insp body
Next inspection due date: 6 months if not use X dimension connections

DESCRIPTION : TRIPLE BUSHING TOP SUB SERIAL NUMBER : 31766 P N°: 299614

BOX PIN BOX BODY


Conn Condition CONN Condition Conn Condition
Box OD B.B/API PIN OD PIN ID
Type MPI VISUAL DIM2 TYPE MPI VISUAL DIM Type MPI VISUAL DIM2 MPI VISUAL
11 ¾ 6 5/8
8” API 6 5/8 REG OK OK OK 11 ¾” 3 9/16”
FJWP
OK OK N-A
REG
OK OK OK OK OK

INSPECTION RESULT
2 BOX CONNECTIONS COND: FREE OF DEFECT ACCEPTED
F A C L
PIN CONNECTION COND: FREE OF DEFECT ACCEPTED
Fishing Down Overall
TOP OD Neck length length BODY COND : FREE OF DEFECT ACCEPTED

11 ¾ ″ 21 ½ ″ 10 ¼ ″ 34 1/4" ACCEPTABLE FOR SERVICE AS AT THE TIME OF INSPECTION

Measuring & Test Equipment SN: Cal. Date Measuring & Test Equipment SN: Cal. Date Magnetic Particle Inspection: CONSOMMABLE
UV Light Meter 1320005430 10 10 2019 Vernier Caliper 6M0030 10 10 2019 Magnetizing Process: Continuous X Residual White contrast paint type : pfinder 280 Batch N°: L1101604

Visible Light Meter 1320005430 10 10 2019 Depth Caliper 0501111030 10 10 2019 Magnetizing Process: DC Coil
X AC Yoke X
Black magnetic ink type : pfinder250 Batch N°: L1101278

Electric Coil 176 10 10 2019 Steel Ruler N-A N-A Dry Wet X Wet fluorescent type : pfinder150 Batch N°: L1101539
MPI Technique: Particle fluorescent 0.4/100ml
AC Yoke 7973 10 10 2019 yoke test weight A 205 10 10 2019 fluorescent X visible X
consontration : black ink  2.4/100ml

Magnetic Field Strength Demagnetization: YES X NO Intensity show before visible Intensity: 1200 LUX
UV Light 180 10 10 2019 MNQ3 10 10 2019 strips
Indicator Field Indicator Type: Ac yoke/ pull 1o lbs: yes inspection Black Intensity: 1000 μ watts/cm2 min

INSPECTOR: KHALIL CHABBOUH CUSTOMER REPRESENTATIVE :