100% found this document useful (1 vote)
903 views11 pages

Censtar CNG Dispensers User Manual

This document provides information on CNG dispensers and a management system for gas stations. It includes: 1) Models and specifications of CNG dispensers for normal and heavy duty use, as well as loading/unloading dispensers. 2) Main functions, parameters, components, and brands used in the dispensers. 3) An overview of the gas station management system software, including installation instructions and a description of the main interface and its functions for equipment management, price updating, transaction details, reports, and equipment monitoring.

Uploaded by

Lidetu Abebe
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
903 views11 pages

Censtar CNG Dispensers User Manual

This document provides information on CNG dispensers and a management system for gas stations. It includes: 1) Models and specifications of CNG dispensers for normal and heavy duty use, as well as loading/unloading dispensers. 2) Main functions, parameters, components, and brands used in the dispensers. 3) An overview of the gas station management system software, including installation instructions and a description of the main interface and its functions for equipment management, price updating, transaction details, reports, and equipment monitoring.

Uploaded by

Lidetu Abebe
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

 

 
 
 
 
 
 
 

Solution and Proposal for


 
 

CNG DISPENSER
 

(For Overseas
  Project)
 

 
 

CENSTAR SCIENCE & TECHNOLOGY CORP., LTD. 
 
 
Y.2018 
CNG DISPENSER

MODEL  CSJQJ11  CSJQJ1S  CSJQJ14  CSJQJ21 CSJQJ2S CSJQJ24 CSJQJ31  CSJQJ3S CSJQJ34 
LINE  1  1  1  2  2  2  3  3  3 
NOZZLE  1  2  4  1  2  4  1  2  4 

Normal Flow Rate: 1~21kgs/min or 1~30 Nm3/min, Heavy Duty Flow Rate:1~28kgs/min or 1~40
Nm3/min

CNG LOADING/UNLOADING DISPENSER

CNG LOADING DISPENSER CNG UNLOADING DISPENSER

MODEL CSJQZD11 CSJQZD1S CSJQZD21 CSJQZD2S CSXQZD11 CSXQZD1S CSXQZD21 CSXQZD2S


LINE 1 1 2 2 2 3 3 3
NOZZLE 1 2 1 2 4 1 2 4

Loading Dispenser Flow Rate: 1~63kgs/min or 1~90 Nm3/min


Unloading Dispenser Flow Rate: 1~56kgs/min or 1~80 Nm3/min

Main Functions
 High quantity mass flow meter guarantee temperature and pressure compensation function.
 Integrated design, friendly visual and interface, reasonable structure layout and easy
operation.
 Spare interface on the IC card, Tele-Communication that can be connected with the upper
computer.
 Simple to operate, having the anti-theft program design and anti-misoperation function, and
can realize the remote control and management.
 All settings on density, unit price and mass flow meter parameter and protected with separate
mechanical seal and electronic password, which strengthen the confidentiality of key
parameters and effectively prevent the gas being stolen.
 Dispensers have perfect safety interlocking system that will stop the operation automatically
when pressure-lost, pressure-over, flow-over, signal-cut-off or the pressure transducer
breakdown.
 The red emergency stop buttons in front and back of gas dispenser can cut off the power and
stop refilling in case of emergency.
Main Parameters:
Adaptable Medium:                                                    Compressed Natural Gas(CNG) 
Max Working Pressure:                                                25 МPa 
Specified Pressure:                                                      20МPa 
Measure Accuracy:                                                      0.5% 
Repeat Measure Accuracy:                                          1/2 of Measure Accuracy 
Unit of Measurement:                                                  Kg or Nm3 
Environmental Temperature:                                      ‐25℃~55℃ 
Environmental Humidity:                                            30 ~ 95% RH 
Power:                                                                          AC220V(‐15%~10%)/50Hz(1Hz) 
Explosion‐proof Grade:                                                Exdeibmb II AT4 Gb(CNG Dispenser) 
Explosion‐proof Grade:                                                Exdeibmb II BT4 Gb(Loading/Unloading Dispenser) 

Specifications of Dispenser

NO. Part Name Material Brand Remarks

1 Mass Flow Meter stainless steel Chinese brands

2 Solenoid Valve stainless steel Chinese brands

3 One-way Valve Carbon steel Chinese brands

4 Pressure Gauge stainless steel Chinese brands

5 Pressure Transmitter stainless steel Firstrate

6 Two two-way valve stainless steel ART-LOK

7 Two three-way valve stainless steel ART-LOK

8 Safety Valve stainless steel Chinese brands

9 High-pressure Hose Polytetrafluoroethylene Tesla

10 Filter stainless steel Chinese brands

11 nozzle stainless steel Chinese brands

12 Embedded metal keyboard stainless steel Censtar

13 machine casing stainless steel Censtar


Introduction of Gas station management system Censtar

System Overview
The management system is used for the sales business management of the gas station.
This manual describes in detail the installation configuration and operation instructions of the gas
station management system. In order to help you quickly grasp the use of the system, please read
this manual carefully.

Installation of Management System Software

Step 1: Find the installer file in the installation disk and click the installer to install it;

 
Step 2: Click “下一步”

 
Step 3: Enter the installation password. Please consult the manufacturer for the password.。

 
Step 4: Select the installation target path. The default is D:\Censtar. Click “下一步” to continue the
installation. 
 

 
 
 
 
 
 
Step5:Click“下一步”to continue
 

Step 6:Click”安装”
 

Step 7: Click “完成" Successfully installed

Using of Management system

The introduction of main interface

 
CNG Manager:Setting up equipment in gas stations;

Update Price:Send the price to the dispenser;

Trade report:Query the gas station transaction details;

Summary Report:Can check the nozzle’s statistical records of a certain period of time;

The middle area is the device graphics status display area. After the device connection is complete,
Need to enter the "CNG Manager", set the dispenser information, set up, restart the system can see the

dispenser information in the "device monitoring" interface.

The software will show the corresponding dispenser's graphics

The dispenser body is gray, indicating that the dispenser is disconnected from the system。

The dispenser body is red, indicating that the communication connection is normal。

The right area is the current transaction record information

Status Bar: Displays the current version number information

Equipment Management
Device connection parameters are set through device management. The system defaults to a
nozzle, click to increase, enter the nozzle number, select the model, category, set the price, each
nozzle can be inconsistent) communication serial number, remarks information.
Note: The unit price modification is operated here. After modifying the unit price, click "Update
price" on the left and the new price will be sent to the dispenser.

Update price
Update price: The price is issued to the dispenser. After modifying the price, you need to click
"Update Price" to send the new price to the dispenser.
Transaction details
Transaction details query: You can query transaction records for a certain period of time. According
to related conditions, such as time period, nozzle number

Nozzle statistics report


Nozzle statistics report: can search nozzle statistics records for a certain period of time
Equipment monitoring
After completing the dispenser setting, the device monitor will display the graphic display of the
dispenser.

 Red is normal for communication


 Quantitative Refueling: Select the “Liter” radio button in the panel of the dispenser. Enter
the quantity in the input box below the “Liter” radio button, and then click “On” to begin
filling. When the ration is reached, the dispenser stops filling.
 Rated Money Refueling: Select the “Sale” radio button in the panel of the dispenser.
Enter the quantity in the input box below the “Sale” radio button, and then click “On” to
begin filling. When the ration is reached, the dispenser stops filling.
 Refueling without limit of parameters: Click the “On” button in the panel of the dispenser
to start filling, and click the “Off” button to stop filling.
 Reading Density: Click on the "Read Density" button in the panel of the dispenser to
read the density data from the dispenser and display it in the input box.
 Update Density: In the input box, enter the density value to be delivered. Click the
“Update Density” button in the panel of the dispenser to send the density to the refill.
 Click on the position of the nozzle on the monitoring interface, the status of the
dispenser will be displayed under the dispenser

CENSTAR SCIENCE & TECHNOLOGY CORP., LTD.

You might also like