Durable Series For data centers and mission
critical systems
DS1000B-RM/ DS1500B-RM/ DS2000B-RM/ DS3000B-RM
* Zero transfer time (online)
* Smart fan speed control
* Saves more power and minimizes noise
* 4 hours recharge time
* Cold start (DC power on)
* EPO port ready: emergency power off switch
* SNMP card slot available
* Hot swappable / replaceable battery: continuous
operation even when battery is being replaced * DS1000B-RM
* Extended battery pack (optional)
* RS232 and USB port
* Full version of OPTI-SAFE software
Specifications
Model Name DS1000B-RM DS1500B-RM DS2000B-RM DS3000B-RM
Topology True On-Line, Double Conversion
On-battery Output Waveform Sine Wave
Maximum Capacity 1000VA / 700W 1500VA / 1050W 2000VA / 1400W 3000VA / 2100W
INPUT
Maximum Capacity Single Phase (2W+G)
Nominal Input Voltage 100/110/120Vac or 220/230/240Vac
Input Voltage Regulation 80-144Vac(100/110/120Vac) or 160-276Vac(220/230/240Vac)
Nominal Input Frequency 50Hz / 60Hz Auto Sensing
Input PFC > 0.97@Full load
Input Short Protection Circuit Breaker
OUTPUT
Nominal Output Voltage 100/110/120/127Vac or 220/230/240Vac (selectable)
Output Voltage Regulation Rated Voltage +/-2%
Output T.H.D < 3% T.H.D at Linear Load
High Efficiency Mode (AC to AC) 92%
Crest Factor 3:1
Start on Battery Yes
Auto Restart Yes
6 Battery backup (US) 4 Battery backup (US)
Number of Outlets
4 Battery backup (IEC) 5 Battery backup (IEC320 10A×4, IEC320 16A×1
PROTECTION 1)
Data Line Surge Protection RJ11 / RJ45
Surge Energy Rating 125J(100/110/120Vac) ; 280J(220/230/240Vac)
Overload Protection 125% Load for 1 minutes 150% of 10 seconds(on line, 130% Load for 10 seconds >130%
Short Circuit Protection UPS output cut offf immediateiy
BATTERY
User Replaceable Battery DC36V / 12V 7.2Ah × 3 DC36V / 12V 34W × 3 DC72V / 12V 7.2Ah × 6 DC72V / 12V 34W × 6
Typical Backup Time (Full / Half load)* 6 / 18 min 5 / 15 min 6 / 18 min 5 / 15 min
Recharge Time to 90% (Typical) < 4 Hours
BP1000-RM BP1500-RM BP2000-RM BP3000-RM
Extended Battery Pack (Optional)**
12V 7.2Ah × 6 12V 34W × 6 12V 7.2Ah × 12 12V 34W × 12
ADVANCED WARNINGS / DIAGNOSTICS
Front Panel LEDs AC mode / On line / On battery / Bypass / Fault / Overload and 15 UPS Parameters
Audible Alarms Battery mode / UPS faults / Overload
COMMUNICATION INTERFACE
Communication Port RS232 and USB#
SNMP Manageable Yes
ENVIRONMENTAL
Operation Temperature 0~40°C / 32~104°F
Storage Temperature -20~60°C / -4~140°F
Relative Humidity 0~95% humidity, non-condensing
Audible Noise < 40 dBA (at 1 meter from surface of unit)
PHYSICAL
Dimensions (Physical / Packing) (in) 16.9×16.7×3.3 / 21.7×21.5×8.1 25×16.9×3.3 / 29.5×21.7×8.7
(LxWxH) (mm) 428×425×84 / 552×546×206 635×428×84 / 750×550×220
Weight (Net / Gross) (lbs) 40.1 / 47.4 40.6 / 47.8 69.7 / 74.5 71.6 / 78.7
(kg) 18.2 / 21.5 18.4 / 21.7 31.6 / 33.8 32.5 / 35.7
Battery Pack Dimensions (in) 16.7×16.9×3.3 / 21.5×21.7×8.1 25×16.9×3.3 / 29.5×21.7×8.7
(LxWxH) (mm) 425×428×84 / 546×552×206 635×428×84 / 750×550×220
Battery Pack (Net / Gross) (lbs) 48.7 / 53.1 94 / 101.7
(kg) 22 / 24 42.5 / 46
CONFORMANCE
Approvals UL / cUL(1X0V) ; CE , A-Tick , C-Tick , GOST-R(2X0V)
CS 73 0B
Specifications are subject to change without notices.
* Typical backup time depends on power consumption of equipment attached and on UPS battery capacity. Values here are for reference only.
** The external battery pack is optional. Battery pack needs to be connected to UPS before connecting any load and turning on the UPS.
# The model with optional USB port provides both RS232 and USB connectivity, but only one connectivity can be used at the same time.
34.
Standby UPS Line Interactive On-Line UPS Stabilizer Inverter Series Surge Series Power Storage Networking
Series UPS Series Series Series Series Series
Durable Series For data centers and mission
critical systems
DS1000B-RM/ DS1500B-RM/ DS2000B-RM/ DS3000B-RM
Front Panel
DSB-RM
1 Func
2 Enter
3 On/ Off
1 2 3
Rear Panel
DS1000B-RM/ DS1500B-RM
9 3 1 3
6 8 6 8
1 5 2 5 4
2 4
7 7
100V / 110V / 120V 220V / 230V / 240V
DS2000B-RM
9 4 2 10 3 4
3 6 5 6
1 5 8 8
1
2 1
7 7
100V / 110V / 120V 220V / 230V / 240V
DS3000B-RM
10 4 9 3 4
2
3 6
5 6 5
1 8 8
11
1
2 7 1 7
100V / 110V / 120V 220V / 230V / 240V
1 Battery Backup Outlets
2 Input
3 Data Line Protection
4 USB
5 Extended Battery Connector
6 RS232
7 EPO
8 Smart Slot
9 Circuit Breaker
10 Input Circuit Breaker
11 Output Circuit Breaker
CS 73 0B