MAKING MODERN LIVING POSSIBLE

INT

Danfoss Link™ FT
Floor Thermostat
Installation Manual

Danfoss Heating
Danfoss Link™ FT

The Danfoss Link™ FT (Floor Thermostat) is a device for


switching the heating element ON/OFF.
In connection with a floor sensor it can also measure the
temperature in the floor (FTS). Secondly you have the
possibility to use the FT as a on and off switch to other
equipments manually or by schedule.

Installation scenario:

Danfoss Link™ RS

22.0
22.0

ed
geriv
055™

devireg™550

Danfoss Link™ FT

Danfoss Link™ CC

LED
Push and hold
for 5 sec. to
install/connect
ON/OFF
safety switch

2
Placement of Danfoss Link™ FT

Installation and placement must be according to local


building regulations.

Operation mode
Danfoss Link™ FT supports two types of operation modes.
1. Heating regulation
2. On/OFF switching

When used in heating regulation mode you have to consider


the following advices for controlling the heating.
When used as simple ON/OFF mode do not connect floor
sensor.

Sensor combination
When installing the Danfoss Link™ FT you need to consider
the type of heating and thus which sensors should be used.
There are three options:

1. Comfort heating: Constant temperature on the floor in


bathrooms and other rooms where a comfortable warm
surface is required. Install the Floor sensor and choose
Floor regulation for the room when doing the configura-
tion.
2. Total heating: Control of room temperature in living
rooms etc. Install the floor sensor and a Danfoss Link™ RS.
Choose Combined regulation when doing the configura-
tion on the Danfoss Link™ CC.
3. No floor sensor: A floor sensor is not present, and cannot
be installed. You must install a Danfoss Link™ RS. Choose
Room regulation.

3
Placement of Danfoss Link™ FT

Be aware that temperature control is less accurate without


the floor sensor and that all Danfoss Link™ FTs in a room need
to havethe same sensor configuration.

Danfoss recommends always installing a floor sensor.

Do not install floor heating system without a floor sensor


when the heating element is installed on or beneath
wooden surfaces and other surfaces
sensitive to temperature!

4
Installation of Danfoss Link™ FT

Installation of Danfoss Link™ FT


1. To remove the front cover, gently press the release tabs
under the bottom of the thermostat with a screwdriver.
Then remove the front.

20
15 25

30

35

2. Connect the thermostat according to the connection


diagram.

Configuration:
See Step-by-Step guide in Danfoss Link™ CC instruction
manual.

5
Trouble shooting

Green LED ON Standby


Red LED ON Heating
Green LED fast flash Inclusion or link test
Red LED short flash Inclusion not OK, goes to not
included.
Linktest not OK, goes to
missing link
RED LED slow flash Sensor failure

Factory reset a Danfoss Link™ FT


Turn off power on the safety switch on the front. Hold the
install button in while pushing ON the safety switch and
keep the install button pressed until the LED gives a red flash
(approx. 5 sec.)

6
Disposal Instruction

7
Technical specifications

Operation voltage 180-250 VAC, 50/60 Hz


Standby power
Max. 1 W
consumption
Relay:
• Resistive load 230 V ~ 15 A / 3450 W
• Inductive load cos ϕ = 0.3 Max. 4 A
Sensing unit NTC 15kOhm AT 25°C
Sensing values:
• 0°C 42 kOhm
• 20°C 18 kOhm
• 50°C 6 kOhm
Regulation PWM
Ambient temperature -10° to +30°C
The thermostat has a built-in
monitoring circuit, which
Sensor failure
will switch off the heating if the
monitoring
sensor is disconnected or short-
circuited
Transmission
868.42 MHz
frequency
Transmission range in
Up to 30 m
normal buildings
Transmission power Max. 1 mW
IP class 31
Dimensions 85 mm × 85 mm × 21 mm

8
9
The 2 Year Danfoss Warranty

You have purchased a Danfoss heating An extension of the warranty period


system which we are sure will serve to following repairs undertaken under
improve the comfort and economy of warranty cannot be granted.
your application. The Danfoss Warranty shall not
cover any damage caused by
Danfoss provides superior electrical incorrect conditions of use, incorrect
heating solutions for total climate installation or if installation has
control in and around homes and been carried out by non-authorised
buildings. Danfoss offers a complete electricians. All work will be invoiced
product program with Danfoss in full if Danfoss is required to inspect
heating cables or Danfoss heating or repair faults that have arisen as a
mats, Danfoss thermostats, Danfoss result of any of the above.
selflimiting heating cables combined
with additional products completing The Danfoss Warranty shall not extend
the product program. to equipment which has not been
paid in full.
This 2 year warranty applies to all
Danfoss products. Danfoss will, at all times, provide a
rapid and effective response to all
Should you, against all expectations, complaints and inquiries from our
experience a problem with your customers.
Danfoss product, you will find that
Danfoss offers a 2 year warranty from The warranty explicitly excludes
the date of purchase on the following all claims exceeding the above
conditions: conditions.

During the warranty period Danfoss


shall offer a new comparable
product or repair the product in
case the product is found to be
faulty by reason of defective design,
materials or workmanship. Repair
or replacement shall be carried out
at Danfoss’ discretion. Danfoss shall
not be liable for any consequential
or incidental damages including, but
not limited to, damages to property or
extra utility expenses.
This warranty shall only be valid on
production of proof of purchase and
must be submitted to the installer or
seller without undue delay.

10
The 2 Year Danfoss Warranty

Warranty Certificate
The Danfoss™ Warranty is granted to:

Name:

Address

City: Country: Telephone:

Attention:
The Warranty Certificate must be completed correctly for the Warranty to be valid.
Please read the Warranty conditions above.

Type of thermostat: Electrical installation by:

Article number: Date:

Suppliers Stamp:

11
Article No.: 088L8083
Version - 02.01

Danfoss A/S
DK • 7100 Vejle
Phone +45 7488 8500
Fax +45 7488 8501

Danfoss Heating Solutions VISGZ102 © Danfoss 09/2009

You might also like