EARTHCON SYSTEMS (I) Pvt. Ltd.
An ISO 9001: 2015 Company
D-40 Okhla, Phase 1, New Delhi 110020 web: www.esipl.net
e-mail:
[email protected] RSW Fascia Panel RCC Design
C/o approaches for construction of RE wall for Dimapur Bypass
(Assam Portion) of 4/6 Lane pavement on EPC basis from
Existing KM 159.400 of NH-36 to Existing KM 102.500 of
NH-39 and upto end point Assam Portion in the state of Assam,
under phase-A of SARDP-NE.
PANEL-A
Project: Construction of RE wall for Dimapur Bypass(Assam
Portion) of 4/6 Lane Pavement on EPC basis in the state of Assam,
under Phase-A of SARDP-NE.
Client : National Highways & Infrastructure development Corporation Ltd.
Design Consultant : Accerete Consulting Engineers Pvt. Ltd.
Authority Engineer:M/s Yongma Engg. Co. Ltd. in association with M/s
Sterling Indo Tech consultant Pvt. Ltd.
Proof Consultant: Sparsh Engineering company Pvt. Ltd.
EPC Contractor: M/s Gawar-Singh(JV).
RE Walls Surface Erosion Control Ground Improvement Geo-synthetics’ Applications
Calculations For Panel Reinforcement
Panel Concrete Grade fck 35 MPa
Steel Fe fy 500 MPa
Panel Type A
Panel Thickness 180 mm
Clear cover to any reinf. 55 mm
Effective depth for Vertical Reinf. 121 mm
Effective depth for Horizontal Reinf. 113 mm
Panel Thk. is 180mm and vertical soil reinforcement is placed close to inside face.
Maxm UTS of Geostrap in Vertical plane & Horizontal plane 75 kN
Maxm force in one leg of Geostrap 41.41 kN
Maxm force at each connection point 82.82 kN
(material reduction factors used 1.15, 1.03 and 1.39 and fn 1.1)
maxm force is calculated by using material factors
pl note that this is ULS force
Total force on the four connection points 331.29 kN
Panel Height 1.585 m
Panel Width 2.000 m
The effective panel size is 1.585m x 2.000m, area is 3.170 sqm
UDL on face of panel (w) assuming uniform distribution 104.5 kN/m2
2000
385
Arrangement of
cavity on the back
800 450 900 face of the panel.
Each Line Load
carries a force of 2F.
400
As can be seen, the panel shall bend in both the planes.
Reinforcement in the Horizontal Plane:
Maxm Bending moment in the cantilever = w l^2/2 10.58 kNm/m
= 1.710 tm for panel ht.
2
Mu/bd 0.829 Mpa
Steel Required as per IRC112 = Fe500 221.5 mm2/m
for 1585mm high panel, total required 351 mm2
Steel Provided 8 no. 8mm dia. 402 mm2
Total reinforcement provided 402 mm2 Safe
Reinforcement in the Vertical Plane:
Maxm Bending moment in the cantilever = w l^2/2 8.36 kNm/m
= 1.705 tm for panel width
Mu/bd2 0.571 Mpa
Steel Required as per IRC 112 = Fe500 176.2 mm2/m
for 2000 mm wide panel, total required 352 mm2
Steel Provided 10 no. 8mm dia. 503 mm2 Safe