This document contains 7 questions related to the design of reinforced concrete columns. The questions involve calculating reinforcement quantities for columns subjected to axial loads and bending moments. Designs are to be done using column design charts and assuming C-25 or C-30 concrete and S-400 or S-300 steel reinforcement. Columns have specified dimensions ranging from 300x300mm to 500x500mm. Reinforcement quantities are to be determined to resist axial and moment loads from pinned or fixed end conditions. Non-sway and sway frame conditions are also addressed. Solutions are to be submitted by May 31, 2019.

Uploaded by

Dechas Mohammed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
204 views2 pages

Assignment 2

This document contains 7 questions related to the design of reinforced concrete columns. The questions involve calculating reinforcement quantities for columns subjected to axial loads and bending moments. Designs are to be done using column design charts and assuming C-25 or C-30 concrete and S-400 or S-300 steel reinforcement. Columns have specified dimensions ranging from 300x300mm to 500x500mm. Reinforcement quantities are to be determined to resist axial and moment loads from pinned or fixed end conditions. Non-sway and sway frame conditions are also addressed. Solutions are to be submitted by May 31, 2019.

Uploaded by

Dechas Mohammed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Jimma University

Jimma Institute of Technology


Department of Civil and Environmental Engineering
Reinforced Concrete Structure II (CENG – 3101)
Assignment – II (15%), Group Task

1. A pin ended columns as shown in Fig. 1 is supposed to support order moment of 145 kN.m and -120kN.m. Assume square cross
an unfactored dead load and live load of 300kN and 450kN section of 300mm, length of column=5.5m, 𝐿𝑒 = 0.66𝐿 . Use
respectively. Assume that the axial load is acting at the centroid C-25 concrete and S-400 steel bar.
of the column section, design the longitudinal reinforcement. Use 5. A column is constructed from C-30 and S-400 material, class I
C-25 concrete and S-400 steel bar. In addition, consider column work. If the diagram for first order end moments and axial forces
size of 400x400mm and class I work. as obtained from analysis are shown in Fig. 2.. Determine the
quantity of reinforcement required by assuming non sway frame
system. Use a rectangular cross section having b/h dimension of
300mm/400 mm & 𝐿𝑒 = 0.7𝐿 .

4.50m 1400kN
150kN.m

Fig. 1 Pin ended braced column 6.00m


2. A square column with 350 mm cross sectional dimension sustains
design moment 𝑀𝑢 = 70 kN. m to one orthogonal direction
with additional axial load of 𝑁𝑢 = 500kN. If the materials
used are concrete C-25, S-400 class-I works, determine the
quantity reinforcement for the given condition. 90kN.m
3. A rectangular column, 300x500mm is subjected to a factored
1200kN
design load of 1380KN and first order moment of 𝑀𝑥𝑥 =
135kN. m and 𝑀𝑥𝑥 = 60kN. m. If the martial properties of
Fig. 2 Column to be designed for Q.5
C-30 and S-300, and class-I works are used and the second order
eccentricity is neglected in both directions,
a. Design this column using column design chart.
(Use 𝐿𝑒𝑥 = 𝐿𝑒𝑥 = 4𝑚)

4. Calculate the quantity of reinforcement required in slender


braced column to resist a compressive force of 1400kN and first

Note:
 Submission date: May 31, , 2019
 Assume additional data needed for the design by yourself
 Show reinforcement detailing clearly
 Any sort of duplicated works are strictly prohibited and for sure it will be revoked.
By: Kefiyalew Z. ( M.Eng) 3rd Year/Group-3/
6. Suppose a total factored load including self-weight of beam is 7. Fig.4 shows a non-sway frame with 𝐿𝑒 = 0.7𝐿 supporting a
acting on a non-sway system with 𝐿𝑒 = 0.7𝐿 as shown in total factored uniform load of 60 KN/m. Design longitudinal
Fig.3. The moment of inertia of the beams have found to be twice reinforcement for all the columns. The dimension of the
that of the columns for architectural reasons. The dimension of columns is restricted to 300mm × 300mm for architectural
the columns is restricted to 500mm ×500mm for architectural purpose. Take the materials used are concrete C-30, S-400 class-
purpose. If the materials used are concrete C-30, S-400 class-I I works.
works,
a. Design column between axis 1B & 2B using column
design chart

30kN/m
3

3.6m
40kN/m 50kN/m
2
4.0m
1 Fig. 4 Frame system for design of Colum for Q.7
A B C
5.0m 5.0m
Fig. 3 Frame system for design of Colum between
axis 1B & 2B for Q.6

Note:
 Submission date: May 31, , 2019
 Assume additional data needed for the design by yourself
 Show reinforcement detailing clearly
 Any sort of duplicated works are strictly prohibited and for sure it will be revoked.
By: Kefiyalew Z. ( M.Eng) 3rd Year/Group-3/

You might also like