Assignment 2
Assignment 2
1. A pin ended columns as shown in Fig. 1 is supposed to support order moment of 145 kN.m and -120kN.m. Assume square cross
an unfactored dead load and live load of 300kN and 450kN section of 300mm, length of column=5.5m, 𝐿𝑒 = 0.66𝐿 . Use
respectively. Assume that the axial load is acting at the centroid C-25 concrete and S-400 steel bar.
of the column section, design the longitudinal reinforcement. Use 5. A column is constructed from C-30 and S-400 material, class I
C-25 concrete and S-400 steel bar. In addition, consider column work. If the diagram for first order end moments and axial forces
size of 400x400mm and class I work. as obtained from analysis are shown in Fig. 2.. Determine the
quantity of reinforcement required by assuming non sway frame
system. Use a rectangular cross section having b/h dimension of
300mm/400 mm & 𝐿𝑒 = 0.7𝐿 .
4.50m 1400kN
150kN.m
Note:
Submission date: May 31, , 2019
Assume additional data needed for the design by yourself
Show reinforcement detailing clearly
Any sort of duplicated works are strictly prohibited and for sure it will be revoked.
By: Kefiyalew Z. ( M.Eng) 3rd Year/Group-3/
6. Suppose a total factored load including self-weight of beam is 7. Fig.4 shows a non-sway frame with 𝐿𝑒 = 0.7𝐿 supporting a
acting on a non-sway system with 𝐿𝑒 = 0.7𝐿 as shown in total factored uniform load of 60 KN/m. Design longitudinal
Fig.3. The moment of inertia of the beams have found to be twice reinforcement for all the columns. The dimension of the
that of the columns for architectural reasons. The dimension of columns is restricted to 300mm × 300mm for architectural
the columns is restricted to 500mm ×500mm for architectural purpose. Take the materials used are concrete C-30, S-400 class-
purpose. If the materials used are concrete C-30, S-400 class-I I works.
works,
a. Design column between axis 1B & 2B using column
design chart
30kN/m
3
3.6m
40kN/m 50kN/m
2
4.0m
1 Fig. 4 Frame system for design of Colum for Q.7
A B C
5.0m 5.0m
Fig. 3 Frame system for design of Colum between
axis 1B & 2B for Q.6
Note:
Submission date: May 31, , 2019
Assume additional data needed for the design by yourself
Show reinforcement detailing clearly
Any sort of duplicated works are strictly prohibited and for sure it will be revoked.
By: Kefiyalew Z. ( M.Eng) 3rd Year/Group-3/