COSMED Stress ECGs

Choose the best product according to required features and purpose of use.
Call +39 (06) 931-5492 (International) or +1 (773) 645-8113 (US only) for additional information

Product /Comparison Matrix

Features Quark C12x Quark T12x


PC interface Cable (USB 2.0) Telemetry (Wi-Fi)

Type of product 12-leads Stress PC-ECG

Number of electrodes 10 AHA / IEC


Acquisition Simultaneous 12-leads (I,II,III, aVR, AVL, aVF, V1, V2, V3, V4, V5, V6)
Sampling Rate 16.000 samples/sec (maximum)
Defibrillator protection to 360J

Amplifier integrated into patient cable


CMRR >100 Db
Frequency range 0.05 - 300 Hz
Patient leakage current <10 μA
Input impedance >100 Mohm
Pacemaker detection From 0.1 to 2ms to 2-700mv
TTL Output for external HR trigger ❍ ●

Communication USB cable Digital Radio Frequency


Radio frequency range (Auto-select) 2400 - 2483.5 Mhz
Radio frequency output power 0.4 mW
Maximal operational distance ~ 10 m
Weight 300 gr 350 gr

Dimensions 17x9x3 cm 16x10x4.5 cm

Power supply Via USB (5V) Battery (4 AA Alkaline Or NiMh Rechargeable)


Power consumption < 200 mA ± 10%

E & OE. Subject to alterations without prior notice. Part-No.: C03511-02-93


Software Quark C12x Quark T12x
User defined exercise protocols Bruce, Balke, Ellestad, Kattus and USAFSAM

User programmable protocols ●

Patient database with demographics ●

Languages EN, FR, ES, DE, NL, IT

Display mode 3x4 / 6x2 / 12 leads with or without other parameters

Export formats HL7, XML, JPEG, GDT, PDF, DICOM

Network compatibility ●

Tests Quark C12x Quark T12x


12-leads Stress ECG ●

12-leads Resting ECG ●

ECG interpretation (Resting) ●

Arrhythmia analysis with stress ●

Full disclosure ECG analysis ●

Scroll-back analysis ●

ST segment (ST Segment depression, ST slope, J point, isoelectric identification)


© 2010/12 COSMED

Medians Complexes ●

Heart rate variability ❍

Blood pressure ❍

Estimation of Oxygen uptake / METs ●

Automatic control of ergometers ●

Integration with COSMED Gas Exchange Equipment ●

● Standard ❍ Option

Via dei Piani di Monte Savello, 37 - Rome - I-00041 Italy