Aspirating Fire Detection

Protec
Protec Fire Detection plc
Cirrus Pro 200D

• Cloud Chamber Detection Principle

• Upto 200 mtrs Sampling Pipe

• Programmable ‘Pre-Alarm’ warning


condition

• 3 Programmable ‘Fire’ warning conditions

• Local Buzzer

• Silence and Reset Buttons

• Vast Sensitivity Range (incipient to


conflagrating)

• Latching / non latching alarm contacts

• Airflow Monitoring

• ‘Fault Diagnostic’ feature

• Immune to dust, humidity & temperature


UL

changes
/F
M

CLOUD CHAMBER FIRE DETECTOR ALMOST UNLIMITED APPLICATIONS

The ‘sensitivity range’ is the key feature High Sensitivity Applications include:-
that makes the Cirrus Pro Series Fire Computer Rooms, Clean Rooms, Control
Detector the worlds most versatile fire Rooms, Data Centres, Valve Halls, Archive
detection device. Storage, Anechoic Chambers, EDP areas.

For over 20 years Cloud Chamber detectors General Sensitivity Applications include:-
have been known as the most sensitive Historic Buildings, Museums, Hospitals,
fire detection device, able to detect at the Cathedrals, Theatres, Art Galleries, Clean
true incipient stage of a developing fire. Warehouses, Atria, Indoor Stadiums.

The New Cirrus Pro Series Detectors Harsh Environment Applications


have a vast sensitivity range capable of include:- Cold Storage Facilities,
being even more sensitive than previous Specialist Production Facilities, Food
versions. In addition the detector may Industry Facilities, Paper Production
now be configured to be installed in Facilities, Transportation Terminals, Flight
heavily contaminated environments, such Simulators, Aircraft Hangers, Prisons,
as polluted production and warehousing Inaccessible Voids, Dirty Warehouses.
facilities.

A D D R ESS IN G S A F E T Y SYST E M S W I T H I NT E L L I G E N CE
Aspirating Fire Detection

Technical Specification

Connections Dimensions (mm)


25mm Sampling Pipe 360 15
125

RS485 Pre-Alarm Output

Input 1 Fire 1 Output

Input 2 Fire 2 Output

215
Input 3 Fire 3 Output

Input 4 Common Fault Output


Supply Fault
24V
0V

360 15
125
4
9000 Series BC Charger
215

240V AC Mains Supply

Technical Specification:
Supply Voltage 20 - 29VDC Alarm Indications Pre-alarm, Fire 1, Fire 2, Fire 3.

Power Consumption 10 watts quiescent Programmable Inputs 4 monitored inputs that may be configured
for Isolate, Reset, Disable, Fault, Gain Set,
Current Consumption 416mA quiescent 585mA alarm
Battery Fault and Mains Fault.
Dimensions (W) 360mm, (H) 215mm (D) 144mm
Programmable Output Relays 5 Relays rated 1A @ 30VDC
Weight 5kg (11lbs) (Volt-free change over contacts)

Operating Conditions Event Log 128 events stored on FIFO basis


Detector Ambient 0˚C to 38˚C (32˚F to 100˚F) Data Retention Approx 10 day historical graph.
Tested to 0˚C to 55˚C (32˚F to 131˚F)
Sampled Air -20˚C to 60˚C (-4˚F to 140˚F) Variable Sensitivity Settings 7 day programmable settings with 3 time
Humidity 10 - 95%RH, non-condensing zones per day.

IP Rating IP30 Multi-function Display


/Programmer Cirrus Pro 200D incorporates a quarter
Cable Access 6 x 20mm knock outs VGA backlit LCD. In normal conditions the
Date, Time, Detector Text and particle
Cable Termination Screw terminal blocks
Levels are all displayed. Alternatively any
(0.2 - 2.5mm2, 30 - 12AWG)
Fault, Pre-Alarm or Fire conditions will be
Sampling Network Single inlet port with combined displayed. Event Logs, ‘Historical’ and
sampling pipe length up to 200m ‘Real Time’ graphs may also be displayed.
typically (650ft.) Maximum Transport The LCD display is also used in conjunction
Time allowed up to 120 seconds. with the programming keys to commission
each unit without need for a computer link.
Pipe ID 19 to 25mm (preferred OD 25mm)
Airflow Monitoring High Airflow’ and ‘Low Airflow’ fault
Sensitivity Range 20,000 particles per cc to 3 million
monitoring.
particles per cc 10 programmable
sensitivity ranges.

Company Policy is one of continuous improvement, we reserve the right to change specification without prior notice