Cathodic Protection Design of Pipelines: Pipeline Information

This document provides calculations for designing an impressed current cathodic protection system for a 50 km long pipeline. It calculates the required current output, number of anodes, and dimensions for a vertical ground bed based on parameters like pipeline length and diameter, coating effectiveness, current density, anode properties, and safety factors. The design calls for 10 anodes in a vertical ground bed 45 meters in total length to provide the necessary 14.956 amps of current to protect the pipeline.

Uploaded by

mtuanlatoi9704
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
551 views

Cathodic Protection Design of Pipelines: Pipeline Information

This document provides calculations for designing an impressed current cathodic protection system for a 50 km long pipeline. It calculates the required current output, number of anodes, and dimensions for a vertical ground bed based on parameters like pipeline length and diameter, coating effectiveness, current density, anode properties, and safety factors. The design calls for 10 anodes in a vertical ground bed 45 meters in total length to provide the necessary 14.956 amps of current to protect the pipeline.

Uploaded by

mtuanlatoi9704
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Impressed Current Cathodic Protection Design for Pipelines

Cathodic Protection Design of Pipelines


Impressed Current CP Design Calculation
DATA DESCRIPTION:
INPUT VALUES: CALCULATION OUTPUT:
<-> Pipeline Information:
Total Pipeline Length, L (Km) L ≔ 50 km L = ⎛⎝1.969 ⋅ 10 6 ⎞⎠ in
Pipeline Diameter, D (mm) D ≔ 42 in
Pipe Thickness, t (mm) t ≔ 13 mm
Coating Effectiveness, (%) Ci ≔ 95% D ⋅ L ⋅ π = ⎛⎝2.597 ⋅ 10 8 ⎞⎠ in 2
Surface Area of the Pipeline, A (m^2) D ⋅ L ⋅ π = ⎛⎝1.676 ⋅ 10 5 ⎞⎠ m 2
Ab ≔ D ⋅ L ⋅ π ⋅ ((1 - Ci))
Ac ≔ D ⋅ L ⋅ π ⋅ Ci Ab = ⎛⎝8.379 ⋅ 10 3 ⎞⎠ m 2
Ac = ⎛⎝1.592 ⋅ 10 5 ⎞⎠ m 2
<-> Current Density:
mA
Current Density, i mA/m^2 ic ≔ 0.01 ――
Current Demand, I (Amp) m2

mA
ib ≔ 1.0 ―― Ic ≔ ic ⋅ Ac = 1.592 A
m2 Ib ≔ ib ⋅ Ab = 8.379 A
I ≔ Ic + Ib = 9.971 A
<-> CP Station Design Current Density:
Safety factor, S.F S.F ≔ 1.5
Design Life, T (yr) T ≔ 30 yr
Design CP Current, Id (A) Id ≔ S.F ⋅ I = 14.956 A
Protection Length by a CP Station, Lp (km) Lp ≔ 30 km Lp
Icp ≔ Id ⋅ ―= 8.974 A
L
<-> Anode Properties:
A
Anode Current Density, ia (A/m^2) Apm ≔ ――
Anode Consumption Rate, Cr (kg/A.yr) m2
kg
Anode Utilization Factor, U kgpAyr ≔ ――
A ⋅ yr
⎡ ia ⎤
⎢ ⎥
C ≔ Anode Type: High Silicon Iron
⎢ r⎥
⎣U⎦

Anode Length, la (m) la ≔ 1 m


Anode Diameter, da (in) da ≔ 4 in
Anode Weight, wa (kg) wa ≔ 22 kg
Anode Surface Area, a (m2) as ≔ π ⋅ da ⋅ la = 0.319 m 2

<-> Anode Requirements: Icp


Anodes Quantity Required, Ni (by current) Ni ≔ ――= 8.032
Anodes Quantity Required, Nw (by weight) as ⋅ ia
Cr
Nw ≔ Icp ⋅ T ⋅ ――= 9.413
U ⋅ wa
Anodes Quantity Provided, N (assume) N ≔ 10

Page 1 of 2
Impressed Current Cathodic Protection Design for Pipelines

Impressed Current CP Design Calculation

DATA DESCRIPTION: INPUT VALUES: CALCULATION OUTPUT:

<-> Vertical Ground Bed (GB) Design:


Anode to Anode Spacing, Sa (m) Sa_a ≔ 5 ft
Anode Clearence at Bottom of Active GB, (m) Sacb ≔ 5 ft
Anode Clearence at Top of Active GB, (m) Sact ≔ 5 ft
Minimum Vertical GB Active Length, Lmin (m)

Lmin ≔ Sacb + ((N - 1)) ⋅ Sa_a + N ⋅ la + Sact = 26.764 m


Vertical GB Active Length Provided, Lgb (m)
Lac.GB ≔ 30 m
Vertical GB Inactive Length, Lac (m) Linac.GB ≔ 15 m

Vertical GB Total Length, Lgb (m) LGB ≔ Lac.GB + Linac.GB = 45 m

<-> Vertical Ground Bed (GB) Resistance:

Page 2 of 2