0% found this document useful (0 votes)
120 views11 pages

Optix RTN 900 Microwave Test Report

The document describes an acceptance test procedure for an Optix RTN 900 microwave radio system. It includes steps to check the configuration, perform loopback tests, measure receive power levels, test protection switching, check for interference, and ensure other parameters are within specifications. The test procedure involves testing at both Station A and Station B and collecting results that must be approved by both a tester and approver.

Uploaded by

MemoPalacio
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
120 views11 pages

Optix RTN 900 Microwave Test Report

The document describes an acceptance test procedure for an Optix RTN 900 microwave radio system. It includes steps to check the configuration, perform loopback tests, measure receive power levels, test protection switching, check for interference, and ensure other parameters are within specifications. The test procedure involves testing at both Station A and Station B and collecting results that must be approved by both a tester and approver.

Uploaded by

MemoPalacio
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 11

Optix RTN 900 Microwave Acceptance Test

ACCEPTANCE TEST DATA

MICROWAVE RADIO SYSTEM

OPTIX RTN 900

STATION A : ______________________________

STATION B : ______________________________

Date:__________________
Provided by: ___________________ _
Date:__________________
Approved by:___________________ _
Optix RTN 900 Microwave Acceptance Test

CONTENT :

1. Visual Check

2. Configuration Check

3. Loop Back Test (Local and remote)

4. Receive Power Level Result

5. Protection Switching Test

6. Interference Check

7. Power Voltage Check

8. Clock Setting Check

9. NE Visibility on U2000 Server

10. Network Configuration

11. Ethernet Service Connectivity

12. Terminal Inventory Check

13. Browse Alarm Check

14. ATPC Test

15. IP Service Functionality Test

16. IP Service Alarm Check

17. BER Test Measurement

18. 24 Hours Performance Monitoring

19. Document Attachment


Optix RTN 900 Microwave Acceptance Test

REVISION HISTORY

Date Revision Description Authors

2011/July/02 V1.0 First Release was completed. Aris B / Liuyao

2012/Feb/22 V2.0 Add NE Visibility check on U2000 Rian Ikbal / Weidai


Add ETH functional test
Add functional for N+1
configuration
Add BER test for Hybrid
configuration

2012/Feb/27 V2.1 Update for Configuration check Rian Ikbal / Weidai


part
Add link configuration information
(Modulation, E1 and ETH cap)

2012/March/19 V2.2 Update for interference test BO TX CortonKwok


method and performance
monitoring.
Optix RTN 900 Microwave Acceptance Test

1) Visual Check

1) Serial Number

Station: A _________________________________________

UNIT Serial No

IDU

ODU 1
ODU 2(*)
ODU 3(**)
ODU 4(**)
Hybrid (*)
Antenna
(*) Fit only applicable and if equipped
(**) Applicable for configuration N+1 protection

Station: B _________________________________________

UNIT Serial No

IDU

ODU 1
ODU 2(*)
ODU 3(**)
ODU 4(**)
Hybrid (*)
Antenna

UNIT Serial No
IDU
ODU 1
ODU 2(*)
Hybrid(*)
Antenna
(*) Fit only applicable Cell and if equipped

2)Antenna
Antenna Diameter (M) Height (M) Polarization

Station:A ___________________ □Vertical □Horizontal


Optix RTN 900 Microwave Acceptance Test

Station: B ___________________ □Vertical □Horizontal

Item Check OK NOK

3) Check the physical Out-door installation. □ □

4) Check the Radio indoor equipment installation. □ □

5) Indoor Cable rack and structure installation. □ □

6) Labeling. □ □

7) Grounding cable installation □ □

2) Configuration Check

Station A Set-Up Channel 1 Channel 2 Channel 3 (*) Channel 4 (*)


Frequency Plan (MHz)        
Transmitted frequency (MHz)        
Received frequency (MHz)        
ODU Sub Band        
Tx power requested (dBm)        
Modulation (**)  
Assured E1 Capacity (**)  
E1 Capacity (**)  
Ethernet Capacity (Mbps) (**)  
(*) if Applicable
(**)Screenshot from U2000 server should available as attachment, without screenshot on U2000 will record as
punch list

Station B Set-Up Channel 1 Channel 2 Channel 3 (*) Channel 4 (*)


Frequency Plan (MHz)        
Transmitted frequency (MHz)        
Received frequency (MHz)        
ODU Sub Band        
Tx power requested (dBm)        
Modulation (**)  
Assured E1 Capacity (**)  
E1 Capacity (**)  
Ethernet Capacity (Mbps) (**)  
(*) if Applicable
(**)Screenshot from U2000 server should available as attachment, without screenshot on U2000 will record as
punch list
Optix RTN 900 Microwave Acceptance Test

3. Loop Back Test (Local and remote)


Loop Back Test
Station A Local Tributary □ OK □ NOK
Station B Local Tributary □ OK □ NOK

4. Receive Power Level Result


Station A Station B
ODU 1 ODU 2 ODU 3 ODU 4 ODU 1 ODU 2 ODU 3 ODU 4
Item (*) (*) (*) (*)
Rx level in link budget (dBm)                
Rx Level (dBm)                
Tx Power (dBm)                
(*) if Applicable

5. Protection Switching Test


System Type : □ 1+1HSB □ 1+1FD □ 1+1SD □ 2+1FD □ 3+1FD
Site Switching Result
Station A □ OK □ NOK □NA(*)
Station B □ OK □ NOK □NA(*)
(*) if the configuration only 1+0
This test includes BER Test measurement to check the following:
 No errors on F/D and S/D Protection Switching Test
 Errors on HSB Protection Switching Test.
Optix RTN 900 Microwave Acceptance Test

6. Interference Check
Interference test should perform at all frequency within bandwidth .

RSL (dBm) (**) Station A RSL (dBm) (**) Station B


Frequency Station B Station A
(TX Off at Station B) (TX Off at Station A)
Within TX TX
ODU ODU ODU ODU ODU ODU ODU ODU
Bandwidth Frequency Frequency
1 2 3 (*) 4 (*) 1 2 3 (*) 4 (*)

FC-28 MHz (*)

FC-24.5 MHz (*)

FC-21 MHz (*)

FC-17.5 MHz (*)

FC-14 MHz (*)                    

FC-10.5 MHz (*)                    

FC-7 MHz (*)                    

FC-3.5 MHz (*)                    


Freq Center                    

FC+3.5 MHz (*)                    

FC+7 MHz (*)                    

FC+10.5 MHz(*)                    

FC+14 MHz (*)

FC+17.5 MHz(*)

FC+21 MHz (*)

FC+24.5 MHz(*)

FC+28 MHz (*)                    

(*) If applicable
(**) Receive power level <-80db no interference affect on link. Receive power level -79dB<receive power
level <-74dB, refer to BER test, no error in BER test no interference affect on link. Receive power level >-
74dB interference on link. Test screenshot should available as attachment
(***) Screenshot from U2000 server should available as attachment, without screenshot on U2000 will record
as punch list

7. Power Voltage Check


Station name Power Supply Voltage
Station A [+ ] Volt
Station B [+ ] Volt

8. Clock Setting Check


Optix RTN 900 Microwave Acceptance Test

Site Clock Setting Result Clock Alarm Check on U2000

Station A □ OK □ NOK □NA □ OK □ NOK □NA


Station B □ OK □ NOK □NA □ OK □ NOK □NA
(*) Screenshot from U2000 server should available as attachment, without screenshot on U2000 will record as
punch list

9. NE Visibility on U2000 Server


Site NE Visibility on U2000 Server
Station A □ OK □ NOK (*)
Station B □ OK □ NOK (*)
(*) Screenshot from U2000 server should available as attachment, without screenshot and not visible on U2000
will record as punch list
10. Network Configuration
Station A Station B
Station Name
Name : Name :
NE ID Based On Design
NE ID Actual
IP Address
Net Mask

11. Ethernet Service Connectivity


Site Ethernet Test Result
Station A □ OK □ NOK □NA(*)
Station B □ OK □ NOK □NA(*)
(*)If board not available on IDU

12. Terminal Inventory


Station A
Equipment Checking IDU Type Slot Position Board Style Board Barcode
CSHA RTN 910
CSH RTN 950
CSHN RTN 980
IFU2 / ISU2 (*)
IFU2 / ISU2 (*)
IFU2 / ISU2 (*)
IFU2 / ISU2 (*)
IFU2 / ISU2 (*)
IFU2 / ISU2 (*)
EM6T / EM6F (*)
EM6T / EM6F (*)
SP3D
Optix RTN 900 Microwave Acceptance Test

SP3S
SL1D
SL1D
AUX
FAN
PIU
(*) if Applicable

Station B
Equipment Checking IDU Type Slot Position Board Style Board Barcode
CSHA RTN 910
CSH RTN 950
CSHN RTN 980
IFU2 / ISU2 (*)
IFU2 / ISU2 (*)
IFU2 / ISU2 (*)
IFU2 / ISU2 (*)
IFU2 / ISU2 (*)
IFU2 / ISU2 (*)
EM6T / EM6F (*)
EM6T / EM6F (*)
SP3D
SP3S
SL1D
SL1D
AUX
FAN
PIU
(*) if Applicable

13. Browse Alarm Check


Check Item Station A Station B

Alarm test, including ODU and IDU sections □ OK □ NOK □ OK □ NOK

14. ATPC Test


tem Check Station A Station B
Tx nominal power (dBm)
ATPC Range - PTX Min Value (dBm)
ATPC Range - PTX Max Value (dBm)
ATPC Rx Threshold - Low Power (dBm)
Optix RTN 900 Microwave Acceptance Test

15. IP Service Functionality Test (IP Microwave)


Ethernet Test Result Remark
Station A [ ] OK [ ] NOK
Station B [ ] OK [ ] NOK
Remark: Ping test from RTN to LSW gateway for 60 minutes. If reply normal, mark OK, but if RTO, mark NOK,
and give remark.

16. IP Service Alarm Check (IP Microwave)

No Alarm on EM6T Remark


Station A [ ] OK [ ] NOK
Station B [ ] OK [ ] NOK
Remark: Check whether have any alarm on EM6T board. If no alarm, mark OK, but if have alarm, mark NOK,
and give remark.

17. BER Test Measurement (TDM Microwave)


SETUP Main Channel
No errors (*) □ OK □ NOK
(*) Value applicable in normal propagation condition
(*) All Background BER Test, applicable only in normal propagation condition for 30-60min

18. 24 Hours Performance Report


Site UAS ES SES BBE
Site A ID_Site A Name
Site B ID_Site B Name

UAS, ES, SES, BBE should be 0 within 24hours. If the performance is good, it could prove interference
did not presence.
19. 24 hours performance monitoring
SETUP Main Channel
UAS/BBE/ES/SES is 0 □ OK □ NOK

20. Document Attachment


 Software Commisioning
 All range Interference Test (freq center lower until freq center upper)
 Clock configuration and Clock Alarm
 NE Visibility on U2000 server
 Alarm Query
 Ping test result (for ETH Function test)
 BER test result (for TDM Function test)
Optix RTN 900 Microwave Acceptance Test

 24 Hours Performance Report

You might also like