Centrifugal Pump: Trouble-shooting Matrix
Common Symptoms
Mechanical Seal Leak / failure
Discharge Pressure too high
High Amps - input currant
High Bearing temperature
Low Amps - Input currant
High Vibrations Or Noise
Unstable Flow, Pr, amps
Discharge Pressure low
High Flow
Low Flow
No Flow
Common Symptoms and Possible Causes
Operational Check points
Back pressure or System resistance high. Control valve opening % less
Back pressure Or System resistance low. Control valve opening % more
High Specific gravity
Low Specific gravity
Higher Operating Temperature
Lower Suction Pressure
Higher Suction Pressure
Clogged suction strainer
Air Or Vapor entrainment / Not Vented / product tends vaporised
Suction Valve is closed
Closed disharge / Dis. heck valve installed in reverse direction
Hidden flow / Spillback valve is leaking or open
Pump Related Check Points
Impeller Diameter is higher than the rated
Impeller Diameter is smaller than the rated
Rotor is seized
Shaft is broken or shaeared off
Pump Internals' are worn out / clearances are changed
Rotor Unbalance / Misalignment / Bearing issues
Rusting / pitting / deposition on wet end components
Coupling not installed
Quality or Quantity of lube oil is not proper
Seal and Seal plan related check points (Not in detail)
By pass flush flow (plan 11, 21, 31) is more, RO messing or oversized
Seal faces are worn out
Seal faces are over compressed
Seal faces are under compressed
Seal hang up / dynamic O ring hang up
Leakage through elastomer sitting area (Various reason)
Incorrect buffer, barrier fluid or its operating pressure or temperature
Plan 13 - Orifice is missing or oversized
Electrical Check Points (Driver and Power supply)
Reverse rotation of driver
Driver rpm is low
Low Voltage / Imbalance voltage across 3 phases
High Voltage / Imbalance voltage across 3 phases
Motor internal issues
Local ammeter calibration / functioning issue
Instrumentations check points
Calibration issue of Gauges / transmitters
Instrument Venting issue or Malfunction
Issue in configuration of transmitters output to PLC / DCS
Reliability and Condition monitoring
Issue with mounting surface of sensor where vibration being captured
Temperature gun's reliability and sensitivity
Human error in capturing vibration / temperature reading
Probability is more (Could be Predominant cause)
Probability is normal
Probability is less (Less likely but advisable to check)