0% found this document useful (0 votes)
122 views

RC Column Design (BS8110) - Part2

This document contains calculations for the reinforcement of a short column with single axis bending about the major axis. Key details include: - The column has a height of 600mm and width of 300mm - The main reinforcement consists of 2 bars of 20mm diameter each, providing a total steel area of 1256.6mm2 - The column is designed to resist an axial load of 10kN and bending moment of 10kNm about the major axis - Checks are performed to ensure the steel yields in tension before the concrete crushes in compression

Uploaded by

Himura_
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
122 views

RC Column Design (BS8110) - Part2

This document contains calculations for the reinforcement of a short column with single axis bending about the major axis. Key details include: - The column has a height of 600mm and width of 300mm - The main reinforcement consists of 2 bars of 20mm diameter each, providing a total steel area of 1256.6mm2 - The column is designed to resist an axial load of 10kN and bending moment of 10kNm about the major axis - Checks are performed to ensure the steel yields in tension before the concrete crushes in compression

Uploaded by

Himura_
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Project Job no.

JPPJ Calcs for Start page no./Revision


2
Calcs by Calcs date Checked by Checked date Approved by Approved date
ZH 28/05/2021

BS8110:Table 3.19
Effective height – minor axis; ley = y  lo = 2.250 m
Slenderness check; ley/b = 7.50
The braced column is short (minor axis)

Short column - single axis bending (major axis)


Define column reinforcement
Main reinforcement in column
Assumed diameter of main reinforcement; Dcol = 20 mm
Assumed no. of bars in one face (assumed sym); Lncol = 2
Area of "tension" steel; Ast = Lncol    Dcol2 / 4 = 628 mm2
Area of compression steel; Asc = Ast = 628 mm2
Total area of steel ; Ascol =   Dcol2 / 4  2  (Lncol + (Lncol -2)) = 1256.6 mm2
Percentage of steel; Ascol / (b  h) = 0.7 %

Design ultimate loading


Design ultimate axial load; N = 10 kN
Design ultimate moment (major axis); Mx = 10 kNm
Minimum design moments
Min design moment; Mxmin = min(0.05  h, 20 mm)  N = 0.2 kNm

Design moments
Design moment; Mdesign = max (abs(Mx) , Mxmin) = 10.0 kNm
Set up section dimensions for design:-
Section depth; D = h = 600 mm
Depth to "tension" steel; d = h' = 545 mm
Section width; B = b = 300 mm
Library item - Calcs – short col N+Mmaj

Check of design forces - symmetrically reinforced section

NOTE
Note:- the section dimensions used in the following calculation are:-
Section width (parallel to axis of bending); B = 300 mm
Section depth perpendicular to axis of bending); D = 600 mm
Depth to "tension" steel (symmetrical); d = 545 mm
Tension steel yields
Determine correct moment of resistance
NR =ceiling(if(xcalc<D/0.9, NR1 , NR2 ),0.001kN) = 10.0 kN

MR = ceiling(if(xcalc<D/0.9, MR1 , MR2 ) ,0.001kNm) = 143.4 kNm


Applied axial load; N = 10.0 kN
Check for moment; Mdesign = 10.0 kNm
Moment check satisfied

Check min and max areas of steel


Total area of concrete; Aconc = b  h = 180000 mm2
Area of steel (symmetrical); Ascol = 1257 mm2
Minimum percentage of compression reinforcement; kc = 0.40 %