Model 41

Precision Low Profile Load Cell


DESCRIPTION
Model 41 is a low profile “pancake” type load cells. These reduce off-center and side-loading effects. It provides high
bonded foil, strain gage load cells are engineered to measure performance in non-linearity, hysteresis, and repeatability speci-
loads from 5 lb to 500,000 lb. The tension/ compression fications for such applications as tube mills, extruding processes
Model 41 is designed with the threaded hole running completely and weighing. Each unit has a welded construction and can be
through the center of the cell. Model 41 utilizes two stabilizing hermetically sealed for added durability. Model 41 load cells are
diaphragms, which are welded to the sensing member to available with optional 0 Vdc to 5 Vdc or 4 mA to 20 mA output.

Approved Approved

FEATURES
• 0.1 % accuracy
• 5 lb to 500000 lb
• mV/V output (standard); 4 mA to 20 mA and 0 Vdc to 5 Vdc
(optional) outputs
• Double diaphragm design
• Intrinsically safe available (2N option only)16
• CE approved17
Model 41
PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS
Characteristic Measure Characteristic Measure
Load ranges18 5 lb to 500000 lb Maximum allowable load 150 % FS 1
Non-linearity, 5 lb to 25 lb ±0.2 % full scale Weight See table
Non-linearity, Material 17-4PH stainless steel
±0.1 % full scale
50 lb to 500000 lb Less than 200,000 lb
Hysteresis, 5 lb to 25 lb ±0.1 % full scale Material greater than or Carbon steel
Hysteresis, equal to 300000 lb
±0.08 % full scale
50 lb to 500000 lb Deflection See table
Non-repeatability, 5 to 25 lb ±0.1 % full scale Natural frequency See table
Non-repeatability,
±0.03 % full scale
50 lb to 500000 lb RANGE CODES
Output (tolerance),
2 mV/V ±0.5 % full scale
Range Available ranges Range Available ranges
5 lb to 25 lb Code Code
Output (tolerance), AT 5 lb DV 10000 lb
3 mV/V ±0.5 % full scale
50 lb to 500000 lb
AV 10 lb EJ 15000 lb
Operation Compression/tension13
BL 25 lb EL 20000 lb
Resolution Infinite
BN 50 lb EN 30000 lb
5-point calibration: 0 %, 50 % and 100
Standard calibration BR 100 lb EP 50000 lb
% of full scale in tension only
CN 250 lb ER 75000 lb
CR 500 lb ET 100000 lb
ENVIRONMENTAL SPECIFICATIONS
CV 1000 lb FJ 150000 lb
Characteristic Measure
DL 2000 lb FL 200000 lb
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F]
DN 3000 lb FN 300000 lb
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]
DP 4000 lb FP 400000 lb
Temperature effect, zero 0.002 % full scale/°F
DR 5000 lb FR 500000 lb
Temperature effect, span 0.002 % full scale/°F
DT 7500 lb

ELECTRICAL SPECIFICATIONS WIRING CODES


Characteristic Measure Connector Unamplified (Std.)
Strain gage type Bonded foil A (+) excitation
Excitation (calibration) 10 Vdc B (+) excitation
Insulation resistance 5000 mOhm @ 50 Vdc C (-) excitation
Bridge resistance 350 ohm (nominal) D (-) excitation
(tolerance) E (-) output
Zero balance (tolerance) ±1 % full scale F (+) output
Shunt calibration data Included
Electrical termination (std) PTIH-10-6P DEFLECTIONS AND RINGING FREQUENCIES
5 lb to 5000 lb
Capacity (lb) Deflection @ Natural ringing Weight
Electrical termination (std) MS3102E-14S-6P full scale (in) frequency (Hz) (lb)
7500 lb to 500000 lb
5 to 25 0.001 2000 0.8
Mating connector PT06A-10-6S or equiv. (AA111)
5 lb to 5000 lb (not incl.) 50 to 1000 0.002 4600 1.5

Mating connector MS3106A-14S-6S (AA121) 2000 to 5000 0.002 10000 2.0


7500 to 500000 lb (not incl.) 7500 to 15000 0.003 6000 8.8
20000 to 50000 0.004 8000 11.0
75000 to 100000 0.006 5500 30.9
150000 to 200000 0.010 4500 46.3
300000 to 500000 0.010 4100 130.1
2 Honeywell • Sensing and Control
Precision Low Profile Load Cell
iNTERNAL AMPLIFIERS
Current two- Intrinsically
Amplifier Voltage out- Voltage out- Voltage out- Current three-
wire: Option safe amp: Op-
specifications put: Option 2b put: Option 2c put: Option 2t wire: Option 2j
2k tion 2n (2N)***
Output signal ±5 V 0-5 V or ±5 V @ 0-10 V or ±10 V 4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
45 mA @ 45 mA
Input power (voltage) ±15 Vdc or 26-32 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 9 Vdc to 9 Vdc to
Vdc 32 Vdc 28 Vdc
Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
Freq. response 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
Power supply rejection 60 db 60 db 60 db 60 db 60 db 60 db
Operating temperature -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F
Reverse volt. protection Yes Yes Yes Yes Yes Yes
Short circuit protection Momentary Momentary Momentary Yes Yes Yes
Wiring code: connector A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply A (+) Supply
B Output common B Output common** B Output common** B Output common** B No connection B No connection
C Supply return C Supply return** C Supply return** C Supply return** C No connection C No connection
D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output D (+) Output
E Shunt Cal 1 E Shunt Cal 1 E Shunt Cal 1 E Shunt Cal 1 E Case ground E Case ground
F Shunt Cal 2 F Shunt Cal 2 F Shunt Cal 2 F Shunt Cal 2 F No connection F No connection

Wiring code: cable R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply R (+) Supply
Bl Output common Bl Output com* Bl Output com* Bl Output com* Bl (+) Output Bl (+) Output
G Supply return G Supply return* G Supply return* G Supply return* W Case ground W Case ground
W (+) Output W (+) Output W (+) Output W (+) Output
B Shunt Cal 1 B Shunt Cal 1 B Shunt Cal 1 B Shunt Cal 1
Br Shunt Cal 2 Br Shunt Cal 2 Br Shunt Cal 2 Br Shunt Cal 2

* Black and green wires are internally connected.


** Pins B and C are internally connected.
*** See our Web site (http://measurementsensors.honeywell.com) for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00.

ALLOWABLE MAXIMUM LOADS


Capacity (lb) Side load Bending Torque
(lb) (lb-in) (lb-ft)
5 to 25 50 % 40 % 25 %
50 to 1000 45 % 35 % 25 %
2000 to 5000 30 % 25 % 25 %
7500 to 30000 20 % 20 % 15 %
50000 to 100000 20 % 20 % 15 %
150000 to 200000 20 % 20 % 15 %
300000 20 % 20 % 10 %
400000 20 % 20 % 10 %
500000 20 % 20 % 10 %

Honeywell • Sensing and Control 3


Model 41
OPTION CODES
Many range/option combinations are available in our quick-ship and fast-track manufacture programs.
Please see http://measurementsensors.honeywell.com for updated listings.
Load ranges 5, 10, 25, 50, 100, 250, 500, 1000, 2000, 5000, 3000, 4000, 7500, 10000, 15000, 20000, 30000, 50000, 75000, 100000, 150000,
200000, 300000, 400000, 500000 lb
Temperature 1a. 60 °F to 160 °F 1d. -20 °F to 130 °F 1g. 70 °F to 325 °F14 1j. 0 °C to 50 °C
compensation 1b. 30 °F to 130 °F 1e. -20 °F to 200 °F 1h. 70 °F to 400 °F14 1k. -20 °C to 85 °C
1c. 0 °F to 185 °F 1f. 70 °F to 250 °F 1i. -65 °F to 250 °F14 1m. -25 °C to 110 °C
Internal 2b. 4 wire, ±5 Vdc 2j. 4-20 mA (three-wire) 2n (2N) 4 mA to 20 mA (wire) 2u. Unamplified, mV/V output
amplifiers 10 2c. 0-5 Vdc output output intrinsically safe20
2k. 4 mA to 20 mA (two- 2t. 0 Vdc to 10 Vdc
wire)20
Internal ampli- 3a. Input/output isolation19
fier enhance- 3d. Remote buffered shunt calibratrion8
ments
Overload 4a. Overload stops
stops
Electrical 6a. Bendix PTIH-10-6P 6-pin 6f. Integral cable: PVC 6i. Integral underwater 6q. Molded integral cable poly-
termination (ranges to 5000 lb) 6g. Integral cable: Neo- cable9 urethane9
6b. MS3102E-14S-6P (rang- prene9 6j. 1/2-14 conduit fitting with 6v. Phoenix connector on end of
es 7500 lb and up)9 6h. Integral cable: Silicone 5 ft of 4 conductor PVC cable
6e. Integral cable: Teflon cable
Shunt calibra- 8a. Precision internal resistor14
tion
Special cali- 9a. 10 point (5 up/5 down) 20 % increments @ 68 °F
bration 9b. 20 point (10 up/10 down) 10 % increments @ 68 °F
9c. ASTM E-74 calibration
Bridge resist- 12b. 5000 ohm (foil)
ance
Zero and span 14a. No access to pots
adjustment 14b. Top access to pots
Electrical con- 15a. Horizontal electrical exit port orientation 15c. Radial electrical exit port orientation
nector orienta- 15b. Vertical electrical exit port orientation 15d. Connector on end of cable
tion
Special cali- 30a. Compression only calibration, positive in compression
bration 30b. Tension and compression calibration, positive in tension
30c. Compression only calibration, negative in compression
30d. Tension and compression calibration, positive in compression
Bridge type 31a. Dual bridge
Shock and 44a. Shock and vibration resistance
vibration
Interfaces 53e. Signature calibration14
53t. TEDS IEEE 1451.4 module15

4 Honeywell • Sensing and Control


Precision Low Profile Load Cell
MOUNTING DIMENSIONS
Ranges D mm H mm H*** F# ØG ØK mm T A mm A* mm B mm B* mm C mm
lb [in] [in] mm mm [in] [in] [in] [in] [in] [in] [in]
[in] B.C. thru
5, 10, 25 63,5 20,32 44,45 6 50,8 4,83 1/4-28 20,83 63,5 19,05 22,86 31,75
[2.50] [0.80] [1.75] [2.000] [0.19] UNF [0.82] [2.5] [0.75] [0.9] [1.25]
50, 100, 76,2 25,4 44,45 6 57,15 7,11 3/8-24 20,83 63,5 19,05 22,86 31,75
250, 500, [3.00] [1.00] [1.75] [2.250] [0.28] UNF [0.82] [2.5] [0.75] [0.9] [1.25]
1000
2000, 88,9 25,4 44,45 6 66,68 8,64 1/2-20 20,83 63,5 19,05 22,86 31,75
3000, [3.50] [1.00] [1.75] [2.625] [0.34] UNF [0.82] [2.5] [0.75] [0.9] [1.25]
4000,
5000
7500, 139,7 45,7 45,7 8 114,3 10,16 1-14 31,75 58,42 38,1 38,1 50,8
10000, [5.50] [1.80] [1.80] [4.500] [0.40] UNS [1.25] [2.3] [1.50] [1.5] [2.00}
15000
20000, 152,4 45,7 45,7 8 123,83 13,46 1 1/2-12 31,75 58,42 38,1 38,1 50,8
30000, [6.00] [1.80] [1.80] [4.875] [0.53] UNF [1.25] [2.3] [1.50] [1.5] [2.00}
50000
75000, 228,6 63,5 63,5 12 196,85 16,76 2-12 UN 31,75 58,42 38,1 38,1 50,8
100000 [9.00] [2.50] [2.50] [7.750] [0.66] [1.25] [2.3] [1.50] [1.5] [2.00}
150000, 279,4 63,5 63,5 12 241,3 19,81 2 1/2-12 31,75 58,42 38,1 38,1 50,8
200000 [11.00] [2.50] [2.50] [9.500] [0.78] UN [1.25] [2.3] [1.50] [1.5] [2.00}
300000, 355,6 107,95 107,95 12 298,45 26,16 3 1/2-8 31,75 58,42 38,1 38,1 **
400000, [14.00] [4.25] [4.25] [11.750] [1.03] UN [1.25] [2.3] [1.50] [1.5]
500000
* Length of load cell with amplified option (see option codes)
** C dimension varies on high ranges. Consult factory
*** H dimension with 2n(2N) amplifier
TYPICAL SYSTEM DIAGRAM
In-line amplifiers (used with unamplified units only)
Amplifier Output
Universal in-line amplifiers
UV ±5 Vdc
UV-10 ±10 Vdc
UBP 0 ±5 Vdc
U3W 4 mA to 20 mA (3-wire)
U2W 4 mA to 20 mA (2-wire)
DIN rail mount in-line amplifiers
DV-05 0 ±5 Vdc (3-wire)
DA-05 4 mA to 20 mA (3-wire)
DV-10 0 ±10 Vdc (3-wire)

Model 41

Customer supplied
Chart recorder
Alarm panel
1
Data acquisition
Computer
PLC
Mating connectors & cables
PT06A-10-6S, std.
Mounting options PT06E-10-6S
Display units
1. Pull plate MS3106A-14S-6S
SC500
2. Load button SC2000
SC2001
SC3004
GM (unamplified only)
GM-A (amplified only)
NK (unamplified only)
HH (unamplified only)

Honeywell • Sensing and Control 5


Model 41 Precision Low Profile Load Cell
NOTES
1. Allowable maximum loads - maximum load to be applied without Warranty. Honeywell warrants goods of its manufacture as
damage.2 being free of defective materials and faulty workmanship.
2. Without damage - loading to this level will not cause excessive zero
shift or performance degradation. The user must consider fatigue Honeywell’s standard product warranty applies unless agreed
life for long term use and structural integrity. All structurally critical to otherwise by Honeywell in writing; please refer to your
applications (overhead loading, etc.) should always be designed with
order acknowledgement or consult your local sales office for
safety redundant load paths.
3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal pro- specific warranty details. If warranted goods are returned to
vides 50 % (unamplified units), 75 % (4 mA to 20 mA 3-wire units) or Honeywell during the period of coverage, Honeywell will repair
80 % (voltage amplified units) of full scale output for quick calibration.
Shunt calibration comes standard with internal amplifier option 2b, 2c, or replace, at its option, without charge those items it finds
2t and 2j. defective. The foregoing is buyer’s sole remedy and is in lieu
4. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown;
W=White; G=Green. Color specifying cable and number or letter
of all warranties, expressed or implied, including those of
specifying connector. merchantability and fitness for a particular purpose. In no
5. No mating connector necessary for cable option. event shall Honeywell be liable for consequential, special, or
6. Adding any internal amplifiers on 5 lb to 25 lb ranges will increase
delivery time. indirect damages.
7. Option 2n (2N) on 5 to 5000 lb. ranges will typically take 12 weeks for
delivery. While we provide application assistance personally, through our
8. Option 3d is not available with option 2n (2N) or 2k. literature and the Honeywell web site, it is up to the customer to
9. Not available with option 1c, 1e, 1f, 1g, 1h or 1i.
determine the suitability of the product in the application.
10.Consult factory.
11.Availability varies with range, consult factory. Specifications may change without notice. The information we
12.Option only pertinent when option 2n (2N) selected.
13.Standard calibration for tension/compression load cells is in tension supply is believed to be accurate and reliable as of this printing.
only. However, we assume no responsibility for its use.
14.Not available with amplified output.
15.Consult factory for TEDS availability with amplified models.
16.Range dependent; consult factory. Termination dependent; consult
factory. WARNING
17.Internal amp and termination dependent; consult factory.
18.This unit calibrated to Imperial (non-Metric) units. PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
Find out more
Honeywell serves its customers WARNING
through a worldwide network of MISUSE OF DOCUMENTATION
sales offices, representatives • The information presented in this datasheet is for
and distributors. For application reference only. DO NOT USE this document as product
assistance, current specifica- installation information.
tions, pricing or name of the • Complete installation, operation and maintenance
information is provided in the instructions supplied with
nearest Authorized Distributor,
each product.
contact your local sales office.
Failure to comply with these instructions could result in
To learn more about Honeywell’s
death or serious injury.
test and measurement products,
call +1-614-850-5000, visit
http://measurementsensors.
honeywell.com, or e-mail inqui-
ries to [email protected]

Sensing and Control


Honeywell
1985 Douglas Drive North
008609-3-EN IL50 GLO 
Golden Valley, MN 55422 USA June 2013
Copyright © 2013 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing

You might also like