100% found this document useful (1 vote)
109 views6 pages

Akd - 4792a - Fuel Pump Index

SU Fuel pump Guide

Uploaded by

Damian Rowe
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
100% found this document useful (1 vote)
109 views6 pages

Akd - 4792a - Fuel Pump Index

SU Fuel pump Guide

Uploaded by

Damian Rowe
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 6
AKD 4792. A FUEL PUMP INDEX OF SERVICE LITERATURE GENERAL INFORMATION AND IDENTIFICATION MANUFACTURED. % THE S.U. CARBURETTER COMPANY LIMITED WOOD LANE + — ERDINGTON + _ BIRMINGHAM 24 TELEPHONE: ERDINGTON 7371 (lines) TELEGRAMS: CARBURFLEX, BIRMINGHAM SU, SERVICE SHEET No. AUA 237, © Mie oni MOTOR CORPORATION LIMITED, 1966 S.U, FUEL PUMPS—IDENTIFICATION OF BASIC TYPES 1 Models) High- or low-pressure. Single: 6, 12-, or 24-volt. Minimum flow, HP—7 gal. per hour, L—8 gal. per hour, Valves in ‘outlet connection, plain disc, outlet valve in cage, Filter at bottom. Outlet connection at top. Sandwich plate and gasket between diaphragm and body. Earller HP coll housing 4 In. longer than L, fater modals same external length as L. ? Large capacity. Single: 12- or 2A-volt. Minimum flow, 4124 gal. per hour. Valves inside top cover, outlet valve in cage, ‘earlier valves both plain disc, ater inlet plain dise with spring, ‘outlet plastic assembly. Filter Inside bottom cover. Les Land HP dual High- or low-pressure, Dual 7 12vole, working simultaneously. Cc Minimum flow, HP—16 gal. per hour, L—20 gal, per hour, Valves under top caps, outlet valves In cage, plan dsc. Filter at bottom, wi 19698, High-pressure, Single: 12-volt. Minimum flow, 7 gal. per sP hour. Valves inside body, plastic type held by retainer plate and single screw. Filter In Inlet connection. S.U, FUEL PUMPS—IDENTIFICATION OF BASIC TYPES (Later Models) High-pressure. Single: 12-volt. Minimum flow, 7 gal. per hour. Valves accessible externally through inlet and 1 Outlet nozzles, plastic type all held by circular clamp plate and two serews. Filter under inlet nozzle. High-pressure. Single: {2vole, Minimum flow, 15 gal. per hour. Valves inside body, plastic type held by clamp plate ‘and two screws. Filter on inlet valve, plain alr bottle on Inlet, flow-smoothing device on delivery, AUF 400 range High-pressure. Dual working simul- taneously. Single inlet, single outlet. A2volt. Minimum flow from both— 30 gal. per hour. Valves inside body, plastic type held by clamp plate and two screws. Filter on inlet valve. Plain air bottle on inlet, flow-smoothing device ‘on delivery. AUF 500 range High-pressure. Dual normally working Separately. Dual inlet, single outlet. 12-volt. Minimum flow, 124 gal. per hour each Valves Inside body, plastic type held by clamp plate and two serews, Filter on inlet valve, Plain air bottle on inlet, diaphragm= ‘type on delivery. * Pump voltage All S.U. pumps can be identified for voltage by the marking . and colour of the end-cover, thus: 6-yolt—Brown Tevolt—Blaeke A-volt—Blue. INDEX OF PUMP SERVICE LITERATURE Sheet No. Replaced by: Part 1 General 1 Information and Identification =. AKD 4792 A List of abridged pump specifications =. ss vs AKO 4812 C Pump type/ear model reference ar AKD 4813 B Recommended mounting positions «. cee AKD 4814 A Part 2. Deserlption and Fault Diagnosis Land HP type single pump... se eee eee ve AKD 4793 B LCS type pump ° a) se ae AKD 4794 B Land HP type dual pump 6. 9 ee cen AKD 4795 B SP type pumps. ee eee Pa AKD 4796 B AUF 200 range pump ao oD 5 +s AKD 4797 B AUF 300 range pump AKD 4798 8 ‘AUF 400 range pump 5 7 AKD 4799 B ‘AUF 500 range pump ss eee tess AKD 4800 8 Part 3, Dismantling and Reassombling Instructions Land HP type single pump 6. =. eevee eee oe AKD 4801 LCS type pump . se ee ARD 4802 Land HP type dual pump sees See ARD 4803 SP type pump... ea ‘AKD 4804 AUF 200 range pump a, AKD 4805 Supploment—Plastle Armature Gulde Plate... AKD 4805/1 AUF 300 range pump sete we AKD 4806 ‘AUF 400 range pump +. AKD 4807 ‘AUF 500 range pump. ” +s AKD 4808 4, Reconditioning and Testing S.U. pump testing Instructions (6.U. test rig) 6. + ee AKD 4809.4 S,U, pump reconditioning Instructions ce ee ae AKD 4810.4, pump testing instructions (Churchill es ig) sess veo AKD AB ‘Additional and revised leaflets Will be Issued from time to time. Record new Issues in the spaces provided. 2 © a -O S.U, PUMP SPECIFICATIONS General S,U, electric fuel pumps are fitted to an Increasing variety of vehiele types, calling for a wide range of installation arrangements, pressures, suctlons, and special features. The pump In each case Is a variation on a baste specification to ‘suit the particular Installatlon requirements, A current lst of pump types, specification numbers, and the Vehicles to which they are fitted, Is published as occasion arises for the use of authorized Distributors and Dealers. Basleally all $.U. fuel pumps comprise four main assemblies. 4. The body: housing the valves, filter, inlet and outlet connections. 2, Thedlaphragm: being the fuel displacement clement. ‘The coll and housing: providing the motive energy. ‘The rocker and pedestal: comprising the actuating mechanism. 49701 The diaphragm The coll and housing Earller-type pumps L, HP, LCS, Dual L, and HP and SP pumps are recorded under specification numbers, having the prefix letters AVA or AUB. All earller-type pumps in current production bear this specification number stamped on a metal plate secured under two of the coll housing screws. Any new part fitted during reconditioning must be In accordance with the particular specification, ly Externally the earlier HP pump coil housings were i in. longer than the L type. All HP pumps aro now fitted with the shortened coll housing of the same overall length as that of the L type. 49703 The body Production of the long-coil housing has ceased but it Is still used in reconditioning when a coil, similar to that used In short housing pumps, but wound on the longer core, Is used. Long and short versions of the pump are interchangeable, but because components differ, and may be required as spares, such pumps earry a prefix to the specification number, thus: ‘AUASO tong housing pump, built with short-coil housing, becomes AUA 150. AUAS2 long housing pump, bullt with short-coll housing, becomes AUA 152. ‘As the pumps are functionally Identical, In service the non= prefixed pumps may be replaced by prefixed pumps, e.g. AUA 50 by AUA 150 and vice versa. Later-type pumps ‘The AUF type of pump has been introduced to provide a simplified range using standardized parts where possible, resulting In simpler servicing. These pumps differ from earlier types mainly in the design of body and valves used. Pumps in the AUF range are always referred to by thelr specification number, 0.g. AUF 201, and not by the previous type to which they correspond thus: AUF 200 to 299 corresponds to HP and SP types, ‘AUF 300 to 399 corresponds to LCS type. ‘AUF 400 to 499 corresponds to Dual HP type. AUF 500 to 599 a new double-entry fuel pump, ‘As with the earlier-type pumps, the AUF range bear the specification number stamped on a metal plate secured under the coll housing serews. Again, any new part fitted during reconditioning must be in accordance with the particular specification, When the specification of a pump In the AUF range is altored by the addition of specially vented end-covers and coll housings, and with diaphragms of new plastic material protected by thin nylon barrier diaphragms etc., then the modified pump Is allotted another number, e.g. AUF 200 becomes AUF 201. The rocker and pedestal u AUTHORIZED DISTRIBUTOR: © QR Printed in England by The Nuteld Press Liked, Cowley, Oxlord, 24/19 (B26) 12/66—2.900 a

You might also like