LED IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS!


SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

• To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and
other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
• Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
• Installation and service of luminaires should be performed by a qualified licensed electrician.
• Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation
and any hazards involved. Regular fixture maintenance programs are recommended.
• It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient
dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm
water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly
become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
• DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been
damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
• Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
• These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency
to meet in connection with installation, operation, or maintenance. Should further information be desired or should
particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be
referred to Acuity Brands Lighting, Inc.

WARNING WARNING
RISK OF ELECTRIC SHOCK RISK OF BURN
 Disconnect or turn off power before  Allow lamp/fixture to cool before handling.
installation or servicing. Do not touch enclosure or light source.
 Verify that supply voltage is correct by  Do not exceed maximum wattage marked on
comparing it with the luminaire label luminaire label.
information.  Follow all manufacturer’s warnings,
 Make all electrical and grounded recommendations and restrictions for: driver
connections in accordance with the National type, burning position, mounting
Electrical Code (NEC) and any applicable locations/methods, replacement and
local code requirements. recycling.
 All wiring connections should be capped
with UL approved recognized wire
connectors.

CAUTION CAUTION
RISK OF INJURY RISK OF FIRE
 Wear gloves and safety glasses at all times  Keep combustible and other materials that
when removing luminaire from carton, can burn, away from lamp/lens.
installing, servicing or performing  Do not operate in close proximity to persons,
maintenance. combustible materials or substances
 Avoid direct eye exposure to the light source affected by heat or drying.
while it is on.

IN-331
LED IMPORTANT SAFETY INSTRUCTIONS

CAUTION: RISK OF PRODUCT DAMAGE

 Never connect components under load.


 Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire
insulation.
 Unless individual product specifications deem otherwise: Never connect an LED product directly to a
dimmer packs, occupancy sensors, timing devices, or other related control devices. LED fixtures must be
powered directly off a switched circuit.
 Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for
some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other
material that will prevent convection or conduction cooling.
 Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient
temperature.
 Only use fixture in its intended location.
 LED products are Polarity Sensitive. Ensure proper Polarity before installation.
 Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be
worn during all installation or servicing of the unit.
 Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter
performance.
 Some components inside the fixture may not be serviceable. In the unlikely event your unit may require
service, stop using the unit immediately and contact an ABL representative for assistance.
 Always read the fixtures complete installation instructions prior to installation for any additional fixture
specific warnings.

Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory
statements.

Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and
Conditions, please visit www.acuitybrands.com.

Our Brands Indoor/Outdoor Indoor Lighting Outdoor Lighting Controls


Lithonia Lighting Gotham American Electric Lighting DARK TO LIGHT
Carandini Mark Architectural Lighting Antique Street Lamps Lighting Control & Design
Holophane Peerless Hydrel ROAM
RELOC Renaissance Lighting Tersen Sensor Switch
Winona Lighting Synergy

Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203

© 2013 Acuity Brands Lighting, Inc. All rights reserved. 6/12/13

IN-331
American Electric Lighting a division of Acuity Brands Lighting

INSTALLATION INSTRUCTIONS
ATB2 SERIES LUMINAIRES
! WARNING
DISCONNECT POWER BEFORE RELAMPING OR WIRING THE FIXTURE.
READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION

! WARNING
RISK OF FIRE. PRODUCT FOR OUTDOOR INSTALLATION AND USE ONLY.

! CAUTION
TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL
AND LOCAL ELECTRICAL/BUILDING CODES. FOR CODE INTERPRETATION, CONSULT LOCAL CODE AUTHORITY

! CAUTION
OVER-TORQUING OF FITTER CLAMP BOLTS CAN
CREATE CRACKS IN THE HOUSING CAUSING
THE FIXTURE TO FALL TO THE GROUND.

MOUNTING / LEVELING:
DETERMINE THE SIZE OF THE MAST ARM. THIS LUMINAIRE IS
DESIGNED TO ACCOMMODATE A MAST ARM FROM 1/1/4" TO 2"
DIA. THE LUMINAIRE IS FACTORY SET TO MOUNT TO THE 1-1/4"
ARM. TO MOUNT TO A 2" ARM, A MODIFICATION MUST BE MADE.
THE REAR OPENING MUST BE ENLARGED. KNOCKOUTS ARE
CAST-IN AROUND THE REAR OPENING FOR THIS PURPOSE. TO
FITTER BOLTS MAST ARM REMOVE THIS EXCESS MATERIAL, STRIKE WITH A HAMMER OR
TERMINAL
BLOCK COVER
GRASP WITH PLIERS AND BREAK OFF.
STANDARD MOUNTING:
LOOSEN (DO NOT REMOVE) THE FITTER BOLTS. LIFT THE
LUMINAIRE INTO POSITION IN FRONT OF THE MAST ARM SUCH
THAT THE MAST ARM ENTERS THROUGH THE OPENING AT THE
REAR OF THE LUMINAIRE AND BETWEEN THE FITTER BRACKET
KNOCKOUT AND THE LUMINAIRE HOUSING. TIGHTEN FITTER BOLTS
TERMINAL TO 10-12 FT-LBS.
BLOCK

! WARNING ANGLE LEVELING:


THIS LUMINAIRE IS DESIGNED TO ADJUST ± 5 DEGREES UP OR
ENSURE THAT ALL POWER IS
DOWN SIDE. TO ADJUST THE LUMINAIRE TO THE UP SIDE, TIGHTEN
DISCONNECTED PRIOR TO WIRING
THE REAR FITTER BOLTS UNTIL GET THE DESIRED ANGLE, AND
WIRING: THEN TIGHTEN THE FRONT FITTER BOLTS TO SECURE THE
PULL UP TERMINAL BLOCK COVER (OPTIONAL) AS SHOWN IN LUMINAIRE. TO ADJUST TO THE DOWN SIDE TIGHTEN THE FRONT
THE PICTURE. FEED THE SUPPLY WIRES THROUGH THE MAST FITTER BOLTS UNTIL GET THE DESIRED ANGLE, THEN TIGHTEN THE
ARM, DRESS THEM SO THEY DO NOT INTERFERE WITH ANY REAR FITTER BOLTS TO SECURE THE LUMINAIRE.
COMPONENTS AND SO THEY WILL NOT BE PINCHED IN THE
OPTIONAL PHOTOCONTROL:
DOOR, AND CONNECT THEM TO THE PROPER TERMINALS ON
PLUG THE PHOTOCONTROL INTO THE RECEPTACLE ENSURING
THE TERMINAL BLOCK. VERIFY THE SUPPLY VOLTAGE IS
GASKET IS FIRMLY SEATED. TWIST CLOCKWISE UNTIL IT LOCKS
CORRECT AS NOTED ON THE NAMEPLATE LABEL. IF SUPPLIED,
INTO POSITION.
PUSH DOWN THE TERMINAL BLOCK COVER TO KEEP
IF PHOTOCONTROL RECEPTACLE ROTATION IS REQUIRED, LOOSEN
TERMINALS COVERED.
THE TWO PHILIPS HEAD RECEPTACLE SCREWS. ROTATE
WARNING
RECEPTACLE, MAXIMUM OF 360° , THEN RE-TIGHTEN SCREWS
! UNTIL SNUG, USING 20-25 IN-LBS OF TORQUE.
FIXTURE MUST BE GROUNDED IF PHOTOCONTROL RECEPTACLE ROTATION IS REQUIRED
TO FUNCTION AS INTENDED FOR THE P5 / P7 OPTION, LOOSEN THE TWO PHILIPS HEAD
RECEPTACLE SCREWS COMPLETELY. ROTATE RECEPTACLE 90°,
TERMINAL BLOCK: 180°, OR 270°, THEN RE-TIGHTEN SCREWS UNTIL SNUG, USING
RECOMMENDED TORQUE FOR SCREWS 35 IN-LBS. 20-25 IN-LBS OF TORQUE.

DRAWING NO. A72975 REV: A (FRONT) ©2014 ACUITY BRANDS LIGHTING, INC. ALL RIGHTS RESERVED. PART NUMBER 057-70-72975
American Electric Lighting a division of Acuity Brands Lighting

INSTALLATION INSTRUCTIONS
ATB2 SERIES LUMINAIRES
! WARNING
THIS IS AN ELCTRONIC DEVICE AND SHOULD NOT BE LEFT EXPOSED TO THE ELEMENTS
DURING STORAGE, TRANSPORTATION, OR INSTALLATION. IT IS RATED FOR OUTDOOR
USE ONCE PROPERLY INSTALLED AND IN NORMAL CONDITION.

NOTE:
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND
(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED
OPERATION.

5 YEAR LIMITED WARRANTY

DRAWING NO. A72975 REV: A (BACK) ©2014 ACUITY BRANDS LIGHTING, INC. ALL RIGHTS RESERVED. PART NUMBER 057-70-72975