0% found this document useful (0 votes)
156 views1 page

ATT-3 - Standard Fire Pump Accessories

This document provides specifications for standard fire pump accessories from Aurora Fire Pumps. It includes dimensions and notes for accessories that include gauges, air release valves, and casing relief valves. The accessories are shipped loose for field installation on fire pump systems with pipe sizes ranging from 2-1/2 inches to 12 inches.

Uploaded by

Tolgahan Karadag
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
156 views1 page

ATT-3 - Standard Fire Pump Accessories

This document provides specifications for standard fire pump accessories from Aurora Fire Pumps. It includes dimensions and notes for accessories that include gauges, air release valves, and casing relief valves. The accessories are shipped loose for field installation on fire pump systems with pipe sizes ranging from 2-1/2 inches to 12 inches.

Uploaded by

Tolgahan Karadag
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

ATT-3

AURORA FIRE PUMPS Section 916 Page 201


STANDARD FIRE PUMP ACCESSORIES Date May 2004
Supersedes Section 916 Page 201
Dated June 2002

1/2" NPT OUTLET E

FLOAT-OPERATED
AIR RELEASE VALVE

D
1/2" PIPING BY
OTHERS (SEE NOTE 5)
CASING RELIEF VALVE
3-1/2" (89) DIA. SUCTION AND 3/4" NPT OUTLET
DISCHARGE GAUGES WITH
1/4" SHUT-OFF COCKS
C
VALVE INLET SIZE "B"
(PIPING BY OTHERS)

"A" PIPE TAP IN


CASING DISCHARGE

“A”
PIPE SIZE
TAP SIZE
2-1/2-481-10
NOTES:
3-481-10 1. Dimensions are in inches (mm) and may
4-481-11 vary ± 1/4” (6).
4-481-15 2. Accessories shown are shipped loose for
field installtion.
5-481-11
3. Casing relief valve is to be adjusted to
5-481-15 appropriate pressure upon field installtion
5-481-17 1-1/4" 4. Casing relief valve is furnished on electric
6-481-11 motor driven units only.
6-481-15 CASING RELIEF VALVE 5. Two stage pumps require both vent taps
piped to air release valve.
6-481-18 VALVE 6. Suction guage range is 30”-0-150 PSI for
6-481-20 SYSTEM
INLET “C” suction pressures up to 75 PSI, or 30”-0-
8-481-12 G.P.M. 300 PSI for suction pressures over 75 PSI.
SIZE - “B”
8-481-21 7. Discharge gauge range is 0-300-PSI for
250 pumps with rated discharge pressures up
10-481-15 500 to 150 PSI, or 0-600 PSI for pumps with
8-481-17 750 rated discharge pressures over 150 PSI.
2"
10-481-18 1000 3/4” 4-1/2”
12-481-18 1250 (114)
ALL VERTICAL 3/4" 1500 FLOAT OPERATED AIR RELEASE VALVE
(483) MODELS
2000 SYSTEM
ALL 2-STAGE 1-1/4" 2500 OPERATING “D” “E”
(485) MODELS
3000 PRESSURE
490 MODELS 3/4” 1” 5-1/2”
3500 (140) UP TO 175 P.S.I. 5-7/8” (149) 3-3/4” (95)
4000 OVER 175 P.S.I. 6-11/16” (170) 5-5/8” (143)