0% found this document useful (0 votes)
106 views20 pages

Brochure Solar

This document discusses photovoltaic installation testing solutions from HT S.O.L.A.R. It describes three products: SOLAR I-V for troubleshooting, commissioning tests, and performance monitoring; I-V 400 for I-V curve testing of PV strings and modules; and SOLAR-02 for remote irradiation and temperature measurement. These products test PV system performance, detect faults, and ensure safety standards are met during installation and operation.

Uploaded by

penity
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
106 views20 pages

Brochure Solar

This document discusses photovoltaic installation testing solutions from HT S.O.L.A.R. It describes three products: SOLAR I-V for troubleshooting, commissioning tests, and performance monitoring; I-V 400 for I-V curve testing of PV strings and modules; and SOLAR-02 for remote irradiation and temperature measurement. These products test PV system performance, detect faults, and ensure safety standards are met during installation and operation.

Uploaded by

penity
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20

SOLAR

PERFECTION
H T S O L A R

Troubleshooting Commissioning Performance


tests
SOL A R
PERFECTION
Photovoltaic installations: new HT solutions for commissioning
tests, performance recording and troubleshooting.

Thanks to the decreasing cost of components, and considerable increase


in related performance, installing PV systems on roofs or even on the
ground has become more and more common. It is necessary, however,
to consider problems of installation safety, performance recording
and maintenance that may affect any PV installation.

Troubleshooting
› It may happen that during the operation of a plant, some modules could fail compromising the performance of the whole system. When the efficiency of the system is lower than
expected, it is necessary to troubleshoot the system to detect the broken modules, for further replacement. SOLAR I-V and I-V 400 are the ideal solution for troubleshooting.

Commissioning tests
› Commissioning tests are carried out to prove that the systems operate and perform to the safety specification. The standard IEC 62446 states the minimum testing
and commissioning requirements to be carried out on PV installation each time they are connected to the grid. PVCHECK is the ideal solution for commissioning tests,
as well as pre-start-up system checks.

Performance
› Performance recording is a necessary pre-requisite to make maintenance programs effective. To monitor the performance of the system allows for detection of loss
of production, to be corrected by troubleshooting and fixing the damage. SOLAR300N, SOLAR I-V and MPP300 are the ideal solution for scheduled performance
recording, as well as for loss of production investigation
H T S O L A R

SOLAR I-V
Multifunction instrument for testing single-phase PV installations.
(THREE-PHASE with accessory MPP300)

› Designed to meet any requirement of PV installation testers


› Single phase efficiency measurement
› I-V curve tracer
› Voc and Isc measurement
› Database of 30.000 PV modules curve types

Easy identification of problems on systems which are not complying


with the specifications declared by the manufacturer.
SOLAR I-V measures the efficiency of single-phase PV systems and also measures the I-V
characteristic both of a single module and of module strings on PV plants (up to a maximum
of 1000V and 10A).
Remote irradiation and temperature measurement
Irradiation and temperature measurements play an essential role for extrapolation of the I-V characteristic
under standard test conditions. SOLAR I-V carries out such measurements directly or under remote
mode through the unit SOLAR-02, synchronized with main unit. SOLAR I-V can effect measurements
at the inverter, while SOLAR-02 simultaneously detects environmental values close to modules
without using long cable extensions.
No more wasting time. It contemporarily carries out tests/recordings of 3 PV arrays.
SOLAR I-V can be interfaced with optional accessory MPP300 capable of carrying out simultaneoulsy
tests and recordings on max 3 separate arrays, typical of multi-MPPT systems and multi-inverter
systems (with MPP300).
Testing outcome: OK or NOT OK
SOLAR I-V compares the measured values with the values declared by the module manufacturer,
immediately providing the test result.
Functions
Maintenance of a PV plant


Measurement of output voltage from module/string up to 1000V DC
Measurement of output current from module/string up to 10A DC
• Measurement of solar irradiation [W/m 2 ] with reference cell HT304N
SOLAR I-V 1
• Measurement of temperature, automatic or by means of probe PT300N Detection of IV
• Measurement of output DC and nominal power from module/string characterisitc on a
• I-V curve test with direct measurement of Irr/Temp parameters stringSOLAR I-V
of PV modules
• I-V curve test by using of SOLAR-02 unit
through remote
measurement
• Measurement of the resistance of photovoltaic module series
of radiation
• Mechanical inclinometer to detect correct solar irradiation and temperature
• 4-terminal measuring method
• Comparison with standard conditions (STC 1000 W/m 2 , 25°C)
• Evaluation of testing result: OK / NO
• Management of up to 30 types of PV modules (30000 managed by PC software)
• Internal memory for data saving
• Recalling results on the display
• Optical/USB port for PC connection
• Online Help on the display
Performance of a PV plant
• DC/AC TRMS Voltage
• DC/AC TRMS Current
• DC power
• AC active power on single-phase systems
• Solar irradiation [W/m 2 ] with reference cell
• Temperature environmental and module by means of probe PT300N
SOLAR I-V 2
• Synchronization with remote unit SOLAR-02 Direct measurement
• Display of real-time irradiation and temperature of IV characteristic
• Use of relationship to correct DC efficiency through Temperature and Irradiance measuring on a string
• Recording of parameters with programmable IP (5s – 60min) of PV modules

I-V curve: OK I-V curve NOT OK

SOLAR I-V 3
Testing
of single-phase PV
installation

Performance Analysis running. Performance outcome.


H T S O L A R

I-V 400
Multifunction instrument for I-V curve test of PV strings and modules.

› I-V Curve tracer


› Voc and Isc measurement
› Database of 30.000 PV modules curve types

Immediate recording of the I-V characteristic and of the characteristic parameters


I-V400 carries out the field measurement of the I-V characteristic and of the main characteristic parameters
both of a single module and of module strings on PV plants (up to a maximum of 1000V and 10A).
Immediate compliance test result
The acquired data are then processed to extrapolate the I-V characteristic under standard test
conditions (STC) in order to proceed comparing them with the rated data declared by the modules’
manufacturer, thus immediately determining whether or not the string or the module under test
comply with the characteristics declared by the manufacturer. On the other hand the analysis of
IV curve permits to detect any fault condition on each single module composing the string under test.
Remote irradiation and temperature measurement
Irradiation and temperature measurements play an essential role for extrapolation of the I-V characteristic
under standard test conditions. I-V 400 carries out such measurements directly or under remote mode through the
optional unit SOLAR-02, synchronized with main unit. I-V 400 can effect measurements at the inverter, while
SOLAR-02 simultaneously detects environmental values close to modules without using long cable extensions.
Friendly use with possibility of continuous updating of PV modules
I-V 400 manages a database of PV modules, which can be updated at any time both via the management
software and directly on the instrument through the user interface.
Very accurate measurements even using cable extensions
Current and voltage measurements on modules or strings are effected with the 4-terminal method,
which allows extending measuring cables without requiring any resistance compensation, so providing
accurate and precise measurements.
Test outcome: OK or NOT OK
I-V 400 compares the measured values with the values declared by the module
manufacturer, immediately providing the test result.

Functions
• Measurement of output voltage from module/string up to 1000V DC
• Measurement of output current from module/string up to 10A DC
• Measurement of solar irradiation [W/m 2 ] with reference cell HT304N
• Measurement of temperature, automatic or by means of probe PT300N
• Measurement of output DC and nominal power from module/string
• Numerical and graphical display of I-V characteristic
• Measurement of the resistance of photovoltaic module series
• Mechanical inclinometer for incidence angle of solar irradiation
• 4-terminal measuring method
• Comparison with standard conditions (STC 1000 W/m 2 , 25°C)
• Evaluation of testing result: OK / NO
• Management of up to 30 types of modules in the internal database
• Internal memory for data saving
I-V 400 1
• Recalling results on the display Detection of IV
• Optical/USB port for PC connection characterisitc on a
• Help on line on the display string of PV modules
through remote
measurement
of radiation
and temperature

I-V curve Settings PV module parameters

I-V 400 2
Direct measurement
of IV characteristic
on a string
of PV modules
I-V outcome General menu
H T S O L A R

SOLAR300N
Multifunction instrument for testing efficiency on single-phase and three-phase PV plants
with single/multi strings and analysis of power quality according to EN50160.

› New touchscreen interface


› Efficiency of PV installation
› Power and energy consumption analyzer

Efficiency is the word.


SOLAR300N carries out all tests required for check of DC and AC efficiency single-phase and
three-phase photovoltaic systems..
Simultaneous measurements of electrical and environmental parameters
according to standards.
HT introduced a remote measurement device model SOLAR-02 capable of acquiring the values of quantities
such as irradiation [W/m2], temperature of modules [°C], and environment temperature [°C].
Long cables are not required.
The remote unit is synchronized with SOLAR300N and can be positioned close to PV modules
so avoiding use of long measuring cables. The values of environmental parameters measured by
the remote unit can be transferred via USB to SOLAR300N and combined with the values of electrical
parameters.
No waste of time: it contemporarily carries out tests/recordings of 3 PV arrays.
SOLAR300N can be interfaced with optional accessory MPP300 capable of carrying out simultaneoulsy
tests and recordings on max 3 separate arrays, typical of multi-MPPT systems and multi-inverter
systems.
Power analysis.
SOLAR300N is a powerful instrument to check power quality according to EN50160 (harmonic analysis,
voltage anomalies, flicker, voltage unbalance, etc..) so allowing to investigate on real reasons for inverter
disconnection from mains power. The management software TopView provides the possibility of creating
professional reports, which can be customized by adding the company’s logo, the customer’s data,
comments, etc.
Functions
SOLAR300N is an advanced
DC/AC TRMS (single-phase and three-phase) current measurement
power and energy consumption analyzer

• DC/AC (single-phase and three-phase) power measurement
• AC (single-phase and three-phase) energy measurement
• DC Measurement of power factor (cosphi) single-phase and three-phase
• Measurement of solar irradiation [W/m 2 ] with reference cell HT304N
• Measurement of temperature by means of probe PT300N
• Recording of voltage and current harmonics up to the 49 th order
PV plant performance outcome 1 HARMONICS
on instrument display
• Recording of voltage anomalies (dips, peaks)
• Flicker analysis in compliance with standard EN50160
• Recording of inrush currents with a resolution of 10ms
• Recording of voltage fast transients (spikes) with a resolution of 5us
• Complete analysis of mains quality in compliance with standard EN50160
• Numerical and graphical display of each quantity
• Recalling results on the display
2 RECORDING
ANALYSIS
• TFT colour display with touch screen
• Power supply with rechargeable Li-ION battery
• Memory extension by means of compact flash (CF card)
• Data transfer to external USB memory (memory stick)
• USB port for PC connection
• Help on line at display
3 ENERGY
CONSUMPTION
PV plant performance outcome on PC

SOLAR300N 1
SOLAR300N
connection scheme
(three-phase) 4 FLICKER

VOLTAGE
5 ANOMALIES
TRANSIENTS
& FAST

6 INRUSH
CURRENTS

7 VECTOR DIAGRAM
AND WAVE FORMS
H T S O L A R

PV CHECK
Multifunction instrument to check safety, parameters and performance of a PV plant.

› A
 utomatic test sequence (IVCK):
› Insulation check
› Isc and Voc measurement
› Continuity check of protective conductor

The perfect check-up


•  Quickand safe testing of electrical safety on a PV installation (DC section).
• C ontrol
on working of modules/strings in accordance with IEC/EN62446 guidelines.
P V CHECK carries out insulation resistance measurement of active conductors of a module, a string
• 
or a PV array according to guidelines without the need of using an external switch to short-
circuit positive and negative terminals.
P V CHECK is provided with “IV Check” mode capable of evaluating insulation, values for open
• 
circuit voltage Voc and short circuit current Isc (both referred to STC through radiation
measurement) as well as continuity of protective conductors on each string, with a single measurement.
Check of PV array performance under operating conditions
P VCHECK
•  carries out performance analysis of PV array (DC) under operating conditions
(connected to the inverter) providing an indication of the power generated and the efficiency of
the PV field depending on irradiation condition and temperature measured by the very instrument.
Testing outcome: OK or NOT OK
• P V
CHECK compares test results with the values required by standards, so granting immediate
testing outcome.
Functions
• Safety test of PV installation
• Continuity test on protective conductors with 200mA
• Insulation test with test voltage of 250, 500, 1000VDC
• DC voltage - DC current - DC Power
• Solar irradiation [W/m 2 ] with reference cell HT304N
• Environmental and module temperature by means of PT300N probe
• SOLAR-02: remote unit for irradiance and temperature measurements (RF connection).
• Recording of PV plant parameters (DC side) with programmable IP (5s – 60min)
• Use of PDC compensation ratios according to environmental and module temperature
PVCHECK 1
Insulation
• Use of relationship to maximize the DC efficiency
measurement
• Outcome OK/NO in a PV field
• Check of PV string's working
• Measurement of open circuit voltage up to 1000V DC
• Measurement of short circuit current up to 10A DC
• Measurement of temperature, automatic or by means of PT300N probe
• Mechanical inclinometer for the detection of solar radiation incidence angle
• Comparison with standard conditions (STC 1000 W/m 2 , 25°C)
• Database to manage up to 30 types of photovoltaic modules (30000 managed by PC software)
• Internal memory for data saving
• Optical/USB port for PC connection
• Help on line on display

Continuity Test Continuity Test

PVCHECK 2
Measurement
of DC efficiency
on PV installations

Insulation test IVCK: automatic test sequence


H T S O L A R

MPP300
Accessory for measuring and recording the efficiency of single-phase
and three-phase multi-string systems

› Simultaneous analysis of 3 strings


› For connection with SOLAR300N and SOLAR I-V
› Lowering of testing times

MPP300 is an innovative accessory allowing measuring and recording the main parameters which
characterize single-phase and three-phase, single-string and multi-string (up to three MPPTs)
photovoltaic systems.

Provided with a practical anti-shock hard carrying case, its light weight and small size make
it ideal for the field use.

MPP300 interfaces with SOLAR300N and SOLAR I-V for settings, to start/stop recording electrical
and environmental parameters and to enable the download of the recorded values. The master
instrument SOLAR300N or SOLAR I-V is only used in the initial and final phase of recording, and it
does not play any active role while recording electrical and environmental parameters.

The remote unit SOLAR-02 (synchronized with MPP300) is positioned next to the photovoltaic
modules for measuring environmental parameters (irradiation and temperature). Thanks to the
synchronism, it is not necessary to lay long connection cables between the environmental
probes and the instrument, hampering the operator’s movements, being a hindrance, etc., nor to use
a wireless connection between the environmental probes and the instrument, usually impossible,
because of signal attenuation due to the presence of floors, of reinforced concrete or metal structures,
etc. The synchronization between the two units guarantees the necessary contemporaneity
of measurements, the two separate and independent units make measurements comfortable and
safe under any condition.

MPP300 finds its best partner in SOLAR I-V: while MPP300 is recording the electrical and environmental
parameters, it is possible to measure the I-V characteristics of strings and modules with SOLAR
I-V, saving time and money.
Functions
• DC/AC TRMS voltage meas. (single-phase and three-phase) • Power supply with rechargeable Li-ION battery and power adapter
• DC/AC TRMS current meas. (single-phase and three-phase) • LED operating indications

1
• DC/AC power measurement (single-phase and three-phase) • USB port for connection to unit SOLAR300N

• Simultaneous measurements up to 3 strings (max 3 MPPT) • RF connection for connection to SOLAR-02 and SOLAR I-V
MPP300
• Connection with master unit SOLAR300N and SOLAR I-V • Internal memory for saving recordings
Connection diagram
› MPP300 + SOLAR300N
via USB connection
› MPP300 + SOLAR I-V
via RF connection
Light capacitive Optical Laser Visual Built-in
Touch Screen Interchangeable* Pointer* image camera* Flash LED*
Lenses

384x288
160 x120
THT 70 60 47 Up to 3
independent
cursors
Areas with
independent
cursors
High resolution
even for
moving elements
p i x e l
High resolution
for very clear
pictures
P.I.P. fusion overlay
of thermal graphical
+ visual picture*
D I G I TA L I N F R A R E D C A M E R A S

Memory Connectivity Temperature Automatic


0,06 °C
Top thermal
Range SPAN sensitivity**
−20 ➞ +400 °C adjustment

2 rechargeable IR video Audio notes Text notes Preset selection


batteries recording recorging of material
+ charger* properties

Infrared cameras in PV installation testing and maintenance


** THT47 and THT60: 0,08 °C

The new THT range is based on a highly innovative and reliable technology. These cameras
are headed to different sectors ranging from industrial to safety, building sector etc. Thanks
to innovative wide capacitive touch screen and icon display as well as high infrared
resolution 384x288 pixel and 160x120pixel, it is easier
and more intuitive to detect problems which are not visible
* THT70 and THT60 only.

to the naked eye.New THT cameras are provided with Flash


LED, laser pointer, camera for visual and PIP pictures,
interchangeable optional lenses. Hundreds of photos can be
taken as cameras are provided with 4 GB memory so enabling
to draw up reports complete with pictures, sound and
text notes. Thermal graphical analysis will be simple and fast
from now on.
Tech specs THT THT THT
› 1. IMAGING PERFORMANCE

70 60 47
Thermal
Detector type UFPA UFPA UFPA
Spectral range 8 ÷14μm 8 ÷14μm 8 ÷14μm
Resolution / Pxl size 384 x 288 pxl / 25μm 160 x 120 pxl / 25μm 160 x 120 pxl / 25μm
Thermal sensitivity <0.06 °C @ 30°C <0.08 °C @ 30°C <0.08 °C @ 30°C
Field of view (FOV) 24.6° x 18.6° (22mm lens) 29,8° x 22,6° (7.5 mm lens) 29.8° x 22.6° (7.5 mm lens)
Minimum focal distance 0.3m 0.2m 0.2m
IFOV (@1m) 1.14mrad 3.33mrad 3.33mrad
Focusing Manual on lens Manual on lens Manual on lens
Image frequency 50Hz 50Hz 50Hz
Color palettes 8 (Standard) + 10 (Customized) 8 (Standard) + 10 (Customized) 8 (Standard) + 10 (Customized)
Visible
Integrated camera CMOS sensor 640x480 pxl, FOV 62.3° CMOS sensor 640x480 pxl, FOV 62.3° -----

› 2. IMAGING / IR VIDEO DISPLAY

Display type 3.5” TFT color, capacitive touch-screen, high brightness 3.5” TFT color, capacitive touch-screen, high brightness 3.5” TFT color, capacitive touch-screen, high brightness
Infra PiP Fusion IR image inside visible & visible image inside IR IR image inside visible & visible image inside IR -----
IR Video Recording and saving on Micro SD card MPEG4 file format Recording and saving on Micro SD card MPEG4 file format Recording and saving on Micro SD card MPEG4 file format
Video output PAL / NTSC PAL / NTSC PAL / NTSC
Electronic zoom x1 ÷ x20 in continuous way x1 ÷ x20 in continuous way x1 ÷ x20 in continuous way
Image rotation 0° ÷ 360° in step of 1° 0° ÷ 360° in step of 1° 0° ÷ 360° in step of 1°

› 3. MEASUREMENT

Temperature range -20°C ÷ 400°C -20°C ÷ 400°C -20°C ÷ 400°C
Measurement unit °C, °F, °K °C, °F, °K °C, °F, °K
Accuracy ±2 % reading or ±2°C ±2% reading or ±2°C ±2% reading or ±2°C
Measurement cursors 3 (selection temperature MIN, MAX, Customized position on image) 3 (selection temperature MIN, MAX, Customized position on image) 3 (selection temperature MIN, MAX, Customized position on image)
Laser pointer Class 2 according to IEC 60825-1 Class 2 according to IEC 60825-1 -----
Built-in illuminator White light LED White light LED -----
Measurement modes Automatic / Manual / Histogram Automatic / Manual / Histogram Automatic / Manual / Histogram
Emissivity correction 0.01 ÷ 1.00 + built-in table with common materials 0.01 ÷ 1.00 + built-in table with common materials 0.01 ÷ 1.00 + built-in table with common materials
Measurement features Automatic correction based on distance, relative humidity, Automatic correction based on distance, relative humidity, Automatic correction based on distance, relative humidity,
atmospheric temperature, offset atmospheric temperature, offset atmospheric temperature, offset
Advanced analysis Spots (max 3), Lines (max 2), Areas (max 3), Isotherm Spots (max 3), Lines (max 2), Areas (max 3), Isotherm Spots (max 3), Lines (max 2), Areas (max 3), Isotherm
Alarm on temperature Associated to measurements spots Associated to measurements spots Associated to measurements spots
SOLAR I-V I-V 400 SOLAR300N PV CHECK MPP300

Tech specs
DISPLAY AND MEMORY
Display Features 128x128pxl LCD with backlight 128x128pxl LCD with backlight Graphic 64k color TFT touch screen 128x128pxl LCD with backlight -----
with backlight and adjustable contrast
Internal Memory capacity 256 kbytes 256 kbytes 15MB 256 kbytes 2Mbytes
External memory ----- ----- USB memory stick / CF Card ----- -----
Max 99 yield tests; 249 curves 249 curves (I-V curve test), 1 month @ IP=15min, 251 par Max 999 tests -----
Saved data (I-V curve test), 999 IVCK 999 IVCK
POWER SUPPLY
6x1.5V alkaline batteries type LR6, 6x1.5V alkaline batteries type LR6, Li-ION, 3.7V recheargeable battery 6x1.5V alkaline batteries type LR6, Li-ION, 3.7V recheargeable battery
Internal power supply
AA, AM3, MN 1500 AA, AM3, MN 1500 AA, AM3, MN 1500
External power supply ----- ----- 110V/230V AC 50/60Hz to 5V DC adapter ----- 110V/230V AC 50/60Hz to 5V DC adapter
Battery duration > 249 curves (I-V curve test), > 249 curves (I-V curve test), > 6 hours Approx. 120 hours (DC efficiency test) > 3 hours
999 IVCK tests, approx. 120 h (yield test) 999 IVCK tests
SOLAR-02 max recording time Approx 1.5h (@ IP=5s) Approx 1.5h (@ IP=5s) Approx 1.5h (@ IP=5s) Approx 1.5h (@ IP=5s) Approx 1.5h (@ IP=5s); approx 8 days (@ IP=600s)
Auto power Off idleness After 5 mins. After 5 mins. After 5 mins. (no external power) After 5 mins. -----
CHARACTERISTICS OF RADIO MODULE
Frequency range 2.400 ÷ 2.4835 GHz 2.400 ÷ 2.4835 GHz ----- 2.400 ÷ 2.4835 GHz 2.400 ÷ 2.4835 GHz
R&TTE category Class 1 Class 1 ----- Class 1 Class 1
Max transmission power 30µW 30µW ----- 30µW 30µW
Max RF connection distance 1m 1m ----- 1m 1m
OUTPUT INTERFACE
PC communication port Optical/USB Optical/USB USB Optical/USB -----
Wireless RF interface (max distance 1m) Connection with SOLAR-02 Connection with SOLAR-02 Connection with SOLAR-02 Connection with SOLAR-02 Connection with SOLAR I-V and SOLAR-02
USB interface ------ ------ For USB memory sticks ------ Connection with SOLAR300N
Integration Period (IP) 5s to 60min ------ 1s to 60min 5s to 60min 5s to 60min
Operative system ------ ------ Windows CE ------ ------
MECHANICAL FEATURES
Dimensions (L x W x H) and weight 235 x165 x 75 mm - 1.2 kg 235 x165 x 75 mm - 1.2 kg 235 x165 x 75 mm - 1.0 kg 235 x165 x 75 mm - 1.2 kg 300 x265 x 140 mm - 2.3 kg
Encapsulation IP40 IP40 IP40 IP40 IP65
ENVIRONMENTAL CONDITIONS
Reference temperature 23°C ± 5°C 23°C ± 5°C 23°C ± 5°C 23°C ± 5°C 23°C ± 5°C
Working temperature 0° ÷ 40°C 0° ÷ 40°C 0° ÷ 40°C 0° ÷ 40°C 0° ÷ 40°C
Working humidity < 80% HR < 80% HR < 80% HR < 80% HR < 80% HR
Storage temperature (batt. not incl.) -10 ÷ 60°C -10 ÷ 60°C -10 ÷ 60°C -10 ÷ 60°C -10 ÷ 60°C
Storage humidity < 80% HR < 80% HR < 80% HR < 80% HR < 80% HR
REFERENCE STANDARDS
Safety IEC/EN 61010-1 IEC/EN 61010-1 IEC/EN 61010-1 IEC/EN 61010-1 IEC/EN 61010-1
Safety of measurement accessories IEC/EN 61010-031 IEC/EN 61010-031 IEC/EN 61010-031, IEC/EN 61010-2-032 IEC/EN 61010-031 IEC/EN 61010-031
IEC/EN 62446 (IVCK)
IEC/EN 60891 (I-V curve) IEC/EN 60891 (I-V curve) ----- IEC/EN 60904-5 (Temperature measurement) -----
Measurements
IEC/EN 60904-5 (Temperature measurement) IEC/EN 60904-5 (Temperature measurement) IEC/EN 61557-1,-2,-4 (LOWΩ, MΩ)
Insulation Double insulation Double insulation Double insulation Double insulation Double insulation
Pollution degree 2 2 2 2 2
Overvoltage category CAT II 1000V DC, CAT III 300V AC to ground CAT II 1000V DC, CAT III 300V AC to ground CAT IV 600V to ground, CAT III 1000V DC, CAT III 1000V DC, Max 1000V between DC inputs
Max 1000V between inputs P1,P2,C1,C2 Max 1000V between inputs P1,P2,C1,C2 Max 1000V between inputs Max 1000V DC among inputs P, N, E, C CAT IV 300V AC to ground, Max 600V beween AC inputs
Max altitude of use 2000 m 2000 m 2000 m 2000 m 2000 m
Power quality ----- ----- IEC/EN50160 ----- -----
Measurement performance ----- ----- IEC/EN61000-4-30 class B ----- -----
Flicker ----- ----- IEC/EN61000-4-15, IEC/EN50160 ----- -----
Unbalance ----- ----- IEC/EN61000-4-7, IEC/EN50160 ----- -----
Cross references SOLAR I-V I-V 400 SOLAR300N PV CHECK MPP300

Continuity of protective conductors with 200mA •


Insulation with test voltages of 50, 100, 250, 500, 1000V DC • (250, 500, 1000)
String mode and field mode insulation •
Phase sequence •
DC/AC TRMS voltage/current on single-phase systems • • • (DC only) •
DC/AC TRMS voltage/current on three-phase systems • • (DC only) •
DC/AC powers on single-phase systems • • • (DC only) •
DC/AC powers on three-phase systems • • (DC only) •
Power factor (cos ) on single-/three-phase systems •
Energies on single-phase and three-phase systems •
Recording of mains parameters with programmable IP • (5s - 60m) • (1s-60m) • (5s-60m)
Maximum number of quantities contemporarily selectable 9 251 5
Harmonic analysis of voltages/currents up to the 49th order •
Detection of voltage anomalies (dips, peaks) in 10ms •
Complete analysis according to EN50160 •
Inrush current of electric motors •
Voltage fast transients (spikes) with a resolution of 5μs (200kHz) •
Voltage unbalance (NEG%, ZERO%) and Flicker (Pst, Plt) •
Display of vector diagrams and waveforms of voltages/currents •
Indication of recording autonomy •
Default and customizable recordings •
TFT touch-screen colour display •
LCD custom backlit display • • •
Power supply by rechargeable battery and by means of external power supplier • •
Use of remote unit • • • • •
Efficiency measurement/recording of single-string system • • • • (DC only) •
Efficiency measurement/recording of multi-string system up to 3 MPPTs • (with MPP300) • (with MPP300) •
Efficiency measurement/recording of single-phase system • • •
Efficiency measurement/recording of three-phase system • (with MPP300) • •
Irradiation measurement with reference solar cell • • • •
Temperature measurement of modules and environment • • • •
Detection of I-V curve of modules and strings • (1000V, 10A) • (1000V, 10A)
Quick test mode • (1000V, 10A) • (1000V, 10A) • (1000V, 10A)
Internal database of PV modules • • •
Measurement of modules and strings data (Voc, Vmpp, Impp, Isc,
• • • (Voc, Isc)
Pmax, FF, Dpmax)
Auto power off • • • • •
Memory capacity > 200 curves 8 days @ PI=10 min > 200 curves 1 month @ PI=15 min, 251 par 999 locations 2 Mbyte
Extension of internal memory with external Compact Flash •
USB port for connection of external memory sticks •
PC interface with software for Windows • (optical/USB) • (optical/USB) • (USB) • (optical/USB)
Context-sensitive help on the display • • • •
Saving of recordings and instant values • • • •
Dimensions (L x W x H) (mm) 235x165x75 235x165x75 235x165x75 235x165x75 300x265x140
Weight (batteries included) 1,3 Kg 1,2 Kg 1 Kg 1,2 Kg 2,3 kg
Safety in compliance with IEC/EN61010-1 • • • • •
Accessories SOLAR I-V I-V 400 SOLAR300N PV CHECK MPP300

PT300N PT1000 probe for cell temperature measurement


SOLAR-02 Remote unit for irradiance/temperature
KITGSC4 Set 4 cables + 4 alligator clips
KITPVMC3 Set of 2 adapters MC3 compliance
KITPVMC4 Set of 2 adapters MC4 compliance
KIT800 Set of 5 cables + 5 alligator clips
KITMPPACC Set of 4 alligator clips for AC voltage measure
KITMPPACW Set of 4 cables for AC voltage measurement, 2m
KITMPPDCC Set of 2 alligator clips for DC voltage, 3 pcs
KITMPPDCW Set of 2 cables for DC voltage measurement, 3 pcs
A0055 External adapter AC/DC recharging battery
YABAT0003HT0 Li-ION rechargeable battery
PT400 Stylus
HT304N Reference cell for radiation measurements
M304 Mechanical inclinometer
HT4004N Transducer clamp 10-100A DC
HT4005K Transducer clamp for AC current up to 200A
TOPVIEW2006 Windows softw. + optical/USB cable C2006
TOPVIEW2007 Windows softw. + optical/USB cable
C2007 USB Cable
BORSA2051 Soft carrying bag
ISO9000 calibration certificate
User Manual
Quick reference guide
SP-0400 Set of straps for use of meter on neck
KITPVEXT25M Set of 2 4mm banana cables, Green/Black, 25m l.
VA400 Hard carrying case
VA500 Hard carrying case
MPP300 Accessory for checks of SP/TP multi-string plants
HT96U Standard clamp 1-100-1000A AC, diameter 54mm
HT97U Standard clamp 10-100-1000A AC, diameter 54mm
HT98U Standard clamp 1000A DC, diameter 50mm
HTFLEX33D Flex clamp 3000A, for use as analyzer only
HP30D1 Standard clamp with wide jaws up to 1000A DC
HP30C3 Standard clamp 3000A AC, diameter 70mm
HP30C2 Standard clamp 200-2000A AC, diameter 70mm
HT4004P Standard clamp 10-100A DC, only for use with MPP300
HT903 Accessory for connection to external CTs
606-IECN Connector with magnetic test lead
ACON3F4M Adapter for connection of DC clamps to MPP300
HT4004 Standard clamp for DC current up to 100A

S = STANDARD O = OPTIONAL
VA400

SOLAR-02 HT304N

M304

Accessories
Standard & Optional

HT4004 HP30C2
KITPVMC3 & KITPVMC4

HT4005K
HT4004N HT98U

HP30D1

PT300N 606-IECN HT96U


bsh­_fotovoltaic2014_EN1-00
M A D E
I N
I T A L Y

HT ITALIA S.R.L. HT INSTRUMENTS AMERICAS LLC HT INSTRUMENTS GMBH HT INSTRUMENTS SA


Via della Boaria, 40 3145 Bordentown Avenue Am Waldfriedhof, 1b C/ Legalitat, 89
48018 Faenza (RA) I t a l i a W3, Parlin, NJ 08879 D-41352 Korschenbroich, Deutschland 08024 Barcelona, España
T +39 0546 621002 USA Tel. + 49 (0)2161 564 581 Tel. +34 93 4081777
F +39 0546 621144 Tel. 1 719 421 9323 Fax + 49 (0)2161 564 583 Fax +34 93 4083630
E-mail [email protected] E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
ht-instruments.it ht-instruments.us ht-instruments.de ht-instruments.es

You might also like