Brochure Solar
Brochure Solar
PERFECTION
H T S O L A R
Troubleshooting
› It may happen that during the operation of a plant, some modules could fail compromising the performance of the whole system. When the efficiency of the system is lower than
expected, it is necessary to troubleshoot the system to detect the broken modules, for further replacement. SOLAR I-V and I-V 400 are the ideal solution for troubleshooting.
Commissioning tests
› Commissioning tests are carried out to prove that the systems operate and perform to the safety specification. The standard IEC 62446 states the minimum testing
and commissioning requirements to be carried out on PV installation each time they are connected to the grid. PVCHECK is the ideal solution for commissioning tests,
as well as pre-start-up system checks.
Performance
› Performance recording is a necessary pre-requisite to make maintenance programs effective. To monitor the performance of the system allows for detection of loss
of production, to be corrected by troubleshooting and fixing the damage. SOLAR300N, SOLAR I-V and MPP300 are the ideal solution for scheduled performance
recording, as well as for loss of production investigation
H T S O L A R
SOLAR I-V
Multifunction instrument for testing single-phase PV installations.
(THREE-PHASE with accessory MPP300)
SOLAR I-V 3
Testing
of single-phase PV
installation
I-V 400
Multifunction instrument for I-V curve test of PV strings and modules.
Functions
• Measurement of output voltage from module/string up to 1000V DC
• Measurement of output current from module/string up to 10A DC
• Measurement of solar irradiation [W/m 2 ] with reference cell HT304N
• Measurement of temperature, automatic or by means of probe PT300N
• Measurement of output DC and nominal power from module/string
• Numerical and graphical display of I-V characteristic
• Measurement of the resistance of photovoltaic module series
• Mechanical inclinometer for incidence angle of solar irradiation
• 4-terminal measuring method
• Comparison with standard conditions (STC 1000 W/m 2 , 25°C)
• Evaluation of testing result: OK / NO
• Management of up to 30 types of modules in the internal database
• Internal memory for data saving
I-V 400 1
• Recalling results on the display Detection of IV
• Optical/USB port for PC connection characterisitc on a
• Help on line on the display string of PV modules
through remote
measurement
of radiation
and temperature
I-V 400 2
Direct measurement
of IV characteristic
on a string
of PV modules
I-V outcome General menu
H T S O L A R
SOLAR300N
Multifunction instrument for testing efficiency on single-phase and three-phase PV plants
with single/multi strings and analysis of power quality according to EN50160.
SOLAR300N 1
SOLAR300N
connection scheme
(three-phase) 4 FLICKER
VOLTAGE
5 ANOMALIES
TRANSIENTS
& FAST
6 INRUSH
CURRENTS
7 VECTOR DIAGRAM
AND WAVE FORMS
H T S O L A R
PV CHECK
Multifunction instrument to check safety, parameters and performance of a PV plant.
› A
utomatic test sequence (IVCK):
› Insulation check
› Isc and Voc measurement
› Continuity check of protective conductor
PVCHECK 2
Measurement
of DC efficiency
on PV installations
MPP300
Accessory for measuring and recording the efficiency of single-phase
and three-phase multi-string systems
MPP300 is an innovative accessory allowing measuring and recording the main parameters which
characterize single-phase and three-phase, single-string and multi-string (up to three MPPTs)
photovoltaic systems.
Provided with a practical anti-shock hard carrying case, its light weight and small size make
it ideal for the field use.
MPP300 interfaces with SOLAR300N and SOLAR I-V for settings, to start/stop recording electrical
and environmental parameters and to enable the download of the recorded values. The master
instrument SOLAR300N or SOLAR I-V is only used in the initial and final phase of recording, and it
does not play any active role while recording electrical and environmental parameters.
The remote unit SOLAR-02 (synchronized with MPP300) is positioned next to the photovoltaic
modules for measuring environmental parameters (irradiation and temperature). Thanks to the
synchronism, it is not necessary to lay long connection cables between the environmental
probes and the instrument, hampering the operator’s movements, being a hindrance, etc., nor to use
a wireless connection between the environmental probes and the instrument, usually impossible,
because of signal attenuation due to the presence of floors, of reinforced concrete or metal structures,
etc. The synchronization between the two units guarantees the necessary contemporaneity
of measurements, the two separate and independent units make measurements comfortable and
safe under any condition.
MPP300 finds its best partner in SOLAR I-V: while MPP300 is recording the electrical and environmental
parameters, it is possible to measure the I-V characteristics of strings and modules with SOLAR
I-V, saving time and money.
Functions
• DC/AC TRMS voltage meas. (single-phase and three-phase) • Power supply with rechargeable Li-ION battery and power adapter
• DC/AC TRMS current meas. (single-phase and three-phase) • LED operating indications
1
• DC/AC power measurement (single-phase and three-phase) • USB port for connection to unit SOLAR300N
• Simultaneous measurements up to 3 strings (max 3 MPPT) • RF connection for connection to SOLAR-02 and SOLAR I-V
MPP300
• Connection with master unit SOLAR300N and SOLAR I-V • Internal memory for saving recordings
Connection diagram
› MPP300 + SOLAR300N
via USB connection
› MPP300 + SOLAR I-V
via RF connection
Light capacitive Optical Laser Visual Built-in
Touch Screen Interchangeable* Pointer* image camera* Flash LED*
Lenses
384x288
160 x120
THT 70 60 47 Up to 3
independent
cursors
Areas with
independent
cursors
High resolution
even for
moving elements
p i x e l
High resolution
for very clear
pictures
P.I.P. fusion overlay
of thermal graphical
+ visual picture*
D I G I TA L I N F R A R E D C A M E R A S
The new THT range is based on a highly innovative and reliable technology. These cameras
are headed to different sectors ranging from industrial to safety, building sector etc. Thanks
to innovative wide capacitive touch screen and icon display as well as high infrared
resolution 384x288 pixel and 160x120pixel, it is easier
and more intuitive to detect problems which are not visible
* THT70 and THT60 only.
Tech specs
DISPLAY AND MEMORY
Display Features 128x128pxl LCD with backlight 128x128pxl LCD with backlight Graphic 64k color TFT touch screen 128x128pxl LCD with backlight -----
with backlight and adjustable contrast
Internal Memory capacity 256 kbytes 256 kbytes 15MB 256 kbytes 2Mbytes
External memory ----- ----- USB memory stick / CF Card ----- -----
Max 99 yield tests; 249 curves 249 curves (I-V curve test), 1 month @ IP=15min, 251 par Max 999 tests -----
Saved data (I-V curve test), 999 IVCK 999 IVCK
POWER SUPPLY
6x1.5V alkaline batteries type LR6, 6x1.5V alkaline batteries type LR6, Li-ION, 3.7V recheargeable battery 6x1.5V alkaline batteries type LR6, Li-ION, 3.7V recheargeable battery
Internal power supply
AA, AM3, MN 1500 AA, AM3, MN 1500 AA, AM3, MN 1500
External power supply ----- ----- 110V/230V AC 50/60Hz to 5V DC adapter ----- 110V/230V AC 50/60Hz to 5V DC adapter
Battery duration > 249 curves (I-V curve test), > 249 curves (I-V curve test), > 6 hours Approx. 120 hours (DC efficiency test) > 3 hours
999 IVCK tests, approx. 120 h (yield test) 999 IVCK tests
SOLAR-02 max recording time Approx 1.5h (@ IP=5s) Approx 1.5h (@ IP=5s) Approx 1.5h (@ IP=5s) Approx 1.5h (@ IP=5s) Approx 1.5h (@ IP=5s); approx 8 days (@ IP=600s)
Auto power Off idleness After 5 mins. After 5 mins. After 5 mins. (no external power) After 5 mins. -----
CHARACTERISTICS OF RADIO MODULE
Frequency range 2.400 ÷ 2.4835 GHz 2.400 ÷ 2.4835 GHz ----- 2.400 ÷ 2.4835 GHz 2.400 ÷ 2.4835 GHz
R&TTE category Class 1 Class 1 ----- Class 1 Class 1
Max transmission power 30µW 30µW ----- 30µW 30µW
Max RF connection distance 1m 1m ----- 1m 1m
OUTPUT INTERFACE
PC communication port Optical/USB Optical/USB USB Optical/USB -----
Wireless RF interface (max distance 1m) Connection with SOLAR-02 Connection with SOLAR-02 Connection with SOLAR-02 Connection with SOLAR-02 Connection with SOLAR I-V and SOLAR-02
USB interface ------ ------ For USB memory sticks ------ Connection with SOLAR300N
Integration Period (IP) 5s to 60min ------ 1s to 60min 5s to 60min 5s to 60min
Operative system ------ ------ Windows CE ------ ------
MECHANICAL FEATURES
Dimensions (L x W x H) and weight 235 x165 x 75 mm - 1.2 kg 235 x165 x 75 mm - 1.2 kg 235 x165 x 75 mm - 1.0 kg 235 x165 x 75 mm - 1.2 kg 300 x265 x 140 mm - 2.3 kg
Encapsulation IP40 IP40 IP40 IP40 IP65
ENVIRONMENTAL CONDITIONS
Reference temperature 23°C ± 5°C 23°C ± 5°C 23°C ± 5°C 23°C ± 5°C 23°C ± 5°C
Working temperature 0° ÷ 40°C 0° ÷ 40°C 0° ÷ 40°C 0° ÷ 40°C 0° ÷ 40°C
Working humidity < 80% HR < 80% HR < 80% HR < 80% HR < 80% HR
Storage temperature (batt. not incl.) -10 ÷ 60°C -10 ÷ 60°C -10 ÷ 60°C -10 ÷ 60°C -10 ÷ 60°C
Storage humidity < 80% HR < 80% HR < 80% HR < 80% HR < 80% HR
REFERENCE STANDARDS
Safety IEC/EN 61010-1 IEC/EN 61010-1 IEC/EN 61010-1 IEC/EN 61010-1 IEC/EN 61010-1
Safety of measurement accessories IEC/EN 61010-031 IEC/EN 61010-031 IEC/EN 61010-031, IEC/EN 61010-2-032 IEC/EN 61010-031 IEC/EN 61010-031
IEC/EN 62446 (IVCK)
IEC/EN 60891 (I-V curve) IEC/EN 60891 (I-V curve) ----- IEC/EN 60904-5 (Temperature measurement) -----
Measurements
IEC/EN 60904-5 (Temperature measurement) IEC/EN 60904-5 (Temperature measurement) IEC/EN 61557-1,-2,-4 (LOWΩ, MΩ)
Insulation Double insulation Double insulation Double insulation Double insulation Double insulation
Pollution degree 2 2 2 2 2
Overvoltage category CAT II 1000V DC, CAT III 300V AC to ground CAT II 1000V DC, CAT III 300V AC to ground CAT IV 600V to ground, CAT III 1000V DC, CAT III 1000V DC, Max 1000V between DC inputs
Max 1000V between inputs P1,P2,C1,C2 Max 1000V between inputs P1,P2,C1,C2 Max 1000V between inputs Max 1000V DC among inputs P, N, E, C CAT IV 300V AC to ground, Max 600V beween AC inputs
Max altitude of use 2000 m 2000 m 2000 m 2000 m 2000 m
Power quality ----- ----- IEC/EN50160 ----- -----
Measurement performance ----- ----- IEC/EN61000-4-30 class B ----- -----
Flicker ----- ----- IEC/EN61000-4-15, IEC/EN50160 ----- -----
Unbalance ----- ----- IEC/EN61000-4-7, IEC/EN50160 ----- -----
Cross references SOLAR I-V I-V 400 SOLAR300N PV CHECK MPP300
S = STANDARD O = OPTIONAL
VA400
SOLAR-02 HT304N
M304
Accessories
Standard & Optional
HT4004 HP30C2
KITPVMC3 & KITPVMC4
HT4005K
HT4004N HT98U
HP30D1