VRF - Heat Recorvery (FSXNP & FSXNS Series)
VRF - Heat Recorvery (FSXNP & FSXNS Series)
SET FREE Σ
–
Johnson Controls-Hitachi Air Conditioning Vietnam LLC
– –
Head Office - Ho Chi Minh Office CERTIFICATION
Floor 6, Royal Tower B, 235 Nguyen Van Cu St.,
Nguyen Cu Trinh Ward, Dist. 1, Ho Chi Minh City ISO 9000 series
Telephone: (84.28)36222646 Fax: (84.28) 36362165 Shimizu Air Conditioning Headquarters, Professional-Use Air Conditioning
Business Division, Johnson Controls – Hitachi Air Conditioning
Da Nang Office JQA-1084 obtained in November 1995
Floor 9, Thanh Loi Tower, 249 Nguyen Van Linh,
Vinh Trung Ward, Thanh Khe Dist., Da Nang City ISO 14000 series
Telephone: (84.236) 3565 230
EC97J1107 obtained in October 1997
Ha Noi Office
Floor 2, Thang Long Tower, 98A Nguy Nhu Kon Tum, –
Nhan Chinh Ward, Thanh Xuan Dist., Ha Noi City WARRANTY
Telephone: (84.24) 37 723 478 Fax: (84.24) 37 723 480
Training Center
Floor 8, Standard Factory B, Tan Thuan EPZ, Dist. 7,
Ho Chi Minh City WARRANTY COMPRESSOR
Email: [email protected]
Website: hitachiaircon.vn www.hitachi-ap.co.jp
Hotline: 18006202
SET FREE Σ
Cooling & Heating to incorporate the latest innovations for its customers. The
information contained in this catalog is merely informative. Hitachi Cooling & Heating
declines any responsibility in the broadest sense, for damage, direct or indirect, arising
from the use and / or interpretation of the recommendations in this catalog.
–
Index
08 Welcome
41 Outdoor units
INDEX
113 Control systems
153
02 03
–
Glossary
GLOSSARY
– RCS Group
FSXNP Series Remote Controller System Group.
Premium series of air source VRF, Heat Recovery
type (simultaneous heating & cooling operation), –
HP Class
Horsepower Class.
–
FSXNS Series –
Standard series of air source VRF, Heat Recovery PCB
type (simultaneous heating & cooling operation), Printed circuit board.
standard model.
04 05
Living
Harmony
06
07
WELCOME
The beauty of balance
08 09
SET FREE Σ – FSXNP & FSXNS SERIES
–
We live & breathe innovation
WELCOME
–
Living Harmony
10 11
Your world.
together.
We live in it
12
13
and Hitachi
buildings, Hitachi technology lets you create
a relaxing atmosphere at home, improve
–
Learn more about our
controllers on page 112
– –
Change in the air Design for tomorrow’s
urban spaces
Change is one of the few constants in life.
Around the world, urban space is under
The world around us changes continuously increasing pressure. By using less space for
and as it does, so do our own comfort levels cooling and heating, more can be available for
living. With smaller footprints and compact case
and our requirements of our buildings.
WELCOME
designs, our new generation indoor and outdoor
units give architects, building managers and
owners greater levels of freedom and flexibility
Creating harmony in the face of change has than ever before.
always been the driving force behind Hitachi –
Cooling & Heating. From maintaining a Learn more about our
small footprint outdoor
perfect indoor climate as the seasons change, units on page 53
–
Learn more about heat
recovery on page 26
14 15
–
The shape of
things to come
–
We’ve named our latest
VRF system SET FREE Σ
Continuing the evolution of the SET FREE
series, the sigma symbol (Σ) references the
shape of our revolutionary, ultra-efficient
new heat exchanger.
–
To learn more about our heat
exchanger technology, please refer to
page 25.
16 17
–
Introducing
Hitachi VRF
–
Helping you create
perfect indoor balance
– –
The interior spaces where people work, play, Designing beautiful air For building occupants
sleep and relax are as individual as they are
WELCOME
and the way they are used is every bit as The philosophy of Living Harmony shapes Our systems are designed to ensure
everything we do, but it’s really not about us. superior comfort levels by maintaining a
unique as their design. The design of our Variable Refrigerant Flow constant and balanced room temperature.
(VRF) systems starts with truly understanding
the needs of our customers; the people
At Hitachi Cooling & Heating, we understand who use, specify and install our products.
that everyone needs their own space.
So, wherever you go in the world, we have
a solution to help create and maintain a
perfectly balanced interior environment.
– –
For architects, For building owners,
designers and engineers managers and installers
18 19
–
WELCOME
–
SET FREE Σ
From Dublin to Dubai, people rely on Hitachi
Cooling & Heating to work more productively, play
and relax in comfort and sleep soundly. That’s
why our “SET FREE” range is designed to perform
faultlessly under the most challenging conditions,
with every component manufactured and tested to
the highest tolerance levels.
20 21
SET FREE Σ – FSXNP & FSXNS SERIES
–
Our past shapes
the future
In 1952 a small team of Japanese engineers
set out to realize a unique vision: to help
people around the world create their perfect
indoor environment.
–
Performance taken
WELCOME
to new levels
Smooth Drive is the world-leading compressor
control technology at the heart of SET FREE Σ.
22 23
–
Our heritage in
Cooling & Heating
MAIN PRODUCTS
WELCOME
1943
1951
1952
1956
1958
1961
1963
1965
1970
1971
1972
1973
1976
1978
1979
1981
1982
1983
1984
1986
1988
1990
1991
1996
1999
2003
2005
2011
2012
2016
Roller for mill
Indoor unit: Centrifugal VRF:
1st air-cooled Unitary an “Outdoor unit”
Shimizu Factory Wall Mounted VRF 2ND GENERATION
Large Split for export made for indoor
founded Outdoor unit: type (RPK) –
market 5HP 8HP & 10HP installation
for low-ambient Hitachi’s 1st Inverter-
temperature driven VRF with built- VRF 4TH GENERATION
markets in Scroll Compressor 10 HP
Large casting Hitachi’s 1st Packaged –
fan for tunnel AC (Water-cooled Up to 8 indoor units (130% capacity)
Floor Standing type) World 1st IGBT built-in Inverter
VRF achieves quietest operation
24 25
–
What is –
Simultaneous cooling to lower energy costs in the mid-season. Use of exhaust heat
WELCOME
units, with the exception of fresh air units.
Heating Cooling Everyone experiences temperature differently.
Some of us might find a room too warm while
for others, it’s a bit chilly. This depends not only
on the individual, but on other factors, such as
exposure to direct sunlight. With Heat Recovery,
every person can benefit from localized cooling or
Set temperature : 23°C Set temperature : 19°C heating, based on their preferred set temperature.
High Pressure Gas
Low Pressure Gas
Liquid Gas
Multi-Port CH-Box Not in operation
Open valve
Closed valve
–
Consistent temperature in
large zones Single-Port
CH-Box
Single-Port
CH-Box
Single-Port
CH-Box
Single-Port
CH-Box
The SET FREE Σ Heat Recovery range allows Cooling Heating Heating Cooling
simultaneous cooling and heating, even within
the same zone of the same refrigerant system.
26 27
–
Your spaces
and SET FREE Σ
WELCOME
and needs Hotels In the ambient atmosphere of an hotel,
guest comfort is paramount. VRF technology
with Heat Recovery provides the perfect
From designer hotels, to busy offices
solution, offering fine control over each room,
and hospitals or cultural and heritage
coupled with outstanding reliability and
buildings, each has its own unique
energy savings.
heating and cooling requirements.
• Heat Recovery systems offer simultaneous cooling
and heating to meet individual guest needs
• Heat Recovery delivers additional energy
savings, helping to reduce hotel running costs
• Wide range of indoor units for guest rooms
(ducted), corridors (2 or 1-way cassettes)
and venues (4-way cassette)
• Central Station controllers provide easy monitoring
of guest room air conditioning
• Simple and intuitive PC-ARH1 remote controllers
are ideal for guest use
28 29
SET FREE Σ – FSXNP & FSXNS SERIES
– – – –
WELCOME
Offices Hitachi Cooling & Heating gives you the Hospitals A busy hospital relies on cooling and
precise control needed to create a productive heating equipment to perform reliably
and efficient working environment. every day. SET FREE Σ units deliver the
unfailing reliability and easy management
• During cold months, server rooms are cooled and maintenance demanded by the
using the exhaust energy from heated rooms
healthcare industry.
• Meeting rooms quickly reach set temperatures
after switching on
• Simultaneous heating and cooling meets individual
• Energy saving motion sensor option enables patient needs
automatic turn off during room vacancy
• System backup ensures uninterrupted operation
• Real time measurement of each tenant’s in the event of individual unit failure
energy consumption
• Improved air quality with the addition of the
• High energy efficiency ratings contribute fresh air intake option for indoor units
to green building certification
• Low noise operation for outdoor units with
a three-step night silent mode available
to preserve the exterior environment
30 31
SET FREE Σ – FSXNP & FSXNS SERIES
– –
WELCOME
Heritage & In historical or culturally significant buildings,
cultural buildings a retrofitted system needs to be effective and
most importantly, non-invasive.
32 33
– –
For architects &
Features & system designers
benefits for
Your perspective shapes the world
we live in together. Our cooling and
customers
with your vision.
WELCOME
for outdoor units
• Pipe runs up to 1,000m
This table sets out the features and ✓ No outdoor noise disturbance
✓ Fits almost all buildings
benefits of the SET FREE Σ range with Ambient temperature range
your needs in mind. • -20°C DB to 52°C DB (FSXNP series) Outdoor unit modular components
• Various components can be added or changed
• -20°C DB to 48°C DB (FSXNS series)
✓ Customization to each project
• Heat Recovery: -5°C DB to 24°C DB
✓
✓ Suitable for a wide range of climates
Ducted systems
Non-ducted systems
•
• Makes the most of direct expansion
duct infrastructure
• Requires less clearance between
• Up to 200Pa High ESP ducted indoor unit
34 35
– –
For contractors For building
& installers owners
Your skill ensures that our cooling You provide the spaces for our cooling
and heating systems run perfectly. and heating systems. We design them
_
System
WELCOME
ports addition ✓ Quieter operation
• The upper panel (electric box) independently Three step silent mode
✓ Friendly for craning detaches from the lower panel (compressor ✓ Lighter maintenance process
• Available function to limit the noise of outdoor
chamber) units (three step)
Design for convenience • All PCBs are visible, easily accessible and ✓ Ideal for locations with restrictions on
• Pipes to the outdoor units can be connected include a 7-segment display noise pollution
from the front, back, or underneath
• Optimized valve and piping position for easy
• Compact and light indoor units for easy maintenance Smooth Drive technology
handling
• Refrigerant evacuation: function to enforce the • Exclusive compressor control for VRF systems
✓ Time and cost saving installation opening of outdoor units’ and indoor units’ • Continuous adjustment of compressor
expansion valves and solenoid valve’s bypass operation and refrigerant load according to
Reliable logistics ✓ Easier and faster maintenance, indoor demand
• Components delivered to job sites on time troubleshooting and repair ✓ Energy savings
✓ Enhanced installation efficiency
✓ Steady room temperature based on
✓ Proactive labor scheduling Comprehensive training set temperature in each zone
•
Online technical support functions
• All product information available on TS-Web: ✓ Best practice installation
www.jci-hitachi.com/support/technical ✓ Ensures warranty compliance
✓ All resources available 24/7 in one click
36 37
SET FREE Σ – FSXNP & FSXNS SERIES
_ _ _ _
Compressor Outdoor Units Indoor Units Controls
World leading Scroll Compressor technology New patented Σ shaped heat exchanger Wide range of indoor units Fine control of indoor unit operation
• Japanese precision engineering • Improved heat exchange rate • 14 types of indoor units available • 0.5/1˚C increments of set temperature
✓ Superior reliability and quality ✓ • Colored panel option available • Adjustable fan speeds
✓ ✓ Precise control for greater comfort
New compressor shield cover Demand control
• Cover reduces sound while maintaining power • Control and reduce power input within required Motion sensor option available H-LINK communication system
✓ Contributes to quieter outdoor unit operation range and time schedule • Adjusts blown air temperature to the level • Centralized control of multiple indoor
✓ Limits power consumption of occupancy and outdoor units
DC Inverter Scroll Compressor ✓ Slows equipment wear and tear • Stops air conditioning during extended • Versatility to connect various central
• ✓ Reduces noise room vacancy control options
✓ ✓ Adaptive control based on based on room ✓ Indoor comfort tailored to building needs
systems, with superior APF (annual Corrosion resistance activity levels ✓ Enhanced energy savings
performance factor) • Available extra phosphoric acid chromate ✓ Cuts unnecessary operation and saves energy
WELCOME
✓ Improves system management
treatment coating on the heat exchanger
Compressor modulation in 0.1Hz increments ✓ Ideal for locations with harsh outdoor Variety of controllers
• Delivers the exact amount of refrigerant conditions (seaside) • Large range of individual and central
required
✓ Extended equipment longevity and efficiency controllers, from simple to advanced functions
✓ Enables fine control for optimum comfort
• Intuitive and user friendly
✓ Enhanced energy savings Innovative propeller fan ✓ Meets varied user requirements
•
25%, resulting in higher static pressure
BACnet® adapter for BMS integration
✓ Less energy required for equal output • Allows integration of SET FREE Σ into the
✓ Extends motor life building management system, including
Metasys®
Load shedding ✓
• building functions
10–20 minute intervals
✓ Enhanced energy savings
✓ Limits electric load demand
38 39
–
Outdoor units
45 High Efficiency
46 The shape of things to come
47 Our most advanced compressor
48 Smooth Drive: superior compressor control
49 Our biggest fan
50 Design Flexibility
51 Harmony in every climate
51 More flexible piping
52 Combination with indoor units
OUTDOOR UNITS
52 High external static pressure (ESP)
53 Ease of Installation
53 Compactness and lightness
53 Piping direction
54 Comfort
54 The beauty of silence
55 Auto changeover
55 Superior defrosting performance
56 Ease of Maintenance
57 Reliability
57 Rotational operation
57 System failure prevention
57 Solid external parts and anti-corrosion
57 Oil return control
58 New CH-Box
40 41
–
Raising the
standard
OUTDOOR UNITS
compact cabinets and powered
by the world’s most advanced
compressor controller technology,
the next generation SET FREE Σ
outdoor units deliver superior
performance, maximum installation
flexibility and ease of maintenance.
42 43
– –
OUTDOOR UNIT HIGH
OVERVIEW EFFICIENCY
Maximum piping length between outdoor unit and indoor unit m 165 165
OUTDOOR UNITS
Simultaneous Cooling and Heating Operation, Ambient -10 to 24 DB -10 to 24 DB
°C
Temperature Range, with Low Ambient setting (3) -11 to 15 WB -11 to 15 WB
1. Please consult your Hitachi Cooling & Heating channel partner if the height difference is over 50m.
2. For more details, please consult your Hitachi Cooling & Heating channel partner, or refer to the Technical Catalog.
3. Upper figures: mainly cooling / Lower figures: mainly heating. Please consult your Hitachi Cooling & Heating channel partner,
or refer to the Technical Catalog.
5.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 HP class 5.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 HP class
14.0 16.0 22.4 28.0 33.5 40.0 45.0 50.0 kW 16.0 18.0 25.0 31.5 37.5 45.0 50.0 56.0 kW
FSXNS
5.17 5.09
4.54 4.49
4.22 4.13
3.68 3.60 3.65 3.70
3.47 3.55 3.58
3.43
3.24 3.16 3.29
3.11
8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 HP class 8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 HP class
22.4 28.0 33.5 40.0 45.0 50.0 56.0 61.5 67.0 kW 25.0 31.5 37.5 45.0 50.0 56.0 63.0 69.0 77.5 kW
NOTES:
1. The graphs above show the EER/COP of single units for the regions except Oceania or 400V/50Hz regions.
2. The above values indicate the EER/COP per outdoor unit when it is combined with specific indoor units. For more details,
please refer to the Technical Catalog
3. The specification of EER/COP of each country is different according to local regulations. Please consult your Hitachi
Cooling & Heating channel partner for more information.
4. EER (Energy efficiency ratio) = cooling capacity or heating capacity ÷ power consumption of an air conditioner.
5. COP (Coefficient of performance) of an air conditioner = output kW (cooling capacity) ÷ input kW (power consumption). 44 45
SHAPING THE FUTURE OUR MOST ADVANCED COMPRESSOR
exchanger forms the heart of our outdoor units. units are equipped with our most advanced
With a greater exchange surface, the sigma- Scroll DC Inverter compressor.
shaped heat exchange path maximizes heat
exchange performance for energy savings with • Outdoor units perform faster with the improved
scroll compressor’s dramatically extended range
optimized refrigerant performance. You may
of rotation speed
never see the technology, but you will notice the • Capacity control is also managed precisely to ensure
your units operate as efficiently as possible
Control Capacity
11Hz - 110Hz
990 Steps
(by 0.1Hz)
OUTDOOR UNITS
10%
Max. Cooling load Min.
6 Thrust bearing
2 Entry 8
4 10 Motor rotor
46 47
SMOOTH DRIVE: SUPERIOR COMPRESSOR CONTROL OUR BIGGEST FAN
Refrigerant flow
Twin-fan Air outlets +40%
Piping
1 Calculation of proper
refrigerant load
Outdoor Unit
2 All inverter compressor
1,210mm
OUTDOOR UNITS
Transmission Wire
20 20
10 10
ROOM TEMP
ROOM TEMP
–
Room Temperature (°C) Room Temperature (°C) Please refer to the Technical Catalog
Power (kW) Power (kW) for more information about the energy
outdoor units.
48 49
–
DESIGN
FLEXIBILITY
(DB) (DB) (WB) MAINLY HEATING (WB) (DB) (DB) (WB) MAINLY HEATING (WB)
52°C 52°C
48°C 48°C
COMBINATION OF MODULES
FSXNP FSXNS 15°C 15°C 15°C 15°C
* The operation temperature range during simultaneous heating and cooling varies depending on the
ratio between heating and cooling during operation. Please refer to Technical Catalog for more details.
OUTDOOR UNITS
• Piping can be configured to reduce installation costs Maximum Piping Length
• Supports up to 1,000m total piping length and up to EXAMPLE LENGTH (m)
110m height difference
Total piping length - 1,000
Module A Module B Module C Between “1st branch Multi-kit” and the farthest indoor unit L2 90
110 *
( )
Between Outdoor unit is higher than indoor unit H2
outdoor units
L3 and indoor units Indoor unit is higher than outdoor unit 40
CH-Box
Between CH-Box H4 15
L2 Multi Kit
Between indoor units connecting to one CH-Box H5 4
Three Modules 38 to 54 106.0 to 150.0 Three Modules 50 to 54 140.0 to 150.0
H3 Between indoor unit and CH-Box H6 15
CH-Box
–
H5 For full details and conditions of maximum
50 51
–
EASE OF
INSTALLATION
COMBINATION WITH INDOOR UNITS SET FREE Σ outdoor units are designed to work in
OUTDOOR UNITS
Please refer to the Technical Catalog for more
information on Outdoor Unit and Indoor Unit
combination ratio.
• Shorter required piping lengths provide greater design 0Pa 30Pa 60Pa 80Pa
flexibility and may also reduce installation costs
PIPING DIRECTION
1 Wall
2 Outdoor unit
52 53
–
COMFORT
• SET FREE Σ outdoor units feature a new bell mouth casing +∆T
TEMPERATURE
OUTDOOR UNITS
-∆T
Cold
• The lower part of heat exchanger uses sub-cooling
refrigerant that prevents frost and ice formation to
Warm
provide continuous heating
• For the comfort of your building occupants, indoors unit No Frost
fans are stopped during defrosting so that no cold air is
Hot
blown on those inside
• The maximum defrosting interval is now 250 minutes
ROOM TEMPERATURE
86dB(A) Nominal 72.5dB(A) Step 2 86dB(A) Nominal Please refer to the Technical Catalog for more Heating duration More efficient No cold air flow to
more than and comfortable indoors, thanks to
information on defrosting technology. 200% longer automatic indoor
unit stop
54 55
– –
EASE OF RELIABILITY
MAINTENANCE
OUTDOOR UNITS
Rotation
on on off on off on
Oil separator
Accumulator
Compressor
ANTI-CORROSION
Oil return port
• Optional anti-corrosion treatment improves reliability in
Pressure
coastal environments (please refer to page 194 for equalization port
details)
56 57
–
NEW CH-BOX
SYSTEM CONFIGURATION
SINGLE PORT
Liquid Gas
OUTDOOR UNITS
Cooling Heating Cooling Heating
Brazing connection
Flare connection
MULTI PORT
Multi-Port
High/Low Pressure Gas
Liquid Gas
Brazing connection
Flare connection
58 59
“What makes us
unique is that we are
OUTDOOR UNITS
–
Mr. Katsuaki Nagahashi,
Research & Development
60 61
–
Indoor units
& ventilation
70 Ducted
72 High ESP
74 Medium ESP
76 Slim
78 Compact
80 Larger Air Volume
82 Cassette
84 4-Way Cassette
86 4-Way Cassette Compact
92 Concealed
94 Floor Concealed
96 Exposed
98 Floor Exposed
100 Floor/Ceiling Convertible
102 Ceiling Suspended
104 Wall Mounted
106 Ventilation
108 Total Heat Exchanger
62 63
–
Indoor life
64 65
–
LINE-UP OVERVIEW
Indoor Unit Category HP (Class) 0.6 0.8 1.0 1.3 1.5 2.0 2.5 3.0 4.0 5.0 6.0 7.0 8.0 10.0
Cooling (kW) 1.6 2.2 2.8 3.6 4.3 5.6 7.1 8.0 11.2 14.0 16.0 18.0 22.4 28.0
Medium ESP • • • • • • • • •
Slim • • • •
Compact • • • • • •
2-Way Cassette • • • • • • • • •
1-Way Cassette • • • • • •
Floor/Ceiling Convertible • • • • •
Wall Mounted • • • • • • • •
–
FREEDOM OF CHOICE
Motion Sensor
66 67
–
FIND THE PERFECT
INDOOR UNIT
CATEGORY FEATURES DUCTED TYPE CEILING CASSETTE TYPE CONCEALED EXPOSED
High ESP Medium ESP Slim Compact Larger Air Volume 4-Way Cassette 4-Way Cassette 2-Way Cassette 1-Way Cassette Floor Concealed Floor Exposed Floor/Ceiling Ceiling Suspended Wall Mounted
RPI-FSN3/FSN1 RPIM-FSN3 RPIZ-FSNQS RPIZ-FSN1Q RPI-FSN2SQ RCI RCIM RCD RCS RPF (12) RPFI (12) RPFC-FSNQ RPC RPK
Motion Sensor Kit SOR-NEZ SOR-NEZ P-AP160NAE SOR-NEC SOR-NED SOR-NES SOR-NEP
(7) (7)
High humidity kit •
Fresh air intake kit • • • • •
1. Available only in Wired Controller 6. For Clipped ceiling (one-way) type only, with Aperture-shielding set 11. Optional function setting required in use of PC-AWR
2. 5 steps only in use of cooling/dry. 7 steps available in setting individual louver setting 7. Please consult your Hitachi Cooling & Heating channel partner 12. Power-saving function is not applicable
3. 5 steps only in use of cooling/dry. 8. Receiver kit (options) necessary 13. Automatic fan operation available only
4. Sound pressure level in Low-step 9. Ceiling Height, in use of largest HP model in largest air volume
5. 3 colors available (beige, grey and black) 10. With Aperture-shielding set
68 69
DUCTED
–
OVERVIEW
300mm
KEY INFORMATION KEY SPECIFICATIONS
• Engineered to perform quietly and smoothly Nominal cooling capacity (kW) 5.6 ~ 28.0
with the power you need to create your own
Nominal heating capacity (kW) 6.3 ~ 31.5
harmonious atmosphere
Weight (kg) 29 ~ 94 Air Inlet can be chosen from two locations
• ESP values can be changed easily using a wired
remote controller Height (mm) 300 ~ 470
• Air inlets can be located on either rear side or base Depth (mm) 800 ~ 1,060
Rear Air Inlet
ESP standard (Hi1-Hi2) (Pa) 50 (100-200) ~ 50 (100-230)
COMFORT
The optional motion sensor provides a wide detection area, adjusting
1 Motion Sensor
4 Diameter: 8.5m
72 73
– –
MEDIUM EXTERNAL
STATIC PRESSURE
250mm
KEY INFORMATION KEY SPECIFICATIONS
• Air inlets can be located on either rear side or base Depth (mm) 800
Rear Air Inlet
ESP standard (Hi1-Hi2) (Pa) 50 (100-150)
COMFORT
The optional motion sensor provides a wide detection area, adjusting
1 Motion Sensor
4 Diameter: 8.5m
74 75
– –
SLIM
192mm
• Slim units install easily into the narrowest of spaces Nominal cooling capacity (kW) 2.2 ~ 4.3
• Suited for environments that require clean Nominal heating capacity (kW) 2.8 ~ 4.9
1 900m
aesthetics and low noise levels 700mm
Weight (kg) 21
• Suitable for dropped ceilings over hotel room doors
Height (mm) 192
• One of the quietest units in the range: down to
Width (mm) 700
21dB(A)
Depth (mm) 602
COMFORT
Ultra low noise levels, for relaxation or focus
20dB 30dB
CLOCK MIDNIGHT
76 77
– –
COMPACT
192mm 192mm
• Can be installed into a dropped ceiling, such above the Width (mm) 900 ~ 1,170
1 900mm
COMFORT
Ultra low noise levels, for relaxation or focus
Cooling capacity (kW) 2.2 and 2.8 3.6 and 4.3 5.0 and 5.6 6.3 and 7.1
20dB 30dB
CLOCK MIDNIGHT
78 79
– –
LARGER AIR
VOLUME
Multiple zones
Larger Air Volume unit
HOTEL LUXURY DINING RESTAURANT
CONDO ROOM
Piping
Air vent
• Designed to disperse warm and cool air evenly across Nominal cooling capacity (kW) 8.0 ~ 18.0
large spaces or multiple zones
Nominal heating capacity (kW) 9.0 ~ 20.0
• Suitable for larger spaces requiring minimized visual
Weight (kg) 52 ~ 75
impact and low noise levels
Height (mm) 350 ~ 440
• High external static pressure: Up to 120Pa (140Pa in 7HP)
Width (mm) 1,076 ~ 1,430
•
Depth (mm) 550 ~ 800
Long space
80 81
CASSETTE
–
OVERVIEW
82 83
– –
4-WAY CASSETTE
• An excellent solution for large, open plan areas Nominal cooling capacity (kW) 2.8 ~ 16.0
• Industry-leading low noise operation Nominal heating capacity (kW) 3.2 ~ 18.0
• Weight (kg) 20 ~ 26
installation
Height (mm) 248 ~ 298
• Can be installed in a small space inside a false ceiling
Width (mm) 840 1 Height: 3.2m
• Individual four-way louvers accommodate duct 2 0.8m
Depth (mm) 840
• Low noise levels down to 27dB(A) For the full specification table, please refer to page 172.
• Fresh air intake unit available
• Four available color options
COMFORT
Horizontal
1 Horizontal Blow:
1 Blowing Down:
84 85
– –
4-WAY CASSETTE
COMPACT
600mm
COMFORT
Virtually silent in operation, the 4-way Cassette Compact is sized
86 87
– –
2-WAY CASSETTE
• The 2-Way Cassette is the ideal for long, narrow spaces Nominal cooling capacity (kW) 2.2 ~ 16.0
• Installed in the center of the room, it ventilates Nominal heating capacity (kW) 2.5 ~ 18.0
lengthways to provide a consistent temperature
Weight (kg) 23 ~ 39
• Optional motion sensor available for enhanced energy
Height (mm) 298
saving performance
Width (mm) 860 ~ 1,420
• High ceiling installation available with 4.6m air
blowdown (in Hi2 mode, cooling only) Depth (mm) 630
1 Height: 3.1m
2 0.8m
3 Diameter: 8.5m
88 89
– –
1-WAY CASSETTE
• Ideal for smaller or narrow spaces, the 1-Way Cassette Nominal cooling capacity (kW) 2.2 ~ 8.0
can be installed in a corner or on the window side of
Nominal heating capacity (kW) 2.5 ~ 9.0
the room
Weight (kg) 25 ~ 33
•
ceiling, directing air to the center of the room Height (mm) 235
• A new fan inlet design reduces sound pressure for Width (mm) 900 ~ 1,210
Clipped ceiling (two-way)
quieter operation Depth (mm) 720
Provides increased cooling and heating performance with
• Optional motion sensor provides enhanced energy Panel dimensions (mm) 35×1,100×800 ~ 35×1,410×800
Also included:
• Downward air discharge or frontal air discharge (via optional grille)
–
COMFORT
Redesigned fan inlet and fan reduces The optional motion sensor provides a wide detection
sound pressure, down to 27dB(A)
consistently comfortable environment
Non detecting area
1 Height: 2.7m
2 0.8m
7m
Indoor unit cooling capacity (kW) 2.2 2.8 4.0 5.6 7.1 8.0
Indoor
Unit 3 Diameter: 7m
Sound pressure level (dB(A)) 27 28 31 31 32 33
7m
20dB 30dB
CLOCK MIDNIGHT
90 91
CONCEALED
–
OVERVIEW
92 93
– –
FLOOR CONCEALED
• Minimal, low visibility design makes Floor Nominal cooling capacity (kW) 2.8 ~ 7.1
Cavity that
conceals
Concealed units an excellent option when there the unit
Nominal heating capacity (kW) 3.2 ~ 8.5
is no ceiling void
Weight (kg) 19 ~ 28
•
620mm
Height (mm) 620
• Very little installation space is required
Width (mm) 848 ~ 1,223
• Suitable for installation below a window
Depth (mm) 220 1,045mm
Air Inlet
94 95
EXPOSED
–
OVERVIEW
• A modern take on a classic design, Floor Nominal cooling capacity (kW) 2.8 ~ 7.1
Exposed units are ideal for installation
Nominal heating capacity (kW) 3.2 ~ 8.5
under windows and in hallways
Weight (kg) 25 ~ 34
• Little installation space required thanks to
only 220mm depth and 630mm of height Height (mm) 630
98 99
– –
FLOOR/CEILING
CONVERTIBLE
KEY INFORMATION KEY SPECIFICATIONS Floor Mounted Installation Option Ceiling Mounted Installation Option
• When performance and practicality are a priority, Nominal cooling capacity (kW) 8.0 ~ 14.2
Convertible units are a functional solution
Nominal heating capacity (kW) 9.0 ~ 16.3
680mm
• Suitable for creating a calming and comfortable
Weight (kg) 31 ~ 47
atmosphere in small to medium-sized spaces
Air Outlet
230mm
Height (mm) 230
•
Width (mm) 990 ~ 1,580
• Installation is simple and straightforward
680mm
Air Outlet
Depth (mm) 680
• The design incorporates a fresh air intake for
ate (m3/min) Air Inlet
optimal air quality and freshness 13-11-9 ~ 33-28-23
Air Inlet
Sound pressure level – 39-35-30 ~ 51-46-40
ceiling (dB(A))
Also included:
230mm
• Optional drain pump available Sound pressure level – 43-38-35 ~ 55-50-46
• [Floor use] 680mm height is suited to installation
100 101
– –
CEILING SUSPENDED
• Designed for spaces with higher ceilings as well Nominal cooling capacity (kW) 4.0 ~ 16.0
as commercial kitchen or classroom applications
Nominal heating capacity (kW) 4.8 ~ 18.0
where warmed or cooled air needs to be
supplied to a wide area Weight (kg) 26 ~ 41
• Optional motion sensor available for enhanced Sound pressure level (dB(A)) 37-35-31-28 ~ 49-47-42-36 Indoor unit capacity HP (Class) 1.5~3.0 4.0~6.0
COMFORT
The optional motion sensor has a 7m2 range, allowing the system
to deliver optimal air across the entire space with enhanced
3 Diameter: 7m
4 Width of Room: 7m
102 103
– –
WALL MOUNTED
1,800mm
min of
Also included: Sound pressure level (dB) 35-32-31-29 ~ 51-49-46-41
• Expansion valve options, both built in and external
• Optional strainer kit
• Optional drain pump with 1,000mm lift
–
104 105
VENTILATION
–
OVERVIEW
106 107
–
TOTAL HEAT
EXCHANGER
RECOMMENDED FACILITIES
• Designed to improve air quality and energy ESP (Hi/Me/Lo) (Pa) 65/40/20 ~ 230/120/80
there is limited indoor/outdoor air exchange Sound pressure level (dB(A)) 33.5-32-26 ~ 47-45-41.5
Also included:
• The system can be configured for a wide range of capacity,
depending on the size and layout of the interior spaces
–
108 109
“Because our
inverter calculates
110 111
–
Control systems
CONTROL SYSTEMS
142 PC-ARF1
146 PC-ARH1
147 PC-AWR
148 PC-AR
112 113
–
Management
made simple
CONTROL SYSTEMS
make managing even the most
complex systems, second nature.
114 115
CENTRALIZED
CONTROLLERS
–
CONTROL SYSTEMS
all the building management and
monitoring functions you need in
one centralized location.
116 117
CENTRALIZED CONTROLLER
–
H-LINK
BASIC WIRING
CONTROL SYSTEMS
1 Point
PSC-A32MN
NO CONNECTION BOUNDARIES
PSC-A32MN
1 Point 1 Point
PSC-6RAD
118 119
–
SYSTEM HIERARCHY
Outdoor Unit
Indoor Unit
PSC-A32MN
CONTROL SYSTEMS
3. Group 3. Group
4. Block
PSC-A32MN
1 Point
120 121
–
COMPARING
CENTRAL STATIONS
Layout •
List (Type number) 3
CONTROL SYSTEMS
By Block
By Group • •
By RCS group • •
By indoor unit • •
Control Function Main 5 functions (5) • • • •
Individual Controller Lock • △ (3) • •
Filter sign reset • • • •
Outdoor unit capacity control △ (4) •
Outdoor unit noise control •
Monitor Function Main 5 functions (5) • • • •
Individual Controller Lock • • • •
Alarm status & code • • • •
Filter Sign • • • •
Air inlet Temperature of indoor unit • • • •
Air inlet Temperature of outdoor unit • • • •
Schedule Function Weekly • • • •
Setting times per day 10 10 16 16
Annual/Summer/Winter Schedule • •
Other function Alarm history (records number) 100 100 500 10,000
1. One external adapter can control [128 remote controller groups/128 groups/32 blocks] and Central Station EX can connect up to 15 adapters
2. No restriction on the number of H-LINK systems
3. Individual function control in each remote controller is not applicable
4. Applied via schedule function or external signal input
5. Main 5 functions: 1) Run/Stop 2) Operation mode 3) Temperature setting 4) Fan speed 5) Louver control
122 123
CENTRAL STATION –
–
MINI
PSC-A32MN
RECOMMENDED FACILITIES
CONTROL SYSTEMS
Group 32
Outdoor Unit 64
Notes:
1. Installers: please note minimum depth required for wall cavity space
Settings include: ON/OFF, Operation Mode, Fan Speed, Louver Swing Direction,
Temperature, and restriction of individual controller operation for individual settings
Energy Saving
Set room temperature ranges and control outdoor unit
power consumption using the Schedule function.
Capacity control of outdoor units Temperature limits for each individual controller
124 125
CENTRAL STATION –
–
EZ
PSC-A64GT
RECOMMENDED FACILITIES Touch Panel Operation
CONTROL SYSTEMS
Group 64
Block 4
Outdoor Unit 64
Notes:
1. Installers: please note minimum depth required for wall cavity space
Schedule
Program up to 10 actions a day for each RCS group.
126 127
CENTRAL STATION –
–
NT
PSC-A128WEB3
RECOMMENDED FACILITIES Two intuitive viewing options
Operation On On On On On On Alarm
Mode Color Setting (Cool) (Heat) (Dry) (Fan) (Auto) (In multiple mode)
SCHOOL / MEDIUM / LARGE GENERAL
UNIVERSITY BUILDING HOSPITAL Light Blue
Detail Mode Light Blue Orange Sea Green Light Grey Purple Red Grey
Orange
Panel
Icon-based monitoring panel.
If your VRF system serves a large facility or Outer Dimensions (H*W*D) (mm) 68.0×240.0×154.0
multiple buildings, Central Station NT gives you
Net Weight (kg) 1.4
the freedom to control it from multiple points or
even remote locations. Using the web-enabled Display Locally-Supplied PC or Touch-Panel PC
centralized controller, you can monitor up to 128 Display Control Locally-Supplied or Touch-Panel
Group 128
CONTROL SYSTEMS
Block 64
Outdoor Unit 64
Filter Function
Select only the key information you need to receive Check the meaning of each icon
for easier monitoring. quickly, using the icon guide.
128 129
–
Flexible Schedules
CONTROL SYSTEMS
Summer / Winter seasonal setting Special Day setting
Alarm Codes
130 131
CENTRAL STATION –
–
EX
PSC-A128EX
RECOMMENDED FACILITIES Easy to read, easy to use New Schedule Setting
Central Station EX is designed to control cooling Outer Dimensions (H*W*D) (mm) 227.2×372.0×60.3
and heating operations in medium to large scale Net Weight (kg) 3.5
buildings such as hotels, educational facilities Built-in part (mm)(3) 27.8
or hospitals. You can control up to 2,560 indoor Display 12.1 inch TFT color liquid crystal display
units by connecting up to 15 Extension Adapters Display Control Touch Panel
(PSC-AD128EX). Total Connection Capacity RCS Group 2,560 (1)
CONTROL SYSTEMS
Block 512 (2)
• Management reports can be viewed in several formats
Indoor Unit 2,560 (1)
• Up to two years of historical data can be recalled for:
Outdoor Unit 1,024 (1) ؞ Accumulated operation time (min.)
؞ Accumulated thermo-ON time (min.)
1. One extension adapter can control [160 RCS groups/128 groups/160 indoor ؞ Average air intake temperature of indoor unit
units/64 outdoor units/Each layout], and Central Station EX can connect up
؞ Average air intake temperature of outdoor unit
to 15 adapters
2. No restriction on the number of H-LINK connections ؞ Average set temperature
3. Installers: please note minimum depth required for wall cavity space ؞ Average individual controller sensor temperature
Available ports
• Acquire data using SD memory and USB flash devices
؞Distribution, settings and log history can be saved to
CSV files
SD
USB
132 133
–
Layout Style
CONTROL SYSTEMS
Floor View System Diagram Actual Room Image
Customize the display by moving indoor Images can be uploaded in multiple
units on the touch panel formats (BMP, JPEG, PNG)
List Style
Temperature mode
134 135
CENTRAL STATION CENTRALIZED ON/OFF CONTROLLER
– –
PSC-A64S PSC-A16RS
If your site has a dedicated building manager, the When there is no on-site building manager, an ON/
Central Station PSC-A64S is suitable for providing OFF controller can operate heating and cooling
convenient monitoring of indoor climates. It functions according to a schedule. PSC-A16RS
controls up to 160 indoor units and up to 8 KEY SPECIFICATIONS can connect up to 16 remote control groups, 160 KEY SPECIFICATIONS
sub-controllers can be connected via H-LINK. indoor units and up to 8 controllers via H-LINK.
Outer Dimensions (H*W*D) (mm) 120.0×120.0×70.5 Outer Dimensions (H*W*D) (mm) 120.0×120.0×68.5
An external input terminal is also provided and PSC-A16RS is designed to be used with a remote
the unit can be used in combination with the Net Weight (g) 300 control switch* and can be used in combination Net Weight (g) 300
CONTROL SYSTEMS
* There are restrictions on remote group registration. Please consult your Hitachi
Should a problem occur, a dedicated alarm Cooling & Heating channel partner for more information.
code helps you identify the issue.
136 137
INDIVIDUAL
CONTROLLERS
–
Compact Intelligence
CONTROL SYSTEMS
138 139
–
COMPARING INDIVIDUAL
CONTROLLERS
Setting Run/Stop • • • •
Operation Mode • • • •
Auto mode setting • • • •
Temperature setting rate 0.5ºC/1ºC/1ºF 1ºC 1ºC/1ºF 0.5ºC/1ºC/1ºF
Fan Speed 3 (Hi/Me/Lo) taps 3 (Hi/Me/Lo) taps 3 (Hi/Me/Lo) taps 3 (Hi/Me/Lo) taps
4 (Hi2/Hi/Me/Lo) taps 4 (Hi2/Hi/Me/Lo) taps 4 (Hi2/Hi/Me/Lo) taps
Louver Direction • • • •
Individual Louver Setting •
Service Filter Sign • •
Filter Sign Reset • • •
Room Name Setting •
Alarm sign • • •
Alarm history display •
Schedule & Management • • •
Weekly schedule • •
CONTROL SYSTEMS
Outdoor unit noise reduction •
schedule
140 141
ADVANCED WIRED REMOTE CONTROLLER –
–
PC-ARF1
Menu Button
Access all settings in an
easy to navigate layout.
[Up] [Down]:
select one from 4 change the settings
main items in each item
LARGE SCALE VERSATILITY KEY SPECIFICATIONS
This advanced wired controller gives you a suite Outer Dimensions (H*W*D) (mm) 120.0×120.0×17.9
of intelligent controls to manage multiple indoor
Net Weight (g) 200
units. Powerful features include built-in timers,
scheduling and temperature range settings and ADVANCED FUNCTIONS
motion sensing. Master Control Temperature
One PC-ARF1 can function as a centralized Setting Increments
controller for multiple indoor units, each Setting available in
of which has their own PC-ARF1 individual 0.5/1.0ºC or 1.0ºF.
CONTROL SYSTEMS
control unit.
Help Menu
*Thermometer can be chosen from one of Instant access to Screen
four sensors (Air inlet, Air outlet, Individual Guide, Operation Manuals
controller (PC-ARF1) and Remote Sensor and Troubleshooting.
(THM-R2A))
142 143
–
Without Peak-cut control Cooling Operation Cooling Operation MED 17min 17min
TIME
POWER CONSUMPTION
POWER CONSUMPTION
TIME 30min
Maximum Capacity Operation Fan Operation * The indoor fan operation is Fan Operation
in Power Saving Set Value Range Indoor Unit number performed in rotation by indoor Cooling Operation
Moderate Control Setting
unit address number
CONTROL SYSTEMS
power consumption of your units by day,
week and year.
(Cooling Mode)
19°C 30°C
Lower to 19˚C Back to 28˚C
Automatically
Lower Limit 25°C
19˚C
OPERATION SCHEDULING
TIME
Weekly Schedule Built-in Timer
Can not go lower Available set range
Temperature set point
temperature returns to the set point. The time can needed, such as at night. Timer increments are
be selected from four options (15-30-60-90 min). shown below:
1 2 24
Standard operation Moderate operation Minimal operation when Standby mode if the room is
for a room with high for rooms with fewer the room is empty for a set
activity levels occupants period of time Hours
144 145
SIMPLIFIED WIRED REMOTE CONTROLLER WIRELESS REMOTE CONTROLLER
– –
PC-ARH1 PC-AWR
FOR SHARED SPACES KEY SPECIFICATIONS LIVING HARMONY ON THE MOVE KEY SPECIFICATIONS
When many people will use a single controller, Outer Dimensions (H*W*D) (mm) 120.0×70.0×17.0 Go wireless with intuitive control. One PC-AWR Outer Dimensions (H*W*D) (mm) 140.0×55.0×16.8
such as in a hotel room, PC-ARH1 provides remote control unit can control several indoor
Net Weight (g) 90 Net Weight (g) 75
quick and easy access to basic air conditioning units simultaneously when connected by a
functions. It’s also backlit, making it easy to use Receiver Kit.
at all hours.
CONTROL SYSTEMS
146 147
WIRED REMOTE CONTROLLER
–
PC-AR
RECOMMENDED FACILITIES
An economic, robust wired controller, perfect Outer Dimensions (H*W*D) (mm) 120.0×70.0×17.0
CONTROL SYSTEMS
148 149
“I’m always looking
for things that
CONTROL SYSTEMS
–
Mr Kazuhiro Tani,
Global Product Development
150 151
–
tables
SPECIFICATION TABLES
172 Cassette
172 4-Way Cassette
173 4-Way Cassette Compact
174 2-Way Cassette
175 1-Way Cassette
176 Concealed
176 Floor Concealed
177 Exposed
177 Floor Exposed
178 Floor/Ceiling Convertible
179 Ceiling Suspended
180 Wall Mounted
181 Ventilation
181 Total Heat Exchanger
152 153
–
For your
reference
SPECIFICATION TABLES
154 155
SPECIFICATION TABLES – OUTDOOR UNITS
–
FSXNP SERIES
Outdoor Unit Model RAS-5FSXNP RAS-6FSXNP RAS-8FSXNP RAS-10FSXNP RAS-12FSXNP RAS-14FSXNP Outdoor Unit Model RAS-16FSXNP RAS-18FSXNP RAS-20FSXNP RAS-22FSXNP RAS-24FSXNP
Power Supply Current AC 3 Phase Combination of Base Unit Module – – RAS-10FSXNP RAS-10FSXNP RAS-12FSXNP
– – RAS-10FSXNP RAS-12FSXNP RAS-12FSXNP
V/Hz 400/50
380-415/50 Power Supply Current AC 3 Phase
380/60
220/60 V/Hz 400/50
380-415/50
Nominal Cooling Capacity kW 14.0 16.0 22.4 28.0 33.5 40.0 380/60
220/60
Nominal Heating Capacity kW 16.0 18.0 25.0 31.5 37.5 45.0
Nominal Cooling Capacity kW 45.0 50.0 56.0 61.5 67.0
Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)
Nominal Heating Capacity kW 50.0 56.0 63.0 69.0 77.5
Outer Dimensions H*W*D mm 1,675×950×765 1,675×950×765 1,675×1,210×765 1,675×1,210×765 1,675×1,210×765 1,675×1,210×765
Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)
Sound Level Sound Power Level dB(A) 75 78 77 82 83 85
Outer Dimensions H*W*D mm 1,675×1,600×765 1,675×1,600×765 1,675×2,440×765 1,675×2,440×765 1,675×2,440×765
Sound Pressure Level dB(A) 54 56 55 59 60 62
Sound Level Sound Power Level dB(A) 85 86 85 86 86
Weight Net Weight 380-415V/50Hz, kg 195 195 258 262 263 273
380V/60Hz Sound Pressure Level dB(A) 65 65 62 62.5 63
220V/60Hz kg 190 190 253 257 258 268 Weight Net Weight 380-415V/50Hz, kg 350 365 262+262 262+263 263+263
380V/60Hz
Gross Weight 380-415V/50Hz, kg 211 211 276 280 281 291
380V/60Hz 220V/60Hz kg 345 360 257+257 257+258 258+258
SPECIFICATION TABLES
220V/60Hz kg 206 206 271 275 276 286 Gross Weight 380-415V/50Hz, kg 370 385 280+280 280+281 281+281
380V/60Hz
Refrigerant Type R410A
220V/60Hz kg 365 380 275+275 275+276 276+276
Flow Control Micro-Computer Control Expansion Valve
Refrigerant Type R410A
Charge (before Shipment) kg 4.7 5.0 8.5 8.5 9.3 9.3
Flow Control Micro-Computer Control Expansion Valve
Compressor Type Hermetic (Scroll)
Charge (before Shipment) kg 10.0 10.6 17.0 17.8 18.6
Model AA50PHD AA50PHD AA50PHD DB65PHD DC80PHD DC80PHD
Compressor Type Hermetic (Scroll)
Quantity 1 1 1 1 1 1
Model AA50PHD DC80PHD DB65PHD DB65PHD DC80PHD
Motor Output Pole kW 1.9 (6) 2.1 (6) 3.1 (6) 3.8 (6) 5.1 (6) 6.4 (6) + AA50PHD + DC80PHD + DB65PHD + DC80PHD + DC80PHD
Charge L/Unit 6.0 6.0 6.0 6.0 6.0 6.9 Motor Output Pole kW 3.7 (6)×2 4.4 (6)×2 3.8 (6)×2 3.8 (6)×1 5.1 (6)×2
+ 5.1 (6)×1
Heat Exchanger Multi-Pass Cross-Finned Tube
Oil Type FVC68D
Condenser Fan Type Propeller Fan
Charge L/Unit 7.9 7.9 12.0 12.0 12.0
Quantity 1 1 2 2 2 2
Heat Exchanger Multi-Pass Cross-Finned Tube
Air Flow Rate m3/min. 150 170 185 219 219 243
Condenser Fan Type Propeller Fan
Motor Output Pole kW 0.20 (8) 0.28 (8) 0.18 (8)×2 0.26 (8)×2 0.26 (8)×2 0.34 (8)×2
Quantity 2 2 4 4 4
Main Refrigerant Liquid Line mm Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ12.7 Φ12.7
Piping Air Flow Rate m3/min. 326 362 219×2 219×2 219×2
Gas Line Low Pressure mm Φ15.88 Φ19.05 Φ19.05 Φ22.2 Φ25.4 Φ25.4
Heat Recovery Motor Output Pole kW 0.47 (8)×2 0.62 (8)×2 0.26 (8)×2 0.26 (8)×2 0.26 (8)×2
System (3 Pipes) High/Low Pressure mm Φ12.7 Φ15.88 Φ15.88 Φ19.05 Φ22.2 Φ22.2 + 0.26 (8)×2 + 0.26 (8)×2 + 0.26 (8)×2
Packaging Dimensions H*W*D mm 1,800×1,030×810 1,800×1,030×810 1,800×1,290×810 1,800×1,290×810 1,800×1,290×810 1,800×1,290×810 Main Refrigerant Liquid Line mm Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Piping
Volume m3 1.5 1.5 1.9 1.9 1.9 1.9 Gas Line Low Pressure mm Φ28.58 Φ28.58 Φ28.58 Φ28.58 Φ28.58
Heat Recovery
System (3 Pipes) High/Low Pressure mm Φ22.2 Φ22.2 Φ22.2 Φ25.4 Φ25.4
156 157
SET FREE Σ – FSXNP & FSNXS SERIES
HP Class 26 28 30 32 34 36 HP Class 38 40 42 44 46
Outdoor Unit Model RAS-26FSXNP RAS-28FSXNP RAS-30FSXNP RAS-32FSXNP RAS-34FSXNP RAS-36FSXNP Outdoor Unit Model RAS-38FSXNP RAS-40FSXNP RAS-42FSXNP RAS-44FSXNP RAS-46FSXNP
Combination of Base Unit Module RAS-10FSXNP RAS-12FSXNP RAS-12FSXNP RAS-14FSXNP RAS-16FSXNP RAS-18FSXNP Combination of Base Unit Module RAS-12FSXNP RAS-12FSXNP RAS-14FSXNP RAS-12FSXNP RAS-14FSXNP
RAS-16FSXNP RAS-16FSXNP RAS-18FSXNP RAS-18FSXNP RAS-18FSXNP RAS-18FSXNP RAS-12FSXNP RAS-14FSXNP RAS-14FSXNP RAS-14FSXNP RAS-14FSXNP
RAS-14FSXNP RAS-14FSXNP RAS-14FSXNP RAS-18FSXNP RAS-18FSXNP
Power Supply Current AC 3 Phase
Power Supply Current AC 3 Phase
V/Hz 400/50
380-415/50 V/Hz 400/50
380/60 380-415/50
220/60 380/60
220/60
Nominal Cooling Capacity kW 73.0 77.5 85.0 90.0 95.0 100.0
Nominal Cooling Capacity kW 106.0 112.0 118.0 122.0 128.0
Nominal Heating Capacity kW 82.5 90.0 95.0 100.0 106.0 112.0
Nominal Heating Capacity kW 118.0 125.0 132.0 140.0 145.0
Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)
Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)
Outer Dimensions H*W*D mm 1,675×2,830×765 1,675×2,830×765 1,675×2,830×765 1,675×2,830×765 1,675×3,220×765 1,675×3,220×765
Outer Dimensions H*W*D mm 1,675×3,670×765 1,675×3,670×765 1,675×3,670×765 1,675×4,060×765 1,675×4,060×765
Sound Level Sound Power Level dB(A) 87 87 88 89 89 89
Sound Level Sound Power Level dB(A) 89 89 90 90 90
Sound Pressure Level dB(A) 66 66 66 67 68 68
Sound Pressure Level dB(A) 65.5 66 67 67.5 68
Weight Net Weight 380-415V/50Hz, kg 262+350 263+350 263+365 273+365 350+365 365+365
380V/60Hz Weight Net Weight 380-415V/50Hz, kg 263+263+273 263+273+273 273+273+273 263+273+365 273+273+365
380V/60Hz
220V/60Hz kg 257+345 258+345 258+360 268+360 345+360 360+360
220V/60Hz kg 258+258+268 258+268+268 268+268+268 258+268+360 268+268+360
SPECIFICATION TABLES
Gross Weight 380-415V/50Hz, kg 280+370 281+370 281+385 291+385 370+385 385+385
380V/60Hz Gross Weight 380-415V/50Hz, kg 281+281+291 281+291+291 291+291+291 281+291+385 291+291+385
380V/60Hz
220V/60Hz kg 275+365 276+365 276+380 286+380 365+380 380+380
220V/60Hz kg 276+276+286 276+286+286 286+286+286 276+286+380 286+286+380
Refrigerant Type R410A
Refrigerant Type R410A
Flow Control Micro-Computer Control Expansion Valve
Flow Control Micro-Computer Control Expansion Valve
Charge (before Shipment) kg 18.5 19.3 19.9 19.9 20.6 21.2
Charge (before Shipment) kg 27.9 27.9 27.9 29.2 30.5
Compressor Type Hermetic (Scroll)
Compressor Type Hermetic (Scroll)
Model DB65PHD DC80PHD DC80PHD DC80PHD AA50PHD DC80PHD
+ AA50PHD + AA50PHD + DC80PHD + DC80PHD + AA50PHD + DC80PHD Model DC80PHD DC80PHD DC80PHD DC80PHD DC80PHD
+ AA50PHD + AA50PHD + DC80PHD + DC80PHD + DC80PHD + DC80PHD + DC80PHD + DC80PHD + DC80PHD + DC80PHD + DC80PHD
+ DC80PHD + DC80PHD + DC80PHD + DC80PHD + DC80PHD + DC80PHD + DC80PHD
+ DC80PHD + DC80PHD
Quantity 3 3 3 3 4 4
Quantity 3 3 3 4 4
Motor Output Pole kW 3.8 (6)×1 5.1 (6)×1 5.1 (6)×1 6.4 (6)×1 3.7 (6)×2 4.4 (6)×2
+ 3.7 (6)×2 + 3.7 (6)×2 + 4.4 (6)×2 + 4.4 (6)×2 + 4.4 (6)×2 + 4.4 (6)×2 Motor Output Pole kW 5.1 (6)×2 5.1 (6)×1 6.4 (6)×3 5.1 (6)×1 6.4 (6)×1
+ 6.4 (6)×1 + 6.4 (6)×2 + 6.4 (6)×1 + 6.4 (6)×1
Oil Type FVC68D + 4.4 (6)×2 + 4.4 (6)×2
Charge L/Unit 13.9 13.9 13.9 14.8 15.8 15.8 Oil Type FVC68D
Heat Exchanger Multi-Pass Cross-Finned Tube Charge L/Unit 18.9 19.8 20.7 20.8 21.7
Condenser Fan Type Propeller Fan Heat Exchanger Multi-Pass Cross-Finned Tube
Air Flow Rate m3/min. 219+326 219+326 219+362 243+362 326+362 362×2 Quantity 6 6 6 6 6
Motor Output Pole kW 0.26 (8)×2 0.26 (8)×2 0.26 (8)×2 0.34 (8)×2 0.47 (2)×2 0.62 (8)×2 Air Flow Rate m3/min. 219×2+243 219+243×2 243×3 219+243+362 243×2+362
+ 0.47 (8)×2 + 0.47 (8)×2 + 0.62 (8)×2 + 0.62 (2)×2 + 0.62 (2)×2 + 0.62 (8)×2
Motor Output Pole kW 0.26 (8)×2 0.26 (8)×2 0.34 (8)×2 0.26 (8)×2 0.34 (8)×2
Main Refrigerant Liquid Line mm Φ19.05 Φ19.05 Φ19.05 Φ19.05 Φ19.05 Φ19.05 + 0.26 (8)×2 + 0.34 (8)×2 + 0.34 (8)×2 + 0.34 (8)×2 + 0.34 (8)×2
Piping + 0.34 (8)×2 + 0.34 (8)×2 + 0.34 (8)×2 + 0.62 (8)×2 + 0.62 (8)×2
Gas Line Low Pressure mm Φ31.75 Φ31.75 Φ31.75 Φ31.75 Φ31.75 Φ38.1
Heat Recovery Main Refrigerant Liquid Line mm Φ19.05 Φ19.05 Φ19.05 Φ19.05 Φ19.05
System (3 Pipes) High/Low Pressure mm Φ25.4 Φ28.58 Φ28.58 Φ28.58 Φ28.58 Φ28.58 Piping
Gas Line Low Pressure mm Φ38.1 Φ38.1 Φ38.1 Φ38.1 Φ38.1
Heat Recovery
System (3 Pipes) High/Low Pressure mm Φ31.75 Φ31.75 Φ31.75 Φ31.75 Φ31.75
158 159
SPECIFICATION TABLES – OUTDOOR UNITS
–
FSXNS SERIES
Outdoor Unit Model RAS-48FSXNP RAS-50FSXNP RAS-52FSXNP RAS-54FSXNP Outdoor Unit Model RAS-8FSXNS RAS-10FSXNS RAS-12FSXNS RAS-14FSXNS RAS-16FSXNS RAS-18FSXNS
Combination of Base Unit Module RAS-12FSXNP RAS-14FSXNP RAS-16FSXNP RAS-18FSXNP Power Supply Current AC 3 Phase
RAS-18FSXNP RAS-18FSXNP RAS-18FSXNP RAS-18FSXNP
RAS-18FSXNP RAS-18FSXNP RAS-18FSXNP RAS-18FSXNP V/Hz 400/50
380-415/50
Power Supply Current AC 3 Phase 380/60
220/60
V/Hz 400/50
380-415/50 Nominal Cooling Capacity kW 22.4 28.0 33.5 40.0 45.0 50.0
380/60
220/60 Nominal Heating Capacity kW 25.0 31.5 37.5 45.0 50.0 56.0
Nominal Cooling Capacity kW 136.0 140.0 145.0 150.0 Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)
Nominal Heating Capacity kW 150.0 155.0 160.0 165.0 Outer Dimensions H*W*D mm 1,675×950×765 1,675×950×765 1,675×950×765 1,675×1,210×765 1,675×1,210×765 1,675×1,210×765
Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5) Sound Level Sound Power Level dB(A) 80 82 82 85 85 86
Outer Dimensions H*W*D mm 1,675×4,450×765 1,675×4,450×765 1,675×4,840×765 1,675×4,840×765 Sound Pressure Level dB(A) 58 60 59 63 63 65
Sound Level Sound Power Level dB(A) 90 90 90 91 Weight Net Weight 380-415V/50Hz, kg 195 195 215 271 314 315
380V/60Hz
Sound Pressure Level dB(A) 68.5 69 70 70
220V/60Hz kg 190 190 210 266 309 310
Weight Net Weight 380-415V/50Hz, kg 263+365+365 273+365+365 350+365+365 365+365+365
380V/60Hz Gross Weight 380-415V/50Hz, kg 211 211 231 289 332 333
380V/60Hz
220V/60Hz kg 258+360+360 268+360+360 345+360+360 360+360+360
SPECIFICATION TABLES
220V/60Hz kg 206 206 226 284 327 328
Gross Weight 380-415V/50Hz, kg 281+385+385 291+385+385 370+385+385 385+385+385
380V/60Hz Refrigerant Type R410A
220V/60Hz kg 276+380+380 286+380+380 365+380+380 380+380+380 Flow Control Micro-Computer Control Expansion Valve
Refrigerant Type R410A Charge (before Shipment) kg 5.0 5.0 7.2 8.9 9.9 10.7
Flow Control Micro-Computer Control Expansion Valve Compressor Type Hermetic (Scroll)
Charge (before Shipment) kg 30.5 30.5 31.2 31.8 Model AA50PHD AA50PHD DC80PHD DC80PHD AA50PHD AA50PHD
+ AA50PHD + AA50PHD
Compressor Type Hermetic (Scroll)
Quantity 1 1 1 1 2 2
Model DC80PHD+DC80PHD DC80PHD+DC80PHD AA50PHD+AA50PHD DC80PHD+DC80PHD
+DC80PHD+DC80PHD + DC80PHD+DC80PHD + DC80PHD+DC80PHD + DC80PHD+DC80PHD Motor Output Pole kW 3.3 (6) 4.3 (6) 5.4 (6) 8.0 (6) 4.5 (6)×2 5.0 (6)×2
+DC80PHD + DC80PHD + DC80PHD+DC80PHD + DC80PHD+DC80PHD
Oil Type FVC68D
Quantity 5 5 6 6
Charge L/Unit 6.0 6.0 6.0 6.9 7.9 7.9
Motor Output Pole kW 5.1 (6)×1 6.4 (6)×1 3.7 (6)×2 4.4 (6)×2
+4.4 (6)×2 +4.4 (6)×2 + 4.4 (6)×2 + 4.4 (6)×2 Heat Exchanger Multi-Pass Cross-Finned Tube
+4.4 (6)×2 +4.4 (6)×2 + 4.4 (6)×2 + 4.4 (6)×2
Condenser Fan Type Propeller Fan
Oil Type FVC68D
Quantity 1 1 1 2 2 2
Charge L/Unit 21.8 22.7 23.7 23.7
Air Flow Rate m3/min. 165 170 190 239 256 256
Heat Exchanger Multi-Pass Cross-Finned Tube
Motor Output Pole kW 0.26 (8) 0.28 (8) 0.42 (8) 0.33 (8)×2 0.39 (8)×2 0.39 (8)×2
Condenser Fan Type Propeller Fan
Main Refrigerant Liquid Line mm Φ9.52 Φ9.52 Φ12.7 Φ12.7 Φ12.7 Φ15.88
Quantity 6 6 6 6 Piping
Gas Line Low Pressure mm Φ19.05 Φ22.2 Φ25.4 Φ25.4 Φ28.58 Φ28.58
Air Flow Rate m3/min. 219+362×2 243+362×2 326+362×2 362×3 Heat Recovery
System (3 Pipes) High/Low Pressure mm Φ15.88 Φ19.05 Φ22.2 Φ22.2 Φ22.2 Φ22.2
Motor Output Pole kW 0.26 (8)×2 0.34 (8)×2 0.47 (8)×2 0.62 (8)×2
+0.62 (8)×2 +0.62 (8)×2 + 0.62 (8)×2 + 0.62 (8)×2 Packaging Dimensions H*W*D mm 1,800×1,030×810 1,800×1,030×810 1,800×1,030×810 1,800×1,290×810 1,800×1,290×810 1,800×1,290×810
+0.62 (8)×2 +0.62 (8)×2 + 0.62 (8)×2 + 0.62 (8)×2
Volume m3 1.5 1.5 1.5 1.9 1.9 1.9
Main Refrigerant Liquid Line mm Φ19.05 Φ19.05 Φ19.05 Φ19.05
Piping
Gas Line Low Pressure mm Φ38.1 Φ38.1 Φ38.1 Φ38.1
Heat Recovery
System (3 Pipes) High/Low Pressure mm Φ31.75 Φ31.75 Φ31.75 Φ31.75
160 161
SET FREE Σ – FSXNP & FSNXS SERIES
HP Class 20 22 24 26 28 30 HP Class 32 34 36 38 40 42
Outdoor Unit Model RAS-20FSXNS RAS-22FSXNS RAS-24FSXNS RAS-26FSXNS RAS-28FSXNS RAS-30FSXNS Outdoor Unit Model RAS-32FSXNS RAS-34FSXNS RAS-36FSXNS RAS-38FSXNS RAS-40FSXNS RAS-42FSXNS
Combination of Base Unit Module – – – RAS-12FSXNS RAS-12FSXNS RAS-12FSXNS Combination of Base Unit Module RAS-14FSXNS RAS-16FSXNS RAS-18FSXNS RAS-14FSXNS RAS-18FSXNS RAS-18FSXNS
RAS-14FSXNS RAS-16FSXNS RAS-18FSXNS RAS-18FSXNS RAS-18FSXNS RAS-18FSXNS RAS-24FSXNS RAS-22FSXNS RAS-24FSXNS
Nominal Cooling Capacity kW 56.0 61.5 67.0 73.0 77.5 85.0 Nominal Cooling Capacity kW 90.0 95.0 100.0 106.0 112.0 118.0
Nominal Heating Capacity kW 63.0 69.0 77.5 82.5 90.0 95.0 Nominal Heating Capacity kW 100.0 106.0 112.0 118.0 125.0 132.0
Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5) Cabinet Color Munsell Code Natural Gray (1.0Y 8.5/0.5)
Outer Dimensions H*W*D mm 1,675×1,600×765 1,675×1,600×765 1,675×1,600×765 1,675×2,180×765 1,675×2,180×765 1,675×2,180×765 Outer Dimensions H*W*D mm 1,675×2,440×765 1,675×2,440×765 1,675×2,440×765 1,675×2,830×765 1,675×2,830×765 1,675×2,830×765
Sound Level Sound Power Level dB(A) 86 84 86 87 87 87 Sound Level Sound Power Level dB(A) 89 89 89 89 88 89
Sound Pressure Level dB(A) 65 64 66 64.5 64.5 66 Sound Pressure Level dB(A) 67 67 68 68 67.5 68.5
Weight Net Weight 380-415V/50Hz, kg 355 369 370 215+271 215+314 215+315 Weight Net Weight 380-415V/50Hz, kg 271+315 314+315 315+315 271+370 315+369 315+370
380V/60Hz 380V/60Hz
220V/60Hz kg 350 364 365 210+266 210+309 210+310 220V/60Hz kg 266+310 309+310 310+310 266+365 310+364 310+365
SPECIFICATION TABLES
Gross Weight 380-415V/50Hz, kg 375 389 390 231+289 231+332 231+333 Gross Weight 380-415V/50Hz, kg 289+333 332+333 333+333 289+390 333+389 333+390
380V/60Hz 380V/60Hz
220V/60Hz kg 370 384 385 226+284 226+327 226+328 220V/60Hz kg 284+328 327+328 328+328 284+385 328+384 328+385
Flow Control Micro-Computer Control Expansion Valve Flow Control Micro-Computer Control Expansion Valve
Charge (before Shipment) kg 11.3 11.3 11.6 16.1 17.1 17.9 Charge (before Shipment) kg 19.6 20.6 21.4 20.5 22.0 22.3
Model AA50PHD DC80PHD DC80PHD DC80PHD DC80PHD DC80PHD Model DC80PHD AA50PHD AA50PHD DC80PHD AA50PHD AA50PHD
+ AA50PHD + DC80PHD + DC80PHD + DC80PHD + AA50PHD + AA50PHD + AA50PHD + AA50PHD + AA50PHD + DC80PHD + AA50PHD + AA50PHD
+ AA50PHD + AA50PHD + AA50PHD + AA50PHD + AA50PHD + DC80PHD + DC80PHD + DC80PHD
+ AA50PHD + AA50PHD + DC80PHD + DC80PHD
Quantity 2 2 2 2 3 3
Quantity 3 4 4 3 4 4
Motor Output Pole kW 5.5 (6)×2 6.7 (6)×2 7.1 (6)×2 5.4 (6)×1 5.4 (6)×1 5.4 (6)×1
+ 8.0 (6)×1 + 4.5 (6)×2 + 5.0 (6)×2 Motor Output Pole kW 8.0 (6)×1 4.5 (6)×2 5.0 (6)×2 8.0 (6)×1 5.0 (6)×2 5.0 (6)×2
+5.0 (6)×2 +5.0 (6)×2 +5.0 (6)×2 +7.1 (6)×2 +6.7 (6)×2 +7.1 (6)×2
Oil Type FVC68D
Oil Type FVC68D
Charge L/Unit 8.4 8.4 8.4 12.9 13.9 13.9
Charge L/Unit 14.8 15.8 15.8 15.3 16.3 16.3
Heat Exchanger Multi-Pass Cross-Finned Tube
Heat Exchanger Multi-Pass Cross-Finned Tube
Condenser Fan Type Propeller Fan
Condenser Fan Type Propeller Fan
Quantity 2 2 2 3 3 3
Quantity 4 4 4 4 4 4
Air Flow Rate m3/min. 329 329 348 190+239 190+256 190+256
Air Flow Rate m3/min. 239+256 256×2 256×2 239+348 256+329 256+348
Motor Output Pole kW 0.48 (8)×2 0.48 (8)×2 0.56 (8)×2 0.42 (8) 0.42 (8) 0.42 (8)
+ 0.33 (8)×2 + 0.39 (8)×2 + 0.39 (8)×2 Motor Output Pole kW 0.33 (8)×2 0.39 (8)×2 0.39 (8)×2 0.33 (8)×2 0.39 (8)×2 0.39 (8)×2
+0.39 (8)×2 +0.39 (8)×2 +0.39 (8)×2 +0.56 (8)×2 +0.48 (8)×2 +0.56 (8)×2
Main Refrigerant Liquid Line mm Φ15.88 Φ15.88 Φ15.88 Φ19.05 Φ19.05 Φ19.05
Piping Main Refrigerant Liquid Line mm Φ19.05 Φ19.05 Φ19.05 Φ19.05 Φ19.05 Φ19.05
Gas Line Low Pressure mm Φ28.58 Φ28.58 Φ28.58 Φ31.75 Φ31.75 Φ31.75 Piping
Heat Recovery Gas Line Low Pressure mm Φ31.75 Φ31.75 Φ38.1 Φ38.1 Φ38.1 Φ38.1
System (3 Pipes) High/Low Pressure mm Φ22.2 Φ25.4 Φ25.4 Φ25.4 Φ28.58 Φ28.58 Heat Recovery
System (3 Pipes) High/Low Pressure mm Φ28.58 Φ28.58 Φ28.58 Φ31.75 Φ31.75 Φ31.75
Packaging Dimensions H*W*D mm 1,800×1,680×810 1,800×1,680×810 1,800×1,680×810 – – –
162 163
SPECIFICATION TABLE NOTES – OUTDOOR UNITS
–
FSXNP & FSXNS SERIES
HP Class 44 46 48 50 52 54
Weight Net Weight 380-415V/50Hz, kg 369+369 369+370 370+370 271+315+315 314+315+315 315+315+315
380V/60Hz
SPECIFICATION TABLES
Gross Weight 380-415V/50Hz, kg 389+389 389+390 390+390 289+333+333 332+333+333 333+333+333
380V/60Hz
Quantity 4 4 4 5 6 6
Motor Output Pole kW 6.7(6)×2 6.7(6)×2 7.1(6)×2 8.0(6)×1 4.5(6)×2 5.0 (6)×2
+6.7(6)×2 +7.1(6)×2 +7.1(6)×2 +5.0(6)×2 +5.0(6)×2 +5.0(6)×2
+5.0(6)×2 +5.0(6)×2 +5.0(6)×2
Quantity 4 4 4 6 6 6
Air Flow Rate m3/min. 329×2 329+348 348×2 239+256×2 256×3 256×3
–
Main Refrigerant Liquid Line mm Φ19.05 Φ19.05 Φ19.05 Φ19.05 Φ19.05 Φ19.05
Piping
Gas Line Low Pressure mm Φ38.1 Φ38.1 Φ38.1 Φ38.1 Φ38.1 Φ38.1
Heat Recovery
System (3 Pipes) High/Low Pressure mm Φ31.75 Φ31.75 Φ31.75 Φ31.75 Φ31.75 Φ31.75 the Technical Catalog.
164 165
SPECIFICATION TABLES – CH-BOX SPECIFICATION TABLES – INDOOR UNITS
– –
SINGLE PORT & HIGH EXTERNAL
MULTI PORT STATIC PRESSURE
Model Name CH-AP160SSX CH-AP280SSX CH-AP04MSSX CH-AP08MSSX CH-AP12MSSX CH-AP16MSSX Power Supply Current AC 1 Phase
Nominal Cooling Capacity kW 5.6 7.1 8.0 11.2 14.0 16.0 22.4 28.0
Nominal Heating Capacity kW 6.3 8.5 9.0 12.5 16.0 18.0 25.0 31.5
Dimensions H*W*D mm 191×301×214 191×301×214 260×303×352 260×543×352 260×783×352 260×1,023×352
Sound Pressure Level (Hi2/Hi/Me/Lo) dB(A) 41/38/35/32 37/35/32/30 39/36/33/31 40/37/34/32 42/39/36/33 44/40/37/34 45/43/40/36 50/48/46/39
Net Weight (kg) 6 6 14 25 36 47
Outer Height mm 300 300 300 300 300 300 470 470
Electrical Details Power Supply Current AC 1 Phase Dimensions
Width mm 700 1,050 1,050 1,400 1,400 1,400 1,380 1,380
V/Hz 230/50
220-240/50 Depth mm 800 800 800 800 800 800 1,060 1,060
220/60
Net Weight kg 29 38 38 48 48 48 94 94
Power Input W 5 5 11.2 22.4 33.6 44.8
Refrigerant R410A
Current A 0.1 0.1 0.2 0.4 0.6 0.8
Indoor Fan Air Flow Rate m3/min 14.5/13/11/9.5 18.5/16.5/14.5/12 20/17.5/15.5/13 30/26.5/23/20 33.5/29.5/26/22 36/31.5/27.5/24 63/58/50/38 80/72/64/48
Maximum Total Capacity Index kW 16 28 44.8 85 85 85 (Hi2/Hi/Me/Lo)
Number of Ports (for indoor unit) 1 1 4 8 12 16 External Static Pressure (3) Pa 50 (100/200) 50 (100/200) 50 (100/200) 50 (100/200) 50 (100/200) 50 (100/200) 50 (100/230) 50 (100/230)
SPECIFICATION TABLES
Maximum Connectable indoor units per Port 7 8 6 6 6 6 Motor W 157 190 190 259 259 259 840 840
Maximum Piping Between CH-Box and m 40 Connections Flare-Nut Connection (with Flare Nuts) Brazing Connection
length the indoor unit
Refrigerant Liquid Line mm Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52
Maximum Height Between CH-Boxes m 15
Piping
Gas Line mm Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ19.05 Φ22.2
Between CH-Box and m 15
indoor unit
Condensate Drain VP25
Between indoor units m 4
Packaging Volume m3 0.28 0.39 0.39 0.50 0.50 0.50 0.97 0.97
connecting to same
CH-Box
Notes:
1. The cooling and heating capacities above show 2. The sound pressure level is based on the following
the maximum capacities when outdoor and indoor conditions:
temperatures are under the following conditions: ؟1.5m beneath the unit
؟With Discharge Duct (2.0m) and Return Duct (1.0m)
Cooling Operation Conditions ؟Voltage of the power source for the indoor fan
Indoor Air Inlet Temperature: 27ᵒC DB motor is 220V
19ᵒC WB ؟The above data was measured in an anechoic
Outdoor Air Inlet Temperature: 35ᵒC DB
Piping Length: 7.5m prior to installation
0m
3. Regarding external static pressure: the data shown
Heating Operation Conditions indicates “Standard Pressure Setting (High Pressure Setting
Indoor Air Inlet Temperature: 20ᵒC DB
Outdoor Air Inlet Temperature: 7ᵒC DB used. The sound pressure level is based on the Standard
6ᵒC WB Pressure Setting.
Piping Length: 7.5m
0m
– –
the Technical Catalog. the Technical Catalog.
166 167
SPECIFICATION TABLES – INDOOR UNITS SPECIFICATION TABLES – INDOOR UNITS
– –
MEDIUM EXTERNAL SLIM
STATIC PRESSURE
Nominal Cooling Capacity kW 2.2 2.8 4.0 5.6 7.1 8.0 11.2 14.0 16.0 Nominal Cooling Capacity kW 2.2 2.8 3.6 4.3
Nominal Heating Capacity kW 2.5 3.2 4.8 6.3 8.5 9.0 12.5 16.0 18.0 Nominal Heating Capacity kW 2.8 3.3 4.2 4.9
Sound Pressure Level (Hi2/Hi/Me/Lo) dB(A) 32/30/28/27 33/31/29/28 38/35/32/30 40/37/34/31 37/35/33/31 38/36/33/31 40/38/35/32 42/39/36/34 43/40/37/34 Sound Pressure Level (Hi/Me/Lo) dB(A) 28/25/22 28/25/22 32/30/28 32/30/28
Outer Height mm 250 250 250 250 250 250 250 250 250 Outer Height mm 192 192 192 192
Dimensions Dimensions
Width mm 700 700 700 700 1,000 1,000 1,400 1,400 1,400 Width mm 700 700 700 700
Depth mm 800 800 800 800 800 800 800 800 800 Depth mm 602 602 602 602
Indoor Fan Air Flow Rate m3/min 8.5/7.5/6.5/5.5 9.5/8.5/7.5/6.5 13/11.5/10/8.5 14.5/13/11/9.5 18.5/16.5/14/12 20/17.5/15.5/13 30/26.5/23/20 33.5/29.5/26/22 36/31.5/27.5/24 Indoor Fan Air Flow Rate m3/min 8/7/6 8/7/6 10/8/7 10/8/7
(Hi2/Hi/Me/Lo) (Hi/Me/Lo)
External Static Pressure (3) Pa 50 (100/150) 50 (100/150) 50 (100/150) 50 (100/150) 50 (100/150) 50 (100/150) 50 (100/150) 50 (100/150) 50 (100/150) External Static Pressure (3) Pa 10 (30) 10 (30) 10 (30) 10 (30)
SPECIFICATION TABLES
Motor W 157 157 157 157 190 190 259 259 259 Motor W 15 15 25 25
Connections Flare-Nut Connection (with Flare Nuts) Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35
Piping Piping
Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Gas Line mm Φ12.70 Φ12.70 Φ12.70 Φ12.70
Packaging Volume m3 0.24 0.24 0.24 0.24 0.33 0.33 0.42 0.42 0.42 Packaging Volume m3 0.15 0.15 0.15 0.15
Notes:
Notes:
1. The cooling and heating capacities above show 2. The sound pressure level is based on the following
1. The cooling and heating capacities above show 2. The sound pressure level is based on the following the maximum capacities when outdoor and indoor conditions:
the maximum capacities when outdoor and indoor conditions: temperatures are under the following conditions: ؟1.5m beneath the unit
temperatures are under the following conditions: ؟1.5m beneath the unit ؟With Discharge Duct (2.0m) and Return Duct (1.0m)
؟With Discharge Duct (2.0m) and Return Duct (1.0m) Cooling Operation Conditions ؟Voltage of the power source for the indoor fan
Cooling Operation Conditions ؟Voltage of the power source for the indoor fan Indoor Air Inlet Temperature: 27ᵒC DB motor is 220V
Indoor Air Inlet Temperature: 27ᵒC DB motor is 220V 19ᵒC WB ؟In case of the power source of 240V, the sound pressure
19ᵒC WB ؟The above data was measured in an anechoic Outdoor Air Inlet Temperature: 35ᵒC DB level increases by about 1dB(A)
Outdoor Air Inlet Temperature: 35ᵒC DB Piping Length: 7.5m ؟The above data was measured in an anechoic
Piping Length: 7.5m prior to installation 0m
0m prior to installation
3. Regarding external static pressure: the data shown Heating Operation Conditions ؟
Heating Operation Conditions indicates “Standard Pressure Setting (High Pressure Setting Indoor Air Inlet Temperature: 20ᵒC DB 3. The data for external pressure indicates “Standard pressure
Indoor Air Inlet Temperature: 20ᵒC DB Outdoor Air Inlet Temperature: 7ᵒC DB
Outdoor Air Inlet Temperature: 7ᵒC DB used. The sound pressure level is based on the Standard 6ᵒC WB used.
6ᵒC WB Pressure Setting. Piping Length: 7.5m
Piping Length: 7.5m 0m
0m
– –
the Technical Catalog. the Technical Catalog.
168 169
SPECIFICATION TABLES – INDOOR UNITS SPECIFICATION TABLES – INDOOR UNITS
– –
COMPACT LARGER AIR
VOLUME
Nominal Cooling Capacity kW 2.2 2.8 3.6 4.3 5.0 5.6 6.3 7.1 Nominal Cooling Capacity kW 8.0 11.2 14.0 16.0 18.0
Nominal Heating Capacity kW 2.8 3.3 4.2 4.9 5.6 6.5 7.5 8.5 Nominal Heating Capacity kW 9.0 12.5 16.0 18.0 20.0
Sound Pressure Level (Hi/Me/Lo) dB(A) 27/24/21 27/24/21 31/29/26 31/29/26 34/30/28 34/30/28 35/33/30 35/33/30 Sound Pressure Level (Hi/Me/Lo) dB(A) 46/44/40 48/45/41 49/46/43 53/49/45 51/47/42
Outer Height mm 192 192 192 192 192 192 192 192 Outer Height mm 350 350 350 350 440
Dimensions Dimensions
Width mm 900 900 900 900 1,170 1,170 1,170 1,170 Width mm 1,076 1,076 1,300 1,300 1,430
Depth mm 447 447 447 447 447 447 447 447 Depth mm 800 800 800 800 550
Indoor Fan Air Flow Rate m3/min 8/7/6 8/7/6 10/8/7 10/8/7 14.5/12.5/10.5 14.5/12.5/10.5 16/14/12 16/14/12 Indoor Fan High Pressure m3/min 29/26/20 36/33/25 47/43/34 56/50/40 65/57/46
(Hi/Me/Lo) Air Flow Rate Setting
(Hi/Me/Lo)
External Static Pressure (3) Pa 10 (30) 10 (30) 10 (30) 10 (30) 10 (30) 10 (30) 10 (30) 10 (30) Standard Pressure m3/min 29/26/20 36/29/25 47/39/36 56/48/42 –
SPECIFICATION TABLES
Setting
Motor W 16 16 25 25 40 40 50 50
External Static Pressure (3) Pa 120 (70) 120 (70) 120 (70) 120 (70) 140
Connections Flare-Nut Connection (with Flare Nuts)
Motor W 250 300 420 550 650
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52
Connections Flare-Nut Connection (with Flare Nuts)
Piping
Gas Line mm Φ12.70 Φ12.70 Φ12.70 Φ12.70 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Refrigerant Liquid Line mm Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52
Condensate Drain VP25 Piping
Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Packaging Volume m3 0.15 0.15 0.15 0.15 0.18 0.18 0.18 0.18
Condensate Drain VP25
1. The cooling and heating capacities above show 2. The sound pressure level is based on the following
Notes:
the maximum capacities when outdoor and indoor conditions:
temperatures are under the following conditions: ؟1.5m beneath the unit
1. The cooling and heating capacities above show 2. The sound pressure level is based on the following
؟With Discharge Duct (2.0m) and Return Duct (1.0m)
the maximum capacities when outdoor and indoor conditions:
Cooling Operation Conditions ؟Voltage of the power source for the indoor fan
temperatures are under the following conditions: ؟1.5m beneath the unit
Indoor Air Inlet Temperature: 27ᵒC DB motor is 220V
؟With Discharge Duct (2.0m) and Return Duct (1.0m)
19ᵒC WB ؟In case of the power source of 240V, the sound pressure
Cooling Operation Conditions ؟Voltage of the power source for the indoor fan
Outdoor Air Inlet Temperature: 35ᵒC DB level increases by about 1dB(A)
Indoor Air Inlet Temperature: 27ᵒC DB motor is 220V
Piping Length: 7.5m ؟The above data was measured in an anechoic
19ᵒC WB ؟In case of the power source of 240V, the sound pressure
0m
Outdoor Air Inlet Temperature: 35ᵒC DB level increases by about 1dB(A)
prior to installation
Piping Length: 7.5m ؟The above data was measured in an anechoic
Heating Operation Conditions
0m
Indoor Air Inlet Temperature: 20ᵒC DB 3. The data for external pressure indicates “Standard pressure
prior to installation
Outdoor Air Inlet Temperature: 7ᵒC DB
Heating Operation Conditions
6ᵒC WB used.
Indoor Air Inlet Temperature: 20ᵒC DB 3. The data for external pressure indicates “High pressure
Piping Length: 7.5m
Outdoor Air Inlet Temperature: 7ᵒC DB
0m
6ᵒC WB is not used. The sound pressure level is based on the
Piping Length: 7.5m Standard Pressure Setting.
0m
– –
the Technical Catalog. the Technical Catalog.
170 171
SPECIFICATION TABLES – INDOOR UNITS SPECIFICATION TABLES – INDOOR UNITS
– –
4-WAY CASSETTE 4-WAY CASSETTE
COMPACT
Nominal Cooling Capacity kW 2.8 4.0 5.6 7.1 8.0 11.2 14.0 16.0 Nominal Cooling Capacity kW 1.6 2.2 2.8 4.0 5.6 7.1
Nominal Heating Capacity kW 3.2 4.8 6.3 8.5 9.0 12.5 16.0 18.0 Nominal Heating Capacity kW 1.9 2.5 3.2 4.8 6.3 8.5
Sound Pressure Level (Hi2/Hi/Me/Lo) dB(A) 33/30/28/27 35/31/30/27 37/32/30/27 42/36/32/28 42/36/32/28 48/43/39/33 48/45/40/35 48/46/41/37 Sound Pressure Level (Hi2/Hi/Me/Lo) dB(A) 34/30/28/24.5 36/33/29/24.5 38/34/30/24.5 41/37/33/27.5 45/39/35/31 47/43/39/35
Outer Height mm 248 248 248 248 298 298 298 298 Outer Height mm 280 280 280 280 280 280
Dimensions Dimensions
Width mm 840 840 840 840 840 840 840 840 Width mm 570 570 570 570 570 570
Depth mm 840 840 840 840 840 840 840 840 Depth mm 570 570 570 570 570 570
Indoor Fan Air Flow Rate m3/min 15/13/11/9 21/17/14/11 22/17/14/11 27/23/18/14 27/23/18/14 37/31/24/20 37/33/26/21 37/35/28/22 Indoor Fan Air Flow Rate m3/min 10/8.5/7.5/6 11/9.5/8/6 12/10/8.5/6 13/11/9.5/7 15/12/10/8 16/14/12/10
(Hi2/Hi/Me/Lo) (Hi2/Hi/Me/Lo)
SPECIFICATION TABLES
Connections Flare-Nut Connection (with Flare Nuts) Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52
Piping Piping
Gas Line mm Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88
Packaging Volume m3 0.21 0.21 0.21 0.21 0.25 0.25 0.25 0.25
P-AP56NAM
Adaptable Panel Model (without Motion Sensor)
P-AP160NA1 P-AP160NAE
Adaptable Panel Model (without Motion Sensor) (with Motion Sensor) Color Neutral White
– prior to installation –
the Technical Catalog. the Technical Catalog.
172 173
SPECIFICATION TABLES – INDOOR UNITS SPECIFICATION TABLES – INDOOR UNITS
– –
2-WAY CASSETTE 1-WAY CASSETTE
Nominal Cooling Capacity kW 2.2 2.8 4.0 5.6 7.1 8.0 11.2 14.0 16.0 Nominal Cooling Capacity kW 2.2 2.8 4.0 5.6 7.1 8.0
Nominal Heating Capacity kW 2.5 3.2 4.8 6.3 8.5 9.0 12.5 16.0 18.0 Nominal Heating Capacity kW 2.5 3.2 4.8 6.3 8.5 9.0
Sound Pressure Level (Hi2/Hi/Me/Lo) dB(A) 30/29/28/27 31/29/28/27 37/34/31/30 39/36/33/30 42/39/36/33 45/42/38/33 43/40/37/34 47/44/41/35 48/45/42/39 Sound Pressure Level (Hi2/Hi/Me/Lo) dB(A) 34/32/29/27 36/34/31/28 40/37/33/31 42/38/35/31 43/39/36/32 43/40/37/33
Outer Height mm 298 298 298 298 298 298 298 298 298 Outer Height mm 235 235 235 235 235 235
Dimensions Dimensions
Width mm 860 860 860 860 860 860 1,420 1,420 1,420 Width mm 900 900 900 900 1,210 1,210
Depth mm 630 630 630 630 630 630 630 630 630 Depth mm 720 720 720 720 720 720
Indoor Fan Air Flow Rate m3/min 10/9/ 11/9.5/ 15/13/ 16.5/14.5/ 18.5/16.5/ 21/18.5/ 30/26.5/ 35/31/ 37/32.5/ Indoor Fan Air Flow Rate m3/min 8.5/7.5/6.5/6 9.5/8.5/7.5/6.5 13/11.5/10/8.5 14.5/13/11/9.5 18.5/16.5/14.5/12.5 20/17.5/15.5/13
(Hi2/Hi/Me/Lo) 7.5/6.5 8.5/7 11.5/10 12.5/10.5 14.5/12.5 16/12.5 23/20 27/21 28.5/24 (Hi2/Hi/Me/Lo)
SPECIFICATION TABLES
Connections Flare-Nut Connection (with Flare Nuts) Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52
Piping Piping
Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88
Packaging Volume m3 0.24 0.24 0.24 0.24 0.24 0.24 0.36 0.36 0.36 Packaging Volume m3 0.25 0.25 0.25 0.25 0.32 0.32
P-AP90DNA P-AP160DNA
Adaptable Panel Model (for RCD- [0.8-3.0] FSN3) (for RCD- [4.0-6.0] FSN3) Adaptable Panel Model P-AP36CNA (for RCS-[0.8-1.0]FSN) P-AP56CNA (for RCS-[1.5-2.0]FSN) P-AP80CNA (for RCS-[2.5-3.0]FSN)
Notes: 1. The cooling and heating capacities above show Heating Operation Conditions
the maximum capacities when outdoor and indoor Indoor Air Inlet Temperature: 20ᵒC DB
1. The cooling and heating capacities above show Heating Operation Conditions temperatures are under the following conditions: Outdoor Air Inlet Temperature: 7ᵒC DB
the maximum capacities when outdoor and indoor Indoor Air Inlet Temperature: 20ᵒC DB 6ᵒC WB
temperatures are under the following conditions: Outdoor Air Inlet Temperature: 7ᵒC DB Cooling Operation Conditions Piping Length: 7.5m
6ᵒC WB Indoor Air Inlet Temperature: 27ᵒC DB 0m
Cooling Operation Conditions Piping Length: 7.5m 19ᵒC WB
Indoor Air Inlet Temperature: 27ᵒC DB 0m Outdoor Air Inlet Temperature: 35ᵒC DB 2. The sound pressure level is based on the following
19ᵒC WB Piping Length: 7.5m conditions:
Outdoor Air Inlet Temperature: 35ᵒC DB 2. The sound pressure level is based on the following 0m ؟1.5m beneath the unit
Piping Length: 7.5m conditions: ؟The above data was measured in an anechoic
0m ؟1.5m beneath the unit
؟The above data was measured in an anechoic prior to installation
– prior to installation –
the Technical Catalog. the Technical Catalog.
174 175
SPECIFICATION TABLES – INDOOR UNITS SPECIFICATION TABLES – INDOOR UNITS
– –
FLOOR FLOOR EXPOSED
CONCEALED
Nominal Cooling Capacity kW 2.8 4.0 5.6 7.1 Nominal Cooling Capacity kW 2.8 4.0 5.6 7.1
Nominal Heating Capacity kW 3.2 4.8 6.3 8.5 Nominal Heating Capacity kW 3.2 4.8 6.3 8.5
Sound Pressure Level (Hi/Me/Lo) dB(A) 35/32/29 38/35/31 39/36/32 42/38/34 Sound Pressure Level (Hi/Me/Lo) dB(A) 35/32/29 38/35/31 39/36/32 42/38/34
Indoor Fan Air Flow Rate m3/min 8.5/7/6 12/10/09 16/14/11 16/14/11 Refrigerant R410A
(Hi/Me/Lo)
Indoor Fan Air Flow Rate m3/min 8.5/7/6 12/10/09 16/14/11 16/14/11
Motor W 20 28 45 45 (Hi/Me/Lo)
SPECIFICATION TABLES
Connections Flare-Nut Connection (with Flare Nuts) Motor W 20 28 45 45
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ9.52 Connections Flare-Nut Connection (with Flare Nuts)
Piping
Gas Line mm Φ12.70 Φ12.70 Φ15.88 Φ15.88 Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ9.52
Piping
Condensate Drain VP25 Gas Line mm Φ12.70 Φ12.70 Φ15.88 Φ15.88
1. The cooling and heating capacities above show 2. The sound pressure level is based on the following Notes:
the maximum capacities when outdoor and indoor conditions:
temperatures are under the following conditions: ؟1.0m from the unit 1. The cooling and heating capacities above show 2. The sound pressure level is based on the following
؟ the maximum capacities when outdoor and indoor conditions:
Cooling Operation Conditions ؟Voltage of the power source for the indoor fan temperatures are under the following conditions: ؟1.0m from the unit
Indoor Air Inlet Temperature: 27ᵒC DB motor is 220V ؟
19ᵒC WB ؟The above data was measured in an anechoic Cooling Operation Conditions ؟Voltage of the power source for the indoor fan
Outdoor Air Inlet Temperature: 35ᵒC DB Indoor Air Inlet Temperature: 27ᵒC DB motor is 220V
Piping Length: 7.5m prior to installation 19ᵒC WB ؟The above data was measured in an anechoic
0m Outdoor Air Inlet Temperature: 35ᵒC DB
Piping Length: 7.5m prior to installation
Heating Operation Conditions 0m
Indoor Air Inlet Temperature: 20ᵒC DB
Outdoor Air Inlet Temperature: 7ᵒC DB Heating Operation Conditions
6ᵒC WB Indoor Air Inlet Temperature: 20ᵒC DB
Piping Length: 7.5m Outdoor Air Inlet Temperature: 7ᵒC DB
0m 6ᵒC WB
Piping Length: 7.5m
0m
– –
the Technical Catalog. the Technical Catalog.
176 177
SPECIFICATION TABLES – INDOOR UNITS SPECIFICATION TABLES – INDOOR UNITS
– –
FLOOR / CEILING CEILING
CONVERTIBLE SUSPENDED
Nominal Cooling Capacity kW 8.0 11.2 8.0 11.2 8.4 9.0 11.2 14.2 Nominal Cooling Capacity kW 4.0 5.6 7.1 8.0 11.2 14.0 16.0
Nominal Heating Capacity kW 9.0 12.5 9.0 12.5 9.6 10.0 13.0 16.3 Nominal Heating Capacity kW 4.8 6.3 8.5 9.0 12.5 16.0 18.0
Sound Pressure Ceiling Mode dB(A) 39/35/30 39/35/30 45/41/37 45/41/37 43/39/34 45/40/36 51/46/40 50/46/42 Sound Pressure Level (Hi2/Hi/Me/Lo) dB(A) 37/35/31/28 38/35/31/28 38/35/31/28 40/37/33/29 44/42/37/32 48/45/41/35 49/47/42/36
Level
Color Neutral White
Sound Pressure Floor Mode dB(A) 43/38/35 43/38/35 48/44/40 48/44/40 46/41/37 48/43/39 54/49/43 55/50/46
Level Outer Height mm 235 235 235 235 235 235 235
Dimensions
Outer Height mm 230 230 230 230 230 230 230 230 Width mm 960 960 1,270 1,270 1,580 1,580 1,580
Dimensions
Width mm 990 990 990 990 1,285 1,285 1,285 1,580 Depth mm 690 690 690 690 690 690 690
Depth mm 680 680 680 680 680 680 680 680 Net Weight kg 26 27 35 35 41 41 41
Refrigerant R410A Indoor Fan Air Flow Rate m3/min 15/13/11/9 15/13/11/9 19/16.5/14/11.5 21/18.5/15.5/12.5 30/26.5/22/17 35/31/25.5/20 37/32.5/27/21
(Hi2/Hi/Me/Lo)
SPECIFICATION TABLES
Indoor Fan Air Flow Rate m3/hr 780/660/540 780/660/540 966/840/678 966/840/678 1,092/912/732 1,164/978/798 1,488/1,230/978 1,980/1,680/1,380
(Hi/Me/Lo) Motor W 50 50 80 80 160 160 160
Connections Flare-Nut Connection (with Flare Nuts) Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52
Piping
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Gas Line mm Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Piping
Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Condensate Drain VP20
Condensate Drain VP25 Packaging Volume m3 0.23 0.23 0.31 0.31 0.38 0.38 0.38
Packaging Volume m3 0.31 0.31 0.31 0.31 0.40 0.40 0.40 0.48
Notes:
Notes: 1. The cooling and heating capacities above show 2. The sound pressure level is based on the following
the maximum capacities when outdoor and indoor conditions:
1. The cooling and heating capacities above show 2. The sound pressure level is based on the following temperatures are under the following conditions: ؟1.0m beneath the unit
the maximum capacities when outdoor and indoor conditions: ؟1.0m from discharge grille
temperatures are under the following conditions: ؟1.0m beneath the unit Cooling Operation Conditions ؟The above data was measured in an anechoic
؟1.0m from discharge grille Indoor Air Inlet Temperature: 27ᵒC DB
Cooling Operation Conditions ؟The above data was measured in an anechoic 19ᵒC WB prior to installation
Indoor Air Inlet Temperature: 27ᵒC DB Outdoor Air Inlet Temperature: 35ᵒC DB
19ᵒC WB prior to installation Piping Length: 7.5m
Outdoor Air Inlet Temperature: 35ᵒC DB ؟ When bottom air inlet is adopted, sound pressure will 0m
Piping Length: 7.5m increase according to factors such as installation mode
0m and the room structure Heating Operation Conditions
Indoor Air Inlet Temperature: 20ᵒC DB
Heating Operation Conditions Outdoor Air Inlet Temperature: 7ᵒC DB
Indoor Air Inlet Temperature: 20ᵒC DB 6ᵒC WB
Outdoor Air Inlet Temperature: 7ᵒC DB Piping Length: 7.5m
6ᵒC WB 0m
Piping Length: 7.5m
0m
– –
the Technical Catalog. the Technical Catalog.
178 179
SPECIFICATION TABLES – INDOOR UNITS SPECIFICATION TABLES – VENTILATION
– –
WALL TOTAL HEAT
MOUNTED EXCHANGER
Power Supply Current AC 1 Phase AC 1 Phase Power Supply Current AC 1 Phase AC 1 Phase
Sound Pressure Level dB 35/32/ 39/35/ 39/35/ 46/40/ 42/40/ 49/43/ 49/43/ 51/49/ 35/32/ 39/35/ 39/35/ 46/40/ For Cooling % 62.5/62.5/68 61.5/61.5/68 64.5/64.5/68 64.5/64.5/67 62.5/62.5/70 61.5/61.5/70 64.5/64.5/68.5 64.5/64.5/71
(Hi2/Hi/Me/Lo) 31/29 32/30 32/30 36/33 38/33 40/36 40/36 46/41 31/29 32/30 32/30 36/33 (Hi/Me/Lo)
Color White White Sound Pressure At 1.5m from the dB 26.5-27.5/ 32.5-33.5/ 33.5-34.5/ 36-37/34-35/ 28.5/25.5/21 32.5/28.5/23 35/31/29 36/34/30
Level unit (under) 25-26/21-22 30-31/23.5-24.5 32-33/30-31 31.5-32.5
Outer Height mm 300 300 300 300 300 300 300 300 300 300 300 300 (Hi/Me/Lo) (2)(4)
Dimensions
Width mm 790 790 790 900 1,150 1,150 1,150 1,150 790 790 790 900 At Air Outlet dB 33.5-34.5/ 40.5-41.5/ 44.5-45.5/ 47-48/45-46/ 35.5/32.5/26 40.5/36.5/29 46/42/39 47/45/40
(Hi/Me/Lo) (3)(4) 32-33/26-27 38-39/29.5-30.5 43-44/40-41 41.5-42.5
Depth mm 230 230 230 230 245 245 245 245 230 230 230 230
Outer Height mm 275 317 398 398 275 317 398 398
Net Weight kg 10 10 10 11 17 18 18 18 10 10 10 11 Dimensions
Width mm 735 1,016 1,004 1,231 735 1,016 1,004 1,231
Refrigerant R410A R410A
Depth mm 780 888 1,164 1,164 780 888 1,164 1,164
Air Flow Rate (Hi2/Hi/Me/Lo) m3/min 8/7.5/ 10/8/ 10/8/ 14/11/ 15/14/ 19/17/ 19/17/ 22/19/ 8/7.5/ 10/8/ 10/8/ 14/11/
SPECIFICATION TABLES
7/6 7/6.5 7/6.5 9/7.5 13/10 14/12 14/12 17/15 7/6 7/6.5 7/6.5 9/7.5 Net Weight kg 21 33 61 72 21 33 61 72
Motor Output W 40 40 40 40 40 40 40 40 40 40 40 40 Air Flow Rate (Hi/Me/Lo) m3/hr 250/250/165 500/500/350 800/800/670 1,000/1,000/870 250/250/150 500/500/300 800/800/660 1,000/1,000/720
Connections Flare-Nut Connection (with Flare Nuts) Flare-Nut Connection (with Flare Nuts) External Static Pressure (Hi/Me/Lo) Pa 65/40/20 150/60/30 140/100/70 160/100/80 100/50/20 200/60/20 230/120/80 200/110/60
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Connection Duct Diameter mm Φ150 Φ200 Φ250 Φ250 Φ150 Φ200 Φ250 Φ250
Piping
Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ12.7 Φ12.7 Φ12.7 Φ12.7
Notes:
Condensate Drain VP16 VP16
Packaging Volume m3 0.09 0.09 0.09 0.11 0.14 0.14 0.14 0.14 0.09 0.09 0.09 0.11 1. 3. Air outlet noise is measured at a 45ᵒ angle, 1.5m in front
power supply, 220-240V/50Hz and 220V/60Hz of the unit
Accessory Included Wall Mounting Bracket Wall Mounting Bracket
2. The sound pressure level is based on the following 4. The sound pressure level is based on the total heat
conditions: exchange mode. In case of the bypass ventilation mode,
Notes: ؟1.0m beneath the unit the sound pressure level increase by approximately 1dB(A)
؟The above data was measured in an anechoic
1. The cooling and heating capacities above show 2. The sound pressure level is based on the following
the maximum capacities when outdoor and indoor conditions: prior to installation
temperatures are under the following conditions: ؟1.5m beneath the unit
؟1.0m from discharge grille
Cooling Operation Conditions ؟The above data was measured in an anechoic
Indoor Air Inlet Temperature: 27ᵒC DB
19ᵒC WB prior to installation
Outdoor Air Inlet Temperature: 35ᵒC DB
Piping Length: 7.5m
0m
– –
the Technical Catalog. the Technical Catalog.
180 181
SPECIFICATION TABLES – CONTROLLER SYSTEMS SPECIFICATION TABLES – CONTROLLER SYSTEMS
– –
CENTRAL CENTRAL
STATION NT STATION EX
PSC-A128WEB3 PSC-A128EX
SPECIFICATION TABLES
Communication Method Half-Duplex Communication
Notes:
Outdoor Unit 64
Notes:
1. One external adapter can control [160 RC groups/128 groups/160 indoor units/64 outdoor units/Each layout],
and Central Station EX can connect up to 15 adapters
2. No restriction on the number of H-LINK
182 183
“If we are advertising
that the heating
SPECIFICATION TABLES
–
Mr Tomokazu Inaba,
Quality Assurance
184 185
–
Optional parts
& accessories
197 Cassette
200 Exposed
200 Ceiling Suspended
201 Wall Mounted
186 187
–
Customize
your order
Piping Outdoor Unit Capacity HP Class 5 6-10 12-16 18-20 22-24 26-54
Connection Kit
Multi-kit
First Branch kW 14 16.0-28.0 33.5-45.0 50.0-56.0 61.5-67.0 73.0-150.0
Multi-kit Multi-kit
(3-Portions) (3-Portions)
Multi-kit
(3-Portions)
Total Indoor Unit Connected Capacity (HP) <6 6-8.99 9-11.99 12-15.99 16-17.99 18-21.99 22-25.99 26-35.99 36≥
Multi-kit Multi-kit Header Branch
(3-Portions)
Diameter (mm) Gas Pipe 15.88 19.05 22.2 25.4 28.58 28.58 28.58 31.75 38.1
High/Low Pressure Gas Pipe 12.7 15.88 19.05 22.2 22.2 22.2 25.4 28.58 31.75
Liquid Pipe 9.52 9.52 9.52 12.7 12.7 15.88 15.88 19.05 19.05
Multi-kit
(2-Portions)
Total Indoor Unit Connected Capacity (HP) <6 6-8.99 9-11.99 12-15.99 16-17.99 18-25.99 26-35.99 36≥
Diameter (mm) Gas Pipe 15.88 19.05 22.2 25.4 28.58 28.58 31.75 38.1
OUTDOOR UNITS
Connectivity Number 2 2 3
NOTE: The old model (MC-TTA1) is not available. Multi-Kit Model MH-NP288X MH-NP224A MH-NP288A
Images: MH-NP224A
Gas Side Liquid Side Reducer
190 191
OPTIONAL PARTS & TREATMENTS – OUTDOOR UNITS OPTIONAL PARTS & TREATMENTS – OUTDOOR UNITS
– –
DRAIN BOSS CABINET COVER
THE DRAIN BOSS ALLOWS YOU TO ADAPT THE BASE OF THE OUTDOOR UNIT FOR USE AS A DRAIN PAN Snow Protection Hood
Outdoor Unit HP Class FSXNP series 5-14 16-24 26-32 34-36 38-42 44-46 48-50 52-54 FSXNS series 8-12 (22.4-33.5) 14-18 (40.0-50.0) 20-24 (56.0-67.0)
(kW) (14.0-40.0) (45.0-67.0) (73.0-90.0) (95.0-100.0) (106.0-118.0) (122.0-128.0) (136.0-140.0) (145.0-150.0) for Air Outlet
Snow Protection Zinc Coated Steel
FSXNS series 8-18 20-36 38-40 42-48 50-54 – – – Hood
(22.4-50.0) (56.0-100.0) (106.0-112.0) (118.0-136.0) (140.0-150.0) Upper ASG-TP50FA ASG-TP50FB ASG-TP50FC Outdoor unit
Air Inlet
Quantity 1 2 3 4 3 4 5 6 Rear ASG-TP50BA ASG-TP50BB ASG-TP50BC
Stainless
HP Class (kW) FSXNP series 5-6 (14.0-16.0) 8-14 (22.4-40.0) 16-18 (45.0-50.0)
FSXNS series 8-12 (22.4-33.5) 14-18 (40.0-50.0) 20-24 (56.0-67.0) Right side Rear side Foundation
Protection Net
HP Class (kW) FSXNP series 5-6 (14.0-16.0) 8-14 (22.4-40.0) 16-18 (45.0-50.0)
192 193
OPTIONAL PARTS & TREATMENTS – OUTDOOR UNITS OPTIONAL PARTS & TREATMENTS – OUTDOOR UNITS
– –
SALT DAMAGE CORROSION
RESISTANCE RESISTANCE
INSTALLATION LOCATIONS CORROSION-RESISTANCE IMPROVED HEAT EXCHANGER
A location not exposed to sea breezes, but within close proximity An area exposed to sea breezes but where the unit is not directly Hydrophilic film 2 x Longer
of the ocean. exposed to salt water.
Corrosion-resistant film
Anti-corrosive Treatment
2 x Longer
Sea Sea Phosphoric acid chromate treatment
Outdoor Unit Outdoor Unit
Corrosion-resistant film
Standard
Type of location • A location where the outdoor unit is rinsed by the rain • A location where the outdoor unit is not exposed to rain
• A location that is not exposed to sea breezes • A location directly exposed to sea breezes Hydrophilic film
• A location where the distance from the outdoor unit to the sea is • A location where the distance from the outdoor unit to the sea is
between 300m and 1km 300m or less
• A location where the outdoor unit is in the shelter of a building. • A location where the outdoor unit is mounted on the beach facing
side front of a building
• A location where iron roofs and steel parts near the outdoor unit
؟ Our technology was developed based on JRA9002: Criteria and Testing of Corrosion-
proof for Refrigeration and Air Conditioning Equipment against Salty Air.
؟ Please consult your Hitachi Cooling & Heating channel partner for more details.
؟ Please note that both “Anti-corrosive treatment” and “Heavy anti-corrosive treatment”
are options that must be custom ordered in addition to your outdoor unit.
For installation (Regarding SET FREE Σ outdoor units are made with strengthened materials and • Install the unit in a location that avoids direct sea water splashes and
maintenance and management) high quality coatings, but are not fully protected against corrosion. sea breezes.
؟ Install the unit on the leeward side of a building.
300m 500m 1,000m It may therefore be necessary to increase corrosion resistance by
؟ If you must install a unit facing the beach, protect it from direct sea
carrying out the following installation plans and maintenance work.
breezes with a wind-protective board.
؟ Please be careful about the direction of installation. (The degree of
1,000m
300m 500m
؟ Units that are resistant to salt damage are based on the “Standard of Testing Resistance to Salt Damage of Air
Conditioning Devices JRA9002” of the Japan Refrigeration and Air Conditioning Industry Association (JRAIA).
194 195
OPTIONAL PARTS – INDOOR UNITS OPTIONAL PARTS – INDOOR UNITS
– –
DUCTED CASSETTE
HIGH ESP & MEDIUM ESP 4-WAY CASSETTE
2 High humidity kit: use this kit for any situation where the
2 Flexible duct: Lengths of 1m, 2m, 3m and 5m (Φ200mm) temperature at the ceiling appears to be over 30ºC and the humidity
at the ceiling seems to be above RH80%
3 Blow unit:
؟ 3 Fresh air intake kit: fresh air aperture: two-chamber type (Φ75x2)
؟Can be hung in the case of a single one (middle hanging) (installation height: 55mm raised)
؟
4 Decorative panels:
4 Expansion nipple: ؟Neutral White, Beige, Grey, Black
؟
5 discharges air with ؟Equipped with Motion Sensor Kit
؟For high humidity levels
Space panel: please use these panels for handling the Space Panel
shallow ceiling cavity, and to prevent smudging. SINGLE Ceiling DOUBLE
؟ Ceiling
196 197
OPTIONAL PARTS – INDOOR UNITS OPTIONAL PARTS – INDOOR UNITS
– –
CASSETTE CASSETTE
2-WAY CASSETTE 1-WAY CASSETTE
1 Flexible duct Length: 1m, 2m, 3m and 5m [Φ150mm] Measurement of Height 780 780 1 Grille for front air discharge: In case of Clipped ceiling (one-way) Measurement of Height 870 870 870
External form type or Clipped ceiling (two-way) type External form
2 Blow unit: (mm) Width 1,580 1,940 (mm) Width 1,370 1,460 1,520
؟ 2 Aperture-shielding set: In case of Clipped ceiling (one-way) type or
؟Can be hung in the case of a single one (middle hanging) Depth 12 12 Clipped ceiling (two-way) type Depth 12 12 12
؟
3 Decorative panels: Neutral White, Beige, Gray, Black
3 Aperture-shielding set:
Wide panel (for renewal): Please choose 4 Receiver Kit: For Remote Controller (PC-AWR)
4 Filter box: the size of the wide panel according to the
measurements of an existing ceiling opening
5 Motion Sensor Kit Wide panel (for renewal): Please choose
83mm raised) the size of the wide panel according to the
and the measurements of an already-installed 6 measurements of an existing ceiling opening
indoor unit. ؟
5 ؟Standard
and the measurements of an already-installed
؟ ؟ indoor unit.
؟ ؟
hospitals and rest homes for the elderly ؟Standard
؟ ؟
7 Duct adapter: For fresh air absorption aperture [Φ100mm]
odors (such as ammonia odors), such as hospitals and rest homes Space panel: please use these panels for
handling the shallow ceiling cavity, and to
prevent smudging. Space panel: please use these panels for
؟ handling the shallow ceiling cavity, and to
6 Motion Sensor Kit
prevent smudging.
7 Receiver Kit: For Remote Controller (PC-AWR) in combination with space panels, you may ؟In addition, a shallower ceiling cavity can
not be able to do so because of the cradling handle double layers of space panels
8 structure of the ceiling
؟ ؟ In addition, a shallower ceiling cavity can
؟ handle double layers of space panels
؟
9 Decorative panels: Neutral White, Beige, Gray, Black SINGLE Ceiling DOUBLE SINGLE Ceiling DOUBLE
Ceiling Ceiling
10 Duct adapter: For fresh air absorption aperture
198 199
OPTIONAL PARTS – INDOOR UNITS OPTIONAL PARTS – INDOOR UNITS
– –
EXPOSED EXPOSED
CEILING SUSPENDED WALL MOUNTED
200 201
ACCESSORIES – CONTROLLER SYSTEMS: H-LINK ACCESSORIES – CONTROLLER SYSTEMS: H-LINK
– –
H-LINK ADAPTER H-LINK REMOTE-
PSC-5HA CONTROL ADAPTER
PSC-5RA
FOR CONNECTION TO “HA APPLIED RAC”
<< PSC-5HA>>
Centralized << PSC-5HA>>
Controller << PSC-5HA>>
Centralized
Controller Operation
Control Center
H-LINK Operation
Room Air Conditioner PSC-5HA
Control Cable Control Center
H-LINK
Operation
Outer Height 70.0 Room Air Conditioner Control Cable
Control Center
Dimensions
(mm) Width 230.0 H-LINK
؟ 1 unit of “HA applied RAC” requires 1 unit of PSC-5HA Individual Control Cable
Depth 200.0 ؟ Need to use H-LINK Adapter (PSC-5HA) to control “HA Applied” HA Applied RAC Cable for Remote Control Adapter
؟ Room Air Conditioner (including other companies’ RAC) via CS-NET PSC-5RA
HA Applied RAC H-LINK
Outer Height 40.0 Individual Control Cable
Dimensions Cable for Remote Control Adapter
(mm) Width 125.0
Depth 115.0 ؟ To connect the operation control center in the building,
one indoor unit by one PSC-5RA
CONTROLLER SYSTEMS – H-LINK
Centralized
Controller
Centralized
Controller
<< PSC-5HR>>
Depth 200.0 ؟ If the H-LINK length is more than 1,000 meters
؟ A maximum of four H-LINK relays can be installed
202 203
ACCESSORIES – CONTROLLER SYSTEMS: CENTRALIZED ACCESSORIES – CONTROLLER SYSTEMS: CENTRALIZED
– –
HC-A64BNP1 HARC70-P1
For BACnet® For LONWORKS ®
CONTROL UP TO 64 INDOOR UNITS BIGGER CONNECTION CAPACITY (UP TO 128 INDOOR UNITS)
Field-supplied Field-supplied
Corresponding BACnet® • ANSI/ASHRAE Standard 135-2004 BACnet® Connection Method to Upper • Connection by SNVT (Standard Network
Standard System Variable Type) to LONWORKS® Network
Control Item at Upper System • Run Stop (Setting) Quantity of Connection • 8 RCS Groups (Max. 128 indoor units)
• Operation Mode (Setting)
• Fan Speed Level (Setting) Control Item in Upper System •
• Indoor Temperature (Setting) (ng: 0~7) • Operation Mode Setting (nviMode_ng)
• Prohibiting RC Operation (Setting) • Temperature Setting (nviSetPoint_ng)
• Filter Sign Reset •
204 205
ACCESSORIES – CONTROLLER SYSTEMS: CENTRALIZED ACCESSORIES – CONTROLLER SYSTEMS: INDIVIDUAL
– –
HARC-BX 7-DAY TIMER
For LONWORKS ® PSC-A1T
CONNECT TO MULTIPLE H-LINK SYSTEMS WITH SCHEDULING OPERATION WITH
–
H-LINK LONWORKS*
Individual Control Cable
LONWORKS*
RAC ADAPTER
Standard
Monitoring Item at •
؟ 1 Mini Split unit requires 1 unit of RAC Adapter to control by CS-NET
Upper System (n: 0~7) • Inlet Air Temperature (nvoInletTemp_n)
؟ Some of the Mini Split units are not compatible with CS-NET
؟ Please consult your Hitachi Cooling & Heating channel partner for more information Hitachi Cooling & Heating Mini Splits
206 207
ACCESSORIES – CONTROLLER SYSTEMS: INDIVIDUAL ACCESSORIES – CONTROLLER SYSTEMS: INDIVIDUAL
– –
3P CONNECTOR CABLE REMOTE CONTROL CABLE
PCC-1A PRC-5K, 10K, 15K
<<PCC-1A>>
3
FOR CONNECTION TO REMOTE ON/OFF FOR PC-ARF AND PC-AR
Temperature
Increase
Indoor Unit PCB ؟ Neither PC-AR or PC-ARF include
a remote control cable
؟ Use this cable if you don’t have
H-LINK
Individual Control Cable <<PRC-5K, 10K,<<PRC-5K,
15K>> 10K, 15K>>
Temperature
Heating Operation: Increase
Compressor is ON by closing terminals 1 and 2 of CN3 Indoor Unit PCB
Compressor is OFF by opening terminals 1 and 2 of CN3
THM-R2A
PC-ALH3 PC-ALHC1 PC-ALHD1 PC-ALHS1 PC-ALHP1 PC-ALHZ1
TO SENSE THE INDOOR
Dimensions Height 36.0 35.0 27.5 25.0 23.0 28.0
TEMPERATURE (mm)
Width 203.0 207.4 135.4 102.0 102.0 120.0
H-LINK
Remote Sensor Cable <<THM-R2A>>
For indoor 4-Way 4-Way 2-Way 1-Way Ceiling Ducted Floor Floor Floor/Ceiling Wall
؟ When the room temperature sensing thermistor unit model Cassette Cassette Cassette Cassette Suspended Exposed Concealed Convertible Mounted
(Remote Sensor) is attached to the auxiliary connector, Compact
the unit is controlled at average air temperature at the
indoor inlet and Remote Sensor
H-LINK point
؟ Not compatible with WallRemote Sensor
Type (RPK) Cable
indoor unit <<THM-R2A>>
–
For more information about options and accessories,
please consult your Hitachi Cooling & Heating channel
partner.
208 209
–
SERVICE & SUPPORT
Four lines of placeholder content goes here. Localized Four lines of placeholder content goes here. Localized
content means this will change between markets. Four lines content means this will change between markets. Four lines
of placeholder content goes here. Localized content means of placeholder content goes here. Localized content means
this will change between markets. Four lines of placeholder this will change between markets. Four lines of placeholder
content goes here. content goes here.
– –
SERVICE
Network (Dealers, Distribution Partners, etc) Speedy Repair Support (Within 24 Hours)
Four lines of placeholder content goes here. Localized Four lines of placeholder content goes here. Localized
content means this will change between markets. Four lines content means this will change between markets. Four lines
of placeholder content goes here. Localized content means of placeholder content goes here. Localized content means
this will change between markets. Four lines of placeholder this will change between markets. Four lines of placeholder
content goes here. content goes here.
– –
Availability Of Spare Parts
• Five lines of placeholder content in bullet style Four lines of placeholder content goes here. Localized
• Five lines of placeholder content in bullet style content means this will change between markets. Four lines
• Five lines of placeholder content in bullet style of placeholder content goes here. Localized content means
• Five lines of placeholder content in bullet style this will change between markets. Four lines of placeholder
• Five lines of placeholder content in bullet style content goes here.
– –
Support For Product Disposal And Recycling Warranty Management System
Four lines of placeholder content goes here. Localized Four lines of placeholder content goes here. Localized
content means this will change between markets. Four lines content means this will change between markets. Four lines
of placeholder content goes here. Localized content means of placeholder content goes here. Localized content means
this will change between markets. Four lines of placeholder this will change between markets. Four lines of placeholder
content goes here. content goes here.
–
Your local Hitachi Cooling & Heating supplier will have more
information, please get in touch with them for your service needs.
210 211
–
Disclaimer
The information in this document is for general information purposes
only and is correct at the time of publication. As this information may
change without warning, please understand that the information in
this document may not apply if the document is referred to at a later
date. Johnson Controls Hitachi shall not be liable for any special,
direct, indirect, consequential, or incidental damages or any damages
whatsoever, whether in an action of contract, negligence or other tort,
arising out of or in connection with the use of this document or the
contents of this document. Johnson Controls Hitachi reserves the right
document at any time without prior notice. Version 1.0 July 2018