0% found this document useful (0 votes)
421 views2 pages

5800pir Res Install Guide

This document provides installation instructions for a 5800PIR-RES wireless motion sensor. It includes details on: 1. Locating and mounting the sensor, connecting the battery, and enrolling it with the control panel. 2. Conducting walk tests and troubleshooting issues like low battery messages. 3. Specifications of the sensor such as its operating temperature range, battery type, detectable walk rate, and approvals.

Uploaded by

Jesus Hinostroza
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
421 views2 pages

5800pir Res Install Guide

This document provides installation instructions for a 5800PIR-RES wireless motion sensor. It includes details on: 1. Locating and mounting the sensor, connecting the battery, and enrolling it with the control panel. 2. Conducting walk tests and troubleshooting issues like low battery messages. 3. Specifications of the sensor such as its operating temperature range, battery type, detectable walk rate, and approvals.

Uploaded by

Jesus Hinostroza
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

5800PIR-RES Wireless Motion Sensor - Installation Instructions

1 LOCATION / EMPLACEMENT 2 OPEN /


No / Non / No OUVERTURE
Satisfactory /
Satisfaisant /
Satisfactorio

7.5 - 8 ft 1
(2.3 - 2.4 m)

3 CONNECT THE BATTERY, ENROLL THE 4 MOUNT / INSTALLATION


SENSOR, CONDUCT GO / NO GO TEST,
AND PERFORM WALK TEST / METTRE 1
LES PILES EN PLACE , TOP
ENROLL
Panasonic CR123A / SENSOR, CONDUCTSee
THE GOpage
/ NO2GOfor
Duracell DL123A
TEST, AND/ PERFORM WALK TESTmore information /
Honeywell 466 See page 2 for
more information
- Use only left OR right side
corner mounting holes.

Observe
correct polarity /
Observe correct
polarity
Recommended
Screws: #6 (3.5 mm)
2

A DETECTION PATTERNS / COUVERTURE DE B ACCESSORIES / ACCESSOIRES


DETECTION
35' / 11m Wide Angle Animal Immune Lens
(P/N 5-532-719-00) SMB-10
1
Swivel Mount Bracket
Top View / Vue de Dessus (P/N 0-000-110-01)
7' 13' 20' 27' 35'
20' 0 2m 4m 6m 8m 11m SMB-10C Swivel Mount Ceiling Bracket
6m (P/N 0-000-111-01)
1
2
13' 1
3 SMB-10T Swivel Mount Bracket w/Tamper
4m
(P/N 0-000-155-01)
12 4
7' 1
IS2500-HSLK High Security Lens Kit
2m 18 13
5 35’ x 40’ (11 m x 12 m)
14 2
0 19 6 IS2500-PALK Pet Alley Lens Kit
15
35’ x 40’ (11 m x 12 m)
7
7' 20 16 1
2m Not verified by ETL.
17 8 1
Mounting Height: 7 – 9 ft (2.1 m – 2.7 m).
13'
4m
9 Hauteur de montage: 2
4 ft (1.2 m).
10 Altura de la instalación:
11
20'
6m

Side View / Vue de Cote


7' 13' 20' 27' 35'
7'6" 0 2m 4m 6m 8m 11m
(2.3m)

PRELIMINARY DRAFT 8/24/09 -1-


5800PIR-RES Wireless Motion Sensor - Installation Instructions
ENROLL THE SENSOR TROUBLESHOOTING
Enroll the sensor in the control panel prior to its usage in the Problem: The system displays a “low battery” message.
system. Refer to the control panel instructions for programming Solution: Replace the battery within 7 days.
details. Program the sensor as an “RF” type (supervised
RF) device. SPECIFICATIONS
To enroll: connect the battery and wait for power up to end Power: Battery* (included). 1 x 3 V, Lithium;
(see LED Indications table). When prompted for the serial CR123A / DL 123A / 466
number, activate the sensor (wave a hand in front of the lens) Battery Life, years (typical): 5
to enroll the sensor.
RF Frequency: 345 MHz
Loop 1 Pulse count 2; Up to 80 lbs. Animal Immunity
Operating Temperature: 14° to 131° F (-10° to 55° C)
(for indoor use environment)
LED INDICATIONS
Relative Humidity, no 95% max.
Condition Indicator LED condensation:
Power Up Blinks once per second (for < 45 seconds) Detectable Walk Rate: 0.7 – 7ft/Sec. (0.2 – 2.0m/Sec.)
Walk Test ON for 3 seconds = Loop 1 / Low Sensitivity Alarm
Flickers rapidly for 3 seconds = walk test period ended
Temperature Compensation: Advanced Dual Slope
* Battery Caution: Risk of fire, explosion and burns. Do not recharge,
MOUNT THE SENSOR (See page 1) disassemble, heat above 212° F (100° C), or incinerate. Dispose of
used batteries promptly. Keep away from children.
Before mounting the transmitter permanently, conduct Go/No
Go tests (see control panel manual) to verify adequate signal APPROVALS / LISTINGS
strength and reorient or relocate the sensor if necessary. • FCC part 15, Class B verified
For Animal (Pet) Immunity: • IC, ICES-003, Class B verified
• Install the sensor where animals cannot come within 6 ft • C-Tick
(1.8 m) of the sensor by climbing on furniture or other
• CE
objects.
• Aim the sensor away from stairways, furniture or other • SIA-PIR-01 Passive Infrared detector standard features
objects that can be climbed on by animals. for false alarm immunity.
• Do not use optional swivel mount brackets. • cETLus Listed
COMPLIANCE NOTES
WALK TESTING • Product must be tested at least once each year.
The 10 minute walk test mode begins after power up, and can • Product must be installed within the protected area only.
be restarted by removing and replacing the battery.
As you walk through the detection pattern, the sensor LED will
light for 3 seconds to indicate each alarm detection.
Note: In walk test mode all transmissions will be sent as they
occur. During normal operation, only one transmission
sequence will occur within a 3-minute period to conserve
battery life.

FCC NOTICE: This equipment has been tested and found to comply with the limits for a Class B The user is cautioned that changes or modifications not expressly approved by Honeywell could
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide void the user’s authority to operate this equipment.
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in IC NOTICE: This Class B digital device complies with the Canadian ICES-003.
accordance with the instructions, may cause harmful interference to radio communications. Cet appareil numérique de la Classe B est conforme à la norme NMB-003 du Canada.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be This device complies with RSS-210 of the IC rules. Operation is subject to the following two
determined by turning the equipment off and on, the user is encouraged to try to correct the conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference by one or more of the following measures: interference received, including interference that may cause undesired operation.
− Reorient or relocate the receiving antenna. Cet appareil est conforme à la norme CNR-210 des règles d’IC. L’utilisation de ce dispositif est
− Increase the separation between the equipment and receiver. autorisée seulement aux deux conditions suivantes ; (1) il ne doit pas produire de brouillage, et (2)
− Connect the equipment into an outlet on a circuit different from that to which the receiver is l’utilisateur du dispositif doit être prêt à accepter tout brouillage radioélectrique reçu, même si ce
connected. brouillage est susceptible de compromettre le fonctionnement du dispositif.
− Consult the dealer or an experienced radio/television technician for help.

To obtain applicable EU compliance Declaration of Conformity for this product, please refer to our Website, http://www.security.honeywell.com/hsce/international/index.html.

 2009 Honeywell International Inc. Honeywell is a registered trademark of Honeywell International Inc.
All other trademarks are the properties of their respective owners. All rights reserved. Assembled in Mexico.
For the latest U.S. warranty information, please go to: www.honeywell.com/security/hsc/resources/wa or
Please contact your local authorized Honeywell representative for product warranty information.
Ê800-04182&Š
P/N 800-04182 Rev A 8/09

PRELIMINARY DRAFT 8/24/09 -2-

You might also like