PTC10/PTR10 Wireless Thermostat Manual
PTC10/PTR10 Wireless Thermostat Manual
User Manual
Wireless Programmable
Room Thermostat
1. Overview 01 This wireless programmable room thermostat kit can be used to control gas or oil boiler,
a variety of valves and actuators.
2. System Installation 02
It contains a wireless programmable room thermostat PTC10 and a wireless receiver
2.1 Install and Wiring Receiver 02 PTR10, the two units are linked by Radio Frequency.(If your kit is Wi-Fi thermostat,
2.1.1 Install Receiver 02 there is a gateway PTG10 accessing your thermostat to internet)
2.1.2 Wiring Receiver 03 This thermostat is a programmable room thermostat 5+2 Days / 7 Days/1 day product.
5+2 days allows you to set a program for weekdays and a program for the weekend. 7
2.2 Activate Batteries and Install Thermostat 06
days allows you to set a same program for every day of the week. 1 day functionality
2.2.1 Activate Batteries 06 allows you to set a different program for every day of the week. Each program type
allows you to set 7 time and temperature events.
2.2.2 Install Thermostat 06
2.3 System Check 07 Controls and Display Layout
2.3.1 RF Signal Pairing 07 H I
A Days
2.3.2 RF communication test 14
B Temperature
16 A
3. Operation Thermostat C Program setting time
3.1 Clock Setting 16 D ECO J
3.2 Program Setting 18 + or - buttons for setting
E adjustment
B K
3.2.1 Pre-set Program 18
F Confirm C
3.2.2 To adjust the Pre-set Program 18
G Return
3.3 Override Mode 21
H Auto, Manual, Holiday mode
3.4 Manual Mode 22
I RF
3.5 Holiday Mode 23 D E F E G
J Time
3.6 ECO Mode 24
K Humidity
3.7 OFF Mode(Frost Protection) 25
LEARN MODE
LEARN
Copy Clock set
LEARN MODE
3.8 Child Lock 25 OVERRIDE A
Child lock
4. User Option 26 Program set OVERRIDE B
5
appropriately (5A max.).
Note: 3 The Receiver should be mounted in a location where it will not come into contact Close the
with water, moisture or condensation. upper cover
NL ABCABC
Note: 5 Poer accepts no liability for any loss or damage arising from any errors or
3 4
omissions that may be inadvertently contained within these diagrams. They are proposal
Loosen the screws on terminals, diagrams only, not certified wiring diagrams.
Fasten the terminal base
wiring the terminal correctly, then
on wall with 4 screws.
fasten the screws.
2. System Installation 04 2. System Installation 05
24V-230V~
PTR 10 50/60HZ
A-C:5A
N L A B C A B C B-C:5A
100-230V~ L
N L A B C A B C
100-230V~ 50/60Hz call for heating Common call for heating Common 50/60Hz
<5A N
heat satisfide heat satisfide L Max
or call or call 1.2KW
forcooling forcooling N
24V-230V~
PTR 10 50/60HZ
A-C:5A
24V-230V~
B-C:5A PTR 10 50/60HZ
A-C:5A
B-C:5A
100-230V~ L
N L A B C A B C
50/60Hz 100-230V~
<5A N N L A B C A B C
L 50/60Hz
<5A R B BR BL
L
N
N
24V-230V~ 24V-230V~
PTR 10 50/60HZ
A-C:5A
T1 PTR 10 50/60HZ
A-C:5A
O
B-C:5A B-C:5A
T2 GR
100-230V~ L 100-230V~ BR
N L A B C A B C N L A B C A B C
50/60Hz 50/60Hz M
L <5A N L <5A BL
N N G/Y
2. System Installation 06 2. System Installation 07
3 Press OVERRIDE Ⅰ or Ⅱ (you must choose according to your real wiring work on
receiver) to pair with thermostat; when light of OVERRIDE Ⅰor Ⅱ is flashing, it means
OVERRIDE Ⅰor Ⅱ is ready to pair with thermostat next.
81.5mm
4mm
81.5mm
2. System Installation 08 2. System Installation 09
(4-2)When is flashing on the screen’s left side, press to send the pairing B. RF signal pairing between room thermostat and gateway (this is only for Wi-Fi
command with receiver; thermostat)
Pairing success if flashing on screen’s right side, pairing failed if E01 or E02 is
flashing on screen’s right side, in this case, you need to send the paring command with 1 Automatically pairing thermostat with gateway by App.on mobile phone
receiver by pressing once again until pairing success. (1-1)Open the App. which already connected with gateway(how to add a gateway on
App. please refer to gateway’s manual for details), choose Add Thermostat from the
interface;
succeed
failed
5 Exit pairing mode: Exit pairing mode by pressing LEARN button; thermostat’s HOME
page can be returned by keep pressing .
6 Once thermostat and receiver was paired successfully, their RF communication started
normally, will show up on the top right corner of thermostat’s screen.
2. System Installation 10 2. System Installation 11
(1-3)Pairing process between thermostat and gateway might take about 1 minute. Once
thermostat is paired with gateway successfully, will show up on the top right corner
of thermostat’s screen; App. interface also show up the added thermostat’s information.
2 Manually paring thermostat with gateway
( 2-1) Preparation: Powered gateway correctly by plug-in socket, the LED on gateway
will be blinking rapidly (LED blinking rapidly means no connection between gateway and
server).
(2-2)Start gateway’s pairing mode by hold pressing until its LED is blinking slowly.
(2-3-1)Long press to enter Menu Selection, when are flashing, (2-4)Gateway is still under paring mode even one thermostat's paring succeed, if you
press to enter RF pairing interface. had more thermostats need to be paired, you may continue to pair them with gateway
manually. (1 gateway could RF communicate with 10 thermostats at one time).
(2-5)Exit pairing mode by hold-pressing until the LED recover to its status before
pairing.
( 2-6) Once thermostat and gateway was paired successfully, their RF communication
started normally, will show up on the top right corner of thermostat’s screen; App.
interface also show up the added thermostat’s information.
succeed
failed
2. System Installation 14 2. System Installation 15
good
bad
good bad
3. Operation Thermostat 16 3. Operation Thermostat 17
3.1 Clock Setting 3 When appeared on Temperature Area, press to select current
month and press to set.
Clock setting should be done if thermostat was used for the first time or after batteries
changed; automatically clocking setting will be done if thermostat was connected with
Internet via Gateway.
2 Firstly set Year after entered Clock Setting, when appeared on Temperat-ure
5 When clock setting is flashing on Time Area, press to select current
Area, press to select current year and press to set.
time and press to confirm.
Hour Second
3.2 Program Setting 2 Enter 5+2 days/7 days/1 day program when Days flashing, select by ;
press to confirm.
3.2.1 Pre-set Program
This thermostat comes with the following default settings pre-programed for your 5+2 Days Program
convenience:
Event 1 2 3 4 5 6 7
Time 00:00 6:30 8:30 12:00 14:00 16:30 22:30
Temperature 7 20 16 16 16 21 7
4 Time flashing in Time Area, press to adjust the 1st time as required,
3.3 Override Mode-to change temperature for a
press to confirm.
short period under AUTO mode
st
5 Once the temperature and 1 time has been set, temperature flashing in Temperature
Area again, then you repeat to set the next temperature and time periods, as above steps
showing (checking from Step 3).
7 Long press can copy current flashing day’s program setting to other day;
select target day by pressing , long press to confirm and paste.
3.4 Manual Mode-to set a constant room temperature manually 3.5 Holiday Mode
1 Switch between AUTO and Manual Mode by pressing . Make a holiday plan, it will keep your room at the pre-set temperature until your return time
is coming. The default temperature for Holiday Mode is 7℃, you also can change this
default value in User Options.
2 Under Manual mode, appeared on upper right and temperature flashing.
Figure as following. 1 Enter Holiday Mode by keep pressing until showing on upper right.
3 Adjust required temperature by pressing or , confirm after ★ Holiday start date: adjust by pressing as following figure, confirm
flashing for 7 sec. or pressing , then continue to show current temperature. by pressing .
Month Date
3. Operation Thermostat 24 3. Operation Thermostat 25
★ Holiday start time: adjust by pressing 3.7 OFF Mode (Frost Protection)
as following figure, confirm by pressing
. Under OFF Mode, your room’s Frost Protection will be automatically turned on unless you
exit the mode; The default temperature is 7℃, you can change this default value in User
Options.
Hour Second
3 Holiday Mode will start automatically when holiday start time is coming, otherwise, it
continue AUTO Mode.
4 To cancel Holiday Mode’s setting by keep pressing. 2 Exit OFF Mode by pressing .
It is an quick access to energy saving but also maintain comfort. Under ECO Mode, the To avoid wrong operation by child, this thermostat has Child Lock function; once started
room will be always kept at a pre-set temperature unless you exit this mode. The default this function, there will be no reaction if short press on any button.
temperature is 9℃, you can change this default value in User Options.
1. You may change user operation after entered User Operation by Pressing
ID Option Content Min. Max. Default
when is flashing under Menu Selection.
4. To cancel User Operation’s setting, press when Option Content flashing. OFF
Activate Smart Remote
12 Control (App remote control) OFF ON (ON for Wi-Fi
thermosta)
5. To exit User Operation’s setting, press when Option ID flashing
6. Product Specification 28 6. Product Specification 29
IP class IP30
Standard CE