PTC10/PTR10 Wireless Thermostat Manual

This document provides instructions for installing and setting up a wireless programmable room thermostat and receiver. It includes directions for installing the receiver, connecting wiring to the receiver terminals, activating batteries in the thermostat, installing the thermostat on the wall, pairing the thermostat and receiver using radio frequency, and testing the communication between the devices. The thermostat can be used to control heating systems and has programming options to set schedules and temperatures.

Uploaded by

tufta tufta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
637 views16 pages

PTC10/PTR10 Wireless Thermostat Manual

This document provides instructions for installing and setting up a wireless programmable room thermostat and receiver. It includes directions for installing the receiver, connecting wiring to the receiver terminals, activating batteries in the thermostat, installing the thermostat on the wall, pairing the thermostat and receiver using radio frequency, and testing the communication between the devices. The thermostat can be used to control heating systems and has programming options to set schedules and temperatures.

Uploaded by

tufta tufta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

smart controls

User Manual
Wireless Programmable
Room Thermostat

Model No.: PTC10 / PTR10

Hangzhou Poer Tech., Co., Ltd


Add.: 19th. Floor, Xingtu Building, No.451 Tel.: +86-571-85800292
Wulianwang Street, Binjiang Zone, Hangzhou Fax: +86-571-28190666
City, 310051 Zhejiang Pro., CHN. E-mail: [email protected] Power to control your heating
www.poersmart.com Scan for App Anytime, Anywhere
Contents 1. Overview 01

1. Overview 01 This wireless programmable room thermostat kit can be used to control gas or oil boiler,
a variety of valves and actuators.
2. System Installation 02
It contains a wireless programmable room thermostat PTC10 and a wireless receiver
2.1 Install and Wiring Receiver 02 PTR10, the two units are linked by Radio Frequency.(If your kit is Wi-Fi thermostat,
2.1.1 Install Receiver 02 there is a gateway PTG10 accessing your thermostat to internet)

2.1.2 Wiring Receiver 03 This thermostat is a programmable room thermostat 5+2 Days / 7 Days/1 day product.
5+2 days allows you to set a program for weekdays and a program for the weekend. 7
2.2 Activate Batteries and Install Thermostat 06
days allows you to set a same program for every day of the week. 1 day functionality
2.2.1 Activate Batteries 06 allows you to set a different program for every day of the week. Each program type
allows you to set 7 time and temperature events.
2.2.2 Install Thermostat 06
2.3 System Check 07 Controls and Display Layout
2.3.1 RF Signal Pairing 07 H I
A Days
2.3.2 RF communication test 14
B Temperature
16 A
3. Operation Thermostat C Program setting time
3.1 Clock Setting 16 D ECO J
3.2 Program Setting 18 + or - buttons for setting
E adjustment
B K
3.2.1 Pre-set Program 18
F Confirm C
3.2.2 To adjust the Pre-set Program 18
G Return
3.3 Override Mode 21
H Auto, Manual, Holiday mode
3.4 Manual Mode 22
I RF
3.5 Holiday Mode 23 D E F E G
J Time
3.6 ECO Mode 24
K Humidity
3.7 OFF Mode(Frost Protection) 25

LEARN MODE
LEARN
Copy Clock set
LEARN MODE
3.8 Child Lock 25 OVERRIDE A
Child lock
4. User Option 26 Program set OVERRIDE B

5. User Options Table 27 Forst protection


6. Product Specification 28 Heating
Wireless Programmable Thermostat 28 Low bettery warning
Wireless Receiver 29 Open window
2. System Installation 02 2. System Installation 03

2.1 Install and Wiring Receiver

2.1.1 Install Receiver


Follow the installation diagrams to install and connect the receiver PTR10 correctly.
Note: 1 The installation and wiring should be operated by trained personel.
Note: 2 The Receiver should be mounted in a suitable location that is both accessible for Pressing area
the connection of mains and control wiring, and allows good reception of the RF signal.
The Receiver needs a 100~240V AC mains supply to operate, and this should be fused

5
appropriately (5A max.).

Note: 3 The Receiver should be mounted in a location where it will not come into contact Close the
with water, moisture or condensation. upper cover

NL ABCABC

6 Press the area as below picture mentioned,


fasten the screw after make sure no gap
between upper and lower covers, as well as
all the terminals well connected.

1 Loosen the screw on the


receiver’s bottom.(No need
to screw out completely)
2 Open the upper cover.
2.1.2 Wiring Receiver

Note: 1 Install in accordance with local wiring regulations.

Note: 2 The wiring should be operated by trained personnel.

Note: 3 Observe ambient temperature and current limits(see product specification).


max 2.5mm2
Note: 4 These diagrams must be read in conjunction with any boiler or cylinder manufac-
tures instructions.
NL ABCABC
NL ABCABC

Note: 5 Poer accepts no liability for any loss or damage arising from any errors or

3 4
omissions that may be inadvertently contained within these diagrams. They are proposal
Loosen the screws on terminals, diagrams only, not certified wiring diagrams.
Fasten the terminal base
wiring the terminal correctly, then
on wall with 4 screws.
fasten the screws.
2. System Installation 04 2. System Installation 05

Volt free contacts Electric heater

24V-230V~
PTR 10 50/60HZ
A-C:5A
N L A B C A B C B-C:5A

100-230V~ L
N L A B C A B C
100-230V~ 50/60Hz call for heating Common call for heating Common 50/60Hz
<5A N
heat satisfide heat satisfide L Max
or call or call 1.2KW
forcooling forcooling N

Burner(direct control) Thermal actuator

24V-230V~
PTR 10 50/60HZ
A-C:5A
24V-230V~
B-C:5A PTR 10 50/60HZ
A-C:5A
B-C:5A
100-230V~ L
N L A B C A B C
50/60Hz 100-230V~
<5A N N L A B C A B C
L 50/60Hz
<5A R B BR BL
L
N
N

Combi boiler Zone valve

24V-230V~ 24V-230V~
PTR 10 50/60HZ
A-C:5A
T1 PTR 10 50/60HZ
A-C:5A
O
B-C:5A B-C:5A
T2 GR

100-230V~ L 100-230V~ BR
N L A B C A B C N L A B C A B C
50/60Hz 50/60Hz M
L <5A N L <5A BL

N N G/Y
2. System Installation 06 2. System Installation 07

2.2 Activate Batteries and Install Thermostat 2.3 System Check

2.2.1 Activate Batteries 2.3.1 RF Signal Pairing

The room thermostat has already been pre-bound with receiver’s

i OVERRIDE Ⅰ in kit PS15WKQ1020 when delivery. You may directly


move to RF communication test, please refer to 2.3.2.

A. RF signal pairing between room thermostat and receiver

Insert batteries, ensure


Remove the battery cover Close the battery cover 1 Preparation: thermostat and receiver should be powered/wired correctly, make sure the
correct orientation
visible distance between thermostat and receiver is not more than 5 meters.

2.2.2 Install Thermostat


2 Start receiver’s RF paring mode by hold-pressing the LEARN button until its light
This thermostat could be desk-stand if open the back support, you just need to place it on
flashing.
any flat surface allows to receive RF signal.

3 Press OVERRIDE Ⅰ or Ⅱ (you must choose according to your real wiring work on
receiver) to pair with thermostat; when light of OVERRIDE Ⅰor Ⅱ is flashing, it means
OVERRIDE Ⅰor Ⅱ is ready to pair with thermostat next.

4 Thermostat send pairing command with receiver:

(4-1)Long press to enter Menu Selection, select by pressing or


If you want to hang it on the wall, use the template provided. when are flashing, press to enter RF pairing interface.
Drill two holes in the wall and tighten the screws, ensuring two holes’ distance is 81.5mm;
then, fix the thermostat’s back cover by putting it over the screw head.

81.5mm

4mm
81.5mm
2. System Installation 08 2. System Installation 09

(4-2)When is flashing on the screen’s left side, press to send the pairing B. RF signal pairing between room thermostat and gateway (this is only for Wi-Fi
command with receiver; thermostat)
Pairing success if flashing on screen’s right side, pairing failed if E01 or E02 is
flashing on screen’s right side, in this case, you need to send the paring command with 1 Automatically pairing thermostat with gateway by App.on mobile phone
receiver by pressing once again until pairing success. (1-1)Open the App. which already connected with gateway(how to add a gateway on
App. please refer to gateway’s manual for details), choose Add Thermostat from the
interface;

succeed

failed

5 Exit pairing mode: Exit pairing mode by pressing LEARN button; thermostat’s HOME
page can be returned by keep pressing .

6 Once thermostat and receiver was paired successfully, their RF communication started
normally, will show up on the top right corner of thermostat’s screen.
2. System Installation 10 2. System Installation 11

(1-2)Add thermostat by scanning it's QR code or typing MAC ID manually.

(1-3)Pairing process between thermostat and gateway might take about 1 minute. Once
thermostat is paired with gateway successfully, will show up on the top right corner
of thermostat’s screen; App. interface also show up the added thermostat’s information.
2 Manually paring thermostat with gateway

( 2-1) Preparation: Powered gateway correctly by plug-in socket, the LED on gateway
will be blinking rapidly (LED blinking rapidly means no connection between gateway and
server).

(2-2)Start gateway’s pairing mode by hold pressing until its LED is blinking slowly.

(2-3)Thermostat send pairing command with gateway.


2. System Installation 12 2. System Installation 13

(2-3-1)Long press to enter Menu Selection, when are flashing, (2-4)Gateway is still under paring mode even one thermostat's paring succeed, if you
press to enter RF pairing interface. had more thermostats need to be paired, you may continue to pair them with gateway
manually. (1 gateway could RF communicate with 10 thermostats at one time).

(2-5)Exit pairing mode by hold-pressing until the LED recover to its status before
pairing.

( 2-6) Once thermostat and gateway was paired successfully, their RF communication
started normally, will show up on the top right corner of thermostat’s screen; App.
interface also show up the added thermostat’s information.

(2-3-2)On RF pairing interface, select by pressing on or until flashing


show up on screen’s left side, press to send thermostat’s paring commend
to gateway; pairing success if flashing on screen’ s right side, pairing failed if E01
or E02 is flashing on screen’s right side, in this case, you need to send the paring
command with gateway by pressing once again until pairing success.

succeed

failed
2. System Installation 14 2. System Installation 15

2.3.2 RF communication test 2 RF communication test between thermostat and gateway


To make sure RF communication between thermostat and receiver, thermostat and Enter RF Communication Test by long pressing , when show up on screen’s
gateway before using them regularly, you should take a RF communication test. left side, press to test RF communication between thermostat and gateway; test
result is good if show up on screen’s right side, otherwise, will show
1 RF communication test between thermostat and receiver
up on screen’s right side, in this case, you need relocate the thermostat and do the test
Enter RF Communication Test by long pressing , when show up on screen’s
once again.
left side, presse to test RF communication between thermostat and receiver; test
result is good if show up on screen’s right side, otherwise, will show
up on screen’s right side, in this case, you need relocate the thermostat and do the test
once again.

good

bad
good bad
3. Operation Thermostat 16 3. Operation Thermostat 17

3.1 Clock Setting 3 When appeared on Temperature Area, press to select current
month and press to set.
Clock setting should be done if thermostat was used for the first time or after batteries
changed; automatically clocking setting will be done if thermostat was connected with
Internet via Gateway.

1 Enter Menu Selection by long pressing , select by until


there is a flashing , then enter Clock Setting by pressing .

4 When appeared on Temperature Area, press to select current


date and press to set.

2 Firstly set Year after entered Clock Setting, when appeared on Temperat-ure
5 When clock setting is flashing on Time Area, press to select current
Area, press to select current year and press to set.
time and press to confirm.

Hour Second

6 Back to the last setting menu by pressing .


3. Operation Thermostat 18 3. Operation Thermostat 19

3.2 Program Setting 2 Enter 5+2 days/7 days/1 day program when Days flashing, select by ;
press to confirm.
3.2.1 Pre-set Program
This thermostat comes with the following default settings pre-programed for your 5+2 Days Program
convenience:

Working days’ pre-set program

Event 1 2 3 4 5 6 7
Time 00:00 6:30 8:30 12:00 14:00 16:30 22:30
Temperature 7 20 16 16 16 21 7

Weekend’s pre-set program (Sat., Sun.)

5 7 Days Program 1 Day Program


Event 1 2 3 4 6 7
Time 00:00 7:00 9:00 12:00 14:00 16:30 23:00
Temperature 7 20 18 21 18 21 7

3.2.2 To adjust the pre-set program


1 Enter Program Setting by Pressing when is flashing.

Program Setting menu


3 Temperature flashing in Temperature Area, press to adjust required
temperature, press to confirm.
3. Operation Thermostat 20 3. Operation Thermostat 21

4 Time flashing in Time Area, press to adjust the 1st time as required,
3.3 Override Mode-to change temperature for a
press to confirm.
short period under AUTO mode

1 Under AUTO mode, enter Override mode by pressing or ,


appeared on upper right.

2 Adjust required temperature by pressing or , confirm the


override temperature after flashing for 7 sec. or pressing , then continue to show
current temp-erature.

st
5 Once the temperature and 1 time has been set, temperature flashing in Temperature
Area again, then you repeat to set the next temperature and time periods, as above steps
showing (checking from Step 3).

6 To cancel the program by pressing , go back to Menu Selection by keeping


pressing.

7 Long press can copy current flashing day’s program setting to other day;
select target day by pressing , long press to confirm and paste.

3 Exit Override Mode until next change in the preset program.


3. Operation Thermostat 22 3. Operation Thermostat 23

3.4 Manual Mode-to set a constant room temperature manually 3.5 Holiday Mode

1 Switch between AUTO and Manual Mode by pressing . Make a holiday plan, it will keep your room at the pre-set temperature until your return time
is coming. The default temperature for Holiday Mode is 7℃, you also can change this
default value in User Options.
2 Under Manual mode, appeared on upper right and temperature flashing.
Figure as following. 1 Enter Holiday Mode by keep pressing until showing on upper right.

2 Pre-set date and time for holiday start and return.

3 Adjust required temperature by pressing or , confirm after ★ Holiday start date: adjust by pressing as following figure, confirm
flashing for 7 sec. or pressing , then continue to show current temperature. by pressing .

Month Date
3. Operation Thermostat 24 3. Operation Thermostat 25

★ Holiday start time: adjust by pressing 3.7 OFF Mode (Frost Protection)
as following figure, confirm by pressing
. Under OFF Mode, your room’s Frost Protection will be automatically turned on unless you
exit the mode; The default temperature is 7℃, you can change this default value in User
Options.

Hour Second

1 Enter OFF Mode by long pressing ,


★ Return date and time’s pre-set: once Holiday Start’s date and time has been set, start
following is the figure:
to set return date and time in the same way.

3 Holiday Mode will start automatically when holiday start time is coming, otherwise, it
continue AUTO Mode.

4 To cancel Holiday Mode’s setting by keep pressing. 2 Exit OFF Mode by pressing .

3.6 ECO Mode 3.8 Child Lock

It is an quick access to energy saving but also maintain comfort. Under ECO Mode, the To avoid wrong operation by child, this thermostat has Child Lock function; once started
room will be always kept at a pre-set temperature unless you exit this mode. The default this function, there will be no reaction if short press on any button.
temperature is 9℃, you can change this default value in User Options.

1 Long press to enter Menu Selection,


1 Enter ECO mode by pressing , select by , confirm by pressing
following is the figure: to open Child Lock function when is
flashing.

2 Exit ECO mode by pressing . 2 Cancel Child Mode by long pres .


4. User Option 26 5. User Options Table 27

1. You may change user operation after entered User Operation by Pressing
ID Option Content Min. Max. Default
when is flashing under Menu Selection.

1 Change 12h or 24h clock 12 24 24

Change to another pre-set


2 programme 1 3 1

3 Switch on/off summer/winter time OFF ON ON

4 Change temperature offset℃ -5 5 0

5 Restore the factory Settings OFF ON OFF


2. Under User Option, the option ID is showing on Temperature Area(screen left side), the
Option Content is shown on Time Area(screen right side). 6 To disable Off function OFF ON OFF

7 Frost Protection OFF ON ON

8 Pre-set the lowest temperature 7 32 7

9 Pre-set the highest temperature 7 32 32

10 Pre-set the ECO temperature 7 32 9

Valve Protection(unit: min., if the


3. Option ID is flashing under User Option(details to see User Options Table below), press valve has not been opened for
t o scroll through selectable options, select the target Option ID by 11 24hours, it will be automatically 0 5 0
pressing ; then, adjust the User Option by pressing and set it opened every 10:00am; “0” means
down by pressing . no Valve Protection

4. To cancel User Operation’s setting, press when Option Content flashing. OFF
Activate Smart Remote
12 Control (App remote control) OFF ON (ON for Wi-Fi
thermosta)
5. To exit User Operation’s setting, press when Option ID flashing
6. Product Specification 28 6. Product Specification 29

Wireless Programmable Thermostat Wireless Receiver

Operating Temperature 0 to 50°C Operating Temperature 0 to 50°C

Control mode Heating system 868 MHz(433 MHZ, PTR10-433),


Transmitting frequency
2 way
Display LCD with backlight
Communication Range
868 MHz(433 MHz-PTC10-433), 100 meters
(open space)
Transmitting frequency
2 way
Power 2W
Communication Range
100 meters
(open space) Power supply 100VAC~240VAC, 50Hz

Power supply 2 x AA alkaline batteries 240VAC 50Hz, 5A resistive,


Switch rating
2A inductive
Battery life Typically 2 years
Switch Type SPDT relay
Temperature setting range 7°C to 32°C (0.5°C step)
Dimensions (HxWxD) 98.3x 98.3 x 31.3mm
Temperature control accuracy +/-0.5°C
IP class IP30
Measurement interval every minute
Standard CE
Frost protection temperature 7°C
Weight 145g
Humidity range 10 to 90%RH

Humidity accuracy +/-5%RH

Time display 12 hour/24 hour

Dimensions(HxWxD) 117.2 x 87.2 x 26.6mm

IP class IP30

Standard CE

Weight 211g with battery