PY600AC Sliding Gate Opener User Manual
PY600AC Sliding Gate Opener User Manual
1. Safety Instruction
Please make sure that the power voltage being used matches with the supply voltage of gate opener
(AC110V or AC220V); kids are not allowed to touch the control devices or the remote-control unit.
The remote-control unit is single button mode or three button mode (please refer to the instructions
of the remote control in accordance with the actual gate opener type). The indicator light on the
remote-control unit will flicker when its button is pressed. Main engine and gate can be unlocked
with a disengagement wrench and the gate can be manually operated after disengagement.
Please make sure that nobody is around the main engine or gate when the switch is operated.
Please temporarily stop using the product if the main engine needs to be repaired or regulated. The
Please read this manual carefully before installing、using、maintaining or repairing it. Without
following this manual, any injury or property losses caused by improper use or unauthorized
1
2. Packing List (standard)
No. Picture Name Quantity
1 Main engine 1
A A
B B
3 C
D
C
D
Remote control 2
4-4 Nut M8 8
2
2. Packing List (optional)
No. Picture Name Quantity
3 Infrared sensor 1
1 2 3
4 5 6
4 7 8
0
9
Wireless keypad 1
5 Alarm lamp 1
6 Mounting plate 1
3. Technical parameters
Model PY600AC
Power supply 220V/50Hz;110V/60Hz
Motor power 280W
Gate moving speed 11-13m/min
3
Maximum weight of gate 600Kg
Remote control distance ≥30m
Single button mode
Remote control mode
/ Three button mode
Spring limit switch
Limit switch
Magnetic limit switch
Noise ≤58dB
Working duty S2, 15min
Recording of up remote controls 25
Frequency 433.92 MHz
Working temperature -20°C ~ +70°C
Package weight 9.4Kg
4. Installation
PY600AC sliding gate opener is applicable to gate weight less than 600kg, and length of the sliding
gate less than 12m. The drive mode adopts the rack and gear transmission. This gate opener must
be installed inside the enclosure or yard for protection.
④
③
② ⑥
1 2 3
⑦
4 5 6
7 8 9
0
⑧
①
Figure 1
① Gate opener; ② Wireless keypad (optional); ③ Gate; ④ Infrared sensor (optional);
⑤ Alarm lamp (optional); ⑥ Safety stop block; ⑦ Gear rack; ⑧ Remote control;
4
4.2 Size of main engine and accessories
4.2.1 Size of main engine
260
251 227
Figure 2 (1) Spring Limit Switch
260
251 225
5
204±0.3
150
8×Φ10
90±0.3
107
Figure 3
Cable installation
In order to guarantee the normal operation of the gate opener and protect the cables from damages,
please bury the motor & power cable and controlling cable separately with two PVC tubes.
Concrete pedestal
Please precast a concrete pedestal with the size can be 400mm x 250mm, depth be 200mm in
advance, so as to firmly install SL600AC gate opener. Please make sure the distance
between the gate and gate opener is appropriate before casting the pedestal.
Embedded screws
Mounting plate
Foundation bolt
Concrete
Power line
Figure 4
6
properly;
b) Please prepare the power line for connecting the mounting plate to the main engine (the number
of power supply cable cores should not be less than 3 PCS, the sectional area of cable core should
be over 1.5mm² and the length should be determined by users according to the situation on
installation spot.)
c) Please unlock the main engine before installation, the unlock method is: insert the key, open the
manual release bar till it rotates by 90° as shown in Figure 5. Then turn the output gear and the gear
can be rotated easily;
Turn on 90°
Figure 5
4.3.3 Gear rack installation
Fix the mounting screws to the rack.
Put the rack on the output gear, make the rack engage with the output gear then weld the
mounting screw to the gate (each screw with one solder joints firstly).
Manually move the gate (gate should be moved smoothly after motor unlocked) to check
whether there is a fit clearance between rack and output gear, as shown in Figure 7.
Weld all the mounting screws to the gate firmly.
Make sure that all racks on the same straight line.
Pull the gate after installed, make sure the entire trip is flexible without any stuck.
Figure 6
The fit clearance of output gear and rack is shown in Figure 7 below:
7
Gear rack
1-2 mm
Output gear
Figure 7
Warnings
·To ensure safety, install safety stop blocks on both ends of the rail to prevent the gate from running
out of the rail. Before installing the main engine, make sure that the safety stop blocks are in place
and whether it has the function of preventing the gate from running out of the rail or safety range.
·Please make sure that the main engine and its components have good mechanical properties, and
the gate can be operated flexibly when manually moved before installing the main engine.
·Please note that for this product, one control can only drive one main engine, otherwise, the control
system will be damaged.
·Earth leakage circuit breaker must be installed in where the gate movement can be seen, and the
minimum mounting height is 1.5m to avoid being touched by children.
·After installation, please check whether the mechanical property is good or not, whether gate
movement after manual unlocking is flexible or not, whether the installation for infrared sensor
(optional) is correct and effective.
8
Gate
Gear rack
Output gear
Figure 8
Figure 9
Magnetic limit switch - The installation position of magnetic limit switch is shown in Figure 10:
9
Gate
≤20mm
Magnets
Gear rack
Output gear
Figure 10
The installation of magnetic limit switch stop block is shown in Figure 11:
M6×18 M6×18
Figure 11
Note: The default setting is right side mounting. (According to actual situation, please refer to the
“Note” of section 4.3.5.1 and 4.3.5.2 “Adjustment and operation” to adjust.)
4.3.5 Control board wiring
4.3.5.1 Standard control board
10
Lamp Capacitor Motor Earth Power
D2 D1 C C W U V PE PE N L
X3 X2 X1
OPN
+
ON X7
AN1
LED2
Figure 12
Wiring instruction:
1. Connect L and N to the power supply of AC220V/50HZ; AC110V/60HZ; L is Live wire, N is
Neutral wire, and PE is grounding wire.
2. Connect LAMP to D1, D2; voltage: AC220V/50HZ; AC110V/60HZ.
3. Connect the motor wire U to the REV motor wire, connect W to the FWD motor wire, and
connect V to the motor common wire.
4. Connect C, C to the capacitor wire.
X5 Terminal
24VDC Power supply for fittings +24VDC(Electric current ≤50mA);
GND Power ground;
I.R Photocell input (N.C.);
CLLM Close limit switch;
COM Limit switch common terminal;
OPLM Open limit switch.
X7 Terminal
COM Control button common terminal;
STP Stop control button (N.O.);
CLS Gate close control button (N.O.);
OPN Gate open control button (N.O.).
DIP Switch
1. External button switch. ON - Three button switch; OFF - Single button switch (X7 terminal
CLS button can be used to circularly control OPEN/STOP/CLOSE/STOP of the main engine).
2. Automatic close time.
3. Automatic close time.
Setting for automatic close time:
2 ON 3 OFF: automatic close time is 15s,
11
2 OFF 3 ON: automatic close time is 30s,
2 OFF 3 OFF: automatic close time is 45s,
2 ON 3 ON: no automatic close function.
Infrared connection
Infrared photocell function: In the closing process, when infrared ray of the photocell is covered by
people or objects during its detection range, the gate will open immediately for security protection.
The distance between photocell receiver and photocell emitter should be more than 2 meters,
otherwise will affect the induction of the photocell.
If connect the infrared photocell, please remove the short connection between I.R and GND on the
X5 terminal.
PE N L
V- V+
V- V+ NO COM NC
X1
10A 250V
X5
24VDC
GND
I.R
CLLM
COM
OPLM
COM
X8
STP
CLS
OPN
X7
Figure 13
12
Adjustment and operation
Remote control operation
Three button mode remote control: OPEN/CLOSE/STOP of main engine are controlled by three
buttons separately on the remote control.
Single button mode remote control: OPEN/CLOSE/STOP of main engine are controlled by one
button circularly on the remote control.
OPEN
CLOSE
OPEN
STOP
CLOSE
A A
STOP
B B
C C
D D
Three button mode remote control Single button mode remote control
Figure 14
Add extra remote control (remote control learning): Remove the main engine housing, then take
out the upper cover of the control box, press the learning button AN1 on the control board, and
indicator light LED2 will flash. Press the button that to be learned on the remote control once, The
LED2 will be off. Press the same button on the remote control twice, the LED2 will flash several
times and be off; remote control learning complete. A maximum of 25 remote controls can be
learned.
Delete remote control: To delete remote control that have been learned: press and hold the
learning button AN1, the indicator light LED2 will be on; Then release it until LED2 is off. After the
steps, all the matched remote controls will be deleted.
Note: To disengage gate opener, move the gate to the middle position, then close the clutch and
press the open button of external button switch to open the gate. If the gate opening direction is
wrong, you can change the direction through the toggle switch SW1 on the control board or
exchange the motor phase-sequence lines U and W. If the opening or closing limit is wrong,
please exchange limit switch lines CLLM and OPLM on the control board.
13
4.3.5.2 Intelligent control board
Hall line
OFF
U1
SW1
X1
HALL
S1
7 8 9 10 11 12 13
POWER
U2
COM
LEARN
13
Close limit switch
Loop detetcor
10 11
GND
Infrared sensor
12VDC
J5
Pedestrian switch
1 2 3 4 5 6
Capacitor 5 6 O/S/C switch
MOT
CAP J6
COM
Stop control button
1 2 3
Lamp
PE PE L N
J4
Earth
Power
J3
Figure 15
Wiring instruction:
1. Connect L and N to the power supply of AC220V/50HZ; AC110V/60HZ; L is Live wire, N is
Neutral wire, and PE is grounding wire.
2. Connect LAMP to caution light; voltage: AC220V/50HZ; AC110V/60HZ.
3. Connect the motor wire MOT2 to the REV motor wire, connect MOT1 to the FWD motor wire,
and connect MOTCOM to the motor common wire.
4. Connect MOTCAP to the capacitor wire.
J2 Terminal (For the convenience of wiring, this terminal is accompanied with failure diagnosis
light)
1. Gate close control button (N.O.)
2. Gate open control button (N.O.)
3. Stop control button (N.O.)
4. Control button common terminal
5. Open/Stop/Close/Stop loop control button (N.O.)
6. Pedestrian mode control button (N.O.)
Press the button while the door is closed, it will open for 1 meter which is for pedestrian only.
J5 Terminal (For the convenience of wiring, this terminal is accompanied with failure diagnosis
14
light)
7. Power supply for fittings: +12VDC(Electric current ≤100mA);
8. Photocell input (N.C.); short out the device with terminal 9(GND) if not used.
9. GND
10. Loop detector (sensor coil) connector (N.O.)
In the closing process, once vehicles are detected by the loop detector, the gate will open
immediately; when the vehicle passes, the gate will close automatically. When the gate is in
a halted state, it will keep this state when vehicles are detected; after the vehicle passes, the
gate will close automatically.
In the above loop detector function, users can make the gate close automatically 12
seconds later after the vehicle passes. Change the No.4 key of the dip switch on circuit
board, and the gate will close automatically 12 seconds later after the vehicle passes.
11. Close limit switch
12. Limit switch and other input signal common terminal
13. Open limit switch
Function adjustment
Functional parameters of the control board equipped with microprocessor can be adjusted through
potentiometer and dip switch, so as to meet different installation requirements.
OFF
1 2 3 4 5 SPEED GND VCC
J1
SW1
X1
HALL
S1
12 13
POWER
U2
LEARN
13
Figure 16
Adjusting knob
VR1: When meet obstacle reverse function is enabled (DIP switch 5 on OFF position and the motor
assembled with the hall line). This knob is used for sensitivity adjustment of meeting obstacle.
Clockwise rotation to reduce sensitivity of obstacle, counter-clockwise rotation to increase sensitivity
of obstacle.
When meet obstacle reverse function is disabled (DIP switch 5 on ON position), this knob is used for
motor working total time adjustment. Clockwise rotation to increase, counter-clockwise rotation to
reduce. The total time can be set to 10 seconds as minimum and 90 seconds as maximum.
VR2: For brake force adjustment in limit position.
Clockwise rotation to increase, counter-clockwise rotation to reduce.
Rotate to the minimum to cancel brake function in place.
VR3: For slow stop width adjustment.
Clockwise rotation to increase, counter-clockwise rotation to reduce.
15
Rotate to the minimum to cancel the slow stop function.
VR4: For motor output force adjustment to ensure safety.
Clockwise rotation to increase, counter-clockwise rotation to reduce.
Note: The default setting is VR1, VR2, VR3, VR4 are the maximum value, and the user can adjust
according to the actual requirement.
Warning: The motor output force cannot set too large, just to be able to drive the gate.
Dip switch
1. Soft start function. OFF - enabled; ON - disabled.
2. Limit switch setting. OFF- normal open (N.O.); ON - normal close (N.C.).
3. Automatic close time.
4. Automatic close time.
Setting for automatic close time:
3 OFF 4 ON: automatic close time is 12s,
3 ON 4 OFF: automatic close time is 24s,
3 ON 4 ON: automatic close time is 36s,
3 OFF 4 OFF: no automatic close function.
5. Meet obstacle reversal function. OFF - enabled; ON - disabled.
Infrared connection
Infrared photocell function: In the closing process, when infrared ray of the photocell is covered by
people or objects during its detection range, the gate will open immediately for security protection.
The distance between photocell receiver and photocell emitter should be more than 2 meters,
otherwise will affect the induction of the photocell.
If connect the infrared photocell, please remove the short connection between 8 and 9 on the J5
terminal.
OFF
U1
J1
SPEED GND VCC
SW1
X1
V- V+
HALL
S1
V- V+ NO COM NC
7 8 9 10 11 12 13
U2
POWER
13
LEARN
10 11
8
J5
Figure 17
16
Adjustment and operation
Remote control operation
Three button mode remote control: OPEN/CLOSE/STOP of main engine are controlled by three
buttons separately on the remote control.
Single button mode remote control: OPEN/CLOSE/STOP of main engine are controlled by one
button circularly on the remote control.
OPEN
CLOSE
OPEN
STOP
CLOSE
A A
STOP
B B
Pedestrian mode Pedestrian mode
C C
D D
Figure 18
Add extra remote control (remote control learning): emove the main engine housing, then take
out the upper cover of the control box, press and hold the learning button S1 for 2 seconds, then the
indicator light LEARN will be on; press the button that to be learned on the remote control twice, the
LEARN will flash several times and be off; remote control learning complete. A maximum of 40
remote controls can be learned.
Delete remote control: To delete remote control that have been learned; press and hold the
learning button S1, the indicator light LEARN will be on; Then release it until LEARN is off. After the
steps, all the matched remote controls will be deleted.
The fourth button on the remote control is for pedestrian mode, press the button while the door is
closed, it will open for 1 meter which is for pedestrian only.
Note: To disengage gate opener, move the gate to the middle position, then close the clutch and
press the open button of external button switch to open the gate. If the gate opening direction is
wrong, you can exchange the motor phase-sequence lines MOT2 and MOT1. If the opening or
closing limit is wrong, please exchange limit switch lines which are connected to the
corresponding terminal 11 and 13 on the control board.
5. Others
5.1 Maintenance
Check whether the gate operates normally every month.
For the sake of safety, each gate is suggested to be equipped with infrared protector, and regular
inspection is required.
Before installation and operation of the gate opener, please read all instructions carefully.
17
Our company reverses the right to change the instruction without prior notice.
5.2 Troubleshooting
18
Power supply line short circuit or
Leakage switch tripped. Check wiring.
motor line short circuit.
Connect external receiver
Remote control working
Signal is blocked. antenna, 1.5 meters above
distance is too short.
ground.
1.Motor output force is not enough
The gate moves to the (Intelligent type). 1.Adjust the VR4.
middle position to stop 2.Sensitivity of obstacle is too 2.Adjust the VR1.
or reverse. big(Intelligent type). 3.Remove the obstacle.
3.Gate meets obstacle.
Automatic close function has been Please refer to the attentions
Gate opens
turned on but with incorrect under 4.3.5.1 and 4.3.5.2 to
automatically
opening direction. change the opening direction.
Warranty
Warranty Ordinance
1. To repair against this warranty card and invoice during the warranty period.
2. Warranty period: 1 year after the date of invoice.
3. Without unauthorized dismantling, any product broken or damage due to quality problem, we’ll
offer the repair service for free or replace for free.
4. The malfunction and damaged caused by incorrect use or man fault is not covered by this
warranty.
Maintenance Record
2018V1
19