7PA22/23/26/27/30 Auxiliary Relays For Various Applications: Technical Data

This document provides technical specifications for Siemens auxiliary relays and a fast-acting lockout relay. The auxiliary relays have continuous current ratings of 10A, can withstand overloads of 80A/200ms or 150A/10ms, and have switching capacity ratings up to 40A at 110V DC. The fast-acting lockout relay has 8 changeover contacts, operates in under 10ms, and provides position indication and mechanical reset. Both relays meet various industry standards and are suitable for applications requiring high reliability such as power facilities.

Uploaded by

soltani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
618 views7 pages

7PA22/23/26/27/30 Auxiliary Relays For Various Applications: Technical Data

This document provides technical specifications for Siemens auxiliary relays and a fast-acting lockout relay. The auxiliary relays have continuous current ratings of 10A, can withstand overloads of 80A/200ms or 150A/10ms, and have switching capacity ratings up to 40A at 110V DC. The fast-acting lockout relay has 8 changeover contacts, operates in under 10ms, and provides position indication and mechanical reset. Both relays meet various industry standards and are suitable for applications requiring high reliability such as power facilities.

Uploaded by

soltani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

15 Test Equipment and Accessories / 7PA

7PA22/23/26/27/30
Auxiliary Relays for Various Applications
Technical data

Switching contacts
Continuous current 10 A
Overload capability 80 A/200 ms
150 A/10 ms
Switching current/voltage 40 A/0.5 s/110 V DC
Breaking capacity for 105 operating cycles
Non-inductive Inductive, 20 ms
1 contact 2 contacts 1 contact 2 contacts
in series in series
V DC A A A A
24 6.6 12.7 3.2 6.0
60 2.6 4.9 1.4 2.7
125 1.2 2.2 0.6 1.1

LSP2457-afp.tif
220 0.6 1.1 0.3 0.6

For details see characteristics


Vmax, open contact 250 V DC/400 V AC
Mechanical service life 107 operating cycles
Operating temperature - 10 °C to + 70 °C
Fig. 15/2 7PA2 auxiliary relays 14 °F to 158 °F
Max. permissible humidity 93 % at 40 °C/104 °F
Seismic stress class according to IEEE 501
Degree of ZPA 3 g acceleration at
Description 33 Hz

Due to their quality, reliability and design,


these relays are optimal for applications re-
quiring high reliability and availability
such as power stations, substations, railway
and industrial plants. Typical examples in-
clude petrochemical industry, chemical in-
dustry, cement industry, rolling mills etc.
The relays comply with the IEC, EN, IEEE
standards (type and routine test) and bear
the CE mark.
The robust switch contacts are character-
Standards
ized by high make/break capacity, overload
capability and continuous current intensity Electrical tests performed according to IEC 60255
- Insulation 2 kV/50 Hz/ 1 min
capacity; thus perfect insulation is obtain- - Impulse withstand 5 kV/1.2/50 µs
ed. Direct control of high-voltage and me- strength
dium-voltage switchgear is possible. - Dielectric strength > 2000 MΩ/
500 Vpeak-to-peak
Their high degree of protection and the Flammability tests according to IEC 60692-2-1
transparent cover ensure reliable operation Plastic materials UL 94: VO,
in tropical and/or salty sea air ambient IEC 60695: 850 °C/30 s
conditions. 1562 °F/30 s
Degree of protection Relay: IP 40
acc. to IEC 60529 With socket cover:
IP 50
Climatic stress test according to
- IEC 60255-7 Non-dissipating unit
dry heat +70 °C/96 h 158 °F/96 h
Dissipating unit
+55 °C/96 h 131 °F/96 h
- IEC 60068-2-30 +55 °C/12 h 15
cyclic humid heat 131 °F/12 h
- IEC 60068-2-1 100 cycles
cold Non-dissipating unit
-10 °C/2 h 14 °F/2 h
- IEC 60255-7 At rated voltage VN
thermal aging test +55 °C/1440 h
131 °F/1440 h

Siemens SIP · 2004 15/5


15 Test Equipment and Accessories / 7PA

Technical data
7PA22
While the auxiliary voltage is being sup-
Fast-acting lockout relay plied to the SET coil, the reset pushbutton
Description must not remain pushed longer than 20 s.

The bistable 7PA22 is a fast-acting lockout Rated voltages and consumption


relay with eight changeover contacts and is VN Voltage range Consumption
plugged into a mounting frame equipped while switching
with a plug-in socket (type 7XP9010) with V DC V DC
screw-type terminals at the rear. 24 19 - 26
30 24 - 33
Functions
60 48 - 66 ≤ 48 W
No continuous power consumption. Posi-
110 88 - 121
tion indication on the front side. Mechani-
cal reset pushbutton. 125 100 - 137
Position memory with two positions ( e.g. 220 176 - 242
for yes/no, open/close, auto/manual, lo-
cal/remote etc.). • Pick-up time: < 10 ms
Fig. 15/3 Connection diagram
General description see page 15/5. Contacts represented in position RESET
Refer to part 16 for dimension drawings.

Selection and ordering data Description Order No.


7PA22 fast-acting lockout relay 7PA22o1-o

Auxiliary voltage
24 V DC 1
60 V DC 2
110 V DC 3
220 V DC 4
125 V DC 5
30 V DC 6

Socket
without socket 0
with flush-mounting socket 7XP9010-1 1

Accessories Description Order No.


Socket as spare part
Flush mounting 7XP9010-1
Surface mounting 7XP9012-0

15

15/6 Siemens SIP · 2004


15 Test Equipment and Accessories / 7PA

Protection functions Technical data


While the auxiliary voltage is being sup-
7PA23 plied to the SET coil, the reset pushbutton
must not remain pushed longer than 20 s.
Fast-acting lockout relay Rated voltages and consumption
Description VN Voltage range Consumption
while switching
The bistable 7PA23 is a fast-acting lockout
relay with four changeover contacts and is V DC V DC
plugged into a mounting frame equipped 24 19 - 26
with a plug-in socket (type 7XP9011) with 30 24 - 33
screw-type terminals at the rear.
60 48 - 66 ≤ 24 W

Functions 110 88 - 121


125 100 - 137 Fig. 15/4 Connection diagram
No continuous power consumption. Posi-
tion indication on the front side. Mechani- 220 176 - 242 Contacts represented in position RESET
cal reset pushbutton. • Pick-up time: < 8 ms
Position memory with two positions General description see page 15/5.
(e.g. for yes/no, open/close, auto/manual, Refer to part 16 for dimension drawings.
local/remote etc.).

Selection and ordering data Description Order No.


7PA23 fast-acting lockout relay 7PA23o1-o

Auxiliary voltage
24 V DC 1
60 V DC 2
110 V DC 3
220 V DC 4
125 V DC 5
30 V DC 6

Socket
without socket 0
with flush-mounting socket 7XP9011-1 1

Accessories Description Order No.


Socket as spare part
Flush mounting 7XP9011-1
Surface mounting 7XP9013-0

15

Siemens SIP · 2004 15/7


15 Test Equipment and Accessories / 7PA

7PA26 Monostable relay Technical data


Rated voltages and consumption
Description
VN Voltage Consumption
The monostable 7PA26 has eight change- range
over contacts and is plugged into a mount- V DC V DC
ing frame equipped with a plug-in socket
24/30 19 - 33 7PA26o1: ≤ 6 W
(type 7XP9010) with screw-type terminals Peak: ≤ 45 W
at the rear. 60 48 - 66
7PA26o0: ≤ 5 W
110/125 88 - 137
220 176 - 242

• Pick-up time: 7PA26o0 < 20 ms


7PA26o1 < 10 ms
• Drop-out time: < 40 ms
General description see page 15/5.
Refer to part 16 for dimension drawings.

Fig. 15/5 Connection diagram

Selection and ordering data Description Order No.


7PA26 monostable relay 7PA26oo-o

Auxiliary voltage
24 /30 V DC 1
60 V DC 2
110/125 V DC 3
220 V DC 4

Standard, 20 ms 0
Fast, 10 ms 1

Socket
without socket 0
with flush-mounting socket 7XP9010-0 1

Accessories Description Order No.


Socket as spare part
Flush mounting 7XP9010-0
Surface mounting 7XP9012-0

15

15/8 Siemens SIP · 2004


15 Test Equipment and Accessories / 7PA

Technical data
7PA27 Monostable relay
Rated voltages and consumption
Description
VN Voltage Consumption
The monostable 7PA27 is a fast-acting relay range
with four changeover contacts and is V DC V DC
plugged into a mounting frame equipped
24/30 19 - 33 ≤ 3.5 W
with a plug-in socket (type 7XP9011) with Peak: ≤ 25 W
screw-type terminals at the rear. 60 48 - 66
110/125 88 - 137
220 176 - 242

• Pick-up time: < 8 ms


• Drop-out time: < 40 ms
Fig. 15/6 Connection diagram
General description see page 15/5.
Refer to part 16 for dimension drawings.

Selection and ordering data Description Order No.


7PA27 monostable fast-acting relay 7PA27o0 -o

Auxiliary voltage
24 /30 V DC 1
60 V DC 2
110/125 V DC 3
220 V DC 4

Socket
without socket 0
with flush-mounting socket 7XP9011-0 1

Accessories Description Order No.


Socket as spare part
Flush mounting 7XP9011-0
Surface mounting 7XP9013-0

15

Siemens SIP · 2004 15/9


15 Test Equipment and Accessories / 7PA

7PA30
Trip circuit supervision
Description
The 7PA30 relay is equipped with green
LED and two changeover contacts. It is ap-
plied for trip circuit supervision in the open
and close position of the circuit-breaker. It
monitors the trip circuit, the trip coil and
the proper state of the fuses and mini cir-
cuit-breakers of the circuit.

Functions
The 7PA30 indicates a trip circuit failure
with a time delay of 150 ms.
The relay is always in an energized condi-
tion, regardless of the position of the cir-
cuit-breaker (open/close).
In the event of actuation of the relay, its
unassigned contacts can be used for:
– Blocking the circuit-breaker connection
– Issuing the trip command to another
c.-b. upstream or to a second trip coil of Fig. 15/7 Connection diagram
the same c.-b. Switching contacts shown without
– Local or remote signaling auxiliary power supply in the relay

Under normal operating conditions, the


7PA30 cannot issue spurious tripping be- Technical data Rated voltages and consumption
cause of the large resistance of its coil. In
the event of a short-circuit of the coil, the 7PA30 relays are applied only for trip cir- VN Voltage range Consumption
LED would melt and thus prevent un- cuits with a power consumption of > 30 W.
wanted operation of the circuit-breaker. V DC V DC
24 19 - 26
30 24 - 33
60 48 - 66 ≤ 2.4 W
110/125 88 - 137
220 176 - 242
General description see page 15/5.
Refer to part 16 for dimension drawings. • Drop-out time: < 18 ms

Selection and ordering data Description Order No.


7PA30 trip circuit supervision 7PA30o0-o

Auxiliary voltage
24 V DC 1
60 V DC 2
110 / 125 V DC 3
220 V DC 4
30 V DC 6

Socket
15 without socket 0
with flush-mounting socket 7XP9011-0 1

Accessories Description Order No.


Socket as spare part
Flush mounting 7XP9011-0
Surface mounting 7XP9013-0

15/10 Siemens SIP · 2004


15 Test Equipment and Accessories / 7PA

Dimension drawings in mm / inch

Fig. 16/55 Fig. 16/56


7PA22, 7PA26 auxiliary relays 7PA23/27 auxiliary relay
7TS15 indication relay 7PA 30 trip circuit supervision

Fig. 16/57 Fig. 16/58


Flush mounting socket 7XP9010 Flush mounting socket 7XP9011
for 7PA22, 7PA26 auxiliary relays for 7PA23/27 auxiliary relay
7TS15 indication relay 7PA30 trip circuit supervision

Fig. 16/59 Fig. 16/60


7PA22, 7PA26 auxiliary relays Surface mounting socket 7XP9013
7TS15 indication relay for 7PA23/27 auxiliary relay
7PA30 trip circuit supervision
15