Gcs - Gecb: Reference List
Gcs - Gecb: Reference List
: GAA30780DAK_REF
Software Basic Data
OTIS SCN: GAA30780DAK
GCS - GECB
Reference List
Revision History
Date Rev Author Comment
2004-08-26 G1530780AAA A. Pfeffer first document based on TCBC Software
GAA30084AAF
2005-01-27 G2130780AAA H.-K. Spielbauer Number update only prior shipping
2005-03-03 G2230780AAA A. Pfeffer conditions for EFO inputs added
2005-03-29 G2430780AAA A. Pfeffer blink messages "DOL alw. on", "No 110VAC",
"OmuPresent" added
Event "0307 RDOL alw.on" added
2005-04-06 GAA30780AAA A. Pfeffer Release
2005-07-21 GAA30780AAB A. Pfeffer HPB added for Compass
2005-10-25 GAA30780AAC A. Pfeffer no changes
2006-10-26 B. Braasch Op. Mode: CBP; EAR; added
Mo. State: SD->SR; renamed., ES; EF; EW;
RL; added
Mo.Command: Relevel; added
System inputs: GDS; L30; L50; GSM; DHB;
SDB; ^GSM; ^DHB; ^SDB; ADB; EDB;1EF;
2EF; DDS; DES; EQ1; EQ2; EQ3; EQW;EQR;
ISP; FAN; ^FAN; CTC; CTO; PKG; CFB; IST;
ROT; ACC; ACH; GSI; HCH; GCO; CHC;
GCB; ^GCB; LDS; MAS; HCR; ATK; ^RB;
GRT; DPC; UPC; DUP; SRO; AD1; AD2; AD3;
BPZ; ELZ; GFB; WCO; SG1-SG7; CS1-CS6;
CSC; CSK; GSK; CLR; DFO; ^DFO; LEV;
DCD; CCB; CCT; PC1-PC8; SHC SHT; AMC;
LPT; SMB; added
System outputs: UD; added
Blink message: MRO active; added
Event logging: 16; 17; 19; 109; 110; 213-217;
224; 225; 308-315; 319; 505-507; 604; 605;
added
Table of Contents
1 Operational Modes...........................................................................5
2 Motion States ...................................................................................7
3 System Inputs...................................................................................8
4 System Outputs..............................................................................13
5 Info Messages ................................................................................14
6 Blinking Event Messages ..............................................................15
7 Event Logging ................................................................................19
8 Diagnostic Parameters ..................................................................30
9 Commands .....................................................................................31
No.: GAA30780DAK_REF
Software Basic Data
OTIS SCN: GAA30780DAK
1 Operational Modes
2 Motion States
3 System Inputs
The following list shows all available inputs and the condition under which these inputs are
displayed (set DISP-ALL=1 to view all available inputs).
^WDO rear Wheel Chair Door Open Button IO1170 RWDOB programmed
^WDC rear Wheel Chair Door Close Button IO1171 RWDCB programmed
DCD Russian Code Disable Call and Door switch IO0786 DCDS programmed
CCB Car Call to Bottom landing IO0786 DCDS programmed
CCT Car Call to Top landing IO0786 DCDS programmed
4 System Outputs
NUD Emergency
NUG
5 Info Messages
The following messages are accessible in the Main Menu GECB – Menu.
Please use Shift Key UP.
# RSL’s: 1 > Number of RSL links. “3” is displayed if the GECB-IO board
3 > physically supports 3 links and the parameter RSL-TYP=1 is
set. Otherwise “1” is displayed.
Board: GECBI > Type of GECB IO Board.
GECBII >
No.: GAA30780DAK_REF
Software Basic Data
OTIS SCN: GAA30780DAK
The following messages are blinking in each status display of the Service Tool:
Note:
This message has been renamed in AAE.
LBG/CSP-2 Light Beam Gate has been active. LBG
(967, 968)
No.: GAA30780DAK_REF
Software Basic Data
OTIS SCN: GAA30780DAK
7 Event Logging
The table below lists all possible event logging messages of the Service Tool. The events
are devided into the following classes:
I Info
W Warning
F Fault
Operating System
0000 Task Timing W Dummy task has not been called within -
timeout. Software has been restarted.
0001 S/W Reset W watchdog circuit on GECB was triggered. -
Software has been restarted.
0002 Illegal Int W illegal interupt was executed -
0003 CcanTxFull W Car bus CAN messages cannot be sent -
0004 CcanBusOff F Car bus CAN communication failure -
0006 StackCheck F Stack Violation was detected. Software -
has been restarted.
0007 SCN Error F Wrong Software. -
Æ order a new software with correct part-
number.
0008 TimerSync F Internal software timers have not been -
updated correctly. Software has been
restarted.
0009 Task Fail F Application software doesn’t run properly. -
Software has been restarted.
0010 McbCommErr F No CAN connection to the drive -
0011 SpbCommErr W No CAN connection to the SPB -
0012 Power On I Board has been powered on. -
0013 Event Fail W -
0014 PowerOffOn I Short Failure of PowerSupply. -
0016 S/W Restart W Reset with unknown reason -
0017 Trace Error F bad value in the eventTraceControl buffer -
0018 Bad E2P W Different addresses found for “mirrored I/O
I/Os” (e.g. IO0032 and IO3000)
Æ Check all level- and opening-related
I/Os
0019 MissedLvInt F lv1 and lv2 edge was missed -
0020 RemoteReset I System was reset by Elite Service expert -
No.: GAA30780DAK_REF
Software Basic Data
OTIS SCN: GAA30780DAK
Group
0500 RNG1 msg W data error on Duplex/Triplex ring -
0501 RNG1 time W no ring messages received from other car GROUP
for a specific time
0502 RNG1 sio W framing error on Duplex/Triplex ring -
0503 RNG1 tx W ring messages couldn't be sent in an ap- -
propriate time
0504 RNG1 rxOff W No messages are received within a time- -
out, and NO BREAK is detected.
0505 RNG1 reset W Reinitializing RING Service (stm_ring_run -
expired)
0506 DES offline F DES is not present -
0507 GCB offline F no GCB is present -
0508 GCB fail F For Compass, the primary GCB has failed -
and the secondary GCB is used.
Æ Check GCB boards
No.: GAA30780DAK_REF
Software Basic Data
OTIS SCN: GAA30780DAK
System
0600 SPB-Alert W The Service Panel Board detected a mal- -
function which hinders a manual rescue
operation with SPB and SDI. Possible rea-
sons are:
- defective speed encoders for SDI
- defective E2PROM on SPB
- Missing battery for SPB
Press the SPB-buttons REB + DDO simul-
taneously to locate the error.
0601 SPB:TempHTS W The Service Panel Board detected an SPB-Temp
overtemperature.
0602 LwssService W The LWSS requested “Request For Ser- -
vice” (REM). See LWSS event logging for
reason.
0604 S/W Changed I Informational event that new software was -
installed. The events are automatically
cleared. No action necessary.
0605 Update S/W! W New subsytem software was installed that -
requires new GECB software.
0606 SpbService W The SPB requested “Request For Service” -
(REM). See SPB event logging for reason.
0607 /TUM1 F TUM1 missing after run at TOP or active TUM1 (1047)
during standstill; (reduced overhead: trig- HWY-TYP
ger modul contacts)
0608 /TUM2 F TUM2 missing after run at TOP or active TUM2 (1048)
during standstill; (reduced overhead: trig- HWY-TYP
ger modul contacts)
0609 /TDM F TDM missing after run at BOTTOM or ac- TDM (1049)
tive during standstill; (shallow pit: trigger HWY-TYP
modul contacts)
0610 /TUPS F TUPS missing during run; (reduced over- TUPS (1050)
head: trigger modul power supply) HWY-TYP
0611 /TDPS F TDPS missing during run; (shallow pit: TDPS (1051)
trigger modul power supply) HWY-TYP
0612 SOS up F Safety Operated Switch Up triggered SOSU (1054)
HWY-TYP
0613 SOS down F Safety Operated Switch Down triggered SOSD (1055)
HWY-TYP
0614 PRBB BatLow W The battery of the PRBB board is weak: EN-PRBB=1
During PowerOff, the battery only provides
power for less than 10 seconds.
No.: GAA30780DAK_REF
Software Basic Data
OTIS SCN: GAA30780DAK
Rescue
0701 SP missing F Node Guarding does not detect the SP at -
the CAN bus.
Check CAN_OK LED at SP; Check CAN
wiring between GECB & SP;
0702 BCB missing F Node Guarding does not detect the BCB at -
the CAN bus.
Check CAN_OK LED at BCB_II; Check
CAN wiring between GECB & BCB_II;
0703 BcbIoFail F The state of inputs were not received every -
second or the output command were not
acknowledged.
CAN bus overload? Defect BCB_II?
0704 BcbHwFail F The BCB published an EEPROM error. -
Exchange BCB_II;
0705 BcbSwFail F The BCB published a task timing problem. -
Exchange BCB_II;
0706 EncoderFail F The rescue encoder generates no signals -
during a normal run.
Check rescue encoder wiring; Replace
rescue encoder or GECB_II;
0707 OCB fail F The OCB auxiliary contacts are wired in- -
correctly.
Check wiring to OCB; Check OCB; Check
GECB_II inputs;
0708 Overspeed W The measured rescue encoder speed is SPEED / En-
15% faster than the nominal speed. The coder
OS contact or the safeties could be acti-
vated. MRO is prevented.
Reset OS contact; Check Encoder / Speed
parameter;
0710 No Battery F The BCB misses the rescue battery. -
Check RPS / battery;
0711 BatTempErr W The BCB indicates that the battery cannot -
be charged, because the temperature is
out of range.
Check battery temperature sensor;
0712 BatFault F The BCB indicates a battery charge failure -
or a defect battery.
Replace battery;
No.: GAA30780DAK_REF
Software Basic Data
OTIS SCN: GAA30780DAK
8 Diagnostic Parameters
These diagnosis parameters are stored in non-volatile memory and are kept even if the
power is switched off. They can only be reset manually via Service Tool, except ACT-T and
REC-OK which are refreshed after each power-on.
9 Commands
These internal commands are used for the on-board DCSS and MCSS.
Type Display Description
Door Commands OPEN open door
DEEN deenergize door
CLD1 close door; no DOB, no LRD, no EDP
CLD2 close door; full DOB, full LRD, full EDP
CLD3 close door; full DOB, full LRD, lim EDP
CLD4 close door; full DOB, lim LRD, lim EDP
CLD5 close door; full DOB, no LRD, no EDP
CLD6 close door; full DOB, no LRD, lim EDP
CLD7 close door; lim DOB, no LRD, lim EDP
CLD8 close door; lim DOB, no LRD, no EDP
CLD9 close door; full SGS, nothing else