0% found this document useful (0 votes)
54 views2 pages

EEN 350 Spring 2019 Formula Sheet Last Part

The document provides formulas for calculating various electrical machine parameters and performance metrics. It includes formulas for calculating the Thevenin equivalent parameters, rotor-induced torque, slip at maximum torque, and maximum torque for induction machines. It also includes formulas for no-load and locked-rotor test analysis, as well as formulas relating to DC machine internal voltage, torque, and operating characteristics for shunt, series, and separately excited DC machines.

Uploaded by

Mario Arja
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
54 views2 pages

EEN 350 Spring 2019 Formula Sheet Last Part

The document provides formulas for calculating various electrical machine parameters and performance metrics. It includes formulas for calculating the Thevenin equivalent parameters, rotor-induced torque, slip at maximum torque, and maximum torque for induction machines. It also includes formulas for no-load and locked-rotor test analysis, as well as formulas relating to DC machine internal voltage, torque, and operating characteristics for shunt, series, and separately excited DC machines.

Uploaded by

Mario Arja
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

EEN 350, Formula Sheet Last Part

Thevenin equivalent parameters


XM
VTH = V
R12 + ( X 1 + X M ) 2
2
 XM 
RTH  R1  
 X1 + X M 
X TH  X1
Rotor-induced torque
2
3VTH R2 / s
 ind =
sync[( RTH + R2 / s) 2 + ( X TH + X 2 ) 2 ]
Slip at maximum torque
R2
smax =
2
RTH + ( X TH + X 2 ) 2
Expression of maximum torque
2
3VTH
 max =
2sync( RTH + RTH
2
+ ( X TH + X 2 ) 2 )

Figure 6.34 Table of NEMA starting code letters for cage motors.

No-load test
V
| Zeq ,nl |=  X1 + X M
I1,nl

Locked-rotor test
RLR = R1 + R2
f
 = X1 + X 2
X LR = rated X LR
f test

Textbook: Electric Machinery Fundamentals, 5th Edition, S. Chapman


1
EEN 350, Formula Sheet Last Part

Figure 6.56 Rules of thumb for dividing rotor and stator circuit reactance.

Chapter 7: DC Machinery Fundamentals


For m-plex lap winding
yc =  m
a = mP
For simplex wave winding
2(C  1)
yc =
P
a=2
For m-plex wave winding
a = 2m
Internal generated voltage in a dc machine
 ZP  2 rlB 
E A =   m = K  
 2 a  P 
Induced torque
 ind = K I A

Chapter 8: DC Motors and Generators


Shunt or Separately Excited DC Motor
V R
m = T − A 2  ind
K ( K )
F
I F* = I F − AR
NF
E A nm
=
E A0 n0

Series DC Motor
V 1 R + RS
m = T − A
Kc  ind Kc

Separately Excited DC Generator


VT = E A − I A RA
Textbook: Electric Machinery Fundamentals, 5th Edition, S. Chapman
2

You might also like