SIRA BHsT
Engineering
GREAT Solutions
HP Turbine Bypass Valve
SIRA BHsT
SIRA BHsT
A high pressure turbine bypass valve is used to divert some or all of
the steam flowing from the main boiler away from the turbine and
into the cold reheater line. The valve reduces both the pressure and Pinpoint positioning
temperature so the steam can be safely transferred between these accuracy
two systems.
Key features
> Low noise levels due to multiple controlled > Optimised valve body design to minimise
throttle stages thermal stresses in case of load changes
> Optimised design of the steam atomising > Modular design of the valve to meet
nozzle, therefore: customer specifications and requirements
- Optimum homologation of water
> Inlet, outlet and spray water connections
and steam.
to match the dimensions and material of
- High steam velocities inside the nozzle
the pipework
for excellent water.
- Reduced evaporation lengths. > Type test approval certification; BKZ 1011
> Pinpoint positioning accuracy for stringent > Easy maintenance and long life
control requirements
Benefits
The pressure reduction in the SIRA BHsT > The steam atomising nozzle is centrally
valve is accomplished using multiple arranged in the valve outlet and the nozzle
controlled and uncontrolled pressure can easily be removed for maintenance
reducing stages. The plug accurately
> The steam atomising injection is designed
regulates the flow of steam through the
to reduce the size of the water droplets.
valve. When the valve initially opens, some
This increases their surface area Excellent spray
of the steam is also diverted through an
improving vaporisation and ultimately
integral pipe to the steam atomising injection
reduces the overall time to reach the water atomisation
nozzle.
target temperature
> The multiple stages prevent excessive
> The hydraulic actuator with integral
noise generation during operation and
instrumentation components provides
reduces the pressure drop across the
powerful, accurate positioning, control
valve thus ensuring maximum efficiency of
and feedback
the entire plant
> The valve seat is integrated in the body
and hard faced for added durability and a
long, trouble free life
Application
Primarily, the valve is used during the If the installed valves are sized to 100% of The trip signal is generated by a triple
start-up and shut down operations of the boiler maximum continuous rating and redundant safety cabinet. The entire system
conventional power plants. The quick they are equipped with the safety control then meets the stringent DIN EN ISO 4126
opening function allows the steam to be block mounted on the hydraulic actuators, – part 5 standards (formerly known as TRD
quickly diverted away from the turbine when the valves can also serve as an over 421) as a controlled safety pressure relief
load changes occur and/or the turbine trips. pressure safety relief system for the system (CSPRS).
main boiler.
Technical details
Body style Plug Seat tightness
Angle type, stem/actuator vertical Parabolic plug DIN 60534-4 part 3 - Leakage class V
ASME B 16-104 - class V
Operating limits Bonnet ANSI FCI 70-2 - class V
Temperature up to 650ºC Self-sealing bonnet
Inlet pressures up to 320 bar[a] Options
Actuator Additional T-piece at the valve inlet
Interfaces Double acting hydraulic actuator with SIL III certified system (IEC EN 61511) in
Butt-weld ends according to the opening helical spring (single-acting conjunction with MT 5356
customer’s specification controlled)
Product breakdown
Typical materials
Materials EN ASTM
1.7335 SA 182 Gr. F12
1.7383 SA 182 Gr. F22
1.4903 SA 182 Gr. F91
1.4901 SA 182 Gr. F92
Hydraulic actuator
Terminal box
Control block
Stroke indicator
Stem
Coupling with Limit switch
anti-twist device
Yoke
Injection
Stem rod
Throttle stages Steam atomising nozzle
Body
IMI Bopp and Reuther
Carl-Reuther-Straße 1
68305 Mannheim
Germany
Tel: +49 (0) 621 76220 - 0
Fax: +49 (0) 621 76220 - 400
[email protected]
IMI Critical Engineering
Lakeside, Solihull Parkway
Birmingham Business Park
Birmingham B37 7XZ
United Kingdom
Tel: +44 (0)121 717 3700
Fax: +44 (0)121 717 3701
www.imi-critical.com