0% found this document useful (0 votes)
32 views1 page

Existing Condition

Condition of Buulding

Uploaded by

Syed Arsalan Ali
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
32 views1 page

Existing Condition

Condition of Buulding

Uploaded by

Syed Arsalan Ali
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

PAGE NO. 1 STAAD SPACE -- PAGE NO.

39. ISOTROPIC STEEL


40. E 2.05E+008
**************************************************** 41. POISSON 0.3
* * 42. DENSITY 76.8195
* STAAD.Pro V8i SELECTseries6 * 43. ALPHA 1.2E-005
* Version 20.07.11.33 * 44. DAMP 0.03
* Proprietary Program of * 45. TYPE STEEL
* Bentley Systems, Inc. * 46. STRENGTH FY 253200 FU 407800 RY 1.5 RT 1.2
* Date= AUG 26, 2021 * 47. END DEFINE MATERIAL
* Time= 15:56:59 * 48. CONSTANTS
* * 49. MATERIAL DUMMY MEMB 15 TO 20
* USER ID: * 50. MATERIAL CONCRETE MEMB 1 TO 14
**************************************************** 51. MATERIAL STEEL MEMB 21 22
52. MEMBER PROPERTY AMERICAN
53. 1 TO 9 PRIS YD 0.7 ZD 0.32
54. 11 TO 14 PRIS YD 0.3 ZD 0.3
1. STAAD SPACE 55. MEMBER PROPERTY AMERICAN
INPUT FILE: G:\HUAWEI WORKS\G1 Philippines\14) VNZ004\Staad 56. 10 PRIS YD 0.6 ZD 0.24
Models\VNZ004_Proposed_Condition.STD 57. MEMBER PROPERTY AMERICAN
2. START JOB INFORMATION 58. 18 TO 20 PRIS AX 0.0025 IX 0.008 IY 0.005 IZ 0.005
3. ENGINEER DATE 10-JUN-21 59. 21 22 TABLE ST W24X146
4. END JOB INFORMATION 60. MEMBER CRACKED
5. INPUT WIDTH 79 61. 11 TO 14 REDUCTION RIY 0.700000 RIZ 0.700000
6. UNIT METER KN 62. 1 TO 10 REDUCTION RIY 0.350000 RIZ 0.350000
7. JOINT COORDINATES 63. SUPPORTS
8. 1 0 0 0; 2 5.8 0 0; 3 0 0 6.9; 4 5.8 0 6.9; 5 0 0 3.61; 6 5.8 0 3.61 64. 9 TO 12 FIXED
9. 7 2.9 0 0; 8 2.9 0 3.61; 9 0 -2.9 0; 10 5.8 -2.9 0; 11 0 -2.9 6.9 65. MEMBER RELEASE
10. 12 5.8 -2.9 6.9; 13 0 0.76 0; 14 5.8 0.76 0; 15 0 0.76 6.9 66. 7 10 START MY MZ
11. MEMBER INCIDENCES 67. 9 10 END MY MZ
12. 1 1 7; 2 1 5; 3 3 4; 4 2 6; 5 5 3; 6 6 4; 7 5 8; 8 7 2; 9 8 6; 10 7 8; 11 1 9 68. 22 START MP 0.99999
13. 12 2 10; 13 3 11; 14 4 12; 18 13 1; 19 14 2; 20 15 3; 21 13 14; 22 13 15 69. 21 22 END MP 0.99999
14. ELEMENT INCIDENCES SHELL 70. 21 START FZ MX MY
15. 15 1 7 8 5; 16 7 2 6 8; 17 5 6 4 3 71. LOAD 1 LOADTYPE DEAD TITLE DEAD
16. START GROUP DEFINITION 72. SELFWEIGHT Y -1.05
17. FLOOR 73. *WATER TANK LOAD 14.80 KPA IS DISTRIBUTED ON BEAMS 1 7 12
18. _FLOOR 1 TO 10 74. FLOOR LOAD
19. END GROUP DEFINITION 75. _FLOOR FLOAD -5.264 GY
20. ELEMENT PROPERTY **NOTE** about Floor/OneWay Loads/Weights.
21. 15 TO 17 THICKNESS 0.2 Please note that depending on the shape of the floor you may
22. DEFINE MATERIAL START have to break up the FLOOR/ONEWAY LOAD into multiple commands.
23. ISOTROPIC DUMMY For details please refer to Technical Reference Manual
24. E 2.17185E+007 Section 5.32.4.2 Note d and/or "5.32.4.3 Note f.
25. POISSON 0.17
26. DENSITY 0 76. MEMBER LOAD
27. ALPHA 1E-005 77. 1 TO 6 8 UNI GY -5.694
28. DAMP 0.05 78. 3 UNI GY -3.852 1.9 3.9
29. TYPE CONCRETE 79. 7 UNI GY -3.852 1.9 2.9
30. STRENGTH FCU 27579 80. 9 UNI GY -3.852 0 1
31. ISOTROPIC CONCRETE 81. MEMBER LOAD
32. E 2.17185E+007 82. 22 CON GX -0.141 0
33. POISSON 0.17 83. 22 CON GY -23.389 0
34. DENSITY 23.5616 84. 22 CON GZ -0.141 0
35. ALPHA 1E-005 85. 22 CMOM GX -0.233 0
36. DAMP 0.05 STAAD SPACE -- PAGE NO. 3
37. TYPE CONCRETE
38. STRENGTH FCU 27579 86. 22 CMOM GY 0 0

You might also like