Flusarc P-La: Catalogue
Flusarc P-La: Catalogue
FLUSARC P-LA
Up to 36 kV – 630 A – 25 kA
Catalogue
2010
FLUSARC P-LA Contents
■■ Overview............................................................................................................... 3
□□ General description......................................................................................... 3
□□ Features.......................................................................................................... 3
□□ Main advantages............................................................................................. 3
□□ Customer benefits........................................................................................... 3
■■ Operating conditions.......................................................................................... 4
□□ Degree of protection against accidental contact and ingress of foreigner objects..... 4
□□ Environmental and operating conditions......................................................... 4
□□ Standards and approval.................................................................................. 4
□□ Electrical features............................................................................................ 5
■■ Main characteristics............................................................................................ 5
■■ Product description............................................................................................. 6
□□ FLUSARC P-LA............................................................................................... 6
□□ Pressure gauge............................................................................................... 6
■■ Operating mechanisms....................................................................................... 7
□□ Closing the switch disconnector...................................................................... 7
□□ Opening the switch disconnector.................................................................... 8
□□ Movements of motorized control mechanism (Optional)................................ 9
□□ Manual operations........................................................................................... 9
□□ Remote operations.......................................................................................... 9
□□ Closing the switch disconnector...................................................................... 9
□□ Opening the switch disconnector.................................................................... 9
■■ Accessories....................................................................................................... 10
■■ Ecological considerations................................................................................ 11
■■ Installation.......................................................................................................... 12
□□ Isolators assembling..................................................................................... 12
□□ Outdoor assembling...................................................................................... 12
■■ Dimension and weights.................................................................................... 13
□□ Dimensions weights FLUSARC P-LA (24 kV)............................................... 13
□□ Dimensions weights FLUSARC P-LA (36 kV)............................................... 14
■■ Design data........................................................................................................ 15
□□ Motor wiring diagram.................................................................................... 15
■■ Shipping............................................................................................................. 16
□□ Packing......................................................................................................... 16
□□ Transport....................................................................................................... 16
□□ Handling........................................................................................................ 16
■■ Notes................................................................................................................... 17
2 Products-L4PS-FLUSARC_PLA-71920-V1-EN
Presentation Overview
Pole mounted switch disconnectors for
demanding outdoor environment
General description
KJA0072
We believe that flexible solutions and competent support are key elements for your
continued success.
Schneider Electric develops and supplies solutions finely tuned to user requirements
and standards.
The pole mounted FLUSARC family is the right solution in operation everywhere in
Medium Voltage Networks.
Features
The pole-mounted FLUSARC are switch-disconnectors insulated in SF6, reliable for
outdoor use. They can be connected to aerial lines.
Welding of components is carried out through the method called “TIG”, which
consists in melting the edges to be joined without weld material.
The external operating mechanism is very simple and reliable, since it is of the type
with independent operation on exceeding dead center; the contact operating shaft
rotates on bearings housed in a stainless steel box, which guarantees long
endurance.
Indication of the contact position (open/closed) and SF6 gas pressure are visible at
the foot of the pole through two inspection windows located under the operating
mechanism protection.
The operating mechanism cover is steel made, properly worked and painted in order
to withstand atmospheric agents.
Main advantages
■■ Advanced insulation materials;
■■ Stainless steel tank containing all the live parts and switching functions;
■■ Improved safety for both operating personnel and the public.
Customer benefits
■■ Uneffected by any climatic condition;
■■ Ideal for all pole type;
■■ Maximum service reliability;
■■ Easy inspection and maintenance;
■■ Easy installation and connection.
Products-L4PS-FLUSARC_PLA-71920-V1-EN 3
General Operating conditions
Ambient conditions
Temperature class Outdoor - 25
Insulating gas
Type Sulphur hexafluoride SF6)
Filling pressure at 20 °C (absolute) kPa 130
4 Products-L4PS-FLUSARC_PLA-71920-V1-EN
General Main characteristics
Electrical features
Rated voltage Ur [kV] 12 24 36
Power frequency withstand voltage (50/60 Hz, 1 min)
■■ towards the ground and between phases Ud [kV] 28 50 70
■■ across the isolating distance 32 60 80
Rated lightning impulse withstand voltage
■■ towards the ground and between phases Up [kV] 75 125 170
■■ across the isolating distance 85 145 195
Rated current Ir [A] 630 630 630
Breaking capacity of active circuits (cos φ 0.7) and ring circuits at 0.3
I1-I2a [A] 630 630 630
Vn
Number of making and breaking operation at rated current 420 420 420
Number of no load mechanical operation (class M2) 5000 5000 5000
Breaking capacity of no-load transformers I3 [A] 25 25 25
Breaking capacity of no-load lines/cables I4a-I4b [A] 25 25 25
Short time withstand current 1 s on main circuits and earth circuits Ik [kA] 12.5 / 25 12.5 / 25 12.5 / 16
Short time withstand current 3 s on main circuits and earth circuits Ik [kA] 12.5 / 20 12.5 / 20 12.5 / 16
Internal arc withstand current 1 s [kA] 12.5 / 16 12.5 / 16 12.5 / 16
Products-L4PS-FLUSARC_PLA-71920-V1-EN 5
General Product description
FLUSARC P-LA
KJA0051
Connections
The electrical connections to the main circuit are achieved by external cone
disconnectable sockets (connections which are in accordance with EN 50181 1997
type C interface standards).
Installation
2
KJA0058
Pressure gauge
KJA0059
6 Products-L4PS-FLUSARC_PLA-71920-V1-EN
General Operating mechanisms
■■ Insert the isolating rod into the operating lever hole of the switch disconnector.
KJA0054
■■ Grasp the isolating rod with both hands and pull down.
■■ Extract the isolating rod.
KJA0069
■■ The mimic diagram indicator will turn from the opened switch disconnector
position “O” to the closed switch disconnector position “C”.
Products-L4PS-FLUSARC_PLA-71920-V1-EN 7
General Operating mechanisms (contd.)
■■ Grasp the isolating rod with both hands and pull down.
■■ Extract the isolating rod.
KJA0068
■■ The mimic diagram indicator will turn from the closed switch disconnector position
“C” to the opened switch disconnector position “O”.
8 Products-L4PS-FLUSARC_PLA-71920-V1-EN
General Operating mechanisms (contd.)
Manual operations
Manual operations can always be performed, when remote operations are not
possible: for example missing of supply.
Remote operations
The switch disconnector can be operated from remote through a properly set up
control panel.
The operating mechanism is of overcoming dead center type. The spring is loaded
before the operation.
There is available an exchange contact to indicate the switch disconnector position.
Products-L4PS-FLUSARC_PLA-71920-V1-EN 9
General Accessories
The gear motor is equipped with an electronic card, controlling its operation.
Auxiliary Contacts
They are open/closed signalling contacts.
■■ Auxiliary contacts 2 Normally Open (NO) + 2 Normally Closed (NC) line
Electric characteristics:
Auxiliary contacts
10 Products-L4PS-FLUSARC_PLA-71920-V1-EN
General Ecological considerations
Plastics can also be recycled. The thermosetting plastics can be fragmented and
reused as fillers in other plastic components; the thermoplastic materials can be
recycled in new plastic components. This means that the material is recovered,
processed and reused in the manufacture of new parts.
Disposal valve
To ensure efficient and environmentally friendly dismantling and sorting of materials
by responsible disposal experts, all plastic components are identified accordingly.
Moreover, material and utilization data sheets are available to provide the customer
with an overview about the materials used, and the disposal company with important
information regarding the recycling process.
Thus, the materials used for our products can be 100% recycled.
This provides a vital contribution to savings in global primary energy and material
resources.
All materials were selected and developed so that, for example, switch disconnector
affected by a fire in a building would have a minimal effect on the fire load (heat
development and pollutants in the emissions).
The high-voltage conducting parts of our gas-insulated switch disconnector units are
hermetically sealed in an insulating inert gas (sulphur hexafluoride SF6 which is
neither reactive nor toxic). Thus, all environmental influences which could reduce the
service life are kept outside. The particular characteristic of the insulating gas also
enables the overall size to be decreased by approximately 30% compared to switch
disconnector without insulating gas designed with equivalent technical
characteristics. This again saves on material and saves on the energy required to
produce the material. The amount of insulating gas used in FLUSARC P-LA is
approx. 0.5% of the total weight of the switch disconnector.
Once the switch disconnector’s service life has ended, the gas can be completely
extracted via the disposal valve provided in each gas-filled compartment, and then
recycled. To this end, the gas suppliers have developed an efficient recycling
method.
In normal operation, the gas need never be replenished during the entire service life.
The switch disconnector has been designed as a hermetically sealed pressure
system according to IEC 60694 and EN 60694.
Products-L4PS-FLUSARC_PLA-71920-V1-EN 11
FLUSARC P-LA Installation
Isolators assembling
KJA0060
Outdoor assembling
After assembling the outdoor isolators, refer to the following figure and perform the
procedure:
■■ Apply the switch disconnector support (1) to the pole (2) and fix it with strips (3);
■■ Place the switch on its support by a crane equipped with a suitable cable,
connected to the lifting eyebolt;
■■ Fix the switch to the support with a (4) M12 x25 bolt and apply 50 Nm ±5 tightening
torque.
12 Products-L4PS-FLUSARC_PLA-71920-V1-EN
FLUSARC P-LA Dimension and weights
motorized version
manual version
Weights
80 kg 24 kV without motor
Approx.
85 kg 24 kV with motor
Products-L4PS-FLUSARC_PLA-71920-V1-EN 13
FLUSARC P-LA Dimension and weights (contd.)
motorized version
manual version
Weights
120 kg 36 kV without motor
Approx.
125 kg 36 kV with motor
14 Products-L4PS-FLUSARC_PLA-71920-V1-EN
FLUSARC P-LA Design data
Fixed bridge
Remote control
rosso
bleu
Legend
M Opening and closing motor
Diode 1N4007
IMS Auxiliary contacts line LBS
Varistor Zinc Oxide
C Remote closing signal
O Remote opening signal
Terminal printed circuit board
RA Opening relay
RC Closing relay
Terminals
KT Electronic timer excitation delayed
Products-L4PS-FLUSARC_PLA-71920-V1-EN 15
FLUSARC P-LA Shipping
Packing
Strictly observe the symbols and the instructions indicated on the packing.
The FLUSARC P-LA switch disconnectors are usually packed either inside a
cardboard box or in a wooden case and firmly fastened at the base of a wooden
pallet, but they can also be packed with other methods, according with the shipment
and storing requirements and complying with the Customer requests.
The apparatuses are protected by polystyrene foam panels and wrapped in a
waterproof plastic housing, in order to prevent any water infiltrations during the
loading and unloading phases and to protect them from the dust during storage.
Leave the equipment in its original packaging during storage. If units or parts are
unpacked for checking, they must be repacked for continued storage, using the
original packaging. Avoid condensation.
Transport
The motor vehicle used for the transport must be equipped with the loading platform
realized in an anti-slip material with a high friction coefficient.
The switch disconnector must be positioned on the loading platform transversally
back to back, by interposing materials fit for absorbing the compressions and for
eliminating any possible direct contact of the surfaces of the different apparatuses.
On the loading platform, purposed longitudinal members must be disposed, in order
to space every switch disconnector and to prevent both its longitudinal and its
transversal shifting.
The different switch disconnector must be anchored to the motor vehicle structure by
means of ropes, in order not to provoke deformations and to prevent their possible
turnover on curves or in case of a sudden braking.
Besides, the motor vehicle used for the transport must be equipped with a covering
sheet.
Handling
LOA4400
In order to lift the FLUSARC P-LA switch disconnector inside their packing, use a lift
truck having an adequate lifting power with respect to the apparatus weight, by
taking care to verify that the packing keeps perfectly balanced during the lifting
Cas
e
Gro N.
ss
Net Weigh
phase.
W t
Type eight
Kg
Kg
Com
-Ord
.
Des
tin
Adr atario
ess
Once the packings have been removed, in order to lift the FLUSARC P-LA switch
disconnector, use the purposed eyebolts predisposed on their top, by using either a
bridge crane, a crane or a lift truck having a suitable lifting capacity with respect to
KJA0302
16 Products-L4PS-FLUSARC_PLA-71920-V1-EN
Appendices Notes
Products-L4PS-FLUSARC_PLA-71920-V1-EN 17
Appendices Notes
18 Products-L4PS-FLUSARC_PLA-71920-V1-EN
Appendices Notes
Products-L4PS-FLUSARC_PLA-71920-V1-EN 19
© 2010 Schneider Electric - All rights reserved
Schneider Electric As standards, specifications and designs change from time to time, please ask for confirmation
35, rue Joseph Monier of the information given in this publication.
CS 30323
92506 Rueil-Malmaison Cedex, France This document has been printed
on ecological paper
RCS Nanterre 954 503 439
Capital social 896 313 776 € Publishing: Schneider Electric
www.schneider-electric.com Design: Schneider Electric
Printing:
Products-L4PS-FLUSARC_PLA-71920-V1-EN 10-2010