CORONA
PANEL SPECIFICATIONS:
GBA
PANEL TYPE
Manual Electric Flame Front Generator
TERMINAL POINTS
REF. NO:
CF17.2513
Feb 7, 2017
Ignition Method Flame Front Fuel Gas Inlet 1" NPT A-105 Ignition Cable n/a
Auto Relight no Pilot Gas Inlet 1" NPT A-105 Terminal Strip n/a
Flame Detection n/a Pilot Gas Out Remote Alarms n/a
Area Classification Unclassified Purge Gas Out
Mounting Backplate for Wall Mounting Flame Front Out 1" NPT A-105
Enclosure Material Aluminum
Enclosure Rating NEMA 4X PIPE SPECIFICATIONS
DIMENSIONS/WEIGHT (approx.) Pipe Size and Material Sch. 80 Carbon Steel
Weight 600 LBS Connections / Fittings 3000 # Screwed Fittings
Dimensions (L x W x H) 3' x 2' x 6' Flanges n/a
NEMA 4X
Electrical
Enclosure
Regulator To Pilot
PI Check Valve Ignition Lines
Fuel Gas
Inlet
Regulator Ignition
Chamber
PI Check Valve
Ignition Air
Inlet
This offer may not include all items shown.
UTILITY REQUIREMENTS PANEL EQUIPMENT / INSTRUMENTS
Ignition Fuel Gas (ignition cycle) 100 scfh @ 25psig Pilot Status Lights n/a
Ignition Air (ignition cycle) 1100 scfh @ 25 psig Manual Ignite Switch One
Pilot Fuel Gas n/a Selecter Switch n/a
Purge Fue Gas n/a Alarms n/a
Electric 110VAC / 1 / 60Hz Ball Valves Two
NON DESTRUCTIVE EXAMINATION Pressure Regulators Two - Fisher Series
RADIOGRAPHY 10 % of butt welds Pressure Gauges Two
ADDITIONAL NDE none Solenoids n/a
SURFACE FINISH / PAINT (carbon steel) Check Valves Yes
SANDBLAST SP-6 PLC n/a
PRIMER CZ-11 2-3 mil Temperature Switches n/a
TOP COAT none