General Data
Models (RAS) RAS-3HVRNE RAS-4HVRNE RAS-5HVRNE RAS-4HRNE RAS-5HRNE
Power Supply – 1-230V / 50Hz 3-400V / 50Hz
Colour (Munsell Code) – Natural Grey (1.0Y8.5/0.5)
Sound Pressure Level
Night Mode
Sound Pressure Level
dB (A)
dB (A)
43 / (41)
64
45 / (41)
66
47 / (43)
69
45 / (41)
66
47 / (43)
68
AquaFREE System
Outer Dimension
Height mm 800 1240 1240 1240 1240
Width mm 850 950 950 950 950 Hitachi’s AquaFREE system is a Heat Pump heating system
for winter, and a partial cooling system for summer. The system
Depth mm 315 315 315 315 315
consists of an Inverter Heat Pump outdoor unit and a hydraulic
Net Weight kg 60 95 97 100 102 module indoor unit. The heat pump absorbs or sends the heat
to the outside, and transfers it to the water circuit by means
Refrigerant Type – R410A of the AquaFREE module.
Flow Control – Micro Processor Controlled Expansion Valve The AquaFREE air conditioning system incorporates a set of
technical benefits that make it one of the most attractive on the
Type Compressor – Hermetic (Rotary) Hermetic (Scroll) Hermetic (Scroll) Hermetic (Scroll) Hermetic (Scroll)
market. Right from selection of the ideal type of equipment in
Quantity – 1 1 1 1 1 each case, up to its maintenance, and through installation,
start up and operation. AquaFREE always provides the best
Power mm 0.98 1.38 1.38 2.2 3.0 solution for every user and greatly simplifies and eases the
Heat Exchanger – Multi-Pass Cross-Finned Tube user’s selection process.
AquaFREE systems provide great comfort, high reliability,
Condenser Fan (Type) – Propeller Fan Propeller Fan Propeller Fan Propeller Fan Propeller Fan
rigorous design, low electrical consumption and require less
Quantity – 1 2 2 2 2 installation space than a conventional boiler.
Air Flow Rate m /min
3
45 80 90 80 90
Power W 50 30 + 50 50 + 70 30 + 50 50 + 70 Applications
Refrigeration Piping – Connection with nuts • Under floor heating and cooling
• Low temperature radiators
Connections Size
• Swimming pool heater
Gas mm (inches) Ø9.53 (3/8”)
Savings and Ecology
Liquid mm (inches) Ø15.88 (5/8”)
• Use of highly efficient Hitachi DC Inverter technology
Refrigerant Charge kg 2.4 3.6 3.6 3.6 3.6
• Estimated savings of approx. 60% over traditional
Maximum Current A 25 32 32 11 15 heating methods
• Manufactured to RoHs Environmental Directive
Packaging Dimensions m3 0.34 0.55 0.55 0.55 0.55
NOTES:
The nominal cooling and heating capacity is the combined The Sound Pressure Level is based on the
capacity of HITACHI’s AquaFree system, and it based with following conditions:
the following standards: 1 meter from unit’s front surface
Cooling capacity EN 12055 Voltage of the power source is 230V
Heating capacity reverse cycle units EN 255
Operation conditions Cooling Heating
The above data was measured in an anaechoic
chamber so that reflected sound should be taken
email: [email protected]
Water Temperature
Inlet
Outlet
23.0oC
18.0oC
36.0oC
30.0oC
into consideration when installing the unit.
www.hitachiaircon.com
Outdoor Air inlet DB 35.0oC 7.0oC Hitachi Europe Ltd, Whitebrook Park, Lower Cookham Road,
Temperature WB - 6.0oC
Maidenhead SL6 8YA
Piping Length: 7.5 metres / Piping lift: 0 meters
DB: dry bulb / WB: wet bulb
AquaFREE Standard Models (Swimming Pool models also available) AquaFREE Models with Electric Heaters (Swimming Pool models also available)
General Data General Data
Models (RWM) RWM-3FSN1E RWM-4FSN1E RWM-5FSN1E Models (RWM) RWM-3FSN1E / 4.5H1 RWM-4FSN1E / 6H1 RWM-5FSN1E / 6H1 RWM-4FSN1E / 6H3 RWM-5FSN1E / 6H3
Power Supply – 1-230V / 50Hz Power Supply – 1-230V / 50Hz 3-400V / 50Hz
Cooling for Radiant Floor Cooling for Radiant Floor
Min kW 3.9 4.9 6.7 Min kW 3.9 4.9 6.7 4.9 6.7
Norm kW 7.1 10.0 12.5 Norm kW 7.1 10.0 12.5 10.0 12.5
Max kW 8.0 11.2 14.0 Max kW 8.0 11.2 14.0 11.2 14.0
EER – 3.51 3.22 3.54 EER – 3.51 3.22 3.54 3.22 3.54
Heating for Radiant Floor Heating for Radiant Floor
Min kW 4.0 5.7 7.0 Min kW 4.0 5.7 7.0 5.7 7.0
Norm kW 8.0 11.2 14.0 Norm kW 8.0 11.2 14.0 11.2 14.0
Max kW 10 14.6 16.7 Max kW 11.5 14.6 16.7 14.6 16.7
COP – 4.05 3.46 3.47 COP – 4.05 3.46 3.47 3.46 3.47
Pump Input Power W 93 93 132 Auxiliary Heating
Sound Pressure Level dB (A) 27 28 28 Min / Med / Max kW 1.50/3.00/4.50 2.00/4.00/6.00 2.00/4.00/6.00 2.00/4.00/6.00 2.00/4.00/6.00
Outer Dimension Pump Input Power W 93 93 132 93 132
Height mm 900 Sound Pressure Level dB (A) 27 28 28 28 28
Width mm 526 Outer Dimension
Depth mm 372 Height mm 900
Net Weight kg 38 39 40 Width mm 526
Refrigerant Type – R410A Depth mm 372
Refrigerant Piping Connections – Connection with nuts Net Weight kg 42 44 45 44 45
Connections Size Refrigerant Type – R410A
Gas mm (inches) Ø9.53 (3/8”) Refrigerant Piping Connections – Connection with nuts
Liquid mm (inches) Ø15.88 (5/8”) Connections Size
Water Pipe Connection – Connection with nuts Gas mm (inches) Ø9.53 (3/8”)
Connections Size Liquid mm (inches) Ø15.88 (5/8”)
Circuit mm (inches) Ø25.4 (1”) Water Pipe Connection – Connection with nuts
Supply mm (inches) Ø19.05 (3/4”) Connections Size
Water Working Pressure (Nom) mAq 3.5 2.5 2.3 Circuit mm (inches) Ø25.4 (1”)
Expansion Vessel Volume – 5 Supply mm (inches) Ø19.05 (3/4”)
Maximum Current A 0.5 0.5 0.6 Water Working Pressure (Nom) mAq 3.5 2.5 2.3 2.5 2.3
Packaging Dimensions m 3
0.2 Expansion Vessel Volume – 5
Cabinet Colour – Aluminium Grey Maximum Current A 20.1 26.5 26.6 26.5 26.
Remote Control SW – CTA-IMH RF A Packaging Dimensions m 3
0.2
Cabinet Colour – Aluminium Grey
Remote Control SW – CTA-IMH RF A