FMS Lamtec Manual
FMS Lamtec Manual
Approvals.
SIL 3
DIN EN 61508 Parts 2+3
0085
EC Type Examination Certificate
EU/2009/142/EC
DIN EN 298
DIN EN 13611
DIN EN 1643
DIN EN 12067-2
EC Declaration of Conformity
2014/35/EU (Low Voltage Directive)
2014/30/EU (EMC Directive)
2014/68/EU (Pressure Equipment Directive Cat. 4
Mod.) B+D
2009/142/EC (Gas Appliances Directive)
2
The FMS Combustion Management
System.
These days, combustion systems are expected to meet one requirement above
all others: efficiency. And this demand no longer just applies to the technology
itself, we also expect the installation, configuration and commissioning
processes to be effective as well.
www.lamtec.de 3
LAMTEC | Combustion Management System | FMS
Advantages:
Fail-safe burner control unit Integrated CO/O2 control
Electronic fuel/air ratio control with up Sliding controlled fuel change
to 5 channels Simultaneous combustion of 2 fuels
Universal field bus interface with variable mix ratio
for connection to control technology Oil gun purge function
Integrated power controller (optional) Possibility to resolve safety interlock
Integrated valve leakage test (optional) chain when used in combination with
NEMS16
VISIOCONTROL
NEMS16 GKI300
LAMTEC
LAM
MTEC SYSTEM BUS
KOM-processo orr
KOM-processor
module
fieldbus modu
(CO + O2)
KS1D (C LSB
B module FMS
LT3-F
Boiler pressure
Flame sensor
M
Frequency
K5 = 832
converter
M
Pick-up sensor
4
The FMS' analogue inputs can be configured using plug-
in cards at various physical input sizes. A number of soft-
ware functions, e.g. the pre-ventilation period, can be
parameter set by the commissioning engineer on site.
Modular options.
Relay module for burner management
For use in burner management, the FMS emits nine digital
signals that are converted into twelve output signals for
230 VAC using the relay module 660R0016/R0016 V4.3.
www.lamtec.de 5
LAMTEC | Combustion Management System | FMS
Inputs. Outputs.
Pre-ventilation suppression Main gas 1
Digital inputs Burner sequencer/
Burner "ON" 24 V valve actuation
Main gas 2
Flame signal
Safety interlock chain Depending on Oil
Control release
power supply
Fault release Ignition valves
Relay module R16
Acknowledgement Ignition transformer
of high firing rate
Pilot flame signal Oil operation indication
Recirculation ON
Fan
General safety interlock chain
Oil safety interlock chain Gas operation indication
Fuel selection
Oil distribution
Acknowledgement of
ignition position
Pre-ventilate
Valve leakage test
Air pressure monitor Fault in FMS
Flame intensity
6
Basic model.
The LAMTEC FMS Combustion Management System can be adjusted via a PC interface, enabling users to work
be operated directly on the device. Password protection remotely, e.g. using a laptop.
prevents data from being entered unintentionally.
Thanks to its modular design, the FMS provides a high
degree of flexibility for any application. Settings can also
www.lamtec.de 7
LAMTEC | Combustion Management System | FMS
Optional components.
Startup Manager Control technology link-up
The "Startup Manager" function also supports the com- The FMS is easy to combine with existing control
missioning engineer both during the initial installation technology. It “speaks” virtually all languages used by
of the burner and when adjusting the burner settings conventional fieldbuses. Connections for PROFIBUS-DP,
using the wizard. TCP/IP (MODBUS TCP), MODBUS and INTERBUS-S are
available as options (other bus systems on request).
PROFIBUS DP fieldbus.
Startup Manager.
MODBUS fieldbus.
Analogue input/output.
8
PC interface (RS232) Rotational speed sensor
The PC interface makes working with the FMS even eas- There are two different speed sensors available for the
ier: The device can be operated remotely using a laptop. FMS. The 663R8101 speed sensor is equipped with two-
Set configurations and curve data can be archived – this line technology and has a switching distance of 2 mm.
backs up data so that it can be re-imported in the event The 663R8103 speed sensor is an inductive proximity
of an emergency, enabling the device to be ready for op- switch with switch contact in three-line technology and
eration again in just a few minutes. By using an industri- has a switching distance of 4 mm. This means that you
al modem, you can check the status of the FMS from can always find the right sensor for the design features
your office so that you can detect faults and their causes in question. As the elements to be recorded are not
without having to be on-site. always known, approximate values should be used for
sizing the damping elements and selecting the appro-
priate sensor. Due to the variety of sensors that can
be used, LAMTEC only offers a two-line and a three-line
element. These have been selected to ensure that
most measuring tasks can be covered with just these
two elements. Please let us know if neither of these
elements is suitable for a specific measuring task, we
will be happy to find a solution.
CO/O2 controller
Combustion processes are subject to constant interfer-
ence from changes in temperature, moisture levels,
air pressure and changes to the quality of the fuel used
(oil viscosity, gas fuel value). The CO/O2 control integrat-
ed into the FMS helps to compensate for these influenc-
es during ongoing operation (shift in the fuel/air ratio
curves). It includes a software module that we have de-
veloped specifically for combustion control. This module
translates the precise values from our CO/O2measuring
devices to automatically control the air supply as re-
quired in real time. For example, it automatically reduces
the air supply until CO is produced. It is always able to
detect CO/O2, no matter how small the quantity. The
assembly then increases the air supply by one step
and thus generates an individual operating curve in Rotational speed sensor with 2 wires, Namur.
line with the local conditions with which the burner still
just burns without CO. The system learns and improves
almost automatically in a sustainable and fail-safe
manner. This means that almost every combustion sys-
tem will always run at the ideal combustion point.
www.lamtec.de 9
LAMTEC | Combustion Management System | FMS
Actuating motor.
10
Notes.
www.lamtec.de 11
LAMTEC | Combustion Management System | FMS