Portable Ultrasonic Flowmeter
UFP-20
Versatility! Functionality! Reliability!
Features
1 Multi-Flow Measurement Function
Easy configurable for 2-Channel or 2-Path measurement.
2 Energy Meter Function
Energy flow rate measurements with Pt-100 RTD option.
Send Temp RTD direct connection!
Heat
Heat source
load
Return Temp
3 Receiving-Echo Monitor Function 4 Weather-proof structure IP65
IP65 rating maintained even
Visual confirmation during measurement.
that receiving
echo is “good”.
IP65
5 USB Memory Data Transfer
Logged data and site conditions can be
storaged into internal memory.
USB
Weather-Proof connectors
Copy through
USB memory
Flowmeter PC
General Specifications
Measurement Applicable Fluid Homogeneous and sonically conductive fluids
(water, waste water, industrial water, sea water, pure water, oil, ethylene glycol-water solution, etc)
Range Converted to flow velocity: −30 m/s to +30 m/s
Method Ultrasonic pulse transit time difference method
Pipe Condition Diameter DN13 mm ∼ DN5000 mm
Material Materials which allow stable transit of ultrasonic waves such as steel, SUS,
castings, ductile casting, PVC, FRPM, etc. (Note: Applicable diameters may vary with material.)
Lining None, tar epoxy, mortar, etc.
Transducer Applicable diameter Applicable Temperature
Small Transducer DN 13 ∼ 50 mm −20 ℃ ∼ +120 ℃
Medium Transducer DN 65 ∼ 500 mm −20 ℃ ∼ +120 ℃
(DN20 mm∼DN50 mm)
(*1)
Large Transducer DN 300 ∼ 5000 mm −20 ℃ ∼ +80 ℃
Measurement Accuracy (of reading) Velocity ≧ 1m/s Velocity < 1m/s
DN 13 mm(*2)∼ 90 mm ±2.0 % ±0.02 m/s
(DN20 mm ∼ DN50 mm)
(*1) (±2.0 % ∼ ±5.0 %)
(*1) (±0.02 m/s ∼ ±0.05 m/s)
(*1)
DN 100 mm ∼ 250 mm ±1.5 % ±0.015 m/s
DN 300 mm ∼ 5000 mm ±1.0 % ±0.01 m/s
Logging Function Approx. 165,000 points
Date, Instantaneous flow rate, +Total, −Total, Flow velocity, Error code (Selectable)
Internal logged data transferred through USB memory in CSV format
Temperature Input 4pcs of RTD (Pt-100) as Max.
(For Energy measurement, they can be connected main unit through junction box.)
Analog Output 1 port ; DC4−20 mA Allowable load resistance 550 Ω Max.
Display LCD(320 x 240 Dot Matrix)/ high-intensity Backlight equipped
Function ・2-Channel / 2-Path measurement (with additional pair of transducers)
・EASY interfacing with Installation Wizard
・Thickness meter function
(Range; 1∼100 mm / Accuracy; ±0.1 mm or ±1.5 %R.D. which is larger)
・Sonic Velocity measurement function
(Range; 500∼3000 m/s / Accuracy; ±5 %)
・Receiving-Echo monitoring function
・Multi-Language support
(English, French, German, Italian, Portuguese, Russian, Spanish, Turkish)
・Metric / English (inch, gallon or barrel) units selectable
・Low flow cut
・Zero shift / Span compensation
・Self-diagnostics
・Filtering
Cable 7 m as standard (157 m Max. Extendable)
Ingress Protection IEC 60529 Protection Degree IP65 (Main Unit and Transducers)
Power Supply DC 10 ∼ 30 V / AC adaptor applicable on AC 90 ∼ 264 V 47 ∼ 63 Hz
Internal Battery 8 hours as Max. / Rapid charging 4 hours
Operating Temperature −10 ℃ ∼ +50 ℃ (for Main unit)
Dimension & Mass 135(W)× 250(L)× 68(H)/ Approx. 1.4 kg (including battery)
(*1) : Medium transducer is recommended for measurement of DN20 mm ∼ DN50 mm pipe which attenuates sonically like Zinc-coated-pipe.
(*2) : Site calibration will be required.
■ Medium Transducer ■ Mounting Fixture for Medium Transducer
Design and specifications are subject to change without prior notice, and without any obligation on the part of the manufacturer.
CAUTION Before operating this equipment, you should first thoroughly read the operator's manual.
www.tokyo-keiki.co.jp/ryutai/
Control Division! Fluid Management Systems SBU
Head Office 2-16-46, Minami-Kamata, Ohta-ku Tokyo 144-8551, JAPAN
TEL.+81-3-3737-8621 FAX.+81-3-3737-8665
TOKIMEC changed the name of the company to TOKYO KEIKI on October 1 . 2008. June 2009 Cat.No.1332-3-E-1-RG