Advanced Radiography System Features

This document describes a radiography system called the RADspeed fit VX package. The system provides stress-free flexible positioning through a combination of tabletop movement and x-ray tube support. It offers smart operation features like an electromagnetic lock system for easy positioning and an all-free switch for speedy positioning. The system also aims to improve reliability with a large output power for high image quality and a sturdy floating tabletop that can support up to 320 kg.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (1 vote)
636 views11 pages

Advanced Radiography System Features

This document describes a radiography system called the RADspeed fit VX package. The system provides stress-free flexible positioning through a combination of tabletop movement and x-ray tube support. It offers smart operation features like an electromagnetic lock system for easy positioning and an all-free switch for speedy positioning. The system also aims to improve reliability with a large output power for high image quality and a sturdy floating tabletop that can support up to 320 kg.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
  • Introduction to RADspeed fit VX Package: Provides an overview of the RADspeed fit VX package, highlighting its use in radiography and features relevant to modern medical imaging.
  • Clinical Needs for Flexible Positioning: Details the system's ability to accommodate various patient positions and clinical requirements.
  • Need for Ease of Use and Smart Operation: Describes the user-friendly features and smart operations that make the system suitable for everyday clinical use.
  • Stress-Free Flexible Positioning: Explains the positioning capabilities, focusing on ease and flexibility in radiographic setups.
  • VX Package Features: Outlines the specific features of the VX package, such as detectors and user interfaces to improve workflow.
  • High Reliability and Dose Optimization: Highlights the system's reliability features and mechanisms to optimize patient radiation dose.

Radiography System

RADspeed fit VX package


Radiography System

RADspeed fit VX package Fits Your

2
Clinical Needs for Flexible Positioning
Needs for Ease of Use and Smart Operation

This radiography system integrates ease-of-use features


from top-class systems in a simple manner.
The system is equipped with a floating tabletop that can
support up to 320 kg, and a detachable grid to reduce
patient exposure. Furthermore, with its high image quality
due to the large output power and simple operability, this
radiography system provides a sense of ease and comfort
unique to Shimadzu.

Sma r t O p e rati on Re li a bili t y

3
18 0 c m

R a d i o g ra p hy ra n g e R a d i o g ra p hy ra n g e

4
S m a r t O p e rat i o n Reliability Stress- Free Flexible Positioning

Offers Unimaginably Wide Radiographic Coverage Through a Combination


of Tabletop Movement and X-Ray Tube Support
Although the main unit is compact, the tabletop and X-ray tube can be moved
freely over a wide range, for truly easy positioning.

Electromagnetic Lock System Offers Sure and Easy Positioning


Thanks to the one-touch electromagnetic lock system, making fine adjustments to
the radiography position, and securing it firmly, can be done easily and smoothly.
The exposure field lamp lights up automatically during lateral movement of the
table top to make sure of the positioning.

The All-Free Switch Enables Speedy Positioning


with Minimum Operations
To support speedy positioning, the system is equipped with an All-Free switch that
allows you to freely move the X-ray tube vertically or laterally with a single touch.

X-ray Tube Arm Swivel Capability Supports Stretcher or


Wheelchair Examination
The X-ray tube arm can pivot 180° around the support column, so you can
perform radiography with a stretcher or wheelchair along the far side of the
tabletop. Radiography can be performed smoothly even during emergency
transport. (Rotation is mechanically locked.)

5
FPD - Your flexbile choice

14×17’’
Csl
Wireless Wired
10×12’’ 17×17’’ GoS

FPD Size Access Sensor

6
VX package
Flat Panel X-ray Detectors
New slim and portable cassette-size flat panel detector will be the best solution for digtal radipgraphy. High spatial resolution with
140um pixel array ensure high image quality for precise diagnosis performance. Both CsI and Gadox scintillator types are available.

Quick Preview and Smart GUI


Enhance Work Flow
After exposure, a preview image immediately appears on the display of DR console in less than
two seconds. DR console has a user-friendly graphic interface adding new and powerful
proprietary functions. GUI design can be modified to customer preferences flexibly, succeeding
the conventional console design.

DR acquisition viewer
with simple workflow

・Easy operation and high throughput


・User-friendly touch GUI
・Useful functions : Auto Grooping,Auto Grid Suppression,
Stitching
Auto Labeling,Auto Rotation,Free
Rotation,Multi Layout,etc.
・DICOM 3.0 Compatible : MWL,Send,Print,MPPS,etc.
S m a r t O p e rat i o n Reliability User- Friendly Operation

Simple Operation with 432 Anatomical Programs 3 × 8 × 3 × 6


Radiography Examination Radiography Body
Radiography conditions are easily configured, thanks to an anatomical program system. method position direction thickness

The optimal radiography conditions can be configured quickly by combining the


radiography technique with the anatomical position, the radiography direction, and the 432
Radiography
body thickness. memory
*)

New Exam Navigation System Helps You to


Make Appropriate Examinations
When the radiography position and radiography technique are selected, a new navigation
program displays information such as the radiography distance, the cassette size, and
whether the grid is necessary. Accurate preparations for radiography can be performed
smoothly, even at busy facilities.

Color-Coded LED Status Indicator


A status indicator has been adopted in this class to color code the system status. This is
achieved using environmentally friendly LEDs.

*)Note
This number represents the maximum number of APR which can be registered under analog
system of RADspeed fit. The registrable number varies when combined with XD package.
S m a r t O p e rat i o n Reliability High Reliability, Dose Optimization

Large Output Power Achieves Top-Class 32kw 56kw


Image Quality
500 630
This system is equipped with a large-output X-ray high-voltage generator with a
mA mA
maximum tube current of 500 mA (32 kW type) or 630 mA (56 kW type), levels
that are unprecedented in conventional integrated radiography systems. This
provides imaging quality on par with top-class models, and improves the quality of
X-ray image diagnoses.

Sturdy and Smooth Floating Tabletop Movement


The tabletop can support up to a 320 kg patient load. Examinations can be 320
performed safely even on larger patients or when assistance on the tabletop is
kg
required.

Power-Saving Design in Harmony with Nature


25%power
Although radiography systems consume large amounts of power during radiogra- consumption
reduction
phy operations, they are almost always on standby while switched on. The
RADspeed fit is equipped with an energy-saving feature that limits standby power
during idle time.

Detachable Grid Ensures Both Low Patient


Exposure and High-Quality Images
During pediatric radiography, the grid can be removed to reduce radiation. As a
result, unnecessary radiation during examinations is eliminated.

Answering the Patient's Concerns about


Radiation Exposure
Recently, there are increasing concerns about X-ray radiation in clinical
practice. In response to this and to reduce dosages, the RADspeed fit
includes a function that calculates and displays the anticipated X-ray
dosage prior to exposure (option). This makes it easy to answer questions
from the patient about the degree of exposure.