2016.

6
Aim of this manual
This manual describes the daily care, both sides adjustment and image quality adjustment
procedures. These daily adjustments are important for stable printings.
This manual will be useful to enable the full capabilities of this machine to realize stable
printings.

Notations and symbols used in this manual

CAUTION
This symbol indicates that negligence of the instructions may lead to mishandling that may cause injury
or property damage.

NOTICE
This symbol indicates a risk that may result in damage to this machine or originals.
Follow the instructions to avoid property damage.

Tips
This symbol indicates information that complements the topic or optional devices required to use a certain function.
Reference
This symbol indicates a function or functions that are related to the topic.

The meaning of other notations and symbols are as follows.

Notation/Symbol Description
[] These brackets indicate the name of a key on the touch panel or of a button on a
computer screen.
Bold Words in bold type indicate the name of a key on the control panel, of a part, of an
option, or of User's Guide.

This guide describes product names and system configurations as follows.

Product name Conventions used in this guide


bizhub PRESS C1100/C1085 This machine: Indicates the entire system including options and functions.
The main body: Indicates a main unit that covers printing functions.
The machine: Indicates a mechanical part related to the structure or mechanism.
Microsoft Windows Windows
bizhub PRESS C1100/C1085

Intended use of this machine

Intended use

This machine is designed to be used as a digital printing system for the following purposes:
- Print, copy and scan documents.
- Use available finishing functions such as duplexing, stapling, hole-punching, multi-folding and booklet creation
if appropriate options are installed.
- Store documents to reprint on the HDD of this machine.
The intended use also requires that:
- The system is used within the limits of device specifications and specifications of optional components,
- All safety instructions in the related user's guides are observed,
- Legal restrictions on copying or printing (refer to instruction booklet "Safety Information") are observed,
- Inspection and maintenance instructions are adhered to,
- General, national and company safety provisions are observed.

Impermissible operating conditions

The system may not be operated if:


- Errors or damage have been discovered,
- Maintenance intervals have been exceeded,
- Mechanical or electrical functions do not work as they should.

Exclusion of liability

The manufacturer of the system assumes no liability for damages if the system was operated under impermissible
conditions.

Target groups
The Daily Maintenance Guide are intended for the following users of this machine:
- Operator: Person who has been trained by Konica Minolta or authorized partner to operate the system for its
intended use as well as manage consumables, and perform the maintenance and troubleshooting described in
user's guides.
Everyone who uses this system must have read and understood the related user's guides.

i
Contents
Intended use of this machine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i
Intended use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i
Impermissible operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i
Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i
Target groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii

1 DAILY CARE
About daily care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Cleaning timing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Cleaning the duplex section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Cleaning section of the duplex section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Cleaning procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Cleaning the centering sensor (Paper feeder unit PF-707/PF-708) . . . . . . . . . . . . . . . . . . . . 1-6
Cleaning the roller of the humidification section
(Relay conveyance unit RU-511). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7

2 BOTH SIDES ADJUSTMENT


About both sides adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Adjustment flow
when using a new paper brand, a new paper weight, or a new paper size . . . . . . . . . . . . . . 2-1
Adjustment timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Adjustment order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Regular adjustment flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Adjustment timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Adjustment order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Adjustment flow for each job . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Adjustment timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Adjustment order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Contents of both sides adjustment items. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Placing paper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Front side adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Gap adjustment (When not using PF-708 scanner) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
Scan measurement adjustment (When using PF-708 Scanner). . . . . . . . . . . . . . . . . . . . 2-16
Registering the paper profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-24
Back side fine adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-26

3 IMAGE QUALITY ADJUSTMENT


3.1 Image quality adjustment for Image Controller IC-602 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
About Quality Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Regular adjustment flow (High accuracy) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Adjustment timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Adjustment order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Adjustment flow when changing the screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Adjustment timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Adjustment order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Contents of the image quality adjustment items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Change setting of Custom Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Gamma Automatic Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6
Density Balance Adjustment (for i1Pro/i1Pro2/ES-1000/ES-2000) . . . . . . . . . . . . . . . . . . 3-7
Density Balance Adjustment (for FD-5BT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16
Added procedures of Density Balance Adjustment
(Registration of color measurement data using a USB memory) . . . . . . . . . . . . . . . . . . . 3-24
Maximum Density Auto Adjustment (RU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-26

ii
bizhub PRESS C1100/C1085

Check setting of Color Density Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-28


Color Density Manual Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-31
Exact Color (for i1Pro/i1Pro2/ES-1000/ES-2000, or FD-5BT) . . . . . . . . . . . . . . . . . . . . . 3-33
G7 Calibration (for i1Pro/i1Pro2/ES-1000/ES-2000, or FD-5BT) . . . . . . . . . . . . . . . . . . . 3-39
3.2 Image quality adjustment for Image Controller IC-308/IC-310 . . . . . . . . . . . . . . . . . . . . . . . . . 3-45
About Quality Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-45
Regular adjustment flow (High accuracy) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-45
Adjustment timing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-45
Adjustment order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-45
Adjustment flow when changing the screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-46
Adjustment timing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-46
Adjustment order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-46
Contents of the image quality adjustment items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-47
Change setting of Custom Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-47
Gamma Automatic Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-49
Density Balance Adjustment (for i1Pro/i1Pro2/ES-1000/ES-2000) . . . . . . . . . . . . . . . . . 3-50
Added procedures of Density Balance Adjustment
(Registration of color measurement data using a USB memory) . . . . . . . . . . . . . . . . . . . 3-59
Maximum Density Auto Adjustment (RU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-61
Check setting of Color Density Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-63
Color Density Manual Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-66
Controller Calibration (IC-308/IC-310) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-68

iii
1 DAILY CARE
About daily care

To reproduce stable output by this machine, be sure to clean the machine before output.

)Cleaning timing
Check the cleaning section every day before you activate the power of the machine.
Clean the cleaning section when the cleaning section is dirty.

Cleaning section Reference


Duplex section P.1-2
Centering sensor (Paper feeder unit PF-707/PF-708) P.1-6
Roller of the humidification section (Relay conveyance unit RU-511) P.1-7

1-1
bizhub PRESS C1100/C1085

Cleaning the duplex section

CAUTION
Be sure to check the cleaning section before you activate the power of the main body.
If you activate the power with closed the door of the main body, the inside of the fusing unit becomes hot. Therefore,
you possibly get burned when you clean near the fusing unit.

)Cleaning section of the duplex section


- Upper side of the duplex section
- Paper path of the registration unit
- Pre-fusing guide plate
- Fusing unit entrance guide
- Paper path of the duplex unit
- Paper path inside the jam processing guide

NOTICE
- Be careful not to drop any dirt inside the machine when you clean the machine.

)Cleaning procedure

1 Open the right door and the left door of


the main body.

2 Activate the main power switch, then activate the sub power switch.

1-2
3 Tilt the lever [M1] counterclockwise.

4 Hold the lever [M1], and pull out the


duplex section.

5 Deactivate the sub power switch, then deactivate the main power switch.

6 Wipe off the dirt at the upper side of the


duplex section with a hydro-wipe (non-
woven fabric without fluff).
NOTICE
- Do not use alcohol when you clean the upper side of
the duplex section.
- Be sure to clean the duplex section in an axial
direction. If you clean the unit in the paper feed
direction, toner drops on the paper path.

NOTICE
- Be sure to clean the duplex section so that the sheet
at the upper side of the duplex section does not
deform.

1-3
bizhub PRESS C1100/C1085

7 Open the cover [M3].

8 Wipe off the dirt at the paper path of the


registration unit with a hydro-wipe (non-
woven fabric without fluff).

9 Close the cover [M3].

10 Wipe off the dirt at the pre-fusing guide


plate with a hydro-wipe (non-woven
fabric without fluff).
NOTICE
- Do not use alcohol when you clean the pre-fusing
guide plate.

NOTICE
- Be careful not to deform the sheet ( ) at the
entrance of the fusing unit when you clean the pre-
fusing guide plate.

1-4
11 Moisten the hydro-wipe (non-woven
fabric without fluff) with isopropyl
alcohol, and clean the dirt of the fusing
unit entrance guide.

12 Hold the lever [M8], and open the paper


path of the duplex unit.

13 Moisten the hydro-wipe (non-woven


fabric without fluff) with isopropyl
alcohol, and clean the dirt of the paper
path of the duplex unit.

14 Hold the lever [M9] and open the jam


processing guide. Then, moisten the
hydro-wipe (non-woven fabric without
fluff) with isopropyl alcohol, and clean the
dirt of the paper path inside the guide.

15 Close the jam processing guide, and close the duplex unit.
16 Push the duplex section into the main body, and move the lever [M1] to the initial
position.

17 Close the left door and the right door of the main body

1-5
bizhub PRESS C1100/C1085

Cleaning the centering sensor (Paper feeder unit PF-707/PF-708)

1 Open the front door of the paper feeder


unit.

2 Open the cover [PF4].

3 Clean the centering sensor with a


cleaning pad.
NOTICE
- Do not use alcohol when you clean the sensor. The
surface of the sensor becomes fuzzy.
1

NOTICE
- Do not touch the positioning pin ( ) with the
cleaning pad since there is grease on the pin.

4 Close the cover [PF4]

5 Close the front door of the paper feeder unit.

1-6
Cleaning the roller of the humidification section
(Relay conveyance unit RU-511)

1 Open the front door of the relay


conveyance unit.

2 Hold the handle [HM1], and pull out the


humidification unit.

3 Hold the lever [HM2], and open the paper


path.

4 Moisten the cleaning pad with isopropyl


alcohol, and clean the roller.

5 Hold the handle [HM1], and move the humidification unit to the initial position.

6 Close the front door of the relay conveyance unit.

1-7
bizhub PRESS C1100/C1085

2 BOTH SIDES ADJUSTMENT


About both sides adjustment

To maintain stable both sides accuracy against a change in ambient temperature or humidity, a change of this machine
conditions, or a change of the both sides accuracy due to the paper type, perform the both sides adjustment at
periodic intervals.
After you understand the both sides adjustment flow (timing, method, and order), perform the necessary adjustment.
There are three types of both sides adjustment flows as follows.

Type of adjustment flow Adjustment timing


Adjustment flow when using a When you use a new paper brand, a new paper weight, or a new paper size
new paper brand, a new paper
weight, or a new paper size
Regular adjustment flow When you change the brand, weight, or size of the paper inside the tray
Adjustment flow for each job • Before you output a job that the both sides accuracy is important
• Before you output a job that the printing area is large
• When you are not satisfied with the both sides accuracy (when you want to
raise the both sides accuracy)

Adjustment flow
when using a new paper brand, a new paper weight, or a new paper size

)Adjustment timing
- When you use a new paper brand, a new paper weight, or a new paper size

)Adjustment order
Order Adjustment item Reference
1 Placing paper P.2-3 2
2 Front side adjustment P.2-6
P.2-11
(When not using
PF-708 scanner)
3 "Gap adjustment" or "Scan measurement adjustment"
P.2-16
(When using PF-
708 scanner)
4 Registering the paper profile P.2-24

Reference
For details of each adjustment item, refer to "Contents of both sides adjustment items" (Page 2-3).

2-1
Regular adjustment flow

)Adjustment timing
- When you change the brand, weight, or size of the paper inside the tray

NOTICE
When you have not changed the paper inside the tray for more than one day, perform the adjustment before you output
the job (before the adjustment flow for each job).

)Adjustment order
Order Adjustment item Reference
1 Placing paper P.2-3
2 Front side adjustment P.2-6
P.2-11
(When not using
PF-708 scanner)
3 "Gap adjustment" or "Scan measurement adjustment"
P.2-16
(When using PF-
708 scanner)

Reference
For details of each adjustment item, refer to "Contents of both sides adjustment items" (Page 2-3).

Adjustment flow for each job

)Adjustment timing
- Before you output a job that the both sides accuracy is important
- Before you output a job that the printing area is large
- When you are not satisfied with the both sides accuracy (when you want to raise the both sides accuracy)

)Adjustment order
Order Adjustment item Reference
1 Back side fine adjustment P.2-26

Reference
For details of each adjustment item, refer to "Contents of both sides adjustment items" (Page 2-3).

2-2
bizhub PRESS C1100/C1085

Contents of both sides adjustment items

This section describes the contents of the following six adjustment items.
- Placing paper (Page 2-3)
- Front side adjustment (Page 2-6)
- Gap adjustment (When not using PF-708 scanner) (Page 2-11)
- Scan measurement adjustment (When using PF-708 Scanner) (Page 2-16)
- Registering the paper profile (Page 2-24)
- Back side fine adjustment (Page 2-26)

)Placing paper

1 Pull out the tray to load paper into.


NOTICE
Trays can be pulled out only when this machine is turned
on. Before pulling out the target tray, check that the sub
power switch is turned on.

2 Turn the side guide lock knobs (2 pieces)


counterclockwise to loosen them.

3 Widen the side guide plates on both


sides with pressing the side guide lock
release lever ( ).
NOTICE
To slide the side guide plates, be sure to hold both side
guide plates together. If you move it by holding only either
of the side guide plate, the side guide plate that is held
may become displaced. 2

4 Widen the rear guide plates on both


sides with pressing the rear guide lock
release lever.

5 Load an appropriate amount of paper into the tray while aligning it to the left-hand side
of the tray.
NOTICE
Load paper with the print side facing up.

2-3
6 Slide the side guide plates on both sides, and press the side guide plates against the
paper.

7 Turn the bottom plate fixing knob


counterclockwise to loosen it, slide it to
the front, and turn it clockwise to fix the
plate.

8 Return the tray to its original position, then withdraw it again after the bottom plate of
the tray goes up completely.
The sound of motor elevating the bottom plate can be heard when the tray is returned in position. After
that automation is completed, again withdraw the tray to find that the bottom plate has been elevated to
the top position.

NOTICE
- Be sure not to withdraw the tray till the motor sound stops. Otherwise, the later operation may be affected
because the bottom plate is not elevated completely to the top.
- Adjust so that the scale marks of the front side and the back side become the same value.

9 Fix the position of the top edges of the


side guide plates.
Move top edges of the side guide plates to align
them to the paper, then turn the two side guide
fixing knobs clockwise to fix the guides.

NOTICE
- Avoid making the space between the side guide
plates too wide or too narrow for the paper to be
seated straight.
- Adjust so that the scale marks of the front side and
the back side become the same value.

2-4
bizhub PRESS C1100/C1085

10 Lower the bottom plate of the tray.


Turn the bottom plate fixing knob
counterclockwise to loosen it, slide it to the back,
and turn it clockwise to fix the plate. The bottom
plate automatically goes down.

11 Load the remaining paper into the tray,


then press the rear guide plate against
the paper.
NOTICE
Be careful not to load paper above the , mark that
indicates the height limit on the side guide plate.
Otherwise, a paper jam may occur.
Load paper with the print side facing up.

12 Close the tray.


Push the tray in until it locks into place.

2-5
)Front side adjustment

1 Press [Paper Setting] on the [MACHINE]


screen.

2 Press the tray with the target paper


loaded.

3 Press [Recall].

2-6
bizhub PRESS C1100/C1085

4 Select the paper profile of the same


paper brand (paper profile name), "Paper
size", "Type of paper" and "Paper
weight" as the paper that you want to
adjust. Then, select [OK].
When there is no paper profile to select, select
[Cancel].
Tips
When the paper profile has a different "Paper size" or "Set
direction" information to the paper that is loaded, the
paper profile is gray out. Therefore, the profile cannot be
selected.

5 Press [Change Set].

6 Press [Both Sides Adj.]

7 Select [Front], then press [Chart


Adjustment].

2-7
8 Press [Print Mode].

9 When the [PRINT MODE] screen is


displayed, press Start on the control
panel.
A test chart is printed out.
NOTICE
Output about 3 sheets.

10 Press [Exit Print Mode].

2-8
bizhub PRESS C1100/C1085

11 Check the length of [2], [4], [6], and [8] of


the charts that are output as the second
and third sheet.
[5]
Write down the measured lengths so that you do [1]
not forget them.
When the length of [2], [4], [6], and [8] is within the
following range, press [Close] and then press [OK]
to exit the adjustment.
When the length of [2], [4], [6], and [8] is out of the
[5] [7]
following range, measure [1], [3], [5], and [7], and [1] [2]

go to the next step.


[2]: 200mm±0.3mm
[4]: 200mm±0.3mm
[6]: 200mm±0.3mm [6] [8]

[8]: 200mm±0.3mm

[3] [4]

12 Press each point number, then enter the


measured length using the keypad on the
screen.
To reset a value, press [Clear].

13 When entry processing is completed,


press [Adjustment Start]. 2

2-9
14 Output the front side adjustment chart again, and check the length of [2], [4], [6], and
[8] of the charts that are output as the second and third sheet.
Repeat from step 11 to step 14 until the length of [2], [4], [6], and [8] are within the range of the following
values.
[2]: 200mm±0.3mm
[4]: 200mm±0.3mm
[6]: 200mm±0.3mm
[8]: 200mm±0.3mm

15 Press [OK] to exit the adjustment.

2-10
bizhub PRESS C1100/C1085

)Gap adjustment (When not using PF-708 scanner)

NOTICE
The Gap Adjustment is a simple method to adjust only the zoom ratio and image position of the back side. To also
adjust it on the front side, carry out "Front Side Adjustment" (Page 2-6) .

1 Press [Paper Setting] on the [MACHINE]


screen.

2 Press the tray that you conducted "Front


Side Adjustment".

3 Press [Change Set].


2

2-11
4 Press [Both Sides Adj.].

5 Press [Print Mode].

6 When the [PRINT MODE] screen is


displayed, press Start on the control
panel.
A test chart is printed out.
NOTICE
Output about 3 sheets.

7 Press [Exit Print Mode].

2-12
bizhub PRESS C1100/C1085

8 Measure the back side image difference


at each point from [a] to [d] that is
positioned at the [back] side of the >D@
second and third output charts.
- The scale resolution is 0.5 mm. EDFN
- The black line in the figure shows the back
side, and the blue dashed line shows the
other side (front side).
- The measurement value can be entered in
units of up to 0.1 mm. 
- For example, as this figure shows, when the \
black line at the back side is shifted by 1.5  [ 
mm to the plus direction than the blue dashed 
line at the front side, input -1.5 and correct the
difference. Then, the black line at the back
side 1.5 mm is moved to the minus direction.
- Write down the measured values so that you
do not forget them.

2-13
9 Press [a] to [d] of each point, and enter
the adjustment value using the keypad,
[,], or [+] on the screen.

10 When entry processing is completed,


press [Adjustment Start].
The input adjustment value is reflected to the
"Zoom" value and the "Image Shift" value at the
[Back] screen.
When [User Setting] - [Common Setting] - [Back
Side Magnification Adjustment] - is configured to
[OFF], the adjustment value is not reflected to
[Horizontal] at the [Back] screen.

11 Press Start on the control panel.


A test chart is printed out.
NOTICE
Output about 3 charts.

12 Check the gap of the printing position referring to the charts that are output as the
second and third sheet.
Repeat steps 10 to 13 until all gaps between the front and back sides are cleared.

2-14
bizhub PRESS C1100/C1085

13 Press [Exit Print Mode].

14 Press [OK] to exit the adjustment.

2-15
)Scan measurement adjustment (When using PF-708 Scanner)
Adjust the magnification ratio and printing position of the back side with reference to the printing position of the front
side. The magnification ratio and printing position of the back side are automatically adjusted by using the scanner
function of this machine to measure the gap amount in printing position of the back side to the front side. You do not
need to measure the gap amount with a scale. The adjustment is available for paper of all sizes which can be used
with this machine.
Print out 1 to 20 sheets of the adjustment chart having both front and back sides printed, and scan them 4 times per
sheet. The average value of gap amounts in printing position of the back side to the front side, which can be obtained
by scanning up to 20 sheets of the adjustment chart, will be calculated in order to adjust the magnification ratio and
printing position of the back side.

NOTICE
The [Scan Meas.] adjustment provides the coordination based on the average value of gap amounts, taking into
account the gap in printing position between the first and last sheets which can be produced when multiple sheets are
output.
Performing the [Scan Meas.] adjustment may require readjustment of the "Zoom and Image Shift Adjustment"
registered in a paper profile.
The [Scan Meas.] adjustment is a simple method to adjust only the magnification ratio and image position of the back
side. To adjust both front and back sides, perform the "Front side Adjustment" (Page 2-6).

1 Press [Paper Setting] on the [MACHINE]


screen.

2 Select the tray with the target paper


loaded, then press [Change Set].

2-16
bizhub PRESS C1100/C1085

3 Press [Both Sides Adj].

4 Check that [Scan Meas.] is displayed,


then press [Output Background Sheet].

5 When the [PRINT MODE] screen is


displayed, press Start on the control
panel.
A background sheet is printed out. If you already
have the background sheet available for
measurement, you do not need to print out a
background sheet. Proceed to Step 7.
NOTICE 2
Use paper of A3 or larger, or 11 e 17 or larger to output
the background sheet. When you press [Output
Background Sheet] to display the PRINT MODE Screen
for the background sheet, the tray selected in step 2 is
automatically selected on the screen, but it can be
changed as desired. Select a tray loaded with A3 or larger,
or 11 e 17 or larger paper. You can also change the print
count, but only one sheet is needed. If the background
sheet size is smaller than A3 or 11 e 17, the scan
measurement may not be performed.

2-17
6 Press [Exit Print Mode].

7 Press [1. Output Adjustment Chart].

8 Enter the number of adjustment charts


you want to print out.
however, only up to 20 adjustment charts can be
scan-measured continuously.

9 Press Start on the control panel.


Adjustment charts are printed on both sides of the
paper in the tray you selected in Step 2.

2-18
bizhub PRESS C1100/C1085

10 Press [Exit Print Mode].

11 Press [2. Scan Adjustment Chart].


The [Scan Adjustment Chart] screen is displayed.

12 Place an adjustment chart on the original glass.


Open the ADF, then place an adjustment chart with the front side facing up (not facing the original
glass), setting the top side flush with the far end of the glass. Place the upper-left corner of the
adjustment chart approximately 2 inches (approximately 5 cm) away from the vertical size guide and
horizontal size guide respectively on the original glass making sure that the left and top sides are
parallel to the vertical size guide and horizontal size guide respectively.

2-19
13 Place the background sheet on the original glass, then close the ADF.
Place the black side of the background sheet facing down (facing the original glass), then set it flush
with the vertical size guide and horizontal size guide as shown below. Exercise care to ensure the
previously set adjustment chart is not misaligned.

14 Press [Start] on the [Scan Adjustment


Chart] screen.
The adjustment chart is scanned.

When scanning is properly completed, the


counter of [Number of Scanning] on the Scan
Adjustment Chart screen is added by one, and
the blue frame displayed in the illustration on
the screen shifts to the next one on the right
side.
- If you move the adjustment chart before the
blue frame shifts to the next, the
measurement may not be performed
properly.
- If the ADF is open, scanning fails, and a
message is displayed. Close the ADF, then
press [Close] in the message dialog box.
- If scanning fails, a message may be
displayed. Follow the on-screen instructions
to correctly place the adjustment chart and
background sheet, then press [Close].
- If you press [Return] on the Scan Adjustment
Chart screen during scan measurement, a
message is displayed to confirm whether to
interrupt the scan measurement. To discard
the previous measurement result, press [Yes].
Retry the scanning process from the first scan
measurement. When continuing scan measurement, press [No].

2-20
bizhub PRESS C1100/C1085

15 Repeat the scanning steps 12 to 14 four times for every adjustment chart.
- First time: Set the front side of the adjustment
chart face up (turned away from the original
glass), with its top edge positioned to the
back side.

- Second time: Set the front side of the


adjustment chart face up (turned away from
the original glass), with its bottom edge
positioned to the back side.

- Third time: Set the back side of the


adjustment chart face up (turned away from
the original glass), with its top edge
positioned to the back side.

- Fourth time: Set the back side of the


adjustment chart face up (turned away from
the original glass), with its bottom edge
positioned to the back side.
When four times of scanning are completed, a
dialog is displayed to calculate the adjustment
value.

2-21
16 Select whether to continue the scan
measurement or to finish the scan
measurement and calculate the
adjustment value.
- To continue the scan measurement, press
[No]. To finish the scan measurement and
calculate the adjustment value, press [Yes].
- Pressing [No] returns to the [Scan Adjustment
Chart] screen on which the counter of [Chart
Sheets] is added by one. Repeat steps 12 to
15 for the number of adjustment charts. The
measurement results will be added up. This
operation can be repeated up to 20 times.
When the 20th scan measurement is
completed, [No] can no longer be pressed.
- Pressing [Yes] automatically calculates the
adjustment value from the added
measurement results and reflects it on Zoom
and Image Shift to be specified for [Back].
After pressing [Yes], output a sheet of the
adjustment chart to confirm the result. If
readjustment is needed, repeat steps 8 to 16.
- If the adjustment value obtained by pressing
[Yes] exceeds the available adjustment range,
a message is displayed indicating that the
available adjustment range has been
exceeded. Press [Close] to discard the
adjustment value, then retry scan
measurement from the beginning.
- Possible causes to exceed the adjustment
range may include that the chart used in the
scan measurement is incorrect (a different
chart has been used), the printing position of
the front side has been poorly adjusted, or the
adjustments of the reference positions are not
completed. Confirm these points before
restarting the scan measurement.

17 After the adjustment is completed, press


[OK].
To finely adjust the adjustment value, continuously
proceed to step 4 in "Back side fine Adjustment"
(Page 2-26).

2-22
bizhub PRESS C1100/C1085

18 Press [Close] to exit the adjustment.


Scan Measurement Adjustment is then
completed.
- To register adjustment values in a paper
profile, press [Register].

2-23
)Registering the paper profile

1 Press [Register].

2 Press the number which you register a


new paper profile.

3 Enter the paper profile name and press


[OK].
Enter the paper brand name in paper profile
name.

4 Check that the paper profile has been


registered and press [Close].

2-24
bizhub PRESS C1100/C1085

5 Press [Close] to exit the registration.


Tips
Use the registered paper profile when you carry out
"Regular adjustment flow".

2-25
)Back side fine adjustment
This adjustment is useful when the magnification of the back side image and the image position are adjusted according
to the output result of the actual job data.

1 Output about 3 sheets of the actual job data that you use from the tray that you
conducted "Both Side Adjustment".

2 Press [Paper Setting] on the [MACHINE]


screen.

3 Select the tray that you output the job


data, then press [Change Set].

4 Press [Both Sides Adj.].

2-26
bizhub PRESS C1100/C1085

5 Press [Back].

6 Check the back side magnification


difference from the back side images
that are output as the second and third
sheet among the output jobs in step 1.
back
Pile the output jobs so that the front side of one
sheet faces up, and the back side of another sheet
faces up. Compare the image interval of the front
side and the image interval of the back side.
When the image interval of the front side is back
different from the image interval of the back side,
enter the adjustment value in [Vertical] (crosswise
direction) and [Horizontal] (paper feed direction) at
the [back] screen.
front
Example of adjusting the image magnification:
If the image interval on the front side is 400 mm,
and the image interval on the back side is 401 mm,
enter [-0.25 %] in the adjustment value.
NOTICE
When you invert the paper, be sure that the crosswise
direction becomes the rotation axis.

Tips
The adjustment value changes 0.01% on a 1-step basis. 2
Adjustment Range: [Vertical] –1.00 to +1.00, [Horizontal] –
0.80 to +0.20
When [User Setting] - [Common Setting] - [Back Side
Magnification Adjustment] - is configured to [OFF],
[Horizontal] cannot be configured.

7 After the adjustment is completed, press


[OK].

2-27
8 Output about 3 sheets of the same job data that you output in step 1 from the same tray.

9 Check the magnification difference of the back side of the paper that are output as the
second and third sheet.
Repeat from step 6 to step 8 until all magnification difference are cleared.

10 Press [Paper Setting] on the [MACHINE]


screen.

11 Select the tray with the target paper


loaded, then press [Change Set].

12 Press [Both Sides Adj.].

2-28
bizhub PRESS C1100/C1085

13 Check the position difference of the back


side among the back side images of the +
second and third output that were output
after the magnification adjustment is
completed.
The black line in the figure shows the back side, - +
and the blue dashed line shows the other side
(front side).
When the position of the front side image and the
back side image differs, input the adjustment
value in [Up/Down] (crosswise direction) and
-
[Right/Left] (paper feed direction).
To move the image up or to the right, enter the
value with a positive mark (+). To move the image
back
down or to the left, enter the value with a negative
mark (–).
Example of adjusting the image position:
When the back side is misaligned to the front side
by 0.5 mm down and 0.3 mm to the right, enter
[+0.5 mm] in [Up/Down], and [-0.3 mm] in
[Right/Left].
Tips
The adjustment value changes 0.1 mm on a 1-step basis.
Adjustment range: [Up/Down] –10.0 to +10.0, [Right/Left]
–3.0 to +3.0

14 After the adjustment is completed, press


[OK].

15 Output about 3 sheets of the same job data that you output in step 1 from the same
tray.

16 Check the image position difference of the back side of the jobs that are output as the
second and third sheet.
Repeat from step 13 to step 15 until all image position difference are cleared.
When all image position difference are cleared, exit the adjustment.

2-29
3 IMAGE QUALITY ADJUSTMENT

3.1 Image quality adjustment for Image Controller IC-602

About Quality Adjustment

To maintain stable color quality against a change in ambient temperature or humidity, a change of this machine
conditions, or a change of the color tone due to the paper type or print mode, perform the image quality adjustment
at periodic intervals.
After you understand the image quality adjustment flow (timing, method, and order), perform a necessary adjustment.
When the image controller IC-602 is installed to this machine, there are two types of image quality adjustment flows
as follows.

Type of adjustment flow Adjustment timing Required time


Regular adjustment flow (High • Every day, when you activate the power of the ma- Approximately
accuracy) chine (when you require a high accuracy color repro- 4 minutes
duction)
• Before you output a job that the color is important
• When you are not satisfied with the color stability
(want to improve the reproducibility)
Adjustment flow when changing • When you change the setting of Custom Screen Approximately
the screen 38 minutes

NOTICE
On this machine, when you configure the color density control to automatic, the regular adjustment flow (standard) is
processed automatically. Before you use the machine, check the configuration of color density control.
For details of the procedures to check the configuration, refer to P.3-28.

3-1
bizhub PRESS C1100/C1085

Regular adjustment flow (High accuracy)

)Adjustment timing
For customers that require a high accuracy color reproduction, conduct the process when you activate the power
every day.
For other cases, conduct the process in the following cases.
- Before you output a job that the color is important
- When you are not satisfied with the color stability (want to improve the reproducibility)

)Adjustment order

Order Adjustment item Required time Reference


1 Gamma Automatic Adjustment Approximately P.3-6
1 minute
2 Maximum Density Auto Adjustment (RU) Approximately P.3-26
3 minutes

Reference
For details of each adjustment item, refer to "Contents of the image quality adjustment items" (Page 3-4).

3-2
Adjustment flow when changing the screen

)Adjustment timing
- When you change the setting of Custom Screen

)Adjustment order
Order Adjustment item Required time Reference
Approximately
1 Change setting of Custom Screen P.3-4
1 minute
Approximately
2 Gamma Automatic Adjustment P.3-6
1 minute
P.3-7
(for
Approximately i1Pro/i1Pro2/ES-
3 Density Balance Adjustment * 1000/ES-2000)
10 minutes
P.3-16
(for FD-5BT)
Approximately
4 Color Density Manual Control P.3-31
1 minute
P.3-33
Approximately (Exact Color)
5 "Exact Color" or "G7 Calibration"
25 minutes P.3-39
(G7 Calibration)

* When the changed Custom Screen is [Stochastic], Density balance adjustment is not required.

Tips
- If you interrupted the operation during the adjustment flow, be sure to perform Gamma Automatic Adjustment
before the rest of adjustment flow.
- The default setting of Color Centro is "Exact Color". When you want to change to "G7 Calibration", contact your
service representative. When you want to return "G7 Calibration" to "Exact Color", also contact your service
representative.
Reference
For details of each adjustment item, refer to "Contents of the image quality adjustment items" (Page 3-4).

3-3
bizhub PRESS C1100/C1085

Contents of the image quality adjustment items

This section describes the contents of the following 10 adjustment items.


- Change setting of Custom Screen (Page 3-4)
- Gamma Automatic Adjustment (Page 3-6)
- Density Balance Adjustment (for i1Pro/i1Pro2/ES-1000/ES-2000) (Page 3-7)
- Density Balance Adjustment (for FD-5BT) (Page 3-16)
- Added procedures of Density Balance Adjustment (Registration of color measurement data using a USB
memory) (Page 3-24)
- Maximum Density Auto Adjustment (RU) (Page 3-26)
- Check setting of Color Density Control (Page 3-28)
- Color Density Manual Control (Page 3-31)
- Exact Color (for i1Pro/i1Pro2/ES-1000/ES-2000, or FD-5BT) (Page 3-33)
- G7 Calibration (for i1Pro/i1Pro2/ES-1000/ES-2000, or FD-5BT) (Page 3-39)

)Change setting of Custom Screen

1 Press Utility/Counter on the machine's


control panel.

2 Press [Administrator Setting].


Tips
To enter [Administrator Setting], the administrator
privilege may be required. Contact your machine
administrator. 3

3-4
3 Press [System Setting] on the
[Administrator Setting Menu] screen, and
then press [Expert Adjustment], [Quality
Adjustment], and [Custom Screen] in
sequence.

4 Press the screen to be assigned to each


screen type: [Screen 1], [Screen 2], and
[Stochastic]. After setting, press [OK].
NOTICE
[Dot190] is recommended as the configuration for [Screen
1].

3-5
bizhub PRESS C1100/C1085

)Gamma Automatic Adjustment

1 On the touch panel of the main body,


press [Adjustment] on the [MACHINE]
screen.

2 Press [Execute Adjust Operation] on the


[Adjustment Menu] screen.

3 Press [Gamma Automatic Adj.] and press


[OK].

4 Press [Exit [ADJUSTMENT]].


Wait for the display "Now adjusting" to disappear.

3-6
)Density Balance Adjustment (for i1Pro/i1Pro2/ES-1000/ES-2000)

NOTICE
To measure the chart, use the X-rite Measure tool. Install the tool in advance.
You can download the X-rite Measure tool at the following Web site. After installing the tool, restart the computer.
ProfileMaker 5 v5.0.10:
http://www.xrite.com/product_overview.aspx?ID=757&Action=Support

1 On the touch panel of the main body,


press [Adjustment] on the [MACHINE]
screen.

2 Press [Density Balance Adjustment] on


the [Adjustment Menu] screen.

3 Press [Density Balance Chart Output].

3-7
bizhub PRESS C1100/C1085

4 Select the desired chart type from


"Measure Spectrophotometer-2", and
press [Print Mode].
[Type2] is recommended.

5 Press [Quality Adj.].

6 Press [Screen Pattern] and select the


screen that is changed at "Change
setting of Custom Screen" in the
adjustment items (screen for Density
balance adjustment) .
Tips
[Stochastic] is unavailable.

3
7 Select paper for chart output.
Tips
Load 12 e 18 w, SRA3 w, 11 e 17 w, or A3 w paper in a
tray, then select that tray.
Load the paper of paper type and weight that you want to
register on the density balance adjustment data into the
target tray.
This machine selects the density balance adjustment data
to apply a job in accordance with the following priority.
Priority 1: Screen > Priority 2: Paper Type > Priority 3:
Weight > Priority 4: Registered Order
(If there is no density balance adjustment data for the
screen that corresponds to a job, the job is output without
correcting its density balance.)

3-8
8 Press Start on the control panel.
The color chart is output for measurement using
the spectrophotometer.

9 Press [Exit PrintMode].

10 Press [Return], and return to the [Density


Balance Adjustment Menu] screen.

11 On the computer where the X-rite Measure tool. l has been installed, select [Start] -
[All Programs] - [X-Rite] - [ProfileMaker Pro 5.0.10] - [MeasureTool].

12 When the following message is


displayed, click [OK].

3-9
bizhub PRESS C1100/C1085

13 Connect the instrument to the computer.


From the menu, click [Configuring].

14 In [Instrument], select [Eye-One Pro].


When [OK] is displayed, close the
screen.

15 From the menu, click [Measuring].

3-10
16 From [Test Chart], select [Custom].

17 Specify [Columns] and [Rows], and click


[OK].
- When the chart type is "Type 1":
[Columns] = 6, [Rows] = 5
- When the chart type is "Type 2":
[Columns] = 6, [Rows] = 13

18 Click [Start].

19 When the following message is displayed, horizontally place the spectrophotometer


on the calibration dock and click [OK].

3-11
bizhub PRESS C1100/C1085

20 Stack 10 sheets of blank paper whose type is the same as that of the paper where
chart has been printed, and place the printed chart on top of it.

21 When the following screen is displayed,


place the spectrophotometer on the
patch at the top in the upper left, and
press the button for the
spectrophotometer. When beep sounds,
check that the read patch is displayed on
the screen.
Tips
For i1Pro2/ES-2000, install the positioning target to the
spectrophotometer before you measure the color.

22 Continuously, place the


spectrophotometer on the next right
patch, and press the button for the
spectrophotometer. Measure all the
patches in the same operation.
If you place the spectrophotometer on the wrong
place (patch), click the button to go back to
the previous patch position.
The white portion where it is displayed that
nothing is printed is also part of the patch. Do not
forget to measure it. If not measured, an error will
occur.

23 When you are finished with the chart


measurement, click [Close].

3-12
24 From the [File] menu, select [Save As].
NOTICE
If you use [Export Lab], an error occurs when registering
the color adjustment data. When saving the data, always
use [Save As].

25 Specify the destination to save.


Specify USB memory or the computer connected to the machine via the network.

Destination to save Description


USB Memory Connect the USB memory to the computer.
Create a folder, "\C1100\ADJUST_DATA," in the root (immediately be-
low) of the USB memory, and specify the place as the destination to
save.
Computer on the network Open the computer connected to the network used by the machine, and
specify a desired folder.

26 Enter the file name to save the measured


data and click [Save].
Specify the "14-character identification number
printed on the chart" + "_" (underscore) +
"character string of up to 21 characters."
Example: 30255160110D27_2014-07-25.txt
Reference
When you save in a USB memory, go to "Added
procedures of Density Balance Adjustment (Registration
of color measurement data using a USB memory)" (Page
3-24).

27 On the computer on the network where the measured data has been saved, open a
Web browser.

28 In the URL field, enter "http://IP address


of the machine (or the host name):30091"
and press the Enter key.
If the controller of EFI is implemented, ":30091" at
the end of the IP address is unnecessary.

3-13
bizhub PRESS C1100/C1085

29 Click [Machine Manager Setting], and


enter the administrator ID and password.
Tips
Contact your machine administrator for the administrator
ID and the password.

30 Click on [Color Measuring data Input].

31 Enter the file name for colorimetric data


into [File Name], click [Browse] on the
side of the file path, and select the
colorimetric data saved in the computer.

32 Click [Upload].
Colorimetric data is saved in the machine.

33 Press [Density Balance Data Reg/Del] on 3


the [Density Balance Adjustment Menu]
screen to display the [Density Balance
Adj. Data Register/Del] screen.

3-14
34 Select any one row in the list of 10
profiles, and press [Archived Data].
NOTICE
- No more than 10 pieces of data can be registered,
however, the data can be overwritten. If desired,
select the data to be overwritten.
- The colorimetric data can be synthesized and
registered. To synthesize data, select the row having
the same screen type, paper type, and weight.

35 Select the file name of the data to be


registered, then press [OK].

Tips
With a row of the existing data selected in step 34, a
confirmation dialog is displayed.
To synthesize the selected data with the new data, press
[Combination]. If conditions for screen type, paper type,
or weight do not correspond to each other, [Combination]
dims.

36 When the following screen is displayed,


press [OK].

3-15
bizhub PRESS C1100/C1085

)Density Balance Adjustment (for FD-5BT)

NOTICE
To measure the chart, use the Color Care measure. Install the Color Care measure in advance.
To use Color Care measure, you need to acquire a license key. For details, refer to the user's guide that comes with
Color Care measure.

1 On the touch panel of the main body,


press [Adjustment] on the [MACHINE]
screen.

2 Press [Density Balance Adjustment] on


the [Adjustment Menu] screen.

3 Press [Density Balance Chart Output].

3-16
4 Select the [Type3] of "Measure
Spectrophotometer-3", and press [Print
Mode].

5 Press [Quality Adj.].

6 Press [Screen Pattern] and select the


screen that is changed at "Change
setting of Custom Screen" in the
adjustment items (screen for Density
balance adjustment) .
Tips
[Stochastic] is unavailable.

7 Select paper for chart output.


Tips
Load 12 e 18 w, SRA3 w, 11 e 17 w, or A3 w paper in a
tray, then select that tray.
Load the paper of paper type and weight that you want to
register on the density balance adjustment data into the
target tray.
This machine selects the density balance adjustment data
to apply a job in accordance with the following priority.
Priority 1: Screen > Priority 2: Paper Type > Priority 3:
Weight > Priority 4: Registered Order
(If there is no density balance adjustment data for the
screen that corresponds to a job, the job is output without
correcting its density balance.)

3-17
bizhub PRESS C1100/C1085

8 Press Start on the control panel.


The color chart is output for measurement using
the spectrophotometer.

9 Press [Exit PrintMode].

10 Press [Return], and return to the [Density


Balance Adjustment Menu] screen.

3
11 On the computer where the Color Care measure. l has been installed, select [Start] -
[All Programs] - [Konica Minolta Color Care] - [Color Care measure].

12 Connect FD-5BT to the computer, and


activate the power of FD-5BT.

3-18
13 Click [Color Care - Job 0 - C1070 C1100
- density balance]. Then, click [FD5bt -
Denbal Type 2sr - 13×6], and click [OK].
If the number of the color patch is 13 x 7, select
[FD5bt - Denbal Type 2sr - 13x7].

14 When the following message appears,


place the FD-5BT on the white
calibration plate, and press the FD-5BT.

15 When the following message is


displayed, click [OK].

16 Stack 10 sheets of blank paper whose


type is the same as that of the paper
where chart has been printed, and place
the printed chart on top of it.
Make sure that the arrow of the chart points up
when you place the charts.

3-19
bizhub PRESS C1100/C1085

17 Click [A], and measure charts from the


right row (the row which has larger
numbers).
- Hold down the side button of FD-5BT. When
"bleep" sounds, slide FD-5BT while holding
down the side button.
Slide FD-5BT to the bottom side, then release
the side button.
- For details about how to use FD-5BT, refer to
the manual supplied with the
spectrophotometer.

18 Likewise, measure the rest of the rows.


Click the alphabet of the row that you measure
again when you mistake the row (patch) that you
measure.

19 After you finish the chart measurement,


click [Calibration].

3-20
20 Click [Density Balance...].

21 Enter the 14-digit identification number


that is printed to the chart in [Print ID].
Example: 4025513011E66C

22 Enter a filename in [Addendum].

23 Save the measurement data to the USB memory or the machine.


Destination to save Description
USB Memory Connect the USB memory to the computer, and click [Storage location]
and [Select...].
Create a folder, "\C1100\ADJUST_DATA", in the root (immediately be-
low) of the USB memory, and specify the place as the destination to
save.
Finally, click [Send].
Computer on the network Connect the computer to the same network as the machine, and move
on to the next step.

Tips
The administrator password is required when you save to this machine. Contact your machine administrator for
the administrator password.

Reference
When you save in a USB memory, go to "Added procedures of Density Balance Adjustment (Registration of color
measurement data using a USB memory)" (Page 3-24).

3-21
bizhub PRESS C1100/C1085

24 Click [Printer], and click [+].


Tips
If you have added the machine as the destination to save,
select the machine from [Printer].

25 Enter the information of the machine, and


click [Add].
- [Name]: Any name
- [Password]: Administrator password
- [IP Address]: The IP address of the machine
- [Port]: 30091 (when IC-602 is used), 80 (when
EFI controller is used)

26 Click [Send].
Tips
If [Add] has not finished successfully, the lamp remains
red.

27 When the following message appears,


click [OK].
When a message that is not the following appears,
check the information of [Add] again.

28 Press [Density Balance Data Reg/Del] on 3


the [Density Balance Adjustment Menu]
screen to display the [Density Balance
Adj. Data Register/Del] screen.

3-22
29 Select any one row in the list of 10
profiles, and press [Archived Data].
NOTICE
- No more than 10 pieces of data can be registered,
however, the data can be overwritten. If desired,
select the data to be overwritten.
- The colorimetric data can be synthesized and
registered. To synthesize data, select the row having
the same screen type, paper type, and weight.

30 Select the file name of the data to be


registered, then press [OK].

Tips
With a row of the existing data selected in step 29, a
confirmation dialog is displayed.
To synthesize the selected data with the new data, press
[Combination]. If conditions for screen type, paper type,
or weight do not correspond to each other, [Combination]
dims.

31 When the following screen is displayed,


press [OK].

3-23
bizhub PRESS C1100/C1085

)Added procedures of Density Balance Adjustment


(Registration of color measurement data using a USB memory)

1 Press [Density Balance Data Reg/Del] on


the [Density Balance Adjustment Menu]
screen to display the [Density Balance
Adj.

2 Select any one row in the list of 10


profiles, and press [USB Memory].
NOTICE
- No more than 10 pieces of data can be registered,
however, the data can be overwritten. If desired,
select the data to be overwritten.
- The colorimetric data can be synthesized and
registered. To synthesize data, select the row having
the same screen type, paper type, and weight.

3 The following screen is displayed.


Connect the USB memory where the
measured data has been saved to the
main body, and press [OK].

4 Select the file name of the measured


data to be registered and press [OK].
For FD-5BT, the extension is ".fdd".

3-24
Tips
With a row of the existing data selected in step 2, a
confirmation dialog is displayed.
To synthesize the selected data with the new data, press
[Combination]. If conditions for screen type, paper type,
or weight do not correspond to each other, [Combination]
dims.

5 When the following screen is displayed,


press [OK].

3-25
bizhub PRESS C1100/C1085

)Maximum Density Auto Adjustment (RU)

NOTICE
To enable this function, your service representative must specify the target maximum density value (target density) in
advance. For more information, contact your service representative.
Before you carry out Maximum Density Auto Adjustment (RU), check that the configuration of Screen 1 is Dot190. If
Screen 1 is not configured to Dot190, perform "Change setting of Custom Screen" (Page 3-4), and change Screen 1
to Dot190.
Carry out Maximum Density Auto Adjustment (RU) using the paper that is used to register the target maximum density
value (target density).

1 Press [Adjustment] on the [MACHINE]


screen.

2 Press [Max.Density Auto Adj. (RU)].

3 Press [Print Mode].

4 Load the paper that has been used to register the target density into the tray.

3-26
5 Select the tray containing paper, then
press [OK].
The paper profile of the tray is automatically
switched to the paper profile that has been used
to register the target density.

6 Press Start on the control panel.


A chart is printed out, and auto adjustment starts.
Adjustment processing cannot be stopped until all
charts are printed out.

7 When the adjustment is completed, you


automatically return to the [Maximum
Density Auto Adjustment] screen. Check
the adjustment result.
The auto adjustment result is displayed in [Current
Data].

8 Press [Return] to return to the [Process Adjustment Menu] screen.


Note that the tray remains set to the paper profile that has been used to register the target density.

Tips
If [Maximum Density Auto Adjustment] is carried out, the paper profile of the tray that has been used for auto
adjustment is switched to the paper profile that has been used to register the target density , and it is not returned to
the paper profile that has been used before adjustment. After the adjustment is completed, return to the original paper
profile. After completing this adjustment, you can ask your service representative to configure a setting so that the
paper profile automatically returns to that used before adjustment. For more information, contact your service
representative.

3-27
bizhub PRESS C1100/C1085

)Check setting of Color Density Control

1 Press [Adjustment] on the [MACHINE]


screen.

2 Press [Color Density Control].

3 Press [Basic Setting].

4 Check that the [Use Color Density


Control] and [Periodical Adj. Execution]
are configured to [ON].
Tips
[Adjustment Execution Timing] is a configuration for a job
that contains different screens and paper types.
When you want to prior the color unification within 1 job,
select [Before Job Start].
When you want to prior the color unification within
multiple jobs, select [During Job Runs].

3-28
5 Press [Next].

6 Check that the [Switch Color(1st or 2nd)]


is configured to [Precise].
NOTICE
Select [Precise] or [Normal] depending on the situation.
- When you select [Precise], both the 1st color (YMCK)
and the 2nd color (RGB) are corrected.
When you want to prior the quality, select [Precise].
- When you select [Normal], only the 1st color (YMCK)
is corrected. Select [Normal] when you want to
reduce the amount of paper you use for color density
control.

7 Press [OK].

8 Press [Close].

3-29
bizhub PRESS C1100/C1085

9 Press [Exit [ADJUSTMENT]].


Automatic Adjustment is set. A chart is printed out
periodically, and calibration is carried out
automatically.

3-30
)Color Density Manual Control

1 Press [Adjustment] on the [MACHINE]


screen.

2 Press [Color Density Control].

3 Press [Color Density Manual Control].


This function is available only when [Use Color
Density Control] is set to [ON] in [Color Density
Control] - [Basic Setting].

4 Press [Print Mode].

3-31
bizhub PRESS C1100/C1085

5 Press [Quality Adj.].

6 Press of [Screen Pattern] to select


a screen.

7 Press [Close].

3
8 Press Start.
A chart is printed out, and calibration is carried out.

3-32
)Exact Color (for i1Pro/i1Pro2/ES-1000/ES-2000, or FD-5BT)

NOTICE

Color Centro is a Java application. If Java applications are blocked by a firewall, permit network connections for the
Java applications.
To log on, you need the IP address and the port number of the image controller. (Default port number: 30081)
On the control panel, you can check the IP address in [TCP/IP Setting] and the port number in [JSP Setting]. You can
proceed to [TCP/IP Setting] and [JSP Setting] in the following order.
[Administrator Setting] - [Network Setting] - [NIC Setting]
The JSP setting is a setting that relates to a connection with a Java application server.

1 Open the Start menu, and then click [All Programs] - [KONICA MINOLTA] - [Color
Centro] - [KONICA MINOLTA Color Centro].

2 Select the image controller.


If the image controller that you want to connect to
is not displayed, click [Search] to search for it.

3 Click [Connect].
Color Centro starts, and the launcher screen becomes available.

4 Click [Calibration].

5 Select [Instrument] on the [configuration]


menu, then select [i1Pro].
Before you start this procedure, install the device
driver of the spectrophotometer to your computer.
Tips
For i1Pro2, select [i1Pro2(M0)].
For FD-5BT, activate the power of FD-5BT, and select
[FD-5BT(M0)].

3-33
bizhub PRESS C1100/C1085

6 Click [Settings] in [1. Paper Type / Screen


Settings].

7 Set the [Paper Type] and [Screen


Settings] on the [Paper Type/Screen
Settings] screen and click [OK].
Example: Set the [Paper Type] to [Coated GL], and
the [Screen Setting] to [Screen 1] (default).

8 On the [Calibration Manager] screen,


click [Execute Wizard of Exact Color]
under [3. Exact Color].

9 On the [Operation steps] screen, click


[Next]. 3

3-34
10 Click [Print].
Print the color chart that is to be measured using
the instrument.

11 On the [Print Chart] screen, set the


[Copies] and [Paper Tray]. After setting,
click [Print].

12 Click [Start].

3-35
bizhub PRESS C1100/C1085

13 When the following message is displayed, place the instrument flat on the calibration
dock and click [OK].
For FD-5BT, click [OK] while you press down the FD-5BT.

14 Stack 10 sheets of blank paper whose type is the same as that of the paper where
chart has been printed, and place the printed chart on top of it.

15 When the following message is


displayed, click [OK].

16 Carry out the measurement in sequence from row A.


- Hold down the side button of i1Pro/i1Pro2 or FD-5BT. When "bleep" sounds, slide i1Pro/i1Pro2 or
FD-5BT while holding down the side button.
Slide the spectrophotometer to the opposite side, then release the side button.
- For details about how to use i1Pro/i1Pro2 or FD-5BT, refer to the manual supplied with the
spectrophotometer.

Tips
For FD-5BT, use the FD-5BT after you release the lock lever of the target mask and remove the target mask.

3-36
17 Likewise, measure rows B to Q.
The measured parts are color-displayed on the
screen in the same way as for the chart.

18 After you finish the chart measurement,


click [Next].
After the message, [Calculating] is displayed, the
[Operation steps] screen is displayed.

19 Click [Next] and perform the rest of the


measurement by following the
instructions on the screen.
Perform the rest of the measurement with the
same procedures, in order of "2. The 1st
enhancement of a correction table (FB1)", "3. The
2nd enhancement of a correction table (FB2)", "4.
The 3rd enhancement of a correction table (FB3)",
and "5. The accuracy measurement of FB3".

20 After the measurement of the "5. The


accuracy measurement of FB3", click
[OK] on [Operation steps] screen.

3-37
bizhub PRESS C1100/C1085

21 Change the measurement number on the


right side of [Select] and check the ['E
Ave], ['E Max] values, and the ['a] ['b]
graph of the Gray displayed within the
[Gray Step] frame.
As for the Gray, check the information
within the [Gray Step] frame and select
the calibration data that has the smallest
difference from the target. Then click
[Register the selected result.] .
Tips
- When you put a priority on the gray reproducibility of
the low density, check the left half of the ['a] ['b]
graph that is displayed within the [Gray Step] frame.
And select the calibration data that ['a] and ['b]
values are close to "0".
- When you put a priority on the gray reproducibility of
the high density, check the right half of the ['a] ['b]
graph that is displayed within the [Gray Step] frame.
And select the calibration data that ['a] and ['b]
values are close to "0".

22 Click [OK] on the [Information] screen.


The calibration table is registered in the image
controller.

3-38
)G7 Calibration (for i1Pro/i1Pro2/ES-1000/ES-2000, or FD-5BT)

NOTICE

Color Centro is a Java application. If Java applications are blocked by a firewall, permit network connections for the
Java applications.
To log on, you need the IP address and the port number of the image controller. (Default port number: 30081) On the
control panel, you can check the IP address in [TCP/IP Setting] and the port number in [JSP Setting]. You can proceed
to [TCP/IP Setting] and [JSP Setting] in the following order.
[Administrator Setting] - [Network Setting] - [NIC Setting]
The JSP setting is a setting that relates to a connection with a Java application server.
In Color Centro, Exact Color is configured as default. You can use only either Exact Color or G7 calibration. To switch
to G7 calibration, contact your service representative.

1 Open the Start menu, and then click [All Programs] - [KONICA MINOLTA] - [Color
Centro] - [KONICA MINOLTA Color Centro].

2 Select the image controller.


If the image controller that you want to connect to
is not displayed, click [Search] to search for it.

3 Click [Connect].
Color Centro starts, and the launcher screen becomes available.

4 Click [Calibration].

5 Select [Instrument] on the [configuration] menu,


then select [i1Pro].
Before you start this procedure, install the device
driver of the spectrophotometer to your computer.
Tips
For i1Pro2, select [i1Pro2(M1)].
For FD-5BT, activate the power of FD-5BT, and select
[FD-5BT(M1)].

3-39
bizhub PRESS C1100/C1085

6 Click [Settings] in [1. Paper Type / Screen


Settings].

7 Set the [Paper Type] and [Screen


Settings] on the [Paper Type/Screen
Settings] screen and click [OK].
Example: Set the [Paper Type] to [Coated GL], and
the [Screen Setting] to [Screen 1] (default).

8 On the [Calibration Manager] screen,


click [Start G7 Calibration] under [3. G7
Calibration].

9 Click [Print].
3
Print the color chart that is to be measured using
the instrument.

3-40
10 On the [Print Chart] screen, set the
[Copies] and [Paper Tray]. After setting,
click [Print].

11 Click [Start].

12 When the following message is displayed, place the instrument flat on the calibration
dock and click [OK].
For FD-5BT, click [OK] while you press down the FD-5BT.

13 Stack 10 sheets of blank paper whose type is the same as that of the paper where
chart has been printed, and place the printed chart on top of it.

14 When the following message is


displayed, click [OK].

3-41
bizhub PRESS C1100/C1085

15 Carry out the measurement in sequence from the 1st row.


- Hold down the side button of i1Pro/i1Pro2 or FD-5BT. When "bleep" sounds, slide i1Pro/i1Pro2 or
FD-5BT while holding down the side button.
Slide the spectrophotometer to the opposite side, then release the side button.
- For details about how to use i1Pro/i1Pro2 or FD-5BT, refer to the manual supplied with the
spectrophotometer.
Tips
When using i1Pro2, carry out the dualscan when you measure the sheet.

Tips
For FD-5BT, use the FD-5BT after you release the lock lever of the target mask and remove the target mask.

16 Likewise, measure from the 2nd to the


12th rows.
The measured parts are color-displayed on the
screen in the same way as for the chart.

17 After you finish the chart measurement,


click [Register].
3

3-42
18 Click [OK] on the [Information] screen.
The calibration table is registered in the image
controller.

19 On the [Calibration Manager] screen,


click [Accuracy Measurement] under [3.
G7 Calibration].

20 Click [Print].
Print the color chart that is to be measured using
the instrument.

21 Click [Start].

3-43
bizhub PRESS C1100/C1085

22 Measure the chart using the instrument.


After you finish the chart measurement,
click [OK].
NOTICE
When the values of 'Ch and 'E* are not G7 standard as
the result of the accuracy check, the dialogue is
displayed. You can choose to recalculate and register the
calibration table to fit in the target range or register as is
in the dialogue. Conduct the recalculation.
If you recalculate and the values of 'Ch and 'E* are still
not G7 standard, check the following adjustment items.
- Gamma automatic adjustment
- Density balance adjustment
- Maximum Density Auto Adjustment (RU)
- Color density manual control

Tips
The measurement results (Gray Step) are displayed on
[Calibration Manager] screen.
When [Report Print] is clicked, the measurement results
for G7 calibration is printed.

3-44
3.2 Image quality adjustment for Image Controller IC-308/IC-310

About Quality Adjustment

To maintain stable color quality against a change in ambient temperature or humidity, a change of this machine
conditions, or a change of the color tone due to the paper type or print mode, perform the image quality adjustment
at periodic intervals.
After you understand the image quality adjustment flow (timing, method, and order), perform a necessary adjustment.
When the image controller IC-308/IC-310 is installed to this machine, there are two types of image quality adjustment
flows as follows.

Type of adjustment flow Adjustment timing Required time


Regular adjustment flow (High • Every day, When you activate the power of the ma- Approximately
accuracy) chine (when you require a high accuracy color repro- 4 minutes
duction)
• Before you output a job that the color is important
• When you are not satisfied with the color stability
(want to improve the reproducibility)
Adjustment flow when changing • When you change the setting of Custom Screen Approximately
the screen 18 minutes

NOTICE
On this machine, when you configure the color density control to automatic, the regular adjustment flow (standard) is
processed automatically. Before you use the machine, check the configuration of color density control.
For details of the procedures to check the configuration, refer to P.3-63.

Regular adjustment flow (High accuracy)

)Adjustment timing
For customers that require a high accuracy color reproduction, conduct the process when you activate the power
every day.
For other cases, conduct the process in the following cases.
- Before you output a job that the color is important
- When you are not satisfied with the color stability (want to improve the reproducibility)

)Adjustment order

Order Adjustment item Required time Reference


Approximately
1 Gamma Automatic Adjustment P.3-49
1 minute
Approximately
2 Maximum Density Auto Adjustment (RU) P.3-61
3 minutes

Reference
For details of each adjustment item, refer to "Contents of the image quality adjustment items" (Page 3-47).

3-45
bizhub PRESS C1100/C1085

Adjustment flow when changing the screen

)Adjustment timing
- When you change the setting of Custom Screen

)Adjustment order
Order Adjustment item Required time Reference
Change setting of Custom Screen Approximately P.3-47
1
1 minute
Gamma Automatic Adjustment Approximately P.3-49
2
1 minute
Density Balance Adjustment * Approximately P.3-50
3
(for i1Pro/i1Pro2/ES-1000/ES-2000) 10 minutes
Color Density Manual Control Approximately P.3-66
4
1 minute
Controller Calibration Approximately P.3-68
5
5 minutes

* When the changed Custom Screen is [Stochastic], Density balance adjustment is not required.

Tips
If you interrupted the operation during the adjustment flow, be sure to perform Gamma Automatic Adjustment before
the rest of adjustment flow.
Reference
For details of each adjustment item, refer to "Contents of the image quality adjustment items" (Page 3-47).

3-46
Contents of the image quality adjustment items

This section describes the contents of the following 9 adjustment items.


- Change setting of Custom Screen (Page 3-47)
- Gamma Automatic Adjustment (Page 3-49)
- Density Balance Adjustment (for i1Pro/i1Pro2/ES-1000/ES-2000) (Page 3-50)
- Added procedures of Density Balance Adjustment (Registration of color measurement data using a USB
memory) (Page 3-59)
- Maximum Density Auto Adjustment (RU) (Page 3-61)
- Check setting of Color Density Control (Page 3-63)
- Color Density Manual Control (Page 3-66)
- Controller Calibration (IC-308/IC-310) (Page 3-68)

)Change setting of Custom Screen

1 Press Utility/Counter on the machine's


control panel.

2 Press [Administrator Setting].


Tips
To enter [Administrator Setting], the administrator
privilege may be required. Contact your machine
administrator.

3-47
bizhub PRESS C1100/C1085

3 Press [System Setting] on the


[Administrator Setting Menu] screen, and
then press [Expert Adjustment], [Quality
Adjustment], and [Custom Screen] in
sequence.

4 Press the screen to be assigned to each


screen type: [Screen 1], [Screen 2], and
[Stochastic]. After setting, press [OK].
NOTICE
[Dot190] is recommended as the configuration for [Screen
1].

3-48
)Gamma Automatic Adjustment

1 On the touch panel of the main body,


press [Adjustment] on the [MACHINE]
screen.

2 Press [Execute Adjust Operation] on the


[Adjustment Menu] screen.

3 Press [Gamma Automatic Adj.] and press


[OK].

4 Press [Exit [ADJUSTMENT]].


Wait for the display "Now adjusting" to disappear.

3-49
bizhub PRESS C1100/C1085

)Density Balance Adjustment (for i1Pro/i1Pro2/ES-1000/ES-2000)

NOTICE
To measure the chart, use the X-rite Measure tool. Install the tool in advance.
You can download the X-rite Measure tool at the following Web site. After installing the tool, restart the computer.
ProfileMaker 5 v5.0.10:
http://www.xrite.com/product_overview.aspx?ID=757&Action=Support

1 On the touch panel of the main body,


press [Adjustment] on the [MACHINE]
screen.

2 Press [Density Balance Adjustment] on


the [Adjustment Menu] screen.

3 Press [Density Balance Chart Output].

3-50
4 Select the desired chart type from
"Measure Spectrophotometer-2", and
press [Print Mode].
[Type2] is recommended.

5 Press [Quality Adj.].

6 Press [Screen Pattern] and select the


screen that is changed at "Change
setting of Custom Screen" in the
adjustment items (screen for Density
balance adjustment) .
Tips
[Stochastic] is unavailable.

7 Select paper for chart output.


Tips
Load 12 e 18 w, SRA3 w, 11 e 17 w, or A3 w paper in a
tray, then select that tray.
Load the paper of paper type and weight that you want to
register on the density balance adjustment data into the
target tray.
This machine selects the density balance adjustment data
to apply a job in accordance with the following priority.
Priority 1: Screen > Priority 2: Paper Type > Priority 3:
Weight > Priority 4: Registered Order
(If there is no density balance adjustment data for the
screen that corresponds to a job, the job is output without
correcting its density balance.)

3-51
bizhub PRESS C1100/C1085

8 Press Start on the control panel.


The color chart is output for measurement using
the spectrophotometer.

9 Press [Exit PrintMode].

10 Press [Return], and return to the [Density


Balance Adjustment Menu] screen.

3
11 On the computer where the X-rite Measure tooL. l has been installed, select [Start] -
[All Programs] - [X-Rite] - [ProfileMaker Pro 5.0.10] - [MeasureTool].

12 When the following message is


displayed, click [OK].

3-52
13 Connect the instrument to the computer.
From the menu, click [Configuring].

14 In [Instrument], select [Eye-One Pro].


When [OK] is displayed, close the
screen.

15 From the menu, click [Measuring].

3-53
bizhub PRESS C1100/C1085

16 From [Test Chart], select [Custom].

17 Specify [Columns] and [Rows], and click


[OK].
- When the chart type is "Type 1":
[Columns] = 6, [Rows] = 5
- When the chart type is "Type 2":
[Columns] = 6, [Rows] = 13

18 Click [Start].

19 When the following message is displayed, horizontally place the spectrophotometer


on the calibration dock and click [OK].

3-54
20 Stack 10 sheets of blank paper whose type is the same as that of the paper where
chart has been printed, and place the printed chart on top of it.

21 When the following screen is displayed,


place the spectrophotometer on the
patch at the top in the upper left, and
press the button for the
spectrophotometer. When beep sounds,
check that the read patch is displayed on
the screen.
Tips
For i1Pro2/ES-2000, install the positioning target to the
spectrophotometer before you measure the color.

22 Continuously, place the


spectrophotometer on the next right
patch, and press the button for the
spectrophotometer. Measure all the
patches in the same operation.
If you place the spectrophotometer on the wrong
place (patch), click the button to go back to
the previous patch position.
The white portion where it is displayed that
nothing is printed is also part of the patch. Do not
forget to measure it. If not measured, an error will
occur.

23 When you are finished with the chart


measurement, click [Close].

3-55
bizhub PRESS C1100/C1085

24 From the [File] menu, select [Save As].


NOTICE
If you use [Export Lab], an error occurs when registering
the color adjustment data. When saving the data, always
use [Save As].

25 Specify the destination to save.


Specify USB memory or the computer connected to the machine via the network.

Destination to save Description


USB Memory Connect the USB memory to the computer.
Create a folder, "\C1100\ADJUST_DATA," in the root (immediately be-
low) of the USB memory, and specify the place as the destination to
save.
Computer on the network Open the computer connected to the network used by the machine, and
specify a desired folder.

26 Enter the file name to save the measured


data and click [Save].
Specify the "14-character identification number
printed on the chart" + "_" (underscore) +
"character string of up to 21 characters."
Example: 30255160110D27_2014-07-25.txt
Reference
When you save in a USB memory, go to "Added
procedures of Density Balance Adjustment (Registration
of color measurement data using a USB memory)" (Page
3-59).

3
27 On the computer on the network where the measured data has been saved, open a
Web browser.

28 In the URL field, enter "http://IP address


of the machine (or the host name):30091"
and press the Enter key.
If the controller of EFI is implemented, ":30091" at
the end of the IP address is unnecessary.

3-56
29 Click [Machine Manager Setting], and
enter the administrator ID and password.
Tips
Contact your machine administrator for the administrator
ID and the password.

30 Click on [Color Measuring data Input].

31 Enter the file name for colorimetric data


into [File Name], click [Browse] on the
side of the file path, and select the
colorimetric data saved in the computer.

32 Click [Upload].
Colorimetric data is saved in the machine.

33 Press [Density Balance Data Reg/Del] on


the [Density Balance Adjustment Menu]
screen to display the [Density Balance
Adj. Data Register/Del] screen.

3-57
bizhub PRESS C1100/C1085

34 Select any one row in the list of 10


profiles, and press [Archived Data].
NOTICE
- No more than 10 pieces of data can be registered,
however, the data can be overwritten. If desired,
select the data to be overwritten.
- The colorimetric data can be synthesized and
registered. To synthesize data, select the row having
the same screen type, paper type, and weight.

35 Select the file name of the data to be


registered, then press [OK].

Tips
With a row of the existing data selected in step 34, a
confirmation dialog is displayed.
To synthesize the selected data with the new data, press
[Combination]. If conditions for screen type, paper type,
or weight do not correspond to each other, [Combination]
dims.

36 When the following screen is displayed, 3


press [OK].

3-58
)Added procedures of Density Balance Adjustment
(Registration of color measurement data using a USB memory)

1 Press [Density Balance Data Reg/Del] on


the [Density Balance Adjustment Menu]
screen to display the [Density Balance
Adj. Data Register / Del].

2 Select any one row in the list of 10


profiles, and press [USB Memory].
NOTICE
- No more than 10 pieces of data can be registered,
however, the data can be overwritten. If desired,
select the data to be overwritten.
- The colorimetric data can be synthesized and
registered. To synthesize data, select the row having
the same screen type, paper type, and weight.

3 The following screen is displayed.


Connect the USB memory where the
measured data has been saved to the
main body, and press [OK].

4 Select the file name of the measured


data to be registered and press [OK].

3-59
bizhub PRESS C1100/C1085

Tips
With a row of the existing data selected in step 2, a
confirmation dialog is displayed.
To synthesize the selected data with the new data, press
[Combination]. If conditions for screen type, paper type,
or weight do not correspond to each other, [Combination]
dims.

5 When the following screen is displayed,


press [OK].

3-60
)Maximum Density Auto Adjustment (RU)

NOTICE
To enable this function, your service representative must specify the target maximum density value (target density) in
advance. For more information, contact your service representative.
Before you carry out Maximum Density Auto Adjustment (RU), check that the configuration of Screen 1 is Dot190. If
Screen 1 is not configured to Dot190, perform "Change setting of Custom Screen" (Page 3-47), and change Screen 1
to Dot190.
Carry out Maximum Density Auto Adjustment (RU) using the paper that is used to register the target maximum density
value (target density).

1 Press [Adjustment] on the [MACHINE]


screen.

2 Press [Max.Density Auto Adj. (RU)].

3 Press [Print Mode].

4 Load the paper that has been used to register the target density into the tray.
The paper profile of the tray is automatically switched to the paper profile that has been used to register
the target density.

3-61
bizhub PRESS C1100/C1085

5 Select the tray containing paper, then


press [OK].

6 Press Start on the control panel.


A chart is printed out, and auto adjustment starts.
When the adjustment is completed, you return to
the [Max. Density Auto Adj. (RU)] screen.
Adjustment processing cannot be stopped until all
charts are printed out.

7 When the adjustment is completed, you


automatically return to the [Maximum
Density Auto Adjustment] screen. Check
the adjustment result.
The auto adjustment result is displayed in [Current
Data].

3
8 Press [Return] to return to the [Process Adjustment Menu] screen.
Note that the tray remains set to the paper profile that has been used to register the target density.

Tips
If [Maximum Density Auto Adjustment] is carried out, the paper profile of the tray that has been used for auto
adjustment is switched to the paper profile that has been used to register the target density , and it is not returned to
the paper profile that has been used before adjustment. After the adjustment is completed, return to the original paper
profile. After completing this adjustment, you can ask your service representative to configure a setting so that the
paper profile automatically returns to that used before adjustment. For more information, contact your service
representative.

3-62
)Check setting of Color Density Control

1 Press [Adjustment] on the [MACHINE]


screen.

2 Press [Color Density Control].

3 Press [Basic Setting].

4 Check that the [Use Color Density


Control] and [Periodical Adj. Execution]
are configured to [ON].
Tips
[Adjustment Execution Timing] is a configuration for a job
that contains different screens and paper types.
When you want to prior the color unification within 1 job,
select [Before Job Start].
When you want to prior the color unification within
multiple jobs, select [During Job Runs].

3-63
bizhub PRESS C1100/C1085

5 Press [Next].

6 Check that the [Switch Color(1st or 2nd)]


is configured to [Precise].
NOTICE
Select [Precise] or [Normal] depending on the situation.
- When you select [Precise], both the 1st color (YMCK)
and the 2nd color (RGB) are corrected.
When you want to prior the quality, select [Precise].
- When you select [Normal], only the 1st color (YMCK)
is corrected. Select [Normal] when you want to
reduce the amount of paper you use for color density
control.

7 Press [OK].

3
8 Press [Close].

3-64
9 Press [Exit [ADJUSTMENT]].
Automatic Adjustment is set. A chart is printed out
periodically, and calibration is carried out
automatically.

3-65
bizhub PRESS C1100/C1085

)Color Density Manual Control

1 Press [Adjustment] on the [MACHINE]


screen.

2 Press [Color Density Control].

3 Press [Color Density Manual Control].


This function is available only when [Use Color
Density Control] is set to [ON] in [Color Density
Control] - [Basic Setting].

4 Press [Print Mode].

3-66
5 Press [Quality Adj.].

6 Press of [Screen Pattern] to select


a screen.

7 Press [Close].

8 Press Start.
A chart is printed out, and calibration is carried out.

3-67
bizhub PRESS C1100/C1085

)Controller Calibration (IC-308/IC-310)

1 Use a USB cable to connect EFI Spectrometer ES-1000/ES-2000 to your computer.


For details about how to use EFI Spectrometer ES-1000/ES-2000, refer to the manual supplied with the
spectrophotometer.

2 Open the Start menu, and then click [All Programs] - [Fiery] - [Fiery Command
WorkStation 5].

3 Select a Fiery Color Server to be


connected, then click [Add].
You can also specify any subnetwork or the IP
address range to search for the desired Fiery
Color Server.

4 Click [Connect].

5 Select the user privileges, then enter the


password. 3
- The default password is "Fiery.1."
If [Operator] or [Guest] is selected for user
privileges, you do not need to enter the
password.

6 Click [Login].
Fiery Command WorkStation starts.

3-68
7 Click [Job Center] - [Calibrate] in
sequence.
Calibrator starts.

8 Select the printing preferences for


calibration.
Example: Configure the [Calibrate] to [Coated
(128gm2)], the [Paper source] to [Tray 3], and the
[Measurement method] to [EFI ES-2000].

9 Click [Continue].
A chart is printed out in a matter of time after this
machine started running.

10 Click [OK].

3-69
bizhub PRESS C1100/C1085

11 Securely place EFI Spectrometer ES-


1000/2000 in the calibration cradle, then
click [Continue].

12 Stack 10 sheets of blank paper whose type is the same as that of the paper where
chart has been printed, and place the printed chart on top of it.

13 Follow the instructions on the


measurement window to measure color
strips in sequence.
- Hold down the measurement button of EFI
Spectrometer ES-1000/2000. After you hear a
beep, slide it while holding down the
measurement button.
Slide EFI Spectrometer ES-1000/ES-2000 to
the bottom of strip, then release the
measurement button.
- For details about how to use EFI
Spectrometer ES-1000/2000, refer to the
manual supplied with the spectrophotometer.

14 In the same way, measure all colors.


- When a strip is measured successfully, a
check mark is displayed at the top of the color
name, and is displayed for the color to be
measured next.

15 When all the patches have been read


successfully, click [Continue].

3-70
16 Click [Apply & Close].
The calibrated measurement values are applied.

3-71
bizhub PRESS C1100/C1085

Blank Page

3-72
© 2016 2016. 6