0% found this document useful (0 votes)
93 views32 pages

Three Phase Pocket Guide Brochure

The document discusses Schneider Electric's three-phase power protection product portfolio including UPS systems ranging from 10 kW to multi-megawatt. It provides details on their Symmetra and Galaxy UPS product families, specifications for individual models, and power distribution and management options. The portfolio is designed to provide high availability power protection for data centers and industrial applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
93 views32 pages

Three Phase Pocket Guide Brochure

The document discusses Schneider Electric's three-phase power protection product portfolio including UPS systems ranging from 10 kW to multi-megawatt. It provides details on their Symmetra and Galaxy UPS product families, specifications for individual models, and power distribution and management options. The portfolio is designed to provide high availability power protection for data centers and industrial applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 32

Three-Phase

Power Protection
208 – 480 – 600 V
Regions
Table of Contents:
Products, Accessories, and Services

Introduction .................................................................... 3

Three-Phase Power Portfolio .......................................... 4

Three-Phase UPS Product Families ............................... 5

InfraStruxure™ 20 kW ..................................................... 6

Symmetra™ PX 40 kW .................................................... 7

Symmetra PX 100 kW .................................................... 8

Symmetra PX 250/500 .................................................. 9

Symmetra Megawatt .................................................... 10

Smart-UPS™ VT............................................................ 11

MGE Galaxy™ 3500....................................................... 12

MGE Galaxy 4000 ........................................................ 13

Galaxy VM .................................................................... 14

MGE Galaxy 5000 ........................................................ 15

MGE EPS 6000 ............................................................ 16

MGE EPS 7000 ............................................................ 17

MGE EPS 8000 ............................................................ 18

MGE Epsilon STS ........................................................ 19

Three-Phase Power Distribution Portfolio ...................... 20

Configurable Power Distribution ................................... 21

Modular Power Distribution ......................................... 22

Cabinet Power Distribution ......................................... 23

Management Options and Cards ................................. 24

Compatibility Matrices .................................................. 26

StruxureWare™ for Data Centers Software Suite ........... 28

A Comprehensive Portfolio of Services ........................ 29

Other Available Services............................................... 31


2
Introduction

Schneider Electric™ is a world leader in power protection,


solving today’s energy challenges while setting the standard
for quality and innovation with fully integrated solutions,
enterprise-wide networks, data centers, mission-critical
systems, and industrial/manufacturing processes.

Our global portfolio of world-class products and services


uniquely combines to offer end-to-end critical power
solutions, providing customers with the highest levels of
availability, reduced total cost of ownership, and improved
energy efficiency throughout the life cycle of their installations.

Providing the highest


levels of availability,
reduced total cost
of ownership,
and improved
energy efficiency

HAZARD OF EQUIPMENT DAMAGE. These UPS systems


are not compatible with — and should not be used to
protect — regenerative loads (loads generating power
back to the network), such as photovoltaic systems and
speed drives. Failure to follow these instructions could
result in equipment and/or UPS damage and would result
in void of UPS warranty.

For more information: www.apc.com 3


Three-Phase Power Portfolio

Customer applications

Symmetra range Galaxy range


Symmetra MW, MGE Galaxy EPS 6000,
PX 250/500 EPS 7000, EPS 8000
> TCO is key > First cost is critical
Large/ (breakthrough > Redundancy through
extra- efficiency) power architectures
large data > Intrinsic redundancy (parallel UPS)
centers > Highest IT solution > Adaptable to any
integration (aesthetics) requirements
> Ideal for greenfield (electrical, IP, etc.)
projects or high- > Fits with any existing
density zones architecture and any
size data center

Symmetra range Galaxy range


InfraStruxure MGE Galaxy 3500,
20 kW All-In-One, 4000, 5000, Smart-
Symmetra PX 40, UPS VT, Galaxy VM
Symmetra PX 100 > First cost is critical
> TCO is key > Redundancy through
Small/ t#SFBLUISPVHI power architectures
medium efficiency (parallel UPS)
data t4QFFEPG > Adaptable to any
centers deployment requirements
t&BTZHSPXUIGVUVSF (electrical, IP, etc.)
proofing > Most likely, there
> Intrinsic redundancy is a dedicated
“electrical room”
>#FTU*5TPMVUJPO
integration (aesthetics)
> Ideal for “single room”
integrated data center
physical infrastructure

Galaxy range
MGE Galaxy 3500,
4000, Galaxy VM, 5000,
EPS 6000, 7000, 8000
> Flexible and adaptable
Industry to requirements
and > High electrical
infrastructure performance
> Compatible with
wide range of critical
applications, from
medical to process
automation

4
Three-Phase UPS Product Families
(208 – 600 V Regions)

Symmetra range Galaxy range

400 – 1,600 kVA

555 – 1,100 kVA

300 – 500 kVA


Symmetra MW
MGE EPS 8000

MGE
EPS 7000

300 – 375 kVA

40 – 130 kVA
Symmetra PX MGE
250/500 MGE
EPS 6000 Galaxy 5000
150 – 225 kVA

40 – 75 kVA
10 – 500 kVA

Symmetra PX 100 Galaxy VM MGE


Galaxy 4000
10 – 30 kVA

Symmetra PX 40
Galaxy 3500
10 – 40 kVA

InfraStruxure
20 kW (Symmetra
PX 20 kW All-In-One)
Smart-UPS VT

IT IT data centers, industry,


data centers and infrastructure

For more information: www.apc.com 5


InfraStruxure 20 kW
(Symmetra PX 20 kW All-In-One)
10 – 20 kVA

Applications

> Data closets > High-density zones


> Small data centers

Characteristics

> Power ratings 10 and 20 kW N+0 or N+1


> Output power factor Unity (kVA=kW)
> #BUUFSZ 7BMWFSFHVMBUFEMFBEBDJE
> Parallel capability None
> Front display PowerView local display
> Efficiency 91.5%
> Communication UPS network management card
(AP9617) included
> Input voltage 208 V, 3-phase + N + G
> Output voltage 208 V, 3-phase + N + G or 3P + G
> Warranty 1 year

Features

> Single-rack design > Front access only


> Configurable power > Maintenance bypass panel
distribution > Dual mains input, top or
> Redundant intelligence module bottom feed
> Hot-swappable power > Start-up service included
modules > Network-manageable
> Hot-scalable batteries

Options

> Extended runtime battery frames


> Secondary network management card (HTTP/Telnet/SNMP)
> Configurable power accessories

Dimensions

> HxWxD 81.5 x 23.5 x 35.6 in.


> Weight without batteries
or power modules 665 lb.
> Weight fully populated with
batteries and power modules 1,803 lb.

6
Symmetra PX 40 kW
10 – 40 kVA

Applications

> Small data centers > High-density zones of


> Medium data centers large data centers

Characteristics

> Power ratings 10 to 40 kW, in 10 kW increments


> Output power factor 1
> #BUUFSZ 7BMWFSFHVMBUFEMFBEBDJE
> Parallel capability None
> Front display PowerView local display
> Efficiency 91.5%
> Communication UPS network management card
(AP9630) included
> Input voltage 208 V, 3-phase + N + G
> Output voltage 120/208 V, 3-phase + N + G
> Warranty 1 year

Features

> Single-rack > Start-up service included


> Hot-scalable power modules > Redundant intelligence module
> Hot-swappable batteries > Network-manageable
> #PUUPNGFFE

Options

> Extended runtime battery frame


> Maintenance bypass panel
> Isolation transformer
> #BUUFSZCSFBLFSCPY
> Configurable power distribution units
> Secondary network management card (HTTP/Telnet/SNMP)

Dimensions

> HxWxD 82 x 36 x 24 in.


> Weight without batteries
(40 kW UPS) 600 lb.
> Weight with 6-min. runtime
(40 kW UPS) 1,700 lb.

For more information: www.apc.com 7


Symmetra PX 100 kW
10 – 100 kVA

Applications

> Small/medium data centers


> High-density zones of large
data centers

Characteristics

> Power ratings 10 to 100 kW, in 10 kW increments


> Output power factor 1
> #BUUFSZ 7BMWFSFHVMBUFEMFBEBDJE
> Parallel capability None
> Front display PowerView local display
> Efficiency 92.5%
> Communication UPS network management card
(embedded)
> Input voltage 208 V, 3-phase + N + G
> Output voltage 120 V/208 V, 3-phase + N + G
> Warranty 1 year

Features

> Hot-scalable power modules > Hot-swappable static


> Hot-swappable batteries bypass switch
(five- to eight-year life) > Redundant intelligence module
> Unity power factor corrected > Network-manageable
> Dual mains input, top feed > Fault-tolerant N+1 design
> Start-up service included

Options

> Extended runtime > Modular power distribution


battery frames units with maintenance
> 11.8 in. bottom feed frame bypass and fully rated
subfeed breaker (600:208 V,
480:208 V, 208:208 V, and
transformerless 208 V)

Dimensions

> HxWxD 79.1 x 47.2 x 42.1 in.


> Weight without batteries
(100 kW UPS only) 1,436 lb.
> Weight with 5-min. runtime
(100 kW UPS only) 4,224 lb.

8
Symmetra PX
250/500 kW
25 – 500 kVA

Applications

> Medium/large data centers > Mission-critical environments

Characteristics

> Power ratings One UPS: 25 kVA to 500 kVA,


in 25 kVA increments
Fully populated parallel system: 25 kVA
to 2 MVA, in 25 kVA increments
> Output power factor 1
> #BUUFSZ 7BMWFSFHVMBUFEMFBEBDJE
> Parallel capability Up to 4 UPS units, for capacity
or redundancy
> Front display Localized 10 in. touch screen display
> Efficiency 96%
> Communication UPS network management card
(AP9635) included
> Input voltage 380/400/415/480 V, 3-phase + N + G
> Output voltage 380/400/415/480 V, 3-phase + N + G
> Warranty 1 year

Features

> Hot-scalable power modules > Redundant intelligence module


> Hot-swappable batteries > Module or system level
(five- to eight-year life) N+1 redundancy
> Unity power factor corrected > No rear access required
> Dual mains input, top or > Ultra-high efficiency (96% at
bottom feed 35% load, 95% at 25% load)
> Start-up service included > Network-manageable
> Hot-swappable static
bypass switch

Options

> Third-party battery cabinets > Maintenance bypass with


> Extended runtime EJTUSJCVUJPODBCJOFU .#X%

battery frames > #BUUFSZTJEFDBS


> #BUUFSZCSFBLFSFODMPTVSF > #PUUPNGFFEGSBNF
> Modular power distribution

Dimensions, 500 kW UPS

> HxWxD without batteries


PS.#X% YYJO
> HxWxD with 6-min. runtime
BOE.#X% YYJO
> Weight without batteries
PS.#X%  MC
> Weight with 6-min. runtime
BOE.#X%  MC

For more information: www.apc.com 9


Symmetra
Megawatt
400 – 1,600 kVA

Applications

> Medium/large data centers, > Mission-critical environments


buildings, or facilities

Characteristics

> Power ratings 400 to 1,600 kVA, scalable in


200 kVA increments
> Input power factor Unity
> Output =r factor Unity (kVA=kW)
> #BUUFSZ 7BMWFSFHVMBUFEMFBEBDJE WFOUFE
lead acid, nickel cadmium, lithium-ion
> Parallel capability Up to 9 UPS units for 14.4 MW of
capacity or redundancy — the world’s
largest UPS solution
> Front display Touch screen LCD display
> Efficiency > 97%
> Communication Touch screen LCD display
> Input voltage 480 V, 3-phase + N + G
> Output voltage 480 V, 3-phase + N + G
> Warranty 1 year

Features

> Fault-tolerant module or > Start-up service included


system level N+1 redundancy > InfraStruxure Central
> Universal battery support compatible
> Modular design > Static bypass switch (internal,
> #BUUFSZGBJMVSFOPUJGJDBUJPO 400 – 600 kW; external,
> No rear access required 800 – 1,600 kW)
> Unity power factor corrected > Ultra-high efficiency (> 97% at
(input and output) 85% load; 96% at 45% load;
> Dual mains input, top or 94% at 25% load)
bottom feed

Options

> Third-party battery cabinets > UPSync module


> Maintenance bypass cabinet

Dimensions*

> HxWxD, MW400 80 x 83 x 42 in.


> HxWxD, MW1600 80 x 216 x 42 in.
> Weight, MW400 4,669 lb.
> Weight, MW1600 14,028 lb.

*Dimensions do not include batteries.

10
Smart-UPS VT
10/15/20/30 kVA

Applications

> Small data centers > Medical server rooms


> Server rooms and laboratories
> Commercial buildings, retail, > Government and institutions
and points of sale

Characteristics

> Power ratings 10, 15, 20, 30 kVA


> Output power factor 0.8
> #BUUFSZ *OUFHSBUFE NBJOUFOBODFGSFF 
sealed lead acid
> Parallel capability Up to 4 units for capacity or redundancy
> Front display Multifunction LCD status and
control console
> Efficiency 94% at 100% linear load (+ or - .5%)
> Communication Network SNMP and environmental
monitoring (AP9631) included
> Input voltage 208 V – 220 V (3PH + N + G)
> Output voltage 200 V – 220 V (3PH + N + G)
> Warranty 1 year

Features

> Compact form factor > Parallel for capacity or


> Reduced footprint redundancy — up to 3 units
> Tower and rack mount > Scalable architecture
> Hot-scalable runtime — > Dual mains input
modular batteries > Step load voltage stabilization
> Start-up service included

Options

> Matching external runtime > Parallel maintenance bypass


frame with or without breakers cabinet for up to 3 units
> Single cabinet maintenance > Network management card
bypass floor mount with or (AP9631) with environmental
without 42-pole distribution monitoring
panel

Dimensions

> UPS (wide tower) (HxWxD) 59 x 21 x 33 in.


Weight (1,455 lb.) max
> UPS (narrow tower) (HxWxD) 59 x 14 x 33 in.
Weight (428 lb.) max
> Parallel maintenance bypass 59 x 14 x 33 in.
Weight (317 lb.) max
59 x 21 x 33 in.
Weight (377 lb.) max

For more information: www.apc.com 11


MGE Galaxy 3500
10/15/20/30 kVA

Applications

> Commercial buildings > Telecommunication centers


> Transportation and > Technical facilities
infrastructures > Industrial plants and
process protection

Characteristics

> Power ratings 10, 15, 20, 30 kVA


> Output power factor 0.8
> #BUUFSZ *OUFHSBUFE NBJOUFOBODFGSFF 
sealed lead acid
> Parallel capability Up to 4 units for capacity or redundancy
> Front display Multifunction LCD status and
control console
> Efficiency 94% at 100% linear load (+ or - .5%)
> Communication Network SNMP and environmental
monitoring (AP9631) included
> Input voltage 208 V – 220 V (3PH + N + G)
> Output voltage 208 V
> Warranty 1 year

Features

> Compact form factor, > User-replaceable air filters


reduced footprint > Start-up service included
> Dual mains input > IP51 rating
> Hot-swappable batteries > Sturdy .08 in. front panel
> Input power factor correction

Options

> Matching external runtime > Seismic brackets


frame with batteries > User-replaceable air filters
> Single and parallel bypass > Network management card
panel — floor mounted (AP9635) with environmental
> Empty frame for third-party monitoring, Modbus,
batteries Teleservices
> Empty frame for third-party
transformers

Dimensions

> UPS (wide tower) (HxWxD) 59 x 21 x 33 in.


Weight (1,181 lb.) max
> UPS (narrow tower) (HxWxD) 59 x 14 x 33 in.
Weight (873 lb.) max
> External runtime frame (HxWxD) 59 x 21 x 36.5 in.
Weight (1,707 lb.) max

12
MGE Galaxy 4000
40/50/60/75 kVA

Applications

> Mission-critical environments > Industrial plants


> Small/medium data centers > Telecommunication centers

Characteristics

> Power ratings 40, 50, 65, 75 kVA


> Output power factor 0.8
> #BUUFSZ "EKBDFOU SFNPUF 73-" XFUDFMM
> Front display Mimic LED display
> Efficiency 90% at 100% linear load (+ or - 5%)
> Communication RS232, RS485, network SNMP,
dry contacts
> Input ratings 208 V, 3-phase
> Output ratings 208 V, 3-phase
> Warranty 1 year

Features

> Fault-tolerant circuitry > Low input THD (< 3%)


> Online double > Extended runtimes available
conversion topology > Top or bottom entry
> Field upgradeable > Communication cards for
> Digital power quality every application

Options

> Internal or external > Line-up and match battery


maintenance bypass cabinet cabinet and auxiliary cabinets
> Matching 42-pole distribution > 65 kAIC rating
> Seismic brackets > Dual input

Dimensions

> UPS (HxWxD) 72 x 34 x 36 in.


Weight (1,234 lb.) max
> #BUUFSZDBCJOFU )Y8Y%
 YYJO
Weight (2,730 lb.) max
> Distribution cabinet (HxWxD) 72 x 20 x 34 in.
Weight (330 lb.) max

For more information: www.apc.com 13


Galaxy VM
180/225 kVA

Applications

> Mission-critical environments > Industrial plants


> Small/medium data centers > Facility infrastructure

Characteristics

> Power ratings 180, 225 kVA


> Parallel capability Up to 4 units for capacity, 5 for redundancy
> Output power factor 0.9
> #BUUFSZ 73-"
> Front display 7 inch touch screen color with built-in NMC
> Efficiency Up to 96.5% at 100% linear load
> Communication Modbus (SCADA and ION-E),
2 empty card slots, dry contacts,
network/Web SNMP
> Input voltage 480 V
> Output voltage 480 V
> Warranty 1 year

Features

> Highly efficient > Industry-leading footprint


ECOnversion mode > Replaceable dust filters
> Flexible modular and classical > Single cabinet top and bottom
battery solutions cable entry
> 04)1%BOE*#$® seismic > Integrated casters for ease
certified of mobility
> Large color touch screen
display with built-in NMC

Options

> Management cards > Parallel system


> #BUUFSZDBCJOFUT‰NPEVMBS bypass cabinets
and classical > Dust filter kits
> Fuse kits > System bypass cabinets
> Wall mounted battery
breaker boxes

Dimensions

> UPS 77.56 x 39.45 x 33.62 in.


(HxWxD) Weight 180 kVA: 1,497 lb.
225 kVA: 1,552 lb.
> 450 kVA system bypass cabinet 80.57 x 71.06 x 71.06 in.
(HxWxD) Weight 1,235 lb.
> 675 kVA system bypass cabinet 80.57 x 82.09 x 45.51 in.
(HxWxD) Weight 1,279 lb.

14
MGE Galaxy 5000
40/50/60/80/100/130 kVA

Applications

> Medium data centers > Telecommunication centers


> Industrial plants > Mission-critical environments

Characteristics

> Power ratings 40, 50, 60, 80, 100, 130 kVA
> Parallel capability Up to 6 units for capacity or redundancy
> Output power factor 0.9
> #BUUFSZ *OUFHSBUFE BEKBDFOU SFNPUF 
open rack, VRLA
> Front display Graphical display available in
18 languages
> Efficiency Up to 94% at 100% linear load
(+ or - .5%)
> Communication RS232, RS485, network SNMP,
dry contacts
> Input voltage 480 V (208 and 600 V with transformer)
> Output voltage 480 V (208 and 600 V with transformer)
> Warranty 1 year

Features

> Dual input > Input distortion management


> Step load voltage stabilization > Internal maintenance bypass
> Intelligent battery management > User-friendly multi-language
> #PUUPNFOUSZTUBOEBSE display
> Front access electrical > High-power density design
connections

Options

> Matching adjacent empty > Parallel system bypass cabinet


battery cabinet > #BDLGFFEQSPUFDUJPO
> Match adjacent battery cabinet > IP32 pack
> Empty auxiliary cabinet > Fan redundancy
> External synchronization board > Input/output transformers in
(to use with static transfer matching cabinet
switch) > UL 924 rated battery cabinets
(40 – 50 kVA UPS)

Dimensions

> UPS without batteries 76 x 28 x 33 in.


(HxWxD) Weight 1,168 lb.
> Empty battery/auxiliary 75 x 28 x 32 in.
cabinet (HxWxD) Weight 881 lb.
> Transformer cabinet (HxWxD) 75 x 28 x 32 in.
Weight 297 lb.

For more information: www.apc.com 15


MGE EPS 6000
300/375 kVA

Applications

> Medium/large data centers > Industrial plants


> Mission-critical environments > Telecommunication centers

Characteristics

> Power ratings 300, 375 kVA


> Output power factor 0.8
> #BUUFSZ -FBEBDJECBUUFSJFT WFOUFE TFBMFE

NiCad
> Parallel capability None
> Front display User-friendly alphanumerical display
> Efficiency Up to 94% (+ or - .5%)
> Communication Alarm relay card, network management
card, industrial network management card
> Input voltage 208 V to 600 V, 3-phase
> Output voltage 208, 480, 600 V, +/- .5%
> Warranty 1 year

Features

> Digital power quality inverter > Full output regulation over
> Input filter technology entire range of the battery
> Solid-state disc SCR
transfer switch

Options

> #BUUFSZNPOJUPSJOHTZTUFNT > Output distribution (customized)


> #BUUFSJFTDBCJOFUT XJUI73-" > Top cable entry cabinet
batteries), standard offering > Seismic anchors
> Flooded cells/racks > Low kvar input filter
> System static bypass > Critical bus synchronization
switch cabinet module

Dimensions

Rated power 300 kVA/240 kW


Input voltage Module width UPS weight
(normal AC input) (75 in. H x 32 in. D) (without filter)
> 208 162 in. 9,815 lb.
> 480 113 in. 8,379 lb.
> 480 63.5 in. 5,543 lb.
> 600 162 in. 9,815 lb.

Rated power 375 kVA/300 kW


Input voltage Module width UPS weight
(normal AC input) (75 in. H x 32 in. D) (without filter)
> 208 162 in. 10,440 lb.
> 480 113 in. 8,836 lb.
> 480 63.5 in. 5,612 lb.
> 600 162 in. 10,440 lb.

16
MGE EPS 7000
300/400/500 kVA

Applications

> Mission-critical environments


> Medium/large data centers
> Industrial plants

Characteristics

> Power ratings 300, 400, 500 kVA


> Output power factor 0.9
> #BUUFSZ -FBEBDJECBUUFSJFT WFOUFE TFBMFE

NiCad
> Parallel capability Yes
> Front display User-friendly alphanumerical display
> Efficiency Up to 94% ( + or - .5%)
> Communication Dry contact, network management card
> Input voltage 208 V to 600 V, 3-phase
> Output voltage 208, 480, 600 V, +/- .5%
> Warranty 1 year

Features

> Strong electrical features > Synchronization to


> Intuitive monitoring external source
> Parallel capable output > High availability architecture
components

Options

> Input isolation transformer > #BUUFSZNPOJUPSJOH


> Output distribution > Continuous duty and
> External maintenance bypass momentary duty
> #PUUPNDBCMFFOUSZ > Static switch cabinets (SSC)
> Remote alarm status panel > Critical bus synchronization
> Seismic anchors module
> Graphical user interface with > #BUUFSZEJTDPOOFDU
network connection

Dimensions

Rated power (kVA/kW)


300/270, 400/360, 500/450, 300/270, 400/360, 500/450
WxHxD Weight
> UPS module 69 x 82 x 39 in. 6,900 lb.
> Maintenance bypass cabinet 22.75 x 82 x 39 in. 540 lb.
> #PUUPNFOUSZDBCJOFU YYJO MC
> Transformer cabinet 44.75 x 82 x 39 in. 3,600 lb.

For more information: www.apc.com 17


MGE EPS 8000
555/625/750/800/
1,000/1,100 kVA

Applications

> Mission-critical environments > Industrial facilities


> Large data centers

Characteristics

> Power ratings 555, 625, 750, 800, 1,000, 1,100 kVA
> Output power factor 0.9
> #BUUFSZ -FBEBDJECBUUFSJFT WFOUFE TFBMFE

NiCad
> Parallel capability Up to 6 modules (1,100 kVA)
> Front display User-friendly alphanumerical display
> Efficiency Up to 93% (+/- .5%)
> Communication Dry contact, network management
card, SNMP
> Input voltage 480 or 600 V, 3-phase
> Output voltage 480 or 600 V
> Warranty 1 year

Features

> Strong electrical features > Synchronization to


> Intuitive monitoring external source
> Parallel capable output > High availability architecture
components

Options

> #BUUFSZNPOJUPSJOHTZTUFNT > Top cable entry cabinet


> #BUUFSJFTDBCJOFUT XJUI73-" > Seismic anchors
batteries), standard offering > Critical bus synchronization
> Flooded cells/racks > System static bypass
> Output distribution (customized) switch cabinet

Dimensions

Rated power (kVA/kW)


555/500, 625/562, 750/675, 800/720, 555/500, 625/562
WxHxD
> Multi-module 121 x 82 x 39 in.
> Maintenance bypass for single module 22 x 82 x 39 in.
> #PUUPNFOUSZ YYJO
> #BUUFSZEJTDPOOFDU YYJO

Rated power (kVA/kW)


555/500, 750/675, 625/562, 800/720
WxHxD Weight
> Single module, top entry 121 x 82 x 39 in. 12,200 lb.
> UPS cabinet 135 x 82 x 39 in. 14,000 lb.

18
MGE Epsilon STS
200/400/600 kVA

Applications

> Industrial applications > Telecommunication centers


> Data centers

Characteristics

> Power ratings 200 to 600 A


> Efficiency (Linear load and PF = 0.8) : 0.99
> Nominal voltage 208, 220, 240, 440, 480, 575, 600 Vac
(+/- 10% adj. up to +/- 15%)
> Warranty 1 year

Features

> Minimizes space requirements > Allows isolation of a source


> Independent control boards, for maintenance, without
dual cooling systems and interrupting power to the
power supplies protected loads
> Text and mimic diagrams > Small footprint
display modes of operation,
system parameters, and alarms

Options

> $
 PNNVOJDBUJPOOFUXPSLNBOBHFNFOUDBSE +#VT.PECVT
card (supplied as standard), status information card (supplied
as standard)
> PDU distribution unit (36 16 A circuit breakers incorporated in the
H = 1900 cell, up to 100 A)
> Connection at the top of the unit

Dimensions

> Capacities (amps) 200


> Dimensions DxHxW 30 x 72 x 25 in.
> Weight 910 lb.

> Capacities (amps) 400 and 600


> Dimensions DxHxW 30 x 72 x 39 in.
> Weight 1,375 lb.

For more information: www.apc.com 19


Three-Phase Power
Distribution Portfolio

Small, medium, and large data centers

Modular power distribution


> Minimal, white space footprint
> Truly safe with hot-scalable modules
> Toolless expansion
> Easy integration with InfraStruxure solutions
> Pre-configured breakers and cord sets for ease of deployment
> Fully compliant, global offering
> 72 kW 5U PDU, 144 kW PDU, 266 kW PDU, 277 kW PDU

Configurable power distribution


> Configured to order
> Factory assembled for high quality
> Easy integration with InfraStruxure solutions
> Pre-configured cord sets
> 40 – 150 kW PDU,10U RPP

Data centers and industrial applications

Cabinet power distribution


> Customized and factory assembled for high quality
> Customers are experienced with the form factor
> Easily expandable using Remote Power Management Modules

20
Configurable Power
Distribution
40/60/150 kW

Applications

> Small, medium, and large data centers

Characteristics, 40/60/150 PDU

> Full load rating Up to 150 kW


> Panel positions 150 kW PDU: 84
> Front display PowerView local display
> Input voltage 208/480/600 V
> Output ratings 120/208 V, 3-phase
> Warranty 1 year

Characteristics, 10U rack power panel (RPP)

> Full load rating Up to 28.8 kVA


> Panel positions 42
> Input voltage 120/208 V, 3-phase
> Output ratings 120/208 V, 3-phase
> Warranty 1 year

Features, 40/60/150 kW PDU

> Top or bottom cable entry > NEMA®-rated TP1 transformers


> Flexible configure-to-order > Aesthetic design
options > No side access required
> Factory assembled and tested

Features, 10U rack power panel (RPP)

> Flexible configure-to-order > Aesthetic design


options > No side access required
> Factory assembled and tested

Options

> #SBODIDJSDVJUNPOJUPSJOH > Start-up service


> Shielding troughs

Dimensions, 150 kW PDU with transformer

> HxWxD 81 x 29 x 36 in.


> Weight (unpopulated) 1,500 lb.

Dimensions, 10U rack distribution panel in


NetShelter™ VX enclosure

> HxWxD 34.5 x 23.5 x 81.5 in.


> Weight (unpopulated) 600 lb.

For more information: www.apc.com 21


Modular Power
Distribution
72/144/266/277 kW

Applications

> Small, medium, and large data centers

Characteristics, 72 kW PDU

> Full load rating 72 kW


> Max. power distribution
modules 6 (18 poles)
> Front display PowerView local display
> Input voltage 208 V, 3-phase + N + G
> Output voltage* 120/208 V
> Warranty 1 year

Characteristics, 144 kW/266 kW/277 kW PDU

> Full load rating Up to 277 kW


> Max. power distribution
modules 24 (72 poles)
> Front display PowerView local display
> Input voltage 144 kW PDU: 208 V
266 kW PDU: 480 V
277 kW PDU: 400 V
> Output voltage* 120/208 V
> Warranty 1 year

Features

> Touch-safe backplane > Modbus supported


> Hot-scalable > High-density distribution
> Integrated monitoring > No rear access required
> Network-enabled > Add circuits with no hot work
or shutdowns

Options

> Power distribution modules with locking connectors


> Start-up service

Dimensions, 72 kW PDU

> HxWxD 9 x 18 x 29 in.


> Weight (unpopulated) 52 lb.

Dimensions, 277 kW PDU

> HxWxD 84.84 x 29.37 x 46.49 in.


> Weight (unpopulated) 380 lb.

*Output voltage may be 1-phase or 3-phase, based on the


connected power distribution module.

22
Cabinet Power
Distribution
30 to 300 kVA

Applications

> Small, medium, and large data centers


> Industrial applications

Characteristics

> Power ratings 30 to 300 kVA


> Max. panel boards 6
> Max. poles 42 per panel board (252 total)
> Front display Front panel with switches and
LED indicators
> Input voltage 120/208, 1-phase or 208, 480,
600 Vac
> Output voltage 120/208 V, 1-phase; 208 V, 3-phase
> Warranty 1 year

Features

> Integrated isolation, > 200%-rated neutral bus


electronic-grade grounding > Spacious input/output
and distribution cable access
> No rear access required > Top or bottom cable entry

Options

> Remote power management modules


> Start-up service

Dimensions, PMM30

> HxWxD 72.3 x 41.0 x 20.6 in.


> Weight (208/120 Vac, 84 poles) 675 lb.

Dimensions, PMM300

> HxWxD 72.3 x 41.0 x 20.6 in.


> Weight (480 V, 84 poles) 3,365 lb.

For more information: www.apc.com 23


Management Options and Cards

Each UPS is equipped with internal slots to accommodate


several types of communications cards. See the
compatibility matrices on the next page to determine if
these cards are supported for your UPS.

MGE Network Management Card


(66074, 66123, 66124)

66074 66123 66124

> Web server and email notification


> Enterprise Power Manager for UPS monitoring
> Network shutdown module for server protection
> InfraStruxure Central with “MGE” discovery file
> SNMPv1/IPv4
> Optional environmental sensor
(part number 66846)
> Alarm and event logs
> Event log stores up to 500 events
> Remote access from any computer
> Notify up to 50 computers of the UPS
status (up to 35 for 66123 and 66124)
> Teleservice modem (66124 only)
> Modbus RS485 (66123 only)
High-Voltage Relay Cards (Dry Contacts)
(66069)
Modbus RTU over RS485 Card
(66061)
Teleservice Card
(66096, 66097)
MultiSlot Communications Card Expander
(66071)
> 1 acquisition card (part number 66063)
> Up to 3 communication cards (transverse format) for versatility

24
UPS Network Management Card 2
(AP9630/AP9631/AP9635)

AP9630 AP9631 AP9635

> Web server and email notification


> PowerChute™ network shutdown
> InfraStruxure Central compatible
> SNMPv1/SNMPv3
> IPv4/IPv6
> Temperature sensor (AP9631/AP9635 only)
> Alarm, event, and data logs
> Event log stores up to 1,500 events
> Remote access from any computer
> Teleservice modem (AP9635 with select Galaxy UPS only)
> Modbus RS485 (AP9635 only)
> Notify up to 50 computers of the UPS status
SmartSlot Expansion Chassis
(AP9600)
SmartSlot Triple Expansion Chassis
"1#-,

SmartSlot Interface Expander


(AP9607)
SmartSlot Relay I/O Card
(AP9610)
SmartSlot Measure UPS 2
(AP9612TH)
SmartSlot Building Management Interface Card
(AP9622)

For more information: www.apc.com 25


Compatibility Matrices for
Management Options and Cards
Galaxy 3500, Smart-UPS VT, Symmetra

InfraStruxure
SmartSlot Cards Galaxy 3500 Smart-UPS VT
20 kW AIO

Expansion chassis
X X X
> AP9600

Triple expansion chassis


X X X
>"1#-,

Interface expander
X X X
> AP9607

Relay I/O
X X X
> AP9610

Measure UPS 2
X X X
> AP9612TH

#VJMEJOHNBOBHFNFOUJOUFSGBDF
X X X
> AP9622

UPS NMC2
> AP9630 X X X
> AP9631

Symmetra
Symmetra Symmetra
SmartSlot Cards PX 250/ Galaxy VM
PX 40 PX 100
500

Expansion chassis
X X
> AP9600

Triple expansion chassis


X X
>"1#-,

Interface expander
X X
> AP9607

Relay I/O
X X
> AP9613

Measure UPS 2
X X
> AP9612TH

#VJMEJOHNBOBHFNFOUJOUFSGBDF
X X
> AP9622

UPS NMC2
> AP9630 X X
> AP9631

UPS NMC2
X X
> AP9635

Dry contact relay I/O


X
> AP9810

Symmetra MW does not support SmartSlot accessories.

26
EPS, Epsilon, Galaxy

EPS
SmartSlot Cards 6000, 7000, Epsilon STS Galaxy 4000 Galaxy 5000
8000

Modbus
X X X
> 66061

Relay
X X X
> 66069

Ethernet
X* X X X
> 66074

Teleservice modem
X X X
> 66096

Teleservice modem
X
> 66097

*To use the Ethernet card 66074 with the EPS 6000, 7000, or 8000, the MultiSlot
Communications Card Expander 66071 and the acquisition card 66063 are required.

For more information: www.apc.com 27


StruxureWare for Data Centers
Software Suite

APC™ by Schneider Electric UPS units and secure power


systems are a core component of any architecture designed
for highly critical applications, such as data centers, industry
environments, infrastructure, and buildings.

Intelligent energy management of these systems is enabled


by Schneider Electric EcoStruxure™ integrated hardware
and software system architecture. StruxureWare software
applications and suites are a key element of the EcoStruxure
architecture. StruxureWare software helps maximize system
reliability and optimize operational efficiency.

StruxureWare for Data Centers software collects and


manages real-time information about assets, resource use,
and operation status throughout the data center life cycle.
This data center infrastructure management (DCIM) software
fully integrates your three-phase power equipment. With
full system visibility, managers can monitor and apply this
information in order to optimize data center performance to
meet IT-, business-, and service-oriented goals.

28
A Comprehensive Portfolio of Services

Schneider Electric Critical Power & Cooling Services (CPCS)


provides the highest quality services and solutions by
trained and trusted professionals. Our world-class services
offer a smart way to build, operate, and maintain your
critical applications, ensuring the right people, in the right
place, at the right time.

For more information: www.apc.com 29


A Comprehensive Portfolio of Services
(continued)

Assembly and Start-Up Service


Assembly and Start-Up Service by a certified Field Service Engineer
(FSE) ensures full factory warranty coverage. A Schneider Electric-
certified installation of your solution ensures your equipment is
properly and safely configured for optimal performance. This service
features a standard eight-hour, five-day response time, with upgrades
available for off-business hours.

Advantage Plans
Flexible service packages offer hassle-free system maintenance
to improve uptime at a predictable cost. These packages provide
your system with the care it needs to operate most efficiently while
minimizing downtime. The Advantage Plus, Prime, Ultra, and Max
are full-service packages that include technical support, preventive
maintenance, quick on-site response, and remote monitoring.
Response time upgrades are available.

Remote Monitoring Service (RMS)


RMS is an economical and easy-to-use Web-based service that
lets you quickly respond to environmental or system changes.
Trained technicians provide secure 24-hour monitoring of your
physical infrastructure to diagnose and resolve problems before
they become critical.

Preventive Maintenance
Preventive Maintenance on-site examinations of your critical systems
are designed to prevent problems before they occur and keep your
system running at maximum efficiency.

On-Site Warranty Extension Service


In the event of a system issue, an FSE will arrive on-site by the next
business day to isolate, diagnose, and correct the problem in as
little time as possible, minimizing downtime. Upgrades to even faster
response times are available.

30
Other Available Services

The following services may be purchased to supplement


your service contract or as stand-alone services.

Response Time Upgrade


Any on-site warranty extension or Advantage Plan contract can be
upgraded to an eight-hour or four-hour on-site response. Check with
your service sales rep to confirm availability in your location.

Battery Services
#BUUFSZTFSWJDFBOESFQMBDFNFOUBSFWJUBMDPNQPOFOUTPGBOZ614
maintenance program since one failed battery can compromise
an entire system. Whether you need to replace one or all of your
batteries, we can ensure that they are a reliable backup. In addition,
we can provide safe and efficient removal, shipping, and recycling
of your expired batteries, adhering to all federal, state, and local
environmental regulations.

Monitoring Services
Experienced remote monitoring professionals provide 24-hour
monitoring of your system. As a second set of eyes, they can help
you diagnose problems before they become critical and, if required,
promptly dispatch a certified Field Service Engineer on-site.

Capacitor and Fan Replacement Services


These services ensure proactive replacement of capacitor bank and
fans in order to optimize the operation of your product. Also included
is the environmentally friendly disposal of the replaced capacitors or
fans. Labor and travel are included, parts are billed separately.

Extended Operator Training


Provides more in-depth training than what is provided at the time of
system start-up.

Orientation and Training Service


Comprehensive training designed to increase your operator’s
knowledge of the product. It includes both classroom and hands-on
training, as well as solutions management training. Contact your
service sales rep to determine if it is available for your product.

For more information: www.apc.com 31


To learn more about APC by Schneider Electric
solutions, visit www.apc.com

Try our FREE, Web-based applications to


experiment with virtualization, efficiency, and
more at tools.apc.com

APC by Schneider Electric Corporate Headquarters


'BJSHSPVOET3PBE 8FTU,JOHTUPO 3*64"

©2013 Schneider Electric. All Rights Reserved. Schneider Electric,


APC, NetShelter, Smart-UPS, PowerChute, Symmetra, MGE, Galaxy,
EcoStruxure, SturxureWare, and InfraStruxure are trademarks owned
by Schneider Electric Industries SAS or its affiliated companies. All
PUIFSUSBEFNBSLTBSFUIFQSPQFSUZPGUIFJSSFTQFDUJWFPXOFSTt1SPEVDU
specifications are subject to change without notice and are provided
“as is” without warranty of any kind, express or implied. See www.apc.com
GPSUIFNPTUVQUPEBUFQSPEVDUTQFDJýDBUJPOTt@)[@(."64

You might also like