Hvac Emea Solutions Guide: Back To Home Back To Family
Hvac Emea Solutions Guide: Back To Home Back To Family
FAMILY HOME
Page Page
HVAC EMEA
Solutions
Guide
Capacity (kW)
Heating Only
25 50 100 150 300 450 600 750 900 1050 1200 1350 1500 1650 1800 1950
Standard units
Modular units
0 1 2 3 4 5 6 7 8 9 10 11 12 13
Cooling only
Cooling Capacity (kW)
20 40 60 80 100 120 140
Water-Cooled Chillers
Absorption Chillers
Single-effect
Double-effect
Chilled-water Building
Hydronic Fan Coil
plan control Management
Systems Controllers
System System
Literature
30RB
Literature
30RBY
Company Restricted Information
30RBS Series Air Cooled Chillers with Scroll Compressor(s)
11 sizes – 40 to 160 kW
Literature
HEATING Unit – Option 150
Control on water leaving condenser temperature.
Company Restricted Information
30XW Series Water Cooled Chillers with Screw Compressor(s)
31 sizes – 275 to 1765 kW
1055 to 1934 kW
Literature
8 sizes – 5 to 11,5 kW
38AW
Literature
80AW
Company Restricted Information
30AWH Series Air to Water Heat Pump with Scroll Compressor(s)
5 sizes – 4 to 15 kW
Literature
Literature
Literature
Literature
Literature
Modular Units
Literature
MAIN OPTIONS
Literature
MAIN OPTIONS
• AC multi speed (5 speeds) or LEC motor variable speed 0-100%.
• Optimized air flow diffusion / easy integration of its aesthetic cabinet design
• PTC Electric Heaters self regulating based on the air flow, improving comfort and safety.
• Large water valve choice, customized solution ready to use: 2 way or 4 ways valves, 230V or 24V and
On/Off or Modulating actuators.
• New anti-condensate shell insulation of valve body guarantees simplicity and safety.
• Wilde range of controllers: Thermostats (AC or EC), Master/Salve (HDB), Aquasmart (NTC)
Literature
MAIN OPTIONS
• AC multi speed (3 speeds) or LEC motor variable speed 0-100%.
• Electrical box & water valves accessible from same side
• Optimized 4 way air flow diffusion / easy integration of its aesthetic grill design
• Large water valve choice, customized solution ready to use: 2 way or 4 ways valves, 230V or 24V and
On/Off or Modulating actuators.
• New anti-condensate shell insulation of valve body guarantees simplicity and safety.
• Wilde range of controllers: Thermostats (AC or EC), Master/Salve (HDB), Aquasmart (NTC)
Literature
MAIN OPTIONS
Literature
MAIN OPTIONS
Literature
Corridor (LEC)
MAIN OPTIONS
Literature
Centralized (LEC)
MAIN OPTIONS
Literature
Centralized (LEC)
MAIN OPTIONS
Literature
Literature
Up to 4200 kW
Literature
An advanced numeric control system. The new backlighted LCD interface includes
Combining complex intelligence with great operating a manual control potentiometer to ensure
simplicity legibility under any lighting conditions. Pro-Dialog Plus interface
The information is displayed clearly in
Constantly monitors all machines parameters and English, French, German, Italian and Spanish
safety devices and precisely manages the operation of (for other languages please consult Carrier).
compressors, fans and water pump. The Pro-Dialog+ navigation uses intuitive
PID control algorithm anticipates load variations, tree structure menus, similar to the Internet
guarantees leaving water temperature stability and navigators.
prevents unnecessary compressor cycling. They are user-friendly and permit quick
The long stroke electronic expansion valves (EXV) and access to the principal opera-ting parameters:
PID superheat control, together with the head pressure
control algorithm, improve energy efficiency at part load
number of compressors operating,
suction/discharge pressure, compressor
Pro-Dialog + interface
conditions and optimise unit operation. operating hours, set point, air temperature,
Automatic reset of the chilled-water temperature set entering/leaving water temperature.
point for optimised power consumption. Several capacity
loading possibilities for improved start-up at low outdoor
temperature and use of one refrigerant circuit as back- Energy management
up.
Provides preventive protection and enhanced unit Seven-day internal time schedule clock: Pro-Dialog
reliability. permits unit on/off control and operation at a touch screen interface
Equalisation of operating time and number of second set point.
compressor start-ups. Set point reset based on the outside air
Monitors all safety parameters. Fault history function temperature or the return water temperature
and 80 fault code for immediate fault location. Parallel or on the water heat exchanger delta T.
control of two units as standard. Master/slave control of two units operating
Extensive remote control capabilities allow integration in parallel with operating time equalisation
into building management systems. and automatic changeover in case of a unit
RS-485 serial port for connection to the Carrier fault (accessory). Touch Pilot
Comfort Network and any other monitoring system Change-over based on the outside air Operator interface
(through gateways). temperature.
Literature
Company Restricted Information
Electronic Fan Coil Controllers
thermostats
FEATURES Operator Interfaces
Fan operation - With the fan speed selector, fan mode can be set either The Carrier electronic thermostats are designed to
manually or automatically. In the manual mode it is possible to select three fan control and optimise the operation of hydronic
speeds (low/medium/high) according to personal preference. In the auto mode fan terminal fan coil
speed is regulated by a microprocessor in the control, based to the temperature units. They exist in two versions that match all
chosen. terminal fan coil configurations:
Temperature selector - This is designed to maintain the temperature at the
desired level. The reference value at the centre of the range is 20°C. By turning
the knob towards the symbol (-) the temperature is reduced from the original
setting (minimum value is 10°C). By turning the knob towards the symbol (+), the
temperature is raised from the original setting (maximum value is 30°C).
Energy saving mode - This function is especially useful when air conditioning at
night or in rooms where the user is likely to be absent for a longer period of time.
In this case, pushing the button raises the temperature during cooling by 4°C and
lowers it during heating by 4°C.
Seasonal changeover
Manual - Selection of heating/cooling is done manually by pushing the A B
button on the control.
Centralised (only for type A control) - Centralised seasonal changeover
is possible in two ways:
by a switch located on the central control panel that allows
heating/cooling mode changeover (to be provided by the installer).
by a temperature sensor located in contact with the entering water pipe
- Automatic, based on air temperature (only for type B control) – The
automatic seasonal changeover allows automatic switching of the fan coil
operating mode to cooling or heating, depending on the temperature set
by the user and on the room temperature.
External contact - The control has a 230 V input that can be used as window
contact or presence detector. When such a signal is activated (presence of line
voltage on the terminal block contact) the control is set to OFF mode. As a
consequence, all outputs (fan, valves etc.) are disconnected, and only frost
protection is active, if switched ON by the appropriate dip-switch.
Frost-protection - This function keeps the temperature from dropping below 7°C
in rooms not used for long periods of time. Company Restricted Information
HDB Fan Coil Controllers
Controllers
COMFORT VIEW
Powerful supervision software package that allows centralised
monitoring (local and remote), data collection, report generation
and system configuration.
Designed to run on most PCs running on Windows 2000 or
Windows XP.
Designed for larger scale building management needs with
custom graphical Representation.
COMFORT CONTROLLER
Field-installed device which allows non-Carrier equipment such
as boilers, cooling towers and pumps to be controlled and
integrated into the overall network.
Fully programmable to suit the application need and optimized
control strategies..
48UA units are packaged rooftop cooling units, CCN/JBus, Lon or BACnet gateways
factory fitted with a multistage gas heater.
R410A Refrigerant
Cu/Alu coils
MAIN OPTIONS* / ACCESSOIRES**
Axial “Flying Bird” fans
Natrural gas or propane gas modules
Cabinet made of powder-painted sheet metal.
various capacities*
Compressors are hermetic scroll compressors
Various coil protection options*
and mounted on vibration isolators.
Fresh-air sliding panel*
Crankcase heaters are standard for all units.
Manual outdoor air damper*
Gas heating system designed as an alternative
Economizer, thermostatic or enthalpy control,
to the hot water coil or electric heating options.
with or without CO2 sensor control*
Units are available with three gas heating
Supply fan with various high static pressure
modules.
options with or without soft starter*
Tubular dimpled gas heat exchanger optimises
Standard supply fan *
heat transfer for maximum efficiency.
Various filter options*
Modular burner assembly consists of a series of
Stainless steel drain pan*
injectors.
Energy recovery module*........................
Induced draft combustion system for improved
Various return/exhaust air options*
efficiency.
Various temperature sensor options*
Integrated gas unit controller (IGC).
Dirty filter detection*
Supply air flow detection*
DIMENSIONS Smoke detector* / Fire thermostat*
Duct connection fixing frame*
Length (mm): 2125 - 3581
Roof curb**
Width (mm): 2193
Transition roof curb (French ERP)**
Height (mm): 1413 -1825
Remote user interface (Pro-Dialog+)**
Literature
Company Restricted Information
48UH Series Packaged RoofTop Heat Pump + GAS HEATING
48UA units are packaged rooftop cooling units, CCN/JBus, Lon or BACnet gateways
factory fitted with a multistage gas heater.
R410A Refrigerant
Cu/Alu coils
MAIN OPTIONS* / ACCESSOIRES**
Axial “Flying Bird” fans
Natrural gas or propane gas modules
Cabinet made of powder-painted sheet metal.
various capacities*
Compressors are hermetic scroll compressors
Various coil protection options*
and mounted on vibration isolators.
Fresh-air sliding panel*
Crankcase heaters are standard for all units.
Manual outdoor air damper*
Gas heating system designed as an alternative
Economizer, thermostatic or enthalpy control,
to the hot water coil or electric heating options.
with or without CO2 sensor control*
Units are available with three gas heating
Supply fan with various high static pressure
modules.
options with or without soft starter*
Tubular dimpled gas heat exchanger optimises
Standard supply fan *
heat transfer for maximum efficiency.
Various filter options*
Modular burner assembly consists of a series of
Stainless steel drain pan*
injectors.
Energy recovery module*........................
Induced draft combustion system for improved
Various return/exhaust air options*
efficiency.
Various temperature sensor options*
Integrated gas unit controller (IGC).
Dirty filter detection*
Supply air flow detection*
DIMENSIONS Smoke detector* / Fire thermostat*
Duct connection fixing frame*
Length (mm): 2125 - 3581
Roof curb**
Width (mm): 2193
Transition roof curb (French ERP)**
Height (mm): 1413 -1825
Remote user interface (Pro-Dialog+)**
Literature
Company Restricted Information
Energy Recovery Module (option)
For Packaged Roof Top units
FEATURES
The ERM is dual-flow individual unit equipped with a high-efficiency air-to-air Eurovent certified heat recovery wheel (efficiency
63% to 88%), with integrated variable air volume plug fan and a control system for a plug & play installation.
The modules are especially designed to ensure economical extraction of indoor air and taking in fresh air to meet current and
future requirements for high energy efficiency buildings
Single Effect
Company Restricted Information
16 DJ series Direct-Fired Absorption Chiller/Heaters
352 to 5274 kW (23 units ) SUPER ABSORPTION
FEATURES
• Twenty-three sizes with nominal cooling capacities from 352 to
5274 kW and heating capacities from 268 to 4026 kW.
• The 16DJ absorption chillers/heaters offer building owners a better
solution for many new and retrofit applications. Installation of a
direct-fired chiller/heater eliminates the need for a boiler, reducing
the initial cost of the system.
• Excellent for peak shaving during high electrical demand periods.
• Allows diversification of critical cooling requirements. Critical loads
are met with minimal electrical power input.
• Allows use of smaller emergency generators since the electrical
load associated with an absorption chiller is minimal.
• Ozone-friendly and CFC-free.
• Minimises global warming effect by greatly reducing power
consumption.
• Reduced noise and vibration levels. The absorption chiller does not
use a large motor-compressor, leading to quiet, vibration-free
operation.
• Small footprint. The high efficiency associated with double-effect
chillers results in reducing the required installation space.
• Auto-diagnosis system monitors operating conditions, predicts
chiller information and maintains stable operation.
• Advanced high-precision control system.
• Absorption pump with inverter control for efficient, energy-saving
operation.
• High-performance purge system minimises maintenance
requirements.
• State-of-the-art protection devices guarantee enhanced operating
Literature safety.
Double Effect
Company Restricted Information
16 NK series Steam-Fired Absorption Chiller
345 to 4652 kW (18 units ) SUPER ABSORPTION
FEATURES
Eighteen sizes with nominal cooling capacities from 345 to 4652 kW.
• The 16NK absorption chillers are designed for cooling applications
where low-pressure steam is available as waste heat.
• Can tie into district steam systems.
• Allows diversification of critical cooling requirements. Critical
cooling loads are met with minimal electrical power input.
• Allows use of smaller emergency generators since the electrical
load associated with an absorption chiller is minimal.
• Ozone-friendly and CFC-free.
• Minimises global warming effect by greatly reducing power
consumption and eliminating the generation of greenhouse gases.
• Reduced noise and vibration levels. The absorption chiller does not
use a large motor-compressor, leading to quiet, vibration-free
operation.
• Small footprint. The high efficiency associated with double-effect
chillers results in a reduction of the required installation space.
• Auto-diagnosis system monitors operating conditions, predicts
chiller information and maintains stable operation.
• Advanced high-precision control system.
• Absorption pump with inverter control for efficient, energy-saving
operation.
• High-performance purge system minimises maintenance
requirements.
• State-of-the-art protection devices guarantee enhanced operating
safety.
Literature
Double Effect
Company Restricted Information
80HMA Comfort Module range for Monobloc Heat Pumps
5 sizes – 4 to 20 kW
Single zone module
BENEFITS
Peace of mind
MAIN FEATURES - Complete system from one single manufacturer
Single zone comfort module: - Fully programmable thermostat & child lock
Control back up and booster heater (built in EH or - Simple and Limited control settings
Boiler) - 2 zones systems made easy
Control up to 8x30AWH inverter heat pump with bus - Product made in Europe with Nationwide service
communication Savings
Third party remote control connections with dry - System using energy efficient inverter HP
contacts - High system integration for proper HP control 8 liters expansion vessel
Compatible with solar thermal DHW - DHW available all year round, connectable to solar Manometer
Control diverting valve for DHW - Limited installation time Pressure switch
- Widely available spares 10 liters buffer tank
Reversible or heating only
Electrical heater
Single or three phase booster EH Comfort
Moving elec panel
10 liter buffer tank - Constant monitoring of outdoor weather conditions
User interface
Expansion vessel - Fully programmable thermostat & child lock LWT Temperature sensor
2 zones kit: - Product made in Europe with Nationwide service Boiler water connections
Water-source
Heat Pump