0% found this document useful (0 votes)
217 views76 pages

Hvac Emea Solutions Guide: Back To Home Back To Family

This document appears to be a solutions guide for HVAC products made by a company. It includes information on various HVAC equipment types such as air to water heat pumps, air cooled chillers, fan coil units, packaged rooftop units, and industrial water cooled chillers. For each product type, it lists available capacities and dimensions, main features, efficiency ratings, and communication capabilities. It also includes product literature sheets for specific air to water heat pump and air cooled chiller models.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
217 views76 pages

Hvac Emea Solutions Guide: Back To Home Back To Family

This document appears to be a solutions guide for HVAC products made by a company. It includes information on various HVAC equipment types such as air to water heat pumps, air cooled chillers, fan coil units, packaged rooftop units, and industrial water cooled chillers. For each product type, it lists available capacities and dimensions, main features, efficiency ratings, and communication capabilities. It also includes product literature sheets for specific air to water heat pump and air cooled chiller models.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 76

BACK TO BACK TO

FAMILY HOME
Page Page

HVAC EMEA
Solutions
Guide

MBr-12/21/2012 Company Restricted Information


Cooling Capacity (kW)
5 10 25 50 100 150 300 450 600 750 900 1050 1200 1350 1500 1650

Company Restricted Information


Cooling Capacity (kW)
25 50 100 150 300 450 600 750 900 1050 1200 1350 1500 1650 1800 1950

Company Restricted Information


Cooling Capacity (kW)
0 5 15 30 45 60 75 90 105 120 135 150 165

Company Restricted Information


Air to Water Heat Pumps

Capacity (kW)

5 10 25 50 100 150 300 450 600

Heating Only

Company Restricted Information


Water to Water Heat Pumps

Cooling Capacity (kW)

25 50 100 150 300 450 600 750 900 1050 1200 1350 1500 1650 1800 1950

Company Restricted Information


Air Treatment

Air Handling Units

Air flow (m3/h)


500 2 000 8 000 32 000 128 000

Standard units

Standard units with energy recovery


& control system

Modular units

0,14 0,56 2,24 8,96 35,8 Air flow (m3/s)

Company Restricted Information


Air Conditioning Heating Air Treatment Industrial System & Controls

Fan Coils Units

Total Cooling Capacity (kW)

0 1 2 3 4 5 6 7 8 9 10 11 12 13

All Carrier TFCU are


Eurovent Certified

Centralized 100/300Pa (LEC)

Centralized 100/300Pa (LEC)

Company Restricted Information


Air Conditioning Heating Air Treatment Industrial System & Controls

Packaged Rooftop units

Cooling only
Cooling Capacity (kW)
20 40 60 80 100 120 140

Company Restricted Information


Air Conditioning Heating Air Treatment Industrial System & Controls

Air Handling Units Fan Coils Units Packaged Rooftop units


Reversible
Cooling Capacity (kW)
20 40 60 80 100 120 140

Company Restricted Information


Industrial

Water-Cooled Chillers

Cooling Capacity (kW)


1000 2000 3000 4000 5000 6000

Company Restricted Information


Industrial

Absorption Chillers

Cooling Capacity (kW)


500 1000 2000 3000 4000 5000

Single-effect

Double-effect

Company Restricted Information


System & Controls

Chilled-water Building
Hydronic Fan Coil
plan control Management
Systems Controllers
System System

Company Restricted Information


30AWH Series Air to Water Heat Pump with Scroll Compressor(s)
5 sizes – 3 to 16 kW

MAIN FEATURES SOUND


 R410A Refrigerant  Sound Power 64 – 68 dB(A)
 DC Inverter twin-rotary compressor
 Water Plates evaporator
 Variable speed fans control
 Variable Water Flow (optional)
 Compact and small foot print unit

EFFICIENCY COMMUNICATION CAPABILITIES


 Average EER > 2,9 ESEER = 4,4  LonTalk
 Eurovent certified  Modbus
 BaCnet

DIMENSIONS MAIN OPTIONS


 Length (mm): 350 • Integrated hydronic module
 Width (mm): 908 • Variable Water Flow
 Height (mm): 821 - 1363 • Additional outdoor sensor
• Remote controler

Literature

Company Restricted Information


30RB Series Air Cooled Chillers with Scroll Compressor(s)
4 sizes – 17 to 33 kW

MAIN FEATURES SOUND


 R410A Refrigerant  Sound Power 72 – 78 dB(A)
 Cu/Alu coils  Low sound level / super low sound operation
 Water Plates evaporator
 Axial “Flying Bird” fans
 Variable Water Flow (optional)

EFFICIENCY COMMUNICATION CAPABILITIES


 Average EER > 3,15 ESEER = 3,6  LonTalk
 Eurovent certified  Modbus
 BaCnet

DIMENSIONS MAIN OPTIONS


 Length (mm): 522 - 824 • Low ambient temperature down to -10°C
 Width (mm): 1002 – 1136 • Low sound level operation
 Height (mm): 1580 - 1790 • Integrated hydronic module
• Hydronic module antifreeze protection
• Condenser coil treatments
• Smooth or screwed customer connections
• 30RBY Ducted Version up to 160-200Pa

30RB
Literature
30RBY
Company Restricted Information
30RBS Series Air Cooled Chillers with Scroll Compressor(s)
11 sizes – 40 to 160 kW

MAIN FEATURES SOUND


 R410A Refrigerant  Sound Power 80 – 90 dB(A)
 Cu/Alu coils  Low sound level / super low sound operation
 Electronic expansion valve
 Water Plates evaporator
 Axial “Flying Bird” fans
 Variable Water Flow (optional)

EFFICIENCY COMMUNICATION CAPABILITIES


 Average EER > 2,9 ESEER up to 4  LonTalk
 Eurovent certified  Modbus
 BaCnet

DIMENSIONS MAIN OPTIONS


 Length (mm): 2071 • Low ambient temperature down to -20°C
 Width (mm): 1081 - 2278 • Low sound level operation
 Height (mm): 1329 • Integrated hydronic module (6 versions)
• Hydronic module antifreeze protection
• Condenser coil treatments
• Soft starter (up to 80kW)
• Smooth or screwed customer connections
• Ducted Version up to 160-200Pa
30RBS • Partial Heat Recovery (Coming soon)
Literature • 30RBSY Ducted Version up to 160-200Pa
30RBSY
Company Restricted Information
30RB Series Air Cooled Chillers with Scroll Compressor(s)
15 sizes – 163 to 760 kW

MAIN FEATURES SOUND


 R410A Refrigerant  Sound Power 84 – 94 dB(A)
 Alu/Alu coils  Low sound level / super low sound operation
 DX evaporator
 Axial “Flying Bird” fans

EFFICIENCY COMMUNICATION CAPABILITIES


 EER up to 3 ESEER up to 4,1  LonTalk
 Eurovent certified  Modbus
 BaCnet
 Energy Management Module EMM (easy
connection to building managment system)

DIMENSIONS MAIN OPTIONS


 Length (mm): 2410 – 7186 • Condenser coil treatments
 Width (mm): 2253 • LWT down to -10°C / High static fan
 Height (mm): 2297 • Grilles & side panels / Gateways
• Low ambient temperature down to -20°C
• Integrated hydronic module (4 versions)
• Hydronic module antifreeze protection
• Soft starter (up to 500kW)
• Total Heat Recovery
Literature • Partial Heat Recovery
• Direct Expansion Free Cooling
• Ducted option 12 up to 160-200Pa
Company Restricted Information
30XAS Series Air Cooled Chillers with Screw Compressor(s)
5 sizes – 235 to 482 kW

MAIN FEATURES SOUND


 R134a Refrigerant  Sound Power 94 – 98 dB(A)
 Alu/Alu coils  Low sound level & super low sound versions
 Economizer with EXV on all the range available
 Flooded evaporator
 Axial “Flying Bird” fans

EFFICIENCY COMMUNICATION CAPABILITIES


 Standard & High Efficiency range  LonTalk
 EER up to 3,2 ESEER up to 4  Modbus
 Eurovent certified  BaCnet
 Energy Management Module EMM (easy
connection to building managment system)

DIMENSIONS MAIN OPTIONS


 Length (mm): 2410 – 4798 • Condenser coil treatments
 Width (mm): 2253 • LWT down to -12°C / High static fan
 Height (mm): 2297 • Grilles & side panels / Gateways
• Low ambient temperature down to -20°C
• High ambient operation up to 55°C
• Integrated hydronic module
• Hydronic module antifreeze protection
• Touch screen interface
Literature • Total Heat Recovery

Company Restricted Information


30XA Series Air Cooled Chillers with Screw Compressor(s)
20 sizes – 252 to 1700kW

MAIN FEATURES SOUND


 R134a Refrigerant  Sound Power 89 – 101 dB(A)
 Alu/Alu coils  Low sound level & super low sound versions
 Economizer with EXV on all the range available
 Flooded evaporator
 Axial “Flying Bird” fans

EFFICIENCY COMMUNICATION CAPABILITIES


 Standard & High Efficiency range  LonTalk
 EER up to 3.2 ESEER up to 4.2  Modbus
 Eurovent certified , class A  BaCnet
 Energy Management Module EMM (easy
connection to building managment system)

DIMENSIONS MAIN OPTIONS


 Length (mm): 3604 – (9574+4798) • Condenser coil treatments
 Width (mm): 2253 • LWT down to -12°C / High static fan
 Height (mm): 2297 • Grilles & side panels / Gateways
• Low ambient temperature down to -20°C
• High ambient operation up to 55°C
• Integrated hydronic module (4 versions)
• Hydronic module antifreeze protection
• Touch screen interface
Literature • Total Heat Recovery
• Direct Expansion Free Cooling

Company Restricted Information


30WG Series Water Cooled Chillers with Scroll Compressor(s)
11 sizes – 24 to 95 kW

MAIN FEATURES SOUND


 11 sizes with scroll compressors  Sound Power 67 – 73 dB(A)
 R410A refrigerant  Low sound level (-3dB(A) option available
 Plates exchangers
 Designed for cooling to LWT -12°C (option)
 Compact with small footprint

EFFICIENCY COMMUNICATION CAPABILITIES


 EER up to 4,8 classe B  LonTalk
 ESEER up to 5,4  Modbus
 Eurovent certified  BaCnet
 Remote control option

DIMENSIONS MAIN OPTIONS


 Length (mm): 1044 – 1477 • LWT down to -12°C
 Width (mm): 600 - 8805 • Gateways
 Height (mm): 901 • Soft starter
• Low/High pressure single-pump hydronic module.
• Remote user interface
• Unit stackable for operation.
• Customer water connections at the top of the unit.
•Twinning ( master/slave operation)
Literature • Variable flow pump

Company Restricted Information


30RW- Series Water Cooled Chillers with Scroll Compressor(s)
10 sizes – 110 to 300 kW

MAIN FEATURES SOUND


 10 sizes with scroll compressors  Sound Power 94 – 104 dB(A)
 R407c refrigerant
 Plates exchangers
 Designed for cooling to LWT -10°C (option)
 19 sizes condenserless 30RWA 20-300 kW

EFFICIENCY COMMUNICATION CAPABILITIES


 EER up to 4,5 ESEER up to 5,4  LonTalk
 Eurovent certified  Modbus
 BaCnet
 Energy Management Module EMM (easy
connection to building managment system)

DIMENSIONS MAIN OPTIONS


 Length (mm): 2004 – 2950 • LWT down to -10°C
 Width (mm): 895 - 922 • Gateways
 Height (mm): 1750 to 1993 • Heat machine (not reversible)
• Soft starter
•Hydronic modules with single or twin pumps
•Gateways
•Variable flow condenser pump.

Literature HEATING Unit – Option 150


Control on water leaving condenser temperature.

Company Restricted Information


30HXC Series Water Cooled Chillers with Screw Compressor(s)
17 sizes – 286 to 1300 kW Global Chiller

MAIN FEATURES SOUND


 R134a Refrigerant  Sound Power 94 – 104 dB(A)
 Flooded evaporator
 Compactness
 Dual independent refrigerant circuits

EFFICIENCY COMMUNICATION CAPABILITIES


 EER up to 5 ESEER up to 5,6  LonTalk
 Eurovent certified  Modbus
 BaCnet
 Energy Management Module EMM (easy
connection to building managment system)

DIMENSIONS MAIN OPTIONS


 Length (mm): 2558 – 4533 • LWT down to -10°C
 Width (mm): 980 - 1015 • Gateways
 Height (mm): 1800 to 2112 • Exchangers with one pass less.
• High condensing water living temp up to 63°C
• Exchangers for 21 bar water side operation.
• Reverse exchangers water boxes facilities
•Pumps electrical power/control facilities
• Service valve set
• Sea water condenser applications

Literature
HEATING Unit – Option 150
Control on water leaving condenser temperature.
Company Restricted Information
30XW Series Water Cooled Chillers with Screw Compressor(s)
31 sizes – 275 to 1765 kW

MAIN FEATURES SOUND


 R134a Refrigerant  Sound Power 95 – 102 dB(A)
 Flooded evaporator  Low sound level (-3dBA)
 Compactness & super low sound (-20dBA) versions available

EFFICIENCY COMMUNICATION CAPABILITIES


 20 sizes standard efficiency range  LonTalk
 11 sizes High Efficiency range 30XW-P  Modbus
 EER up to 5,6 ESEER up to 6,8  BaCnet
 Eurovent certified , class A  Energy Management Module EMM (easy
connection to building managment system)

DIMENSIONS MAIN OPTIONS


 Length (mm): 2742 – 4872 • LWT down to -12°C
 Width (mm): 936 – 1683 (side by side units) • Gateways
 Height (mm): 1693 to 2100 • Exchangers with one pass less.
• High condensing water living temp up to 63°C
• Exchangers for 21 bar water side operation.
• Reverse exchangers water boxes facilities
• Touch screen interface
• Pumps electrical power/control facilities
• Service valve set
Literature
HEATING Unit 30XWH range
Control on water leaving condenser temperature.
Company Restricted Information
30XW-V Series Water Cooled Chillers
with Variable-Speed Screw Compressor(s)

9 sizes – 580 to 1700kW

MAIN FEATURES SOUND


 R134a Refrigerant  Sound Power 99 – 102 dB(A)
 Flooded evaporator  Low sound option available
 Inverter-driven screw compressors
 Compactness
 Units optimised for cooling tower applications

EFFICIENCY COMMUNICATION CAPABILITIES


 9 sizes High Efficiency range  LonTalk
 EER up to 5,6 ESEER up to 8  Modbus
 Eurovent certified , class A  BaCnet
 Energy Management Module EMM (easy
connection to building managment system)

DIMENSIONS MAIN OPTIONS


 Length (mm): 2742 – 4872 • Low noise option
 Width (mm): 936 – 1683 (side by side units) • EMC EN61800-3-C2 compliance, for residential
 Height (mm): 1693 to 2100 applications
• Exchangers with one pass less.
• Exchangers for 21 bar water side operation.
• Reverse exchangers water boxes facilities
• Service valve set

Literature HEATING Unit 30XWHV range


Control on water leaving condenser temperature.

Company Restricted Information


23XRV Series Water Cooled Chillers
with Variable-Speed Screw Compressor(s)

1055 to 1934 kW

MAIN FEATURES SOUND


 R134a Refrigerant  Sound Power 99 – 102 dB(A)
 Flooded evaporator  Low sound option available
 Inverter-driven screw compressors
 Tri-rotor, positive displacement screw compressor
 Low inrush current
 Operation of up to 0.99 power factor

EFFICIENCY COMMUNICATION CAPABILITIES


 High Efficiency range  LonTalk
 EER up to 6, ESEER up to 9  Modbus
 BaCnet

DIMENSIONS MAIN OPTIONS


 Length (mm): 4172 – 5042 • One, 2, or 3 pass cooler or condenser waterside
 Width (mm): 1930 – 2127 construction
 Height (mm): 2200 -- 2305 •Service valve set

Literature

Company Restricted Information


61WG Series Water to Water Heat Pumps with Scroll Compressor(s)
11 sizes – 30 to 116 kW

MAIN FEATURES SOUND


 11 sizes with scroll compressors  Sound Power 67 – 73 dB(A)
 R410A refrigerant  Low sound level (-3dB(A) option available
 Designed for heating with +65°C as highest LWT
 Heat / cool change over with -5°C as lowest
LWT(option)
 Compact with small footprint

EFFICIENCY COMMUNICATION CAPABILITIES


 Cop up to 5,5  LonTalk
 Eurovent certified  Modbus
 BaCnet
 Remote control option
 Heating system manager

DIMENSIONS MAIN OPTIONS


 Length (mm): 1044 – 1477 • LWT down to -5°C (ground source application)
 Width (mm): 600 - 8805 • Gateways
 Height (mm): 901 • Soft starter
• Low/High pressure single-pump hydronic
module.
• Remote user interface
• Unit stackable for operation.
• Customer water connections at the top of the
Literature unit.
•Twinning ( master/slave operation)
• Variable flow pump
Company Restricted Information
38AW / 80AW Air to Water Split System Heat Pump

8 sizes – 5 to 11,5 kW

MAIN FEATURES SOUND


 R410A Refrigerant  Sound Power 64 – 70 dB(A) Outoor units
 DC Inverter twin-rotary compressor  Sound Power 40 Intoor unit
 Variable speed fans control
 Pre-set or customised selection of the
appropriate climate curve for stable output
capacity to match the heat load. EFFICIENCY
 Output to link and integrate the unit with existing
heat sources offers a dual-energy approach.  EER up to 4 - Cop up to 4,2 (CHF)
 Able to control two independent comfort zones.  ESEER up to 4
 Leaving water temperature up to 60°C for  Eurovent certified
radiator and domestic hot water applications.
 Heating mode available from -20°C to +30°C MAIN OPTIONS
• Additional user interface
DIMENSIONS (outdoor units) • Communication kit
• Domestic hot water Tank , one or two coils –
 Length (mm): 320 storage 200/300 liters.
 Width (mm): 900 • Dual Zone Kit
 Height (mm): 690 - 1363 • CDU rubber vibration isolators
• Additional outdoor sensor
• Piping kit to install domestic hot water valve and
acturator inside unit.

38AW
Literature
80AW
Company Restricted Information
30AWH Series Air to Water Heat Pump with Scroll Compressor(s)
5 sizes – 4 to 15 kW

MAIN FEATURES SOUND


 R410A Refrigerant  Sound Power 64 – 68 dB(A)
 DC Inverter twin-rotary compressor
 Water Plates exchanger
 Variable speed fans control
 Variable Water Flow (optional)
 Compact and small foot print unit

EFFICIENCY COMMUNICATION CAPABILITIES


 EER up to 4 - Cop up to 4,2 (CHF)  LonTalk
 ESEER up to 4,5  Modbus
 Eurovent certified  BaCnet

DIMENSIONS MAIN OPTIONS


 Length (mm): 350 • Integrated hydronic module
 Width (mm): 908 • Variable Water Flow
 Height (mm): 821 - 1363 • Additional outdoor sensor
• Remote controler
• Additional confort module 80HMA range ……

Literature

Company Restricted Information


30RQ Series Air to Water Heat Pump with Scroll Compressor(s)
4 sizes – 17 to 33 kW

MAIN FEATURES SOUND


 R410A Refrigerant  Sound Power 72 – 78 dB(A)
 Cu/Alu coils  Low sound level / super low sound operation
 Water Plates exchanger
 Axial “Flying Bird” fans
 Variable Water Flow (optional)

EFFICIENCY COMMUNICATION CAPABILITIES


 EER up to 3,2 - Cop up to 3,8 (CHF)  LonTalk
 ESEER up to 3,9  Modbus
 Eurovent certified  BaCnet

DIMENSIONS MAIN OPTIONS


 Length (mm): 522 - 824 • Low ambient temperature down to -15°C
 Width (mm): 1002 – 1136 • Low sound level operation
 Height (mm): 1580 - 1790 • Integrated hydronic module
• Hydronic module antifreeze protection
• Air coil exchanger treatments
• Smooth or screwed customer connections
• 30RQY Ducted Version up to 160-200Pa
•Additional confort module 80HMA range ……
30RQ
Literature
30RQY
Company Restricted Information
30RQS Series Air Cooled Chillers with Scroll Compressor(s)
12 sizes – 40 to 160 kW

MAIN FEATURES SOUND


 R410A Refrigerant  Sound Power 80 – 90 dB(A)
 Cu/Alu coils  Low sound level
 Electronic expansion valve
 Water Plates exchanger
 Axial “Flying Bird” fans
 Variable Water Flow (optional)

EFFICIENCY COMMUNICATION CAPABILITIES


 EER up to 3,2 - Cop up to 3,8 (CHF)  LonTalk
 ESEER up to 3,9  Modbus
 Eurovent certified  BaCnet

DIMENSIONS MAIN OPTIONS


 Length (mm): 2071 • Low ambient temperature down to -10°C
 Width (mm): 1081 - 2278 • Low sound level operation
 Height (mm): 1329 • Integrated hydronic module (6 versions)
• Hydronic module antifreeze protection
• Condenser coil treatments
• Soft starter (up to 80kW)
• Smooth or screwed customer connections
• Ducted Version up to 160-200Pa
30RQS • Partial Heat Recovery (Coming soon)
Literature • 30RQSY Ducted Version up to 160-200Pa
30RQSY
Company Restricted Information
30RQ Series Air to Water Heat Pump with Scroll Compressor(s)
11 sizes – 189 to 548 kW

MAIN FEATURES SOUND


 R410A Refrigerant  Sound Power 89 – 91 dB(A)
 Cu/Alu coils  Low sound level operation
 DX evaporator / copper multi-tubes exchanger
 Axial “Flying Bird” fans

EFFICIENCY COMMUNICATION CAPABILITIES


 EER up to 2,9 - Cop up to 3,7 (CHF)  LonTalk
 ESEER up to 4  Modbus
 Eurovent certified  BaCnet
 Energy Management Module EMM (easy
connection to building managment system)

DIMENSIONS MAIN OPTIONS


 Length (mm): 2410 – 4798 • Air coil exchanger treatment
 Width (mm): 2253 • Grilles & side panels / Gateways
 Height (mm): 2297 • Low ambient temperature down to -10°C
• Integrated hydronic module (4 versions)
• Hydronic module antifreeze protection
• Soft starter
•Partial Heat Recovery

Literature

Company Restricted Information


61AF Series Heat Pumps with Scroll Compressor(s)
2 sizes – 14 & 19 kW

MAIN FEATURES SOUND


 R407CA refrigerant  Low sound level operation
 Designed for heating with +65°C as highest LWT  Low noise fans made of a composite material
 Heating capability down to -20°C OAT
 Scroll compressor with vapor injection
 Compact with small footprint
Hydronic module in standard with multi-speed
pump

EFFICIENCY COMMUNICATION CAPABILITIES


 COP above 4  LonTalk
 Eurovent certified  Modbus
 Comply with the COP required by Ecolabel  BaCnet
certification

DIMENSIONS MAIN OPTIONS


 Length (mm): 1103 -1135 • Remote user interface
 Width (mm): 333 - 559 • Twinning – Lead lag kit
 Height (mm): 1278 -1579 •Additional confort module 80HMA range ……

Literature

Company Restricted Information


61AF Series Heat Pumps with Scroll Compressor(s)
7 sizes – 21 to 102 kW

MAIN FEATURES SOUND


 R407C refrigerant Low sound level operation
 Designed for heating with +65°C as highest LWT
 Heating capability down to -20°C OAT
 Scroll compressor with vapor injection
 Compact with small footprint

EFFICIENCY COMMUNICATION CAPABILITIES


 COP above 4  LonTalk
 Eurovent certified  Modbus
 Comply with the COP required by Ecolabel  BaCnet
certification  Heating system manager

DIMENSIONS MAIN OPTIONS


 Length (mm): 1327 - 2100 • Low sound / Super low sound level operation
 Width (mm): 1114 - 2273 • Gateways
 Height (mm): 1330 • Soft starter
• Condenser with pre-painted fins
• Hydronic module.
• Remote user interface
• Twinning ( master/slave operation)
• Heating system manager
Literature

Company Restricted Information


38RBS Series Air Cooled Chillers with Scroll Compressor(s)
11 sizes – 40 to 151 kW

MAIN FEATURES SOUND


 R410A Refrigerant  Sound Power 80 – 90 dB(A)
 Cu/Alu coils  Low sound level operation
 Axial “Flying Bird” fans
 Refrigerant circuit includes all compoments for
easy connection to AHU : filter dryer, liquid sight
glass, 2 solenoid valves per circuit.

EFFICIENCY COMMUNICATION CAPABILITIES


 LonTalk
 Modbus
 BaCnet

DIMENSIONS MAIN OPTIONS


 Length (mm): 2071 • Low sound level operation
 Width (mm): 1081 - 2278 • Soft starter
 Height (mm): 1329 • Low ambiant air temperature down to -20°C
• Room adjustable temperature sensor for capacity
control
• Remote interface

Literature

Company Restricted Information


39SQ Air Handling Units _ 1 000 to 30 000 m3/h
Standard Units

MAIN FEATURES MAIN OPTIONS


 Standardised AHU for tertiary & commercial • Outdoor installation.
applications. • Inspection section between heating & colling
 « Clean concept design » with smooth internal coils.
surfaces. • Reversed hot / chilled water coils.
 60mm double-skin construction for good termal • Differential pressure gauges.
insulation and low noise operaton. • Differential pressure taps.
 3 basic configurations: • Direct expansion refrigerant coil ( 25% fresh air)
 Exhaust unit. • Lighting with switch.
 Supply unit with a single fan. • Door safety screen.
 Combined return & supply unit with 2 fans. • Variable-speed drive with integrated disconnect
 8 sizes from 1 000 to 30 00 m3/h. switch..
 Galvanized steel frame & casing with large hingred
acces doors.
 Casing in accordance with EN 1886 standard :
 Air leakage class L2, thermal bridging class
TB3, thermal transmission class T2.
 Double or single mixing section.
 Pre-heating hot water coil.
 G4 oo/ and F7 bag filters.
Hot water coil or electric heatres.
 Chilled water coil.
Belt-driven forward/ backward curced fans or direct-
drive plug-in fans.

Literature

Company Restricted Information


39SQC /R/P Air Handling Units _1 000 to 18 000 m3/h
Plug & Play fresh air handling unit with energy recovery & control system

3 Versions in 9 sizes MAIN FEATURES


•  All units delivered in one piece with : Pre-
39SQC heating coil - Re heating coil - Cooling coil - Air
dampers - Electrical box
• Counter flow plate technology: 700- 3100 m3/h  Large units splitable into two sections on site.
• Very high efficiency up to 90% Hygienic flat surface
• Aluminium plates  Excellent thermal properties 60mm, No thermal
• Outside air by-pass (Free cooling, Capacity bridge
control, Heat exchanger defrost  Casing in accordance with EN 1886 standard :
Air leakage class L1, thermal bridging class
TB3, thermal transmission class T3.
39SQR  Plug fans with variable frequency drive.
 Main control system functions:
• Rotary technology: 1500-18000 m3/h Air flow control
• Very high efficiency up to 86% Temperature control
• Robust construction Summer night free cooling control
• Variable speed drive Alarm indication
Easy local or remote access
RS485 communication port
39SQP Integrated WEB server
Access from any computer
• Cross flow plate technology: 700- 12500 m3/h No specific software required
• Efficiency up to 60%
• Aluminium plates MAIN OPTIONS
• Outside air by-pass (Free cooling, Capacity
control, Heat exchanger defrost • Outdoor or indoor installation.
• Supply duct on bottom or top.
• Left or right hand service side.
Literature

Company Restricted Information


39HQ Air Handling Units _ 1 000 to 110 000 m3/h

Modular Units

MAIN FEATURES MAIN OPTIONS


 Large selection of sizes and arrangements for
• 100% stainless steel
many applications. (122 sizes)
 Modular construction easier to customise. • Direct drive fans
 Rigid construction
• All types of humidification systems, including
Panels with 60mm thick thermal insulation
 Galvanized steel frame treated with a weather infrasonic.
resistant coating on both sides & casing with large
• Heat Recovery systems
hingred acces doors.
 High corrosion resistance • Wide selection of standard accessories.
 Casing in accordance with EN 1886 standard :
• 316L stainless steel drain pan.
Air leakage class L2, thermal bridging class
TB2, thermal transmission class T2. • Flat pack option for site assembly.
 100% recyclabe compoments
 Low energy usage due to optimized compoment
selection.
 Easy maintenance
Various inspection options as generously
sized opening access doors.
Filters easly removable
Drain pan in the outside air inlet section
Long life fan and motor bearings.
 High Quality built-in compoments
 Eurovent certified

Literature

Company Restricted Information


42N (F/P) Fan Coil
Concealed (AC/LEC)

PERFORMANCES MAIN FEATURES


• Total Cooling capacities: 0.83 – 6.35 kW
• ESP : 0 to 40Pa
• Sensible Cooling cap.: 0.70 – 5.10 kW
• One of the more silent unit on the market
• Heating capacities: 1.14 – 9.50 kW
• LEC : Low Energy Consumption motors
• Noise Rating NR: 15 – 54 dB(A)
• All-inclusive offer: minimizing installation cost
• Energy class : AC class D/E ; EC class A with all options factory fitted and tested.

MAIN OPTIONS

• AC multi speed (5 speeds) or LEC motor variable speed 0-100%.


• PTC Electric Heaters self regulating based on the air flow, improving comfort and safety.
• Large water valve choice, customized solution ready to use: 2 way or 4 ways valves, 230V or 24V and
On/Off or Modulating actuators.
• New anti-condensate shell insulation of valve body guarantees simplicity and safety.
• Wilde range of controllers: Thermostats (AC or EC), Master/Salve (HDB), Aquasmart (NTC)

Literature

Company Restricted Information


42N (M/Z) Fan Coil
Console (AC/LEC)

PERFORMANCES MAIN FEATURES


• Total Cooling capacities: 0.83 – 6.35 kW
• The benchmark on the market
• Sensible Cooling cap.: 0.70 – 5.10 kW
• One of the more silent unit on the market
• Heating capacities: 1.14 – 9.50 kW
• LEC : Low Energy Consumption motors
• Noise Rating NR: 15 – 54 dB(A)
• All-inclusive offer: minimizing installation cost
• Energy class : AC class D/E ; EC class A with all options factory fitted and tested.

MAIN OPTIONS
• AC multi speed (5 speeds) or LEC motor variable speed 0-100%.
• Optimized air flow diffusion / easy integration of its aesthetic cabinet design
• PTC Electric Heaters self regulating based on the air flow, improving comfort and safety.
• Large water valve choice, customized solution ready to use: 2 way or 4 ways valves, 230V or 24V and
On/Off or Modulating actuators.
• New anti-condensate shell insulation of valve body guarantees simplicity and safety.
• Wilde range of controllers: Thermostats (AC or EC), Master/Salve (HDB), Aquasmart (NTC)

Literature

Company Restricted Information


42GW Fan Coil
Cassette (AC/LEC)

PERFORMANCES MAIN FEATURES


• Total Cooling capacities: 1.55 – 9.60 kW
• The benchmark on the market
• Sensible Cooling cap.: 1.30 – 7.35 kW
• One of the more silent unit on the market
• Heating capacities: 2.20 – 13.00 kW
• LEC : Low Energy Consumption motors
• Noise Rating NR: 27 – 56 dB(A)
• All-inclusive offer: minimizing installation cost
• Energy class: AC classC/D, EC classA/B with all options factory fitted and tested.

MAIN OPTIONS
• AC multi speed (3 speeds) or LEC motor variable speed 0-100%.
• Electrical box & water valves accessible from same side
• Optimized 4 way air flow diffusion / easy integration of its aesthetic grill design
• Large water valve choice, customized solution ready to use: 2 way or 4 ways valves, 230V or 24V and
On/Off or Modulating actuators.
• New anti-condensate shell insulation of valve body guarantees simplicity and safety.
• Wilde range of controllers: Thermostats (AC or EC), Master/Salve (HDB), Aquasmart (NTC)

Literature

Company Restricted Information


42EM Fan Coil

Ducted Medium (AC/LEC)

PERFORMANCES MAIN FEATURES


• Total Cooling capacities: 0.80 – 7.85 kW
• ESP : 30 to 90Pa
• Sensible Cooling cap.: 0.65 – 5.61 kW
• Best in class sound levels
• Heating capacities: 2.00 – 9.35 kW
• LEC : Low Energy Consumption motors
• Noise Rating NR: 15 – 39 dB(A)
• All-inclusive offer: minimizing installation cost
• Energy class: AC class C/D ; EC class A/B with all options factory fitted and tested.

MAIN OPTIONS

• AC multi speed (6 speeds) or LEC motor variable speed 0-100%


• Easy integration in false ceiling with compact units (high 250mm)
• Return & supply air plenum with multiple spigots choice (diameter 200mm)
• Large choice of factory fitted water valves / Electric heaters
• Wilde range of controllers: Thermostats (AC or EC), Master/Salve (HDB), Aquasmart (NTC)

Literature

Company Restricted Information


42DW Fan Coil

Ducted Large (AC/LEC)

PERFORMANCES MAIN FEATURES


• Total Cooling capacities: 5.08 – 13.70 kW
• Sensible Cooling cap.: 4.00 – 10.60 kW • ESP : 50 to 120Pa
• Heating capacities: 6.74 – 19.60 kW • Best in class sound levels
• Noise Rating NR: 38 – 63 dB(A) • All-inclusive offer: minimizing installation cost
with all options factory fitted and tested.
• Energy class : AC class C/D

MAIN OPTIONS

• AC multi speed (4 speeds)


• Easy integration in false ceiling with compact units (high 285mm)
• Supply air plenum free or multiple spigots choice (diameter 200mm)
• Large choice of factory fitted water valves / Electric heaters
• Wilde range of controllers: Thermostats (AC or EC), Master/Salve (HDB), Aquasmart (NTC)

Literature

Company Restricted Information


42BJ Fan Coil

Corridor (LEC)

PERFORMANCES MAIN FEATURES


• Total Cooling capacities: 0.50 – 6.00 kW
• ESP : 100 to 300Pa
• Sensible Cooling cap.: 0.50 – 12.0 kW
• Best in class sound levels
• Heating capacities: 0.51 – 6.80 kW
• LEC : Low Energy Consumption motors
• Noise Rating NR: 25 – 46 dB(A)
• All-inclusive offer: minimizing installation cost
• Energy class: AC class B/C ; EC class A/C with all options factory fitted and tested.

MAIN OPTIONS

• LEC motor variable speed 0-100%


• Easy integration in centralized zone
• Large choice of factory fitted water valves / Electric heaters / Filters
• Wilde range of controllers: Thermostats (EC), Aquasmart (NTC)

Literature

Company Restricted Information


42GM Fan Coil

Centralized (LEC)

PERFORMANCES MAIN FEATURES


• Total Cooling capacities: 0.50 – 2.80 kW
• ESP : 100 to 300Pa
• Sensible Cooling cap.: 0.30 – 2.20kW
• Best in class sound levels
•Noise Rating NR: 20 – 45 dB(A)
• LEC : Low Energy Consumption motors
• All-inclusive offer: minimizing installation cost
with all options factory fitted and tested.

MAIN OPTIONS

• LEC motor variable speed 0-100%


• Easy integration in centralized zone
• Large choice of factory fitted water valves / Electric heaters
• Wilde range of controllers: Thermostats (EC), Aquasmart (NTC)

Literature

Company Restricted Information


42GR Fan Coil

Centralized (LEC)

PERFORMANCES MAIN FEATURES


• Total Cooling capacities: 1.00 – 3.35 kW
• ESP : 100 to 300Pa
• Sensible Cooling cap.: 0.70 – 2.35 kW
• Best in class sound levels
• Heating capacities: 1.00 – 3.32 kW
• LEC : Low Energy Consumption motors
• Noise Rating NR: 18 – 40 dB(A)
• All-inclusive offer: minimizing installation cost
with all options factory fitted and tested.

MAIN OPTIONS

• LEC motor variable speed 0-100%


• Easy integration in centralized zone
• Large choice of factory fitted water valves / Electric heaters
• Wilde range of controllers: Thermostats (EC), Aquasmart (NTC)

Literature

Company Restricted Information


19XR Series Water Cooled Hermetic Centrifugal Liquid Chiller
1000 to 5300 kW

MAIN FEATURES COMMUNICATION CAPABILITIES


 R134a Refrigerant  LonTalk
 Flooded evaporator  Modbus
 Hermetic compressor motor  BaCnet
 CE Marking Chiller
 PED Heat exchanger certified
 Single Stage compressor
 Mix-match capability Montparnasse
 Microprocessor control with direct digital product Tower
integrated controls Paris

EFFICIENCY MAIN OPTIONS


 High Efficiency range • One, 2, or 3 pass cooler or condenser waterside
 Average EER up to 6,8 construction
• Service valve set
• IP54 protection for control box.
• High voltage motors available
• Tropicalisation
• Evaporator with 21 bar water-side pressure.
Queen
• Unit equipped with soft starter.
Mary II
• Unit with star/delta starting.
• Sea-water/ Marine application
• Customer factory performance testing

Literature

Company Restricted Information


19XRV Series Water Cooled Hermetic Centrifugal Liquid Chiller
With Variable-Speed Frequency Drive Compressor

Up to 4200 kW

MAIN FEATURES COMMUNICATION CAPABILITIES


 R134a Refrigerant  LonTalk
 Flooded evaporator  Modbus
 Hermetic compressor motor  BaCnet
 CE Marking Chiller
 PED Heat exchanger certified  Active rectifier VFD’s No harmonics on network
 Single Stage compressor with variable
frequency drive.
 Mix-match capability
 Microprocessor control with direct digital product
integrated controls

EFFICIENCY MAIN OPTIONS


 High Efficiency range • One, 2, or 3 pass cooler or condenser waterside
 EER up to 5 ESEER up to 7,5 construction
• Service valve set
• IP54 protection for control box.
• High voltage motors available
• Tropicalisation
• Evaporator with 21 bar water-side pressure.
• Sea-water/ Marine application
•Customer factory performance testing

Literature

Company Restricted Information


PRO-DIALOG Chilled-Water Plan Control System

CONTROL FEATURES Operator Interfaces


(Pro-Dialog Plus/Pro-Dialog touch screen)

An advanced numeric control system.  The new backlighted LCD interface includes
Combining complex intelligence with great operating a manual control potentiometer to ensure
simplicity legibility under any lighting conditions. Pro-Dialog Plus interface
 The information is displayed clearly in
 Constantly monitors all machines parameters and English, French, German, Italian and Spanish
safety devices and precisely manages the operation of (for other languages please consult Carrier).
compressors, fans and water pump.  The Pro-Dialog+ navigation uses intuitive
 PID control algorithm anticipates load variations, tree structure menus, similar to the Internet
guarantees leaving water temperature stability and navigators.
prevents unnecessary compressor cycling.  They are user-friendly and permit quick
 The long stroke electronic expansion valves (EXV) and access to the principal opera-ting parameters:
PID superheat control, together with the head pressure
control algorithm, improve energy efficiency at part load
number of compressors operating,
suction/discharge pressure, compressor
Pro-Dialog + interface
conditions and optimise unit operation. operating hours, set point, air temperature,
 Automatic reset of the chilled-water temperature set entering/leaving water temperature.
point for optimised power consumption. Several capacity
loading possibilities for improved start-up at low outdoor
temperature and use of one refrigerant circuit as back- Energy management
up.
 Provides preventive protection and enhanced unit  Seven-day internal time schedule clock: Pro-Dialog
reliability. permits unit on/off control and operation at a touch screen interface
 Equalisation of operating time and number of second set point.
compressor start-ups.  Set point reset based on the outside air
 Monitors all safety parameters. Fault history function temperature or the return water temperature
and 80 fault code for immediate fault location. Parallel or on the water heat exchanger delta T.
control of two units as standard.  Master/slave control of two units operating
 Extensive remote control capabilities allow integration in parallel with operating time equalisation
into building management systems. and automatic changeover in case of a unit
 RS-485 serial port for connection to the Carrier fault (accessory). Touch Pilot
Comfort Network and any other monitoring system  Change-over based on the outside air Operator interface
(through gateways). temperature.

Company Restricted Information


CSM III Chilled-Water plan control system
FEATURES CONTROL FUNCTIONS
 A key component of the Carrier Comfort Network  Automatic chiller start/stop
(CCN) Chillervisor System.  Two seasonal chiller start/stop sequencing modes with
 Provides sophisticated multiple chiller control functions add/drop capability
to optimise the efficiency of the Carrier chiller plant.  Designated standby chiller support
 Coordinates the operation of a chilled water system in  Occupancy-based plant operation with configuration
which up to eight chillers feed a common chilled water override
loop.  Soft loading
 Consists of a module equipped with input and output Load balancing
points and specialised control and communication  Bypass valve control
software.  Chilled water set-point reset
 The CSM III operator interface is ComfortWORKS,  Loadshed demand limiting
Building Supervisor III or a Network Service Tool. With  Chiller fault handling and capacity matching
this an operator can:  System alarm messages and alarm history
 display a list of CSM III points that show the  Short- and long-term power failure recovery
status of the chiller system
 modify the value or status of selected points
and then return them to automatic control
 display and modify configuration and service
data
 display maintenance data
 display chiller system graphics
(ComfortWORKS or Building Supervisor)
 Additional capabilities possible by combining the CSM
III with the following CCN products:
 Autodial Gateway Touch screen interface
 Remote CCN Service Interface (RCSI)
 Data Collection Option
 Comfort Controller
 Water System Manager (WSM)
 Loadshed Option
 Alarm Printer Interface Module (APIM)

Company Restricted Information


Aquasmart Hydronic Systems
Evolution
FEATURES DESCRIPTION
 The Aquasmart Evolution system ensures  Aquasmart Evolution is a complete hydronic heating, ventilating and air conditioning
significant energy savings combined with (HVAC) system ideal for residential and light commercial applications from offices,
optimised user comfort by managing building commerce to hotels and hospitals. It offers perfect comfort for building occupants
zoning, occupancy and room temperatures in whilst optimising economical operation for applications up to 2500 m2. Larger
accordance with needs. installations with multiple systems can be managed and integrated within a single
 Terminal fan coil units can be organised in up Building Management solution thanks to the new BACnet option capability (available
to 32 zones to optimise building management as option in 2012).
by zone requirement and according to building  An Aquasmart system consists of up to 128 terminal fan coil units, served by up to
design conditions. two chillers or heat pumps (master-slave), to supply cooling and/ or heating to
 The Touch Pilot System Manager – the brain occupied spaces and fresh air handling units. The system manager can fully integrate
and building user interface – was designed to and control up to eight Carrier fresh air handling units* (39SQ). Each fresh air plant
facilitate use and allow rapid access to can be associated with specific terminal fan coils and/or zones for optimum building
manage and configure system operation to use management with occupancy, controlling and minimising energy use.
maximise energy savings at comfort  Individual schedules can be set up and managed for each and all air treatment
conditions. plants. The Aquasmart System Manager supplies building information enabling
 System components are fitted with dynamic and precise control of the 39SQ’s nigh ttime free-cooling feature to further
communicating controls allowing the System reduce building energy consumption.
Manager to ommunicate with and obtain
feedback on user needs and Operation. Based ENERGY SAVING
on the system requirements the System
Manager coordinates the system heating and The Aquasmart system
cooling modes for maximum comfort and controls offer superior
optimal energy consumption, respecting the comfort levels. By
comfort parameters and occupancy schedules optimising and controlling
for the building zones. the system components
 The Aquasmart system offers affordable building owners and
building HVAC system management featuring occupants can save
capabilities usually only available in more energy and reduce their
expensive solutions and requiring additional energy bill, contributing
building-by-building programming to a reduction in building
development. carbon emissions.

Literature
Company Restricted Information
Electronic Fan Coil Controllers
thermostats
FEATURES Operator Interfaces
 Fan operation - With the fan speed selector, fan mode can be set either The Carrier electronic thermostats are designed to
manually or automatically. In the manual mode it is possible to select three fan control and optimise the operation of hydronic
speeds (low/medium/high) according to personal preference. In the auto mode fan terminal fan coil
speed is regulated by a microprocessor in the control, based to the temperature units. They exist in two versions that match all
chosen. terminal fan coil configurations:
 Temperature selector - This is designed to maintain the temperature at the
desired level. The reference value at the centre of the range is 20°C. By turning
the knob towards the symbol (-) the temperature is reduced from the original
setting (minimum value is 10°C). By turning the knob towards the symbol (+), the
temperature is raised from the original setting (maximum value is 30°C).
 Energy saving mode - This function is especially useful when air conditioning at
night or in rooms where the user is likely to be absent for a longer period of time.
In this case, pushing the button raises the temperature during cooling by 4°C and
lowers it during heating by 4°C.
 Seasonal changeover
 Manual - Selection of heating/cooling is done manually by pushing the A B
button on the control.
 Centralised (only for type A control) - Centralised seasonal changeover
is possible in two ways:
 by a switch located on the central control panel that allows
heating/cooling mode changeover (to be provided by the installer).
 by a temperature sensor located in contact with the entering water pipe
- Automatic, based on air temperature (only for type B control) – The
automatic seasonal changeover allows automatic switching of the fan coil
operating mode to cooling or heating, depending on the temperature set
by the user and on the room temperature.
 External contact - The control has a 230 V input that can be used as window
contact or presence detector. When such a signal is activated (presence of line
voltage on the terminal block contact) the control is set to OFF mode. As a
consequence, all outputs (fan, valves etc.) are disconnected, and only frost
protection is active, if switched ON by the appropriate dip-switch.
 Frost-protection - This function keeps the temperature from dropping below 7°C
in rooms not used for long periods of time. Company Restricted Information
HDB Fan Coil Controllers
Controllers

FEATURES USER INTERFACES


Depending on the application, two user
 The HDB controller is a microprocessor-based
interface types can be selected:
controller designed to control and optimise the
 a wired user interface that can be mounted on
operation of hydronic terminal fan coil units.
the wall or inside compatible terminal fan coils
 Factory-installed on the terminal fan coil - The
(42N)
controller is factory-installed on the terminal fan coil;
 an infrared user interface to be used together
the assembly is also tested at the factory. As a result,
with a wall-mounted infrared received or a
field installation is extremely simple.
receiver incorporated in compatible terminal
 Ease of grouping - As an option, the HDB control can
fan coils (42GW)
be equipped with a grouping board that is used to
connect up to 15 units with a bus. All units connected
together will operate under the same conditions.
 Louvre control - For terminal fan coils equipped with
motorised louvres, the HDB controls the louvre position
as defined by the user or in swing mode.
 External contact - The control has an input that can
be used to remotely set the unit to economy mode.
 Scheduling - If the unit is used with an infrared user
interface, unit operation time can be scheduled on a
daily basis. Three start times and three stop times can
be programmed.
 Timer - If the unit is used with an infrared user
interface it can operate for a predefined duration before
switching to eco mode or off.

Company Restricted Information


NTC Fan Coil Controllers
Controllers

FEATURES ADVANCED FUNCTIONS NETWORK


COMMUNICATION
The NTC controller controls and optimises the  Low Energy Consumption (LEC)
operation of hydronic terminal fan coil units. It is a variable speed control. • The NTC communicating controller
microprocessor-based CCN (Carrier Comfort Network)  The NTC controller can drive the can be connected on an RS 485 bus,
compatible communicating controller with energy- fan speed continuously within a using the Carrier Comfort Network
configurable range for optimal (CCN) protocol.
saving algorithms . thermal and acoustic comfort. • Units equipped with the NTC
 Energy-saving algorithms manage water valve  Hydronic control - The NTC controls controller can be part of the
operation and fan speed control simultaneously to both floating and fixedpoint value Aquasmart Evolution system.)
ensure minimum energy consumption whilst actuator types (230 V on-off and 230
maximising comfort conditions for the occupant. V three point).
 Factory-installed on terminal fan coils  Demand controller ventilation (DCV)
The NTC controller is factory-installed on the terminal - On fan coils equipped with CO2
fan coil; the assembly is also factory-tested. As a sensors and fresh air dampers, the
result, field installation is extremely simple. NTC controller can adjust the amount
 A wide range of user interfaces of fresh air admitted to the room, as
 Depending on the application, two user interface required by the occupants.
types can be selected:  IAQ management - The NTC
- a simplified wired analogue user interface controller can control all features
(SUI) that can be wall-mounted related to Indoor Air Quality that are
- a wired communicating user interface included in Carrier terminal fan coil
(CRC2) that can be wall-mounted or units.
incorporated in compatible terminal fan coils
(42N)
- an infrared user interface (IR2) for use
together with a wall-mounted infrared received
or a receiver incorporated on compatible
terminal fan coils (42GW)
- a multi-function user interface (ZUI) that can
control comfort, lights and blinds within a
Carrier system

Company Restricted Information


Over-View Fan Coil Controllers

Company Restricted Information


Carrier Comfort Building Management System
Network (CCN)
FEATURES PRODUCT INTEGRATE CONTROLLER
The most advanced technology resulting from Carrier’s  Factory-installed product with a level of Monitoring and diagnostic
thorough knowledge of both comfort and controls. It Offers the control that can only be achieved with a factory-integrated device.
owner, designer and installer:  Product-Integrated Controllers are available on chillers, rooftops, air
 integrated product and control systems handling units and terminal fan coil units.
 single-point responsibility
 unique control strategies SYSTEM MANAGERS
 overall lower installation costs
 enhanced monitoring capabilities Carrier offers a complete line of network system products that tie
 Whilst each equipment component can operate in a stand- multiple stand-alone products together for a fully integrated, self-
alone mode, all components form a fully-integrated and adjusting HVAC system:
balanced HVAC system when networked with other Carrier Example: Chillervisor System Manager (CSM III) for chiller plant
equipment through the Carrier Comfort Network. A three-wire control
cable is all that is required to connect these products.

COMFORT VIEW
 Powerful supervision software package that allows centralised
monitoring (local and remote), data collection, report generation
and system configuration.
 Designed to run on most PCs running on Windows 2000 or
Windows XP.
 Designed for larger scale building management needs with
custom graphical Representation.

COMFORT CONTROLLER
 Field-installed device which allows non-Carrier equipment such
as boilers, cooling towers and pumps to be controlled and
integrated into the overall network.
 Fully programmable to suit the application need and optimized
control strategies..

Company Restricted Information


Comfort View Building Management System

FEATURES With ComfortVIEW you can get the


The primary human interface to the Carrier Comfort information you need fast. Link
Network (CCN). WorkSPACE screens in a logical
 Designed to run on any PC utilising the Microsoft“ ComfortVIEW lets you see your progression customised for your building
building’s equipment operation and and management needs.
Windows 2000 Professional or Server operating system, or
easily access time and set-point
the Windows XP Professional operating system.
schedules
 True system multitasking.
– without leaving your office.
 Local Area Network - allows multiple workstations to
share a common system database.
 Remote Communications - allows access to remote
ComfortVIEW databases.
 Graphical User Interface (GUI) - provides a consistent
With real time trend scanning, you
look and intuitive operation.
can visually determine how a
 Customised Access Levels.
system is behaving. ComfortVIEW
 Export data into other application software. allows you to easily view and record
 Dynamic Data Exchange (DDE). this data.
 Time and set-point schedule DLL allows third parties
access to CCN time and set-point schedules.
 CCN to Ethernet support provides for flexible location of
the ComfortVIEW computer.
 Organise and view data in a convenient format and to
Reduce troubleshooting time with
create your own custom data displays. ComfortVIEW’s onscreen
 Alarm processing is the automatic and full-time interaction. Change temperature set-
responsibility of ComfortVIEW. Receives, announces, and points, or force conditions – then
stores prioritised alarms. view the results and determine
 The Carrier Network Manager allows you to display, action, prior to dispatching a
modify, and delete the areas, controllers, and data tables in mechanic.
your ComfortVIEW database.
 The Reports function is used to generate reports from
network and database data. ViewSPACES can use graphics
 ComfortVIEW report data also allows you to create your This power plant ViewSPACE or photos of your actual
shows various equipment equipment, for easier analysis
own custom reports . operating parameters at a glance. of operating conditions.
Company Restricted Information
50UA Series Packaged RoofTop cooling units

7 sizes – 44 to 115 kW (cooling)

MAIN FEATURES COMMUNICATION CAPABILITIES


 R410A Refrigerant  CCN/JBus, Lon or BACnet gateways
 Cu/Alu coils
 Axial “Flying Bird” fans
 Cabinet made of powder-painted sheet metal. MAIN OPTIONS* / ACCESSOIRES**
 Compressors are hermetic scroll compressors
and mounted on vibration isolators.  Electric heaters, various capacities*
 Crankcase heaters are standard for all units.  Hot-water coils, various capacities*
 Various coil protection options*
EFFICIENCY  Fresh-air sliding panel*
 Manual outdoor air damper*
 EER Cooling 2,9  Economizer, thermostatic or enthalpy control,
 Eurovent certified with or without CO2 sensor control*
 Supply fan with various high static pressure
SOUND options with or without soft starter*
 Standard supply fan *
 Sound Power 86 – 91 dB(A)  Various filter options*
 Stainless steel drain pan*
 Energy recovery module*.......................
DIMENSIONS  Various return/exhaust air options*
 Various temperature sensor options*
 Length (mm): 2125 - 3581  Dirty filter detection*
 Width (mm): 2193  Supply air flow detection*
 Height (mm): 1413 -1825  Smoke detector* / Fire thermostat*
 Duct connection fixing frame*
 Roof curb**
Literature  Transition roof curb (French ERP)**
 Remote user interface (Pro-Dialog+)**

Company Restricted Information


50UH Series Packaged RoofTop Reversible Heat Pumps

7 sizes – 44 to 115 kW (cooling)


44 to 121 kW (heating)

MAIN FEATURES COMMUNICATION CAPABILITIES


 R410A Refrigerant  CCN/JBus, Lon or BACnet gateways
 Cu/Alu coils
 Axial “Flying Bird” fans
 Cabinet made of powder-painted sheet metal. MAIN OPTIONS* / ACCESSOIRES**
 Compressors are hermetic scroll compressors
and mounted on vibration isolators.  Electric heaters, various capacities*
 Crankcase heaters are standard for all units.  Hot-water coils, various capacities*
 Various coil protection options*
EFFICIENCY  Fresh-air sliding panel*
 Manual outdoor air damper*
 COP 3,2  Economizer, thermostatic or enthalpy control,
 Eurovent certified with or without CO2 sensor control*
 Supply fan with various high static pressure
SOUND options with or without soft starter*
 Standard supply fan *
 Sound Power 86 – 91 dB(A)  Various filter options*
 Stainless steel drain pan*
 Energy recovery module*........................
DIMENSIONS  Various return/exhaust air options*
 Various temperature sensor options*
 Length (mm): 2125 - 3581  Dirty filter detection*
 Width (mm): 2193  Supply air flow detection*
 Height (mm): 1413 -1825  Smoke detector* / Fire thermostat*
 Duct connection fixing frame*
 Roof curb**
Literature  Transition roof curb (French ERP)**
 Remote user interface (Pro-Dialog+)**

Company Restricted Information


48UA Series Packaged RoofTop Cooling + GAS HEATING

7 sizes – 44 to 115 kW (cooling)


42 to 151 kW (heating)
MAIN FEATURES COMMUNICATION CAPABILITIES

 48UA units are packaged rooftop cooling units,  CCN/JBus, Lon or BACnet gateways
factory fitted with a multistage gas heater.
 R410A Refrigerant
 Cu/Alu coils
MAIN OPTIONS* / ACCESSOIRES**
 Axial “Flying Bird” fans
Natrural gas or propane gas modules
 Cabinet made of powder-painted sheet metal.
various capacities*
 Compressors are hermetic scroll compressors
 Various coil protection options*
and mounted on vibration isolators.
 Fresh-air sliding panel*
 Crankcase heaters are standard for all units.
 Manual outdoor air damper*
 Gas heating system designed as an alternative
 Economizer, thermostatic or enthalpy control,
to the hot water coil or electric heating options.
with or without CO2 sensor control*
Units are available with three gas heating
 Supply fan with various high static pressure
modules.
options with or without soft starter*
Tubular dimpled gas heat exchanger optimises
 Standard supply fan *
heat transfer for maximum efficiency.
 Various filter options*
 Modular burner assembly consists of a series of
 Stainless steel drain pan*
injectors.
 Energy recovery module*........................
 Induced draft combustion system for improved
 Various return/exhaust air options*
efficiency.
 Various temperature sensor options*
 Integrated gas unit controller (IGC).
 Dirty filter detection*
 Supply air flow detection*
DIMENSIONS  Smoke detector* / Fire thermostat*
 Duct connection fixing frame*
 Length (mm): 2125 - 3581
 Roof curb**
 Width (mm): 2193
 Transition roof curb (French ERP)**
 Height (mm): 1413 -1825
 Remote user interface (Pro-Dialog+)**

Literature
Company Restricted Information
48UH Series Packaged RoofTop Heat Pump + GAS HEATING

7 sizes – 44 to 115 kW (cooling)


42 to 151 kW (heating)
MAIN FEATURES COMMUNICATION CAPABILITIES

 48UA units are packaged rooftop cooling units,  CCN/JBus, Lon or BACnet gateways
factory fitted with a multistage gas heater.
 R410A Refrigerant
 Cu/Alu coils
MAIN OPTIONS* / ACCESSOIRES**
 Axial “Flying Bird” fans
Natrural gas or propane gas modules
 Cabinet made of powder-painted sheet metal.
various capacities*
 Compressors are hermetic scroll compressors
 Various coil protection options*
and mounted on vibration isolators.
 Fresh-air sliding panel*
 Crankcase heaters are standard for all units.
 Manual outdoor air damper*
 Gas heating system designed as an alternative
 Economizer, thermostatic or enthalpy control,
to the hot water coil or electric heating options.
with or without CO2 sensor control*
Units are available with three gas heating
 Supply fan with various high static pressure
modules.
options with or without soft starter*
Tubular dimpled gas heat exchanger optimises
 Standard supply fan *
heat transfer for maximum efficiency.
 Various filter options*
 Modular burner assembly consists of a series of
 Stainless steel drain pan*
injectors.
 Energy recovery module*........................
 Induced draft combustion system for improved
 Various return/exhaust air options*
efficiency.
 Various temperature sensor options*
 Integrated gas unit controller (IGC).
 Dirty filter detection*
 Supply air flow detection*
DIMENSIONS  Smoke detector* / Fire thermostat*
 Duct connection fixing frame*
 Length (mm): 2125 - 3581
 Roof curb**
 Width (mm): 2193
 Transition roof curb (French ERP)**
 Height (mm): 1413 -1825
 Remote user interface (Pro-Dialog+)**

Literature
Company Restricted Information
Energy Recovery Module (option)
For Packaged Roof Top units

FEATURES
 The ERM is dual-flow individual unit equipped with a high-efficiency air-to-air Eurovent certified heat recovery wheel (efficiency
63% to 88%), with integrated variable air volume plug fan and a control system for a plug & play installation.

The modules are especially designed to ensure economical extraction of indoor air and taking in fresh air to meet current and
future requirements for high energy efficiency buildings

Rotary condensation heat exchanger wheel :


it reclaims up to 90% of the heat from the extract
air and transfers it to the supply air, considerably
reducing the thermal load on the heating and air
conditioning equipment.
Its performances are Eurovent Certified.

Variable exhaust air volume (no building


pressurization) The exhaust air plug fan speed is
independently controlled by frequency inverters
directly connected to ProDialog+ controller inside
rooftop unit.

Easy installation: power & control cable


connected to RTU, field mounted extract/supply
ducts
Literature

Company Restricted Information


16 TJ series Steam-Fired Absorption Chiller
352 to 2461 kW (15 units ) SUPER ABSORPTION
FEATURES
 Fifteen sizes with nominal cooling capacities from 352 to 2461 kW.
 Designed for cooling applications where low-pressure steam is
available as waste heat.
 Can tie into district steam systems.
 Allows diversification of critical cooling requirements. Critical
cooling loads are met with minimal electrical power input with steam-
fired chillers.
 Allows use of smaller emergency generators since the electrical
load associated with an absorption chiller is minimal, compared to
an electrically driven chiller.
 Ozone-friendly and CFC-free. Cooling requirements are met
without chlorine based refrigerants.
 Minimises global warming effect by greatly reducing power
consumption and eliminating the generation of greenhouse gases.
 Reduced noise and vibration levels. The absorption chiller does
not use a large motor-compressor, leading to quiet, trouble-free
operation.
 Small footprint. The high efficiency associated with these chillers
results in a reduction of the required installation space.
 Auto-diagnosis system monitors operating conditions, predicts
chiller information and maintains stable operation.
 Advanced high-precision control system.
 Absorption pump with inverter control (option) for energy-saving
operation.
 High-performance purge system maintains unit performance and
minimises maintenance requirements.
 State-of-the-art protection devices guarantee enhanced operating
Literature safety.

Single Effect Company Restricted Information


16 LJ series Hot Water-fired Absorption Chiller
264 to 1846 kW (15 units ) SUPER ABSORPTION
FEATURES
• Fifteen sizes with nominal cooling capacities from 264 to 1846 kW.
• Designed to provide chilled water from waste heat sources,
generated from industrial processes and cogeneration systems.
• Allows diversification of critical cooling requirements. Critical
cooling loads are met with minimal electrical power input with hot
water-fired chillers.
• Allows use of smaller emergency generators since the electrical
load associated with an absorption chiller is minimal, compared to
an electrically driven chiller.
• Ozone-friendly and CFC-free. Cooling requirements are met
without chlorine based refrigerants.
• Minimises global warming effect by greatly reducing power
consumption and eliminating the generation of greenhouse gases.
• Reduced noise and vibration levels. The absorption chiller does not
use a large motor-compressor, leading to quiet, trouble-free
operation.
• Small footprint. The high efficiency associated with these chillers
results in a reduction of the required installation space.
• Auto-diagnosis system monitors operating conditions, predicts
chiller information and maintains stable operation.
• Advanced high-precision control system.
• Absorption pump with inverter control (option) for energy-saving
operation.
• High-performance purge system maintains unit performance and
minimises maintenance requirements.
• State-of-the-art protection devices guarantee enhanced operating
safety.
Literature

Single Effect
Company Restricted Information
16 DJ series Direct-Fired Absorption Chiller/Heaters
352 to 5274 kW (23 units ) SUPER ABSORPTION
FEATURES
• Twenty-three sizes with nominal cooling capacities from 352 to
5274 kW and heating capacities from 268 to 4026 kW.
• The 16DJ absorption chillers/heaters offer building owners a better
solution for many new and retrofit applications. Installation of a
direct-fired chiller/heater eliminates the need for a boiler, reducing
the initial cost of the system.
• Excellent for peak shaving during high electrical demand periods.
• Allows diversification of critical cooling requirements. Critical loads
are met with minimal electrical power input.
• Allows use of smaller emergency generators since the electrical
load associated with an absorption chiller is minimal.
• Ozone-friendly and CFC-free.
• Minimises global warming effect by greatly reducing power
consumption.
• Reduced noise and vibration levels. The absorption chiller does not
use a large motor-compressor, leading to quiet, vibration-free
operation.
• Small footprint. The high efficiency associated with double-effect
chillers results in reducing the required installation space.
• Auto-diagnosis system monitors operating conditions, predicts
chiller information and maintains stable operation.
• Advanced high-precision control system.
• Absorption pump with inverter control for efficient, energy-saving
operation.
• High-performance purge system minimises maintenance
requirements.
• State-of-the-art protection devices guarantee enhanced operating
Literature safety.

Double Effect
Company Restricted Information
16 NK series Steam-Fired Absorption Chiller
345 to 4652 kW (18 units ) SUPER ABSORPTION
FEATURES
Eighteen sizes with nominal cooling capacities from 345 to 4652 kW.
• The 16NK absorption chillers are designed for cooling applications
where low-pressure steam is available as waste heat.
• Can tie into district steam systems.
• Allows diversification of critical cooling requirements. Critical
cooling loads are met with minimal electrical power input.
• Allows use of smaller emergency generators since the electrical
load associated with an absorption chiller is minimal.
• Ozone-friendly and CFC-free.
• Minimises global warming effect by greatly reducing power
consumption and eliminating the generation of greenhouse gases.
• Reduced noise and vibration levels. The absorption chiller does not
use a large motor-compressor, leading to quiet, vibration-free
operation.
• Small footprint. The high efficiency associated with double-effect
chillers results in a reduction of the required installation space.
• Auto-diagnosis system monitors operating conditions, predicts
chiller information and maintains stable operation.
• Advanced high-precision control system.
• Absorption pump with inverter control for efficient, energy-saving
operation.
• High-performance purge system minimises maintenance
requirements.
• State-of-the-art protection devices guarantee enhanced operating
safety.

Literature
Double Effect
Company Restricted Information
80HMA Comfort Module range for Monobloc Heat Pumps

5 sizes – 4 to 20 kW
Single zone module
BENEFITS
Peace of mind
MAIN FEATURES - Complete system from one single manufacturer
Single zone comfort module: - Fully programmable thermostat & child lock
Control back up and booster heater (built in EH or - Simple and Limited control settings
Boiler) - 2 zones systems made easy
Control up to 8x30AWH inverter heat pump with bus - Product made in Europe with Nationwide service
communication Savings
Third party remote control connections with dry - System using energy efficient inverter HP
contacts - High system integration for proper HP control  8 liters expansion vessel
Compatible with solar thermal DHW - DHW available all year round, connectable to solar  Manometer

Control diverting valve for DHW - Limited installation time  Pressure switch
- Widely available spares  10 liters buffer tank
Reversible or heating only
 Electrical heater
Single or three phase booster EH Comfort
 Moving elec panel
10 liter buffer tank - Constant monitoring of outdoor weather conditions
 User interface
Expansion vessel - Fully programmable thermostat & child lock  LWT Temperature sensor
2 zones kit: - Product made in Europe with Nationwide service  Boiler water connections

Modulating 3 way valve  Safety valve

Hydraulic decoupling ACCESSORIES


Circulating pumps Dual zone kit
• Communication kit for installation on the heat pump
• Additional user interface
• Remote outdoor sensor to maximises comfort
• Domestic hot water tank
Interface • Domestic hot-water three-way valve
• Thermal cut-out, floor heating protection
• Piping kit to install domestic hot water valve and
actuator inside the unit.
• Cover panel for detached two-zone kit
Literature • Kit to add three-way valve+actuator in second zone
• Two-zone kit allows independent control of two
comfort zones
• Swimming pool kit controls
Company Restricted Information
PRO-DIALOG Chilled-Water Plan Control System
PRO-DIALOG PLUS operator interface
MAIN FUNCTIONS
CONTROL FEATURES • On/Off control
Pro-Dialog Plus combines Local control selection
Intelligence with operating Remote on/off contact
simplicity. The control constantly Time schedule
Outside Air Temperature override Immediate display of :
monitors all machine parameters  Temperatures
and precisely manages the • Operation feedback
Ready to start or running indicator  Pressures
operation of compressors,  Operating hours
expansion devices, fans and of The • Two cooling setpoints
 Control point
evaporator water pump for optimum Manual selection
energy efficiency. Remote contact
■ Ease-of-use Time schedule
User interface with synoptic • Setpoint reset
diagram for intuitive display of the Outside air temperature
principal operating parameters: Water delta t
number of compressors operating, • Heat Reclaim/Cool Mode selection
suction/discharge pressure, Manual selection
compressor operating hours, set Remote contact
point, air temperature, • One remote contact with single Demand limit It gives access to all PRO-DIALOG PLUS data and
entering/leaving water temperature setpoint operating functions.
Ten menus for direct access to all • Demand limit setpoint for Night period It consists of:
machine commands, including fault • Separate outputs for alarm or alert reporting • A two-digit display showing the number of
• Maintenance alerts for pumps, filter and loss of the item selected.
charge servicing • A four-digit display showing the contents of
• New black box function the item selected.
A/C • Master Slave based on common leaving • LEDs and buttons for unit start/stop, menu
selection, menu item selection and value
temperature
adjustment.
• Compressor protected against short cycling by
Auto-adaptive control (Carrier patent)
W/C
Company Restricted Information
PRO-DIALOG Chilled-Water Plan Control System

PRO-DIALOG + …HMI operator interface


Contrast -OFF = Unit OFF -OFF = No alarm
control wheel -ON = Unit ON or stopping -ON = Alarm & Unit shutdown
-FLASHING = Unit starting -FLASHING = Alert

- Exit to default screen


- Go to parent menu
- Exit table
- Exit modification - Scroll default screens
MAIN FUNCTIONS ( * For water cooled units) - Cancel changes
- Back to previous
- Scroll operating modes
- Scroll menus
screen - Scroll items
• Local control - Scroll digits
- Switch Boolean values
• Remote control
•3 configuration level with 3 independent passwords
• Water exchanger control: entering or leaving
• Low and high pressure monitoring -Valid unit stop command
• Circuit low saturated suction temperature protection -Valid operating mode
-Go to main menu from
• Circuit high discharge pressure protection default screen
• Manual heat/cool select -Go to selected menu
-Go to next menu page (…)
• Off/on delay at startup -Go to selected table
• Unit on/off schedule control -Force/Modify selected item
-Save changes
• CCN network compatibility -Stop unit -Valid selection
• CSM control -List of available operating modes -Valid digit
2x = Valid entered value
• Aquasmart System Manager compatibility
• Dual cooling/heating setpoint time schedule controlled
• Dual cooling/heating setpoints through remote contact CONTROL FEATURES
• Cooling reset based on water exchanger delta T
• Heating reset based on water exchanger delta T * • Modern displays
• Single Demand limit controlled through remote contact • Energy features
• Demand limiting through CCN control • Multiple languages
• Demand limiting based on current control • Service & Commissioning
• Cooler pump #1 & # 2 control sequence • Efficiency & Comfort
• Condenser pump #1 & # 2 control sequence * • Easy Plant Room integration
• Water pump periodical quick start sequence • Remote monitoring
• Master Slave based on common leaving temperature • Black box

Company Restricted Information


PRO-DIALOG Chilled-Water Plan Control System
PRO-DIALOG Touch screen interface
MAIN FUNCTIONS
• On/Off control
Local control selection
Remote on/off contact
Time schedule
CONTROL FEATURES Outside Air Temperature override
• Operation feedback
• Modern displays Ready to start or running indicator
• Energy features • Two cooling setpoints
• Multiple languages Manual selection
• Service & Commissioning Remote contact
• Efficiency & Comfort Time schedule
• Easy Plant Room integration • Setpoint reset
• Remote monitoring Outside air temperature
• Black box Water delta t
• Flash downloadable memory • Heat Reclaim/Cool Mode selection
Manual selection
Remote contact
• One remote contact with single Demand limit setpoint
• Demand limit setpoint for Night period
• Separate outputs for alarm or alert reporting
• Maintenance alerts for pumps, filter and loss of charge
servicing
• New black box function
• Master Slave based on common leaving temperature

Company Restricted Information


PRO-DIALOG Chilled-Water Plan Control System
TOUCH PILOT operator interface
MAIN FUNCTIONS ( * For water cooled units)
• Local control
• Remote control
• CCN control
CONTROL FEATURES • 3 configuration level with 3 independent passwords
• Modern displays • Water valve control *
• Energy features • Cooler fluid type: water, medium brine or low brine
• BAS intergration Web servers • Condenser fluid type: water or brine *
• Open protocol (Bacnet Ip) • Dry cooler *
• Service & Commissioning • Water exchanger control: entering or leaving
• Efficiency & Comfort • Low and high pressure monitoring
• Easy Plant Room integration • Circuit low saturated suction temperature
• Remote monitoring protection
• Multiple languages (unicode) • Circuit high discharge pressure protection
• Spare parts list access • Manual heat/cool select
• Black box, e-mail, • Off/on delay at startup
• Manuals • Unit on/off schedule control
• Trending • CCN network compatibility
• CSM control
• Aquasmart System Manager compatibility
• Dual cooling/heating setpoint time schedule controlled
• Dual cooling/heating setpoints through remote contact
• Cooling reset based on water exchanger delta T
• Heating reset based on water exchanger delta T *
• Single Demand limit controlled through remote contact
• Demand limiting through CCN control
• Demand limiting based on current control
• Cooler pump #1 & # 2 control sequence
• Condenser pump #1 & # 2 control sequence *
• Water pump periodical quick start sequence
• Master Slave based on common leaving temperature
Company Restricted Information
PIC Control Chilled-Water Plan Control System
ICVC operator interface
MAIN FUNCTIONS
• Chilled-water reset
• Demand limiting
• Ramp loading
• Automated controls test
• 365-day real time clock
• Occupancy schedules
• Extensive service menu
• Battery backup
CONTROL • Other control features include:
Display of over 125 operating, status and diagnostic messages for improved user
FEATURES interface.
The ICVC (Interface Chiller • Microprocessor-controlled oil heater
Visual Control), that can be • Safeties
configured to display units in Unit is automatically shut down when any of the following conditions occur:
Imperial or metric, provides -- Motor overcurrent
-- Over voltage*
unparalleled ease of
-- Under voltage*
operation. A 16-line by 40-
-- Single cycle dropout*
character
-- Bearing oil high temperature
LCD (Liquid Crystal Display) -- Low evaporator refrigerant temperature
features four menu-specific -- High condenser pressure
soft keys. Default display -- High motor temperature
offers easy, quick display of -- High compressor discharge temperature
key chiller operation data, -- Low oil pressure
simplifying the interaction -- Prolonged surge
between machine and user. -- Loss of cooler water flow
Local languages are available -- Loss of condenser
upon request • Alarm file
This file maintains the last 25 time- and date-stamped alarm and alter messages
in memory; this function reduces troubleshooting time and cost.
• Overrides
The control system detects conditions which approach protective limits and takes
self-corrective action prior to an alarm occurring.
Company Restricted Information
PRO-DIALOG Control System for 39SQC /R/P Air Handling Units
PRO-DIALOG + …HMI operator interface (option)
MAIN FEATURES
KEY CONTROL FUNCTIONS
• Built in time clock
• Temperature control (Supply or extract or room
temperature, Outdoor temperature compensation)
• Summer night free cooling control
With Pro-Dialog everything is possible! • Air volume control -Constant volume or constant pressure
or variable air volume (C02 sensor)
Pro-Dialog AHU control combines superior intelligence with
• Safeties & alarms - Service & alarm signals, Alarm history
simplicity of use.
FRIENDLY OPERATOR INTERFACES
It controls the operation of all components and optimises power
• Integrated WEB server - Access from any computer, No
consumption. Temperature control, based on return, supply or room air,
specific software required
adjusted for outside temperature, history of possible incidents, immediate
• Pro-Dialog+ interface (option) - Local or remote
air flow measurement etc. installation up to 300 m, One interface for multiple units
• Web server & Pro-Dialog key features - Four access
The integrated web server gives access to the operating parameters levels protected by password, Multiple languages
from any standard internet browser. This user-friendly approach permits REMOTE CONTROL
simple equipment control - the user is guided at every step. • Customer contacts
The information is displayed in the language chosen by the user. •Alert signal (service )
The Pro-Dialog+ user interface, available as an option can be installed up •Alarm signal
to 300 metres from the unit, and a single interface allows remote control of •Occupancy control (external clock)
several air handling units. •Occupancy overide
•BMS fire signal
•High/low fan speed control
• RS485 port
•CCN: Aquasmart System Manager
•JBus gateway (option)
•BACnet gateway (option)
EXTERNAL CONTROLS
• Hot & chilled water valves control (0-10V signal)
• Hot & chilled water pumps control (on/off)
• Cooling/heating production control (on/off)
Company Restricted Information
OFFICE
INDUSTRY
HOTEL
COMMERCIAL CENTRE

Water-source
Heat Pump

You might also like