ICO4-PST

Electromagnetic actuated, directly controlled

>> 3/2 Smart solenoid >> Up to 5 Cv removes


poppet valves; need for additional
1/4 NPT ... 3/4 NPT, QEV’s and Pilot valves
G1/4 ... G3/4 >> Offers SIL 3
>> Partial Stroke Testing performance as 1oo1
integrated into the >> Always gives maximum
ICO4 valve possible Diagnostic
>> Dramatically reduces Coverage, thus
engineering facilitating maximum
requirements possible proof test
intervals

Technical features
Medium: Operating pressure: Mounting position: Materials:
Pneumatic – customer to specify 0 ... 10 bar (0 ... 145 psi) Solenoid vertical Valve body, trim, coil housing
and confirm compatibility Flow: Ambient/media temperature: and top cover:
Operation: 0,8 Cv (11,5 Kv) ... 5 Cv (72 Kv) 1/4 ... 1/2 NPT resp. G1/4 ... 1/2 stainless steel 1.4404 (316 L)
Direct solenoid operated Port size: -40 ... +60°C (-40 ... +140°F) O-rings seats & seals: NBR/FPM
poppet valves with integral 1/4 NPT, 1/2 NPT, 3/4 NPT, 3/4 NPT resp. G3/4
pressure transmitter G1/4, G1/2, G3/4 -40 ... +50°C (-40 ... +122°F) Other seal materials available on
Air supply must be dry enough request
to avoid ice formation at
temperatures below +2°C (+35°F).

Technical data - standard models


Symbol Port Cv Conduit Seal Weight Drawing Model
size connection Material (kg) (lbs) No.

1/4 NPT 0,8 1/2 NPT NBR 6,7 14,8 1 Y413AA1H2BS


G1/4 0,8 M20 x 1,5 NBR 6,7 14,8 1 Y413AE1H1BS
2
C
P
1/2 NPT 2,1 1/2 NPT NBR 6,9 15,2 2 Y413AA3H2BS
G1/2 2,1 M20 x 1,5 NBR 6,9 15,2 2 Y413AE3H1BS
1 3
3/4 NPT 5 1/2 NPT NBR 9,0 19,8 3 Y413AA5H2BS
2 G3/4 5 M20 x 1,5 NBR 9,0 19,8 3 Y413AE5H1BS
C
P

Other product and body material available for more information contact Maxseal technical service
1 3
Electrical details ATEX details
Voltage: 2 24 V d.c., 110/115 V d.c., 125V d.c., 120V a.c. Certification: Ex db IIC T4/T6
C
P

Rating: Model: ICO4E


1 3
Voltage tolerance ±12,5% of Nominal* Ambient temperature: T4:
Power consumption: Charging (~4 Mins) 1/4 ... 1/2 NPT resp. G1/4 ... 1/2
6,7 W (1/4”); 9,7 W (1/2”), 17,4 W (3/4”)* -40 ... +60°C (-40 ... +140°F)
Steady-State 3/4 NPT resp. G3/4
5,7 W (1/4”); 8,7 W (1/2”), 16,4 W (3/4”)* -40 ... +50°C (-40 ... +122°F)
Insulation class Class H T6:
-40 ... +43°C (-40 ... +110°F)
Conduit connection 1/2 NPT or M20 x 1,5
Additional Global In-Metro, TR CU, Class I Div 1 FM3600 /
IP-Protection class IP66
Approvals: FM3615 / CSA 22.2
EN 60529
*typical for 24VDC ICO4-PST, refer to specific product datasheet - contact sales.
[email protected] for further information

Our policy is one of continued research and development. We therefore reserve the right to amend, 2/18
without notice, the specifications given in this document. (2015 - 5330i) © 2015 Thompson Valves Ltd. en 5.7.580.01
ICO4-PST
Electromagnetic actuated, directly controlled

Option selector Y413˙˙˙˙˙˙S


Operation Substitute Voltage Substitute
Automatic A 24 V d.c. B
Push button, Manual reset P 125 V d.c. E
Remote manual reset J 110 V a.c. J
Port size Substitute 110/115 V d.c. R
1/4 NPT A1 120 V a.c. T
G1/4 E1 Conduit connection Substitute
1/2 NPT A3 M20 x 1,5 mm 1
G1/2 E3 1/2 NPT 2
3/4 NPT A5 M20x1,5 with local HART 3
Interface
G3/4 E5
1/2 NPT with local HART 4
Interface
Seat/seal material Substitute
NBR H
FPM V

Wiring diagram 24 V d.c. For 100-125V specific wiring diagrams see operating manual MI0588.

+V OUT
3-WIRE
SIG IN
Terminal Block POTENTIOMETER
ICO4-PST

-V OUT
Connections
(2,5 mm2 4-20mA/HART
INTERFACE
4-20mA/HART -
4-20mA/HART +
cable maximum)
CONTROL VOLTAGE
0V
24V

Our policy is one of continued research and development. We therefore reserve the right to amend, 
en 5.7.580.02 without notice, the specifications given in this document. (2015 - 5330i) © 2015 Thompson Valves Ltd. 2/18
ICO4-PST
Electromagnetic actuated, directly controlled

Dimensions Dimensions shown in mm


Projection/First angle
1 152
1 2 1
137
69 34

21

20
121

246
3
30

4
151

1
2
68

3
44
32

21

51 Ø 82 64
Ø 56
1

69 63 22
M8

1 Conduit connection
M20 x 1,5 or 1/2 NPT
2 Ex d Breather
3 External Earth
4 Pressure sensor port 1/4 NPT

Our policy is one of continued research and development. We therefore reserve the right to amend,
2/18 without notice, the specifications given in this document. (2015 - 5330i) © 2015 Thompson Valves Ltd. en 5.7.580.03
ICO4-PST
Electromagnetic actuated, directly controlled

Dimensions Dimensions shown in mm


Projection/First angle
2
152
1
137 1 34 2
69

21

20
121

3 3

273
30

4
19
178

3
Ø 6,5

95

66
1
42
18

1 29 64
44
64 Ø 82

69 63 22
M8

1 Conduit connection
M20 x 1,5 or 1/2 NPT
2 Ex d Breather
3 External Earth
4 Pressure sensor port 1/4 NPT

Our policy is one of continued research and development. We therefore reserve the right to amend, 
en 5.7.580.04 without notice, the specifications given in this document. (2015 - 5330i) © 2015 Thompson Valves Ltd. 2/18
ICO4-PST
Electromagnetic actuated, directly controlled

Dimensions Dimensions shown in mm


Projection/First angle
3
152
137 34
1 17 2

21

20
121

3
3
30

292
4
19
197

2
114
86

1
57
26

70
74
Ø 82 64
1

69 63 22
M8

1 Conduit connection
M20 x 1,5 or 1/2 NPT
2 Ex d Breather
3 External Earth
4 Pressure sensor port 1/4 NPT

Our policy is one of continued research and development. We therefore reserve the right to amend,
2/18 without notice, the specifications given in this document. (2015 - 5330i) © 2015 Thompson Valves Ltd. en 5.7.580.05
ICO4-PST
Electromagnetic actuated, directly controlled

ICO4-PST Push Button Manual Reset (PBMR) Dimensions shown in mm


Projection/First angle
Description:
The ICO4-PST PBMR is an electronic solution to providing push button manual reset functionality to the ICO4-PST.
It is an optional addition to the ICO4-PST – refer to option selector for part numbering details. The ICO4-PST PBMR requires
connection of correct supply voltage followed by actuation of the push button in order for the valve and electronics to
operate. Once the valve has been operated by actuation of the push button it will stay open until the supply voltage is removed, at
which point the valve will close in the same manner as the standard automatic ICO4-PST. The ICO4-PST PBMR can also be used
in Remote Manual Reset (RMR) mode. For further details on ICO4-PST PBMR and RMR versions refer to manual MI0588.

Certification: Ø97,0
ATEX/IECEx 34,0
Ex II G D 17,0
Ex db IIC T4/T6 Gb
Ex db IIIC T130°C Db

36,2
T4 Ta +60°C (¼”, ½”)
T4 Ta +50°C (¾”)
T6 Ta +43°C (All)
IP66
58,7 1
246

Ø 56

69 63
2

3
137

62 6 1 Pressure sensor port 1/4 NPT


5
2 2 x conduit entry on this face
3 1 x conduit entry on this face
4 2 x conduit entry on this face
5 Enclosure breather
6 Ex d push button for manual
reset function

Our policy is one of continued research and development. We therefore reserve the right to amend, 
en 5.7.580.06 without notice, the specifications given in this document. (2015 - 5330i) © 2015 Thompson Valves Ltd. 2/18
ICO4-PST
Electromagnetic actuated, directly controlled

Local HART Interface dimensions Dimensions shown in mm


Projection/First angle
Description:
The Local HART Interface is an optional extra for the ICO4-PST which provides an Intrinsically Safe connection to the HART
electrical interface on the ICO4-PST flameproof (Ex d) solenoid valve. This allows a local HART connection to be established
with the ICO4-PST with in a hazardous (explosive atmospheres) environment whilst maintaining the ATEX protection of the
ICO4-PST. See ICO4-PST Manual MI0588 for further details.

Certification: 34
ATEX
Ex II 2 G D
Ex db mb [ib] IIC T4 Gb
Ex mb tb [ib] IIIC T135°C Db
T4 Ta (-40°C to +60°C)
Ø 59
IP66

Additional Global Approvals:


Class I Div 2 1
CSA 22.2 No 60079
ANSI / ISA-60079
142

153

85

1 Local HART Interface


2 46

EN - Englisch
Warning
These products are intended for use in industrial compressed air systems Through misuse, age, or malfunction, components used in fluid power
only. Do not use these products where pressures and temperatures can systems can fail in various modes. The system designer is warned to
exceed those listed under »Technical features/data«. consider the failure modes of all component parts used in fluid power
Before using these products with fluids other than those specified, for systems and to provide adequate safeguards to prevent personal injury
non-industrial applications, life-support systems or other applications not or damage to equipment in the event of such failure.
within published specifications, consult System designers must provide a warning to end users in the system
IMI Precision Engineering, Thompson Valves Ltd. instructional manual if protection against a failure mode cannot be
adequately provided.
System designers and end users are cautioned to review specific warnings
found in instruction sheets packed and shipped with these products.
For further information please see Functional Safety Manual MI0560.