IPS-MEHTALIA PVT. LTD.
Consulting Engineers . Construction Management . Commissioning & Qualification
B101-109, 1st Floor, Kailash Vaibhav Industrial Estate, Vikhroli (W), Mumbai – 400 079
DOCUMENT NO. IPS-MBD21907-IN-510A
DATA SHEET
OF
FLOW TRANSMITTER - MASS TYPE
Project : Project Unnati
Location : Dahej, Gujarat
A 19-Jul-21 First Issue NPK SNS SSP
Rev Date Description Made Chkd by Apd by
Entire Specification ISSUED FOR
Issued this Revision In-house Review Purchase
Revised Pages Only Client Approval Construction
Issued this Revision Enquiry Engineering
This document has been prepared for the above project or named part thereof and should not be relied upon or used for any other project without prior written consent from IPS-
Mehtalia Pvt. Ltd. IPS-Mehtalia Pvt. Ltd. accepts no responsibility or liability for the consequence of this document being used for a purpose other than the purposes for which it was
commissioned. Any person using or relying on the document for such other purpose agrees, and will by such use or reliance be taken to confirm his agreement to indemnify IPS-
Mehtalia Pvt. Ltd. for all loss or damage resulting there from. IPS-Mehtalia Pvt. Ltd.accepts no responsibility or liability for this document to any party other than the person by whom
it was commissioned.
COVER PAGE
IPS-MEHTALIA PVT. LTD. Client NSCL
Consulting Engineers . Construction Management . Commissioning & Qualification Project No. MBD21907
B101-109, 1st Floor, Kailash Vaibhav Industrial Estate, Vikhroli (W), Mumbai – 400 079 Made/App. NPK/SSP
Document Title: Data sheet of Flow Transmitter - Mass Type REV. A
Document No.: IPS-MBD20031-IN-511A Date 19-Jul-2021
DATA SHEET OF FLOW TRANSMITTER - MASS TYPE
Units: Flow :- Liquid: Kg/h Gas: Nm3/h Steam:Kg/h; Pressure: Bar (g); Temperature:- °C; Level/length:- mm
1 Tag No. RFS
2 P & ID No. RFS
GENERAL 3 P & ID Rev No. RFS
4 Service RFS
5 Area Classification RFS
6 Line Number RFS
LINE 7 Line Size RFS
8 Line Material RFS
9 Fluid/Service RFS
10 Fluid State RFS
11 Flow - Min. / Norm. / Max (Unit) RFS
12 Pressure - Min. / Norm. / Max (Unit) RFS
PROCESS DATA
13 Temperature - Min. / Norm. / Max (Unit) RFS
14 Density (Unit) RFS
15 Viscosity (Unit) RFS
16 Pressure Drop RFS
17 Type Coriolis Mass Type
18 Principle Coriolis
19 Sensor Type U–tube
FLOW METER /
20 Tube / Wetted Part Material RFS
SENSOR
21 Sensor Size STS
22 Process Connection Flanged 150#, ANSI B 16.5 RF, Size STS
23 Flow Range RFS
24 Type 4 Wire Electronic
25 Input From Sensor
26 Output Signal 4-20 mA DC, HART
27 Power Supply 24 VDC
± 0.1 % of measured value(Liquids), 0.75 % of measured value(Gases), Density ±0.001
28 Accuracy
g/cm³ (±1 kg/m³)
FLOW 29 Repeatability ± 0.05 % of measured value
TRANSMITTER
30 Local Indication LCD, Digital Display in Engg. Units
31 Cable Entry 1/2” NPT (F) – 2 Nos.
Hazardous Area - ATEX Explosion Proof , Exd Suitable for Zone-1, Gr. IIA,IIB,
32 Enclosure Protection
T4-T6
33 Enclosure Material Die Cast Aluminium Polyurethane Coating
34 Mounting Remote
35 Inter Connecting Cable 5 meter
OPTIONS 36 Mounting Bracket SS 304
37 Totalizer Required
38 SS Tag Plate Required
39 Certification ATEX
OTHERS
40 Make STS
41 Model No. STS
1) NA - Not Applicable
2) STS - Supplier to Specify
3) RFS - Refer Follow Sheet
NOTES :
4) Vendor to highlight deviation if any.
5) Vendor shall submit Mat. Test Report, Performance Test Report, Calibration Guarantees etc. in triplicate along with delivery.
6) Vendor to submit sizing calculations and detailed catalogue along with the offer.
IPS-DOC-03-IN-V1.0 2 of 3 562024520.xlsx
IPS-MEHTALIA PVT. LTD. Client NSCL
Consulting Engineers . Construction Management . Commissioning & Qualification Project No. MBD21907
Unit B 101-109, 1st Floor, Kailash Vaibhav Ind Complex, Park Site, Vikhroli (W), Mumbai - 79 Made/ Chkd. NPK/SSP
Document Title:- Data sheet of Flow Transmitter - Mass Type Rev A
Document No.:- IPS-MBD21907-IN-510A Date 19-Jul-2021
DATA SHEET OF FLOW TRANSMITTER - MASS TYPE
Operating Flow Flow Range Operating Pressure Operating Temperature
Nature of Fluid (Clear / Meter m3/hr m3/hr Kg/cm2 (g) °
C Tube ID
Line Material Process Connection Density Viscosity Pressure Drop Transmitter Body Density Accuracy Mounting
Sr. No. Tag No. P&ID No. Rev. No. Location / Line / Equipment No. Fluid / Service Fluid State Viscous / Slurry / Line Size (NB) Line Material Size Tube MOC Flange MOC Sensor Body MOC mm Flow Accuracy Area Clssification Remarks
Code Size, Type & Std. Kg/m3 cP Kg/cm2 (g) Housing MOC *optional Bracket
Corrosive) NB
Min Nor. Max. Min Nor. Max. Min Nor. Max. Min. Nor. Max.
Zone 1, Gas Gr. IIA IIB,
1 FT-DT-22102 IPS-MBD21907-PR-4031 B PR-403108-SS304-50 Process 50 SS304 SS304 STS STS STS STS STS STS STS STS STS
T4- T6
Zone 1, Gas Gr. IIA IIB,
2 FT-R-12105 IPS-MBD21907-PR-4038 B PR-403603-SS316-80 Process 80 SS316 SS316 STS STS STS STS STS STS STS STS STS
T4- T6
Zone 1, Gas Gr. IIA IIB,
3 FT-R-12106 IPS-MBD21907-PR-4039 B PR-403603-SS316-80 Process 80 SS316 SS316 STS STS STS STS STS STS STS STS STS
T4- T6
Zone 1, Gas Gr. IIA IIB,
4 FT-R-11108 IPS-MBD21907-PR-4042 B PR-404202-SS304-50 Process 50 SS304 SS304 STS STS STS STS STS STS STS STS STS
T4- T6
Zone 1, Gas Gr. IIA IIB,
5 FT-V-10123 IPS-MBD21907-PR-4048 B PR-404804-SS316-25-IH Process 25 SS316 SS316 STS STS STS STS STS STS STS STS STS
T4- T6
Zone 1, Gas Gr. IIA IIB,
6 FT-V-10124 IPS-MBD21907-PR-4048 B PR-404812-SS304-80 Process 80 SS304 SS304 STS STS STS STS STS STS STS STS STS
T4- T6
Zone 1, Gas Gr. IIA IIB,
7 FT-SPF-10101 IPS-MBD21907-PR-4050 B PR-405001-SS316-50 Process 50 SS316 SS316 STS STS STS STS STS STS STS STS STS
T4- T6
Zone 1, Gas Gr. IIA IIB,
8 FT-P-70708 IPS-MBD21907-PR-4199 B PR-419902-MSTL-50 Process 50 CS CS STS STS STS STS STS STS STS STS STS
T4- T6
Note STS: Supplier to Specify
IPS-DOC-03-IN-V1.0 3 of 3 562024520.xlsx