Cooling& Heating Time Calculation

Heat transfer in agitated vessels can occur through an external jacket or internal coils. A jacket provides a simpler design that covers the full vessel surface but has lower heat transfer performance than coils. Coils provide a larger surface area but require a more complex, two-piece vessel design. The choice depends on factors like corrosion resistance, surface area needs, and material properties. Heat transfer calculations consider the overall heat transfer coefficient based on individual coefficients for the process and service sides.

Uploaded by

Sandesh Lawand
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
289 views6 pages

Cooling& Heating Time Calculation

Heat transfer in agitated vessels can occur through an external jacket or internal coils. A jacket provides a simpler design that covers the full vessel surface but has lower heat transfer performance than coils. Coils provide a larger surface area but require a more complex, two-piece vessel design. The choice depends on factors like corrosion resistance, surface area needs, and material properties. Heat transfer calculations consider the overall heat transfer coefficient based on individual coefficients for the process and service sides.

Uploaded by

Sandesh Lawand
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

AGITATED VESSEL HEAT TRANSFER

Heat transfer in agitated vessels can be carried out either through an external jacket on the vessel
or by internal coils. Where a jacket or coils cannot provide the surface area required, a
recirculation loop with an external heat exchanger may be used. A jacket may be either a full
conventional jacket, a dimpled jacket, or a half-pipe jacket, often called a limpet coil, as
illustrated in Figure 1a, Figure 1b and Figure 1c. The designs are compared by Markovitz (1971).

Figure 1.
A conventional jacket has the advantage that it covers the full wall and base surface and is very
simple to construct. A dimpled jacket allows construction from light gauge metals while
maintaining strength. A half-pipe jacket may be cheaper for a high pressure on the service side
and has the advantage that more than one service can be supplied to different sections of the
wall. However, a limited amount of the surface will be covered by a half-pipe jacket, the large
amount of weld can cause mechanical concerns where thermal cycling occurs and the jacket
welding must be spaced from the dished end main welds to maintain mechanical integrity of the
vessel wall.
Internal coils may be full helical coils, or a number of smaller, ringlet coils. Figure 2a and b.
Figure 2.
A full helical coil is the more usual design, allowing the maximum surface to be installed, but
requires a two-piece vessel with a relatively expensive main flange. Smaller ringlet coils can be
designed to be inserted through large branches on the upper vessel dished end, but can leave
quiescent, unmixed regions within their circumference.
The choice between a jacket and coils is based on a number of considerations. For highly
corrosive or highly reactive materials, a jacket has the advantage that there are no extra materials
of construction and no extra metal surface in contact with the process other than the normal
vessel wall. There is also less risk of cooling fluid coming into contact with the reaction mass. For
the manufacture of pharmaceuticals, fine chemicals and performance products, a jacket
minimizes contamination as there are no extra surfaces to clean. For materials with difficult
rheology the full range of agitator designs can be used with a jacket without difficulty. However,
a jacket has a lower heat transfer performance than a coil as there will be a lower process side
coefficient, usually a greater wall thickness, and a smaller surface area. A jacket may also require
a higher service side flow. For exothermic reactions, a jacketed vessel has the disadvantage that
the area/volume ratio decreases with increasing scale. The use of a greater height/diameter ratio
at larger scale can help to reduce this problem, but only to a limited extent. A coil has the
advantage that a large surface area can be provided, for example, in one particular highly
exothermic reaction 18 m2m−3 has been installed in a 5 m3 reactor. However, it is important not to
pack the coil so tightly as to form a false wall.
Agitated vessel heat transfer is commonly used in batch manufacture where it is frequently
necessary to calculate the time to heat or cool a batch or the cooling capacity required to hold an
exothermic or endothermic reaction at constant temperature. It may also be necessary to define
the stable operating region or acceptable reagent addition rate for an addition controlled highly
exothermic semi-batch reaction. The heat removal rate is defined by:
(1)

For the simple case of the time to cool or heat a batch of mass, M:
(2)

For a constant service side temperature, T s , for example, steam heating:

The time to reach a temperature, T from a starting temperature T t=0 is:

(4)

For more complex situations numerical integration may be required, but there are many suitable
dynamic simulation languages available. For coils and jackets, the Overall Heat Transfer
Coefficient can be calculated in the usual way:

(5)

where α and α s are the process and service side heat transfer coefficients, respectively. The
service side fouling resistance, l/α f , will be available from local experience or from Kern (1950) ,
for example. As a general guide, approximate overall coefficients typical of agitated jacketed
vessels are given in Tables 1 and 2.
Table 1. Typical overall coefficients for jacketed glass lined steel vessels
Duty U (W m−2K−1)
Distillation/Evaporation 350
Heating 310
Cooling 200
Cooling (chilled service) 100
Table 2. Typical overall coefficients for jacketed carbon and stainless steel vessels
Duty U (W m−2K−1)
Heating 400
Cooling 350
Cooling (chilled service) 150
A typical overall coefficient for a well designed coil would be 400 to 600 Wm2K−1.
Service heat transfer coefficient
Under normal circumstances the overall coefficient should be dominated by the process side.
However, for the service side the following guidelines should be observed to ensure good
performance:
For jackets:
1. A conventional jacket should be fitted with baffles (see Figure 1a).
2. Service injection nozzles should be used to direct the service flow, especially for a glass-lined
steel vessel (see Figure 3).
3. A vent should be fitted and maintained to prevent gas blanketing.
4. For a plain jacket with liquid service the target circumferential velocity should be 1-1.5 ms−1.
5. For a half-pipe jacket with liquid service the minimum target velocity should be 2.3 ms−1.
6. For a dimpled jacket with liquid service, pressure drop may limit the velocity to 0.6 ms−1.

Figure 3. Service injection nozzle.


For an internal coil:
1. For a liquid service, the minimum target velocity should be 1.5 ms−1.
There are several correlations available for the service side coefficient, depending on the jacket or
coil design and the flow regime of the service fluid. Fletcher (1987) provides some useful
guidance and the research club, HTFS has also produced a design report for members. The
following correlations are recommended:
1. Conventional unbaffled jacket, liquid service with high flow [(Lehrer (1970)]
2.
(6)

where:
(7)

v i is the velocity at the inlet nozzle or branch and v B is the velocity component due to
buoyancy, D j is the jacket diameter and D T is the vessel diameter.

(8)

where V is the volumetric flow rate, d i is the diameter of the inlet, z is the wetted height of the
jacket, β is the fluid thermal expansion coefficient, and ΔT s is the temperature rise of the
service fluid. V A is the rise velocity in the jacket annulus and depends on the inlet orientation:
(9)
3. Conventional unbaffled jacket, liquid service with high flow [(Lehrer (1970)] (see also Free
Convection)
(10)

Here,
K = 0.15 for upward flow, heating; downward flow cooling;
K = 0.128 for downward flow heating; upward flow cooling;
ΔT m is the mean temperature difference between the service and the vessel wall
(11)

4. Baffled or dimpled jacket, liquid service. The service side coefficient for a baffled or dimpled
jacket will be greater than for an unbaffled jacket with high flow, therefore the above can be
used as a conservative estimate. Using the correlation for a half-pipe coil with the flow area
equivalent to the baffle channel is not recommended as it may give an overestimate.
5. Half-pipe coil, liquid service
(12)

This is the normal Sieder-Tate equation, (see Forced Convective Heat Transfer) applied to the
whole jacketed area with the effectiveness factor (E) from Kneale (1969), typically 0.8–1. Nu
and Re are based on the hydraulic mean diameter, d e :
(13)

6. Condensing service. A condensing coefficient in a jacket should be extremely high compared


to the process side and normally α s −1 ~ 0. A conservative estimate can be obtained from the
Nusselt analysis [see Kern (1950)]:
(14)

The physical properties refer to the liquid phase and ΔT = T sat - T wall (see Condensation).
Process side heat transfer coefficient
The process side coefficient will be determined by the agitator type and speed. (See
also Agitation Devices.) For low viscosity fluids, most turbine-type high-speed agitators can
give good performance. For high viscosity and Non-Newtonian Fluids, larger diameter agitators
will be required. Harnby et al. (1985) and Oldshue (1983) provide guidance on agitator selection.
For Non-Newtonian Fluids, there are two important considerations:
1. A mean apparent viscosity is required to calculate Nu from Re. The normal practice is to
estimate it using the Metzner-Otto approach, where:
(15)

K mo depends on the agitator type, N is the rotational speed (s -1).


The viscosity correction only allows for the effect of temperature near the wall and NOT the
distribution of shear rate. It will normally be sufficient to assume an homogeneous
distribution of shear rate. Calculation of a wall shear rate to predict a local η a is beyond the
scope of this article.
2. It is essential to ensure that a material with a significant yield stress is maintained fluidized
right up to the vessel wall. Nienow (1988) reviews the design techniques. Use the vessel
diameter (D T ) as the diameter of the region to be fluidized:
(16)

Po is the impeller Power number [Harnby et al. (1985)], and:


(17)

For the vessel wall surface, the process side coefficient can be calculated from:
(18)

(19)

For transfer to an internal coil:


(20)

Table 3. Metzner-Otto constants for impellers


Impeller type K mo
propeller 10
disc or flat blade turbine 11.5
angled turbine 13
anchor 25*
helical ribbon 30
EKATO Intermig (0.8 D T ) 40
*The value for an anchor depends on the rheology of the material, for more detail see
Nienow (1988).
Table 4. Heat transfer constants for impellers
Impeller A B
propeller 0.461.4
45° turbine 0.611.4
disc turbine 0.871.4
retreat curve0.330.87
anchor 0.33
Intermig 0.54
Wall resistance
The conductivity of the wall material can be found in standard texts [Kern, (1950)]. The
resistance may be significant for some vessels linings, for example, glass lined steel, where the
manufacturer's data should be consulted. There will also be some limitations on the ability of
glass lining to withstand thermal shock