Continuous Emissions Monitoring
and Process Control
O2000N Oxygen Analyser
P83N
Continuous Emissions Monitoring
and Process Control
O2000N Oxygen Analyser
The OPSIS O2000N Oxygen analyser is designed OPTIONS
for measuring oxygen in industrial, process and Several options are available such as:
continuous emissions monitoring applications. Since
the oxygen analyser measures the oxygen contents • Extended length of the probe
in the flue gas directly, there is no need for sample • High temperature kit for process temperatures
extraction systems. up to 1800°C
• Probe designed for very corrosive environments
The standard OPSIS Oxygen package includes an • Flame arrester to prevent explosion in the process
analyser and a probe with a 10 m. connection cable. • Automatic two point calibration with pump
• Automatic two point calibration for compressed air
FEATURES
• Up to 100 m. cable length between probe and
The analyser contains an embedded micro controller analyser
for fast and easy operation. It is user friendly with
a 4 × 20 characters OLED display.
Other key features are:
• Built-in diagnostics of probe and analyser
• 115/220 VAC Operation
• High and low O2 alarm output
• System failure alarm
• Soft start of probe heater
6 touch pads for
• Active temperature regulation of probe easy controlling of
• Dual range isolated analogue output all analyser functions
(internal)
• Modbus communication
4 × 20 characters
Internal OLED display (internal)
Fittings for connection
of calibration gas and
reference air
Junction box
for electrical
connections
Filters – easy
access to filter
change
O2000N EXTERNAL DISPLAY O2000N INTERNAL DISPLAY
TECHNICAL SPECIFICATIONS: ANALYSER O2000N TECHNICAL SPECIFICATIONS: PROBE 502N
Measuring range 0–25% Vol. Max. stack gas temperature 600°C
Accuracy According to EN15267 Sensor type ZrO2 (Zirconia)
Lag time <2 sec Material AISI 316 Stainless steel
Response time <5 sec Mounting 3” Withworth pipe thread
Warm-up time <15 min DIN ISO 228
Power supply 100–240 VAC 50–60 Hz Total length 390 / 730 / 1730 mm
Power consumption <60 VA warm up Insert length 200 / 500 / 1500 mm
<20 VA steady state Weight
Dual isolated (incl. cable and socket) 4 kg / 5.3 kg / 8.4 kg
analogue output 2 x 0/4-20 mA, Cable length (Standard) 10 m
Max. load 500 Ω
Relay output
High level 4 x 30VDC 1A,
Low Level 125VAC 0.5 A
Alarm
Calibration
Max. ambient temperature 50°C
Max. humidity 90% RH
Enclosure IP 65
Dimensions internal
display (H×W×D) 380 × 300 × 210 mm
External
display (HxWxD) 300 x 380 x 210 mm
Weight 10 kg
Isolated serial
interface Modbus RTU
Continuous Emissions Monitoring and Process Control
Continuous Emissions Monitoring
and Process Control by OPSIS
Continuous, direct oxygen measurement
Complete system package for easy installation and start-up
Cost-effective monitoring of O2
Well-proven design
Dual isolated current and output
Modbus communication
Automatic two point gas calibration (option)
P83N Please contact your OPSIS supplier to discuss your particular system requirements, including the
compounds you wish to monitor. Separate product and other industrial application sheets are available.
2021 08 Specifications subject to change without notice
OPSIS AB
Box 244, SE-244 02 Furulund, Sweden