0% found this document useful (0 votes)
175 views14 pages

Deep Sea Electronics PLC: DSE103 MKII Speed Switch PC Configuration Suite Lite

Uploaded by

Mostafa Shanna
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
175 views14 pages

Deep Sea Electronics PLC: DSE103 MKII Speed Switch PC Configuration Suite Lite

Uploaded by

Mostafa Shanna
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 14

DEEP SEA ELECTRONICS PLC

DSE103 MKII Speed Switch PC Configuration


Suite Lite

Document Number 057-136


Author: Anthony Manton

DSE103 MKII Speed Switch PC Configuration Suite Lite Issue 1


DEEP SEA ELECTRONICS PLC
Highfield House
Hunmanby
North Yorkshire
YO14 0PH
ENGLAND

Sales Tel: +44 (0) 1723 890099


Sales Fax: +44 (0) 1723 893303

E-mail : [email protected]
Website : www.deepseaplc.com

DSE103 MKII Speed Switch

© Deep Sea Electronics Plc


All rights reserved. No part of this publication may be reproduced in any material form (including photocopying
or storing in any medium by electronic means or other) without the written permission of the copyright holder
except in accordance with the provisions of the Copyright, Designs and Patents Act 1988.
Applications for the copyright holder’s written permission to reproduce any part of this publication should be
addressed to Deep Sea Electronics Plc at the address above.

The DSE logo and is a UK registered trademark of Deep Sea Electronics PLC.

Any reference to trademarked product names used within this publication is owned by their respective
companies.

Deep Sea Electronics Plc reserves the right to change the contents of this document without prior notice.

Amendments List

Issue Comments Minimum Minimum


Module Configuration Suite
version Version required
required
1 Initial release 1

Typeface: The typeface used in this document is Arial. Care should be taken not to mistake the upper case letter I with the numeral 1. The
numeral 1 has a top serif to avoid this confusion.

2
TABLE OF CONTENTS

1 BIBLIOGRAPHY .......................................................................................... 4
2 DESCRIPTION ............................................................................................. 4
3 INSTALLATION INSTRUCTIONS ................................................................. 5
3.1 SOFTWARE INSTALLATION............................................................................................................. 5
3.1.1 MINIMUM SYSTEM REQUIREMENTS.......................................................................................................................... 5
3.1.2 INSTALLATION.................................................................................................................................................................. 5
3.1.3 TROUBLESHOOTING SOFTWARE INSTALLATION ................................................................................................ 7
3.1.3.1 WINDOWS 7 .................................................................................................................................................................7
3.1.3.2 WINDOWS VISTA .........................................................................................................................................................7
3.1.3.3 WINDOWS XP...............................................................................................................................................................7
3.1.3.4 WINDOWS NT, WINDOWS MILLENIUM, WINDOWS 98, WINDOWS 95, WINDOWS 3.1 ............................................7
3.1.3.5 APPLE MAC, WINDOWS CE, PALM OS, SMARTPHONE, PDA, ANDROID, LINUX, UNIX ..........................................7
3.2 HARDWARE INSTALLATION ............................................................................................................ 8
3.3 TROUBLESHOOTING INSTALLATION............................................................................................. 8
4 USING THE CONFIGURATION SUITE ......................................................... 9
5 MENUS AND TOOLBAR ............................................................................ 10
5.1 FILE MENU ....................................................................................................................................... 10
5.2 TOOLS MENU................................................................................................................................... 11
5.3 HELP MENU ..................................................................................................................................... 11
5.4 TOOLBAR ......................................................................................................................................... 11
6 EDIT CONFIG............................................................................................. 12
6.1 SCREEN LAYOUT............................................................................................................................ 12
6.2 SPEED AND FREQUENCY SENSING............................................................................................. 12
6.3 TRIP SETTINGS ............................................................................................................................... 13
6.4 INPUTS AND OUTPUTS .................................................................................................................. 13

3
1 BIBLIOGRAPHY
This document refers to and is referred to by the following DSE publications which can be obtained from the
DSE website www.deepseaplc.com:

DSE PART DESCRIPTION


057-135 DSE103 speed switch operator manual

2 DESCRIPTION
This manual covers the operation of the DSE Configuration Suite Lite for DSE103 speed switch module.
Separate manuals cover the remaining DSE modules supported by the software.

The DSE Configuration Suite Lite allows the DSE103 module to be connected to a PC via DSE890 USB
conversion adaptor. Once connected the various operating parameters within the module can be viewed or
edited as required by the engineer.

The configuration suite should only be used by competent, qualified personnel, as changes to the operation of
the module may have safety implications on the panel / generating set to which it is fitted.

The information contained in this manual should be read in conjunction with the information contained in the
appropriate module documentation. This manual only details which settings are available and how they may
be used.
A separate manual deals with the operation of the individual module (See section entitled Bibliography
elsewhere in this document).

4
Installation

3 INSTALLATION INSTRUCTIONS
3.1 SOFTWARE INSTALLATION

3.1.1 MINIMUM SYSTEM REQUIREMENTS


Operating System Windows 7, Windows Vista, Windows XP with Microsoft™ .Net® 4.0 framework
Monitor 17 inch recommended (1024 x 768 resolution)
Communications USB required to configure the module via DSE890 interface

NOTE: - As DSE configuration software for Windows™ is a 32 or 64 bit application requiring


Microsoft .net 4 framework, it will not operate on Windows 2.0, 3.0, 3.1,3.11, 95, 98 or Me.

NOTE: - Microsoft .Net 4.0 Framework can be obtained from Microsoft’s website. Alternatively, it
is included in the DSE Configuration Suite Software CD version which can be obtained on CD from
Deep Sea Electronics PLC (DSE Part number 0806-001-15) or by downloading the ‘CD version’ from
the DSE website.

NOTE: - Exit all other programs before installing the software. It is recommended that any earlier
releases of the software be uninstalled prior to installing this version.

NOTE: - Please register online at www.deepseaplc.com – Once registered you will be able to
download updates to the software to ensure that you always have access to the latest features.

3.1.2 INSTALLATION
Insert the Software CD into the CD-ROM drive on the PC. The CD will then Auto-run if this feature is enabled
on your PC.

Alternatively:

• Double click on Computer

• Double click on CD-ROM Drive

• Double click CDSetup

Click Next to continue

5
Installation

Click Next to continue

Click Install to continue and install the Configuration Suite Lite Software.

6
Installation

3.1.3 TROUBLESHOOTING SOFTWARE INSTALLATION


It is very rare that problems are encountered when installing the system, however if problems arise, use the
following checklist to troubleshoot your software installation

3.1.3.1 WINDOWS 7
32 bit and 64 bit versions

• Ensure the operating system is logged onto using an Administrator Account. Failure to do this results
in installation failure due to incorrect user permissions disallowing registration of some parts of the
Configuration Suite Software.
• When installing the software, instead of clicking the icon with the left mouse button, click on the
installation icon with the right mouse button, then select Run as Administrator.
• Ensure the operating system is fully up to date using the Microsoft Windows Update facility.
• Ensure that Windows Installer is fully up to date using the Microsoft Windows Update facility.
• Ensure the operating system has Microsoft .net 4 Framework redistributable (for x86) installed and is
fully up to date. This is available from Microsoft’s website.

3.1.3.2 WINDOWS VISTA


32 bit and 64 bit versions

• Ensure the operating system is logged onto using an Administrator Account. Failure to do this results
in installation failure due to incorrect user permissions disallowing registration of some parts of the
Configuration Suite Software.
• When installing the software, instead of clicking the icon with the left mouse button, click on the
installation icon with the right mouse button, then select Run as Administrator.
• Ensure the operating system is fully up to date using the Microsoft Windows Update facility.
• Ensure that Windows Installer is fully up to date using the Microsoft Windows Update facility.
• Ensure the operating system has Microsoft .net 4 Framework redistributable (for x86) installed and is
fully up to date. This is available from Microsoft’s website.

3.1.3.3 WINDOWS XP
• Ensure the operating system is logged onto using an Administrator Account. Failure to do this results
in installation failure due to incorrect user permissions disallowing registration of some parts of the
Configuration Suite Software.
• Ensure the operating system is fully up to date using the Microsoft Windows Update facility.
• Ensure that Windows Installer is fully up to date using the Microsoft Windows Update facility.
• Ensure the operating system has Microsoft .net 4 Framework redistributable (for x86) installed and is
fully up to date. This is available from Microsoft’s website.

3.1.3.4 WINDOWS NT, WINDOWS MILLENIUM, WINDOWS 98, WINDOWS 95,


WINDOWS 3.1
• DSE Configuration Suite does not support these operating systems. It is recommended that the
system is operated under Windows 7, Windows Vista or Windows XP operating systems.

3.1.3.5 APPLE MAC, WINDOWS CE, PALM OS, SMARTPHONE, PDA, ANDROID,
LINUX, UNIX
• DSE Configuration Suite requires a Windows Personal Computer (PC) running the full version of
Windows. (Windows 7, Windows Vista or Windows XP operating systems).

7
Installation

3.2 HARDWARE INSTALLATION


Ensure the Configuration Suite Lite Software is installed on the PC as described above.
The installation of the PC software also installs the DSE890 USB Driver automatically.
Connect the DSE890 USB cable to the PC as shown and the DSE890 to the module.

Windows detects the module when power is applied to it.

You are now ready to configure or monitor the module using the Configuration Suite Software.

3.3 TROUBLESHOOTING INSTALLATION

Occasionally USB devices are disabled by the Windows operating system, the following procedure will re-
enable the device in these instances.

• Disconnect the Deep Sea Electronics Controller from the USB port. Wait a moment, then reconnect
and try again. If you still encounter problems then :
• Try another USB cable. If you don’t have one, it’s the same type of cable as usually used between a
PC and a USB printer (Type A to Type B). If you still encounter problems then :
• Disconnect the Deep Sea Electronics module. Shutdown, then restart the PC. Reconnect the
interface, and then try again. If you continue to experience problems then :
• Check the USB port with another device (for instance a mouse, printer or digital camera).

8
Using the Configuration Suite

4 USING THE CONFIGURATION SUITE


To run the Configuration Suite Software for Windows program click the Windows start button

or depending upon your version of Windows.

Then select ‘All Programs’ - ‘Deep Sea Electronics PLC’ – “DSE Configuration Suite Lite”

After a short delay to load the application, the splash screen is shown, after which the screen will
display:-

This is the initial start-up screen and can be disabled by checking the box Hide this screen at start-up.
The screen prompts the user to select between the three main uses for the software:

• Creating a new configuration. Select the module type under Create new configuration. This allows
you to create a configuration for the ‘latest’ module version.
• Editing a configuration previously saved to disk or flash memory device. Select the configuration file
either from the Open recent configuration area or by clicking Open a configuration file and browsing
to the file.
• Reading and changing the configuration of a connected module. Click Read configuration from a
module. The file is read from a currently connected DSE103 speed switch and is available for editing
in the Configuration Suite.

Alternatively you can ignore this screen and continue to use the program in the background. Once you make a
connection or load/create a configuration, the start-up screen will disappear.

9
Menus and Toolbar

5 MENUS AND TOOLBAR


The menu and toolbar are located at the top of the screen:

5.1 FILE MENU


Create a new configuration file. You are prompted to select what kind of
module you want to create the configuration for.
The settings of the new configuration file match the factory settings for the
chosen module type.
You can only select to create a configuration file for the ‘latest’ version of
controller.
Open an existing file from disk or flash memory device.
Close the currently open file.
Save the currently open file to the location it was loaded from previously. If this
is a new file, you are prompted to enter a filename.
Save the currently open file, under a new name. You will be prompted to enter
a filename.
Send the currently open configuration settings to the controller.
Read the settings out of the connected controller for viewing / editing.
Print the currently open configuration file.
Preview what the configuration file will look like on the page after printing.
Select printer type and printer settings.
Exit the software. If the currently open file has changed since it was last
saved, you will be prompted to save it.

10
Menus and Toolbar

5.2 TOOLS MENU


Options Opens the Settings screen containing customisation options for the
Configuration Suite.

5.3 HELP MENU


Shows the version number of the configuration suite

5.4 TOOLBAR
The toolbar contains the most used commands from the menus and is often a quicker way of accessing these
commands.
Create a new configuration file
Open an existing file from disk or flash memory device
Save the currently open file to the location it was loaded from previously. If this is
a new file, you are prompted to enter a filename.
Print the currently open configuration file
Send the currently open configuration settings to the controller
Read the settings out of the connected controller for viewing / editing
Select the USB P810 Port (COMx)

If this selection is not available, close the software, check the drivers are correctly
installed (see below), connect the DSE890 interface module and restart the
software.

11
Edit Configuration

6 EDIT CONFIG
This menu allows module configuration, to change the function of Inputs, Outputs and LED’s, system timers
and level settings to suit a particular application.

6.1 SCREEN LAYOUT

The type of
configuration
file being edited

The coloured
shading shows Close this
the currently configuration file
selected page.

Click to select
the subsection
to view / edit

6.2 SPEED AND FREQUENCY SENSING

12
Edit Configuration

6.3 TRIP SETTINGS

Select Potentiometer to allow external


adjustment via the module’s TRIP
potentiometer.
Select Fixed for a fixed trip point.

Select the range of


adjustment allowed using
the external
potentiometer.

Select if the trip is an


‘under’ or ‘over’ trip.
Under trips are governed
by the safety timer.

When ticked, the trip remains


active once tripped.
The trip is reset by power cycling
the module, or activating an input
for reset.

Temporarily raises the


overspeed trip point to
‘ignore’ overshoot during
engine start up.

6.4 INPUTS AND OUTPUTS Allows the input functions to be customised.


None –input is disabled
Reset – resets any latched trip if possible
Set – Sets the current speed as the nominal speed.
Test – Test mode. When active, both relays operate and
the meter output is set to 50% of the maximum output.

Set the full scale deflection (FSD) or


full range marking of the attached
meter.

13