0% found this document useful (0 votes)
145 views4 pages

Samsung LN46C630K1FXZA Fast Track Guide (SM)

This document provides troubleshooting information for various issues with LCD TVs. It includes: 1. A wiring diagram showing the main power connections and sequences for turning on the backlight. 2. Instructions for using test patterns in service mode to troubleshoot video problems such as pixelization, green lines, or a green screen. 3. Examples of on-screen failure patterns and their likely causes, such as vertical or horizontal lines being caused by a defective panel, T-CON, LVDS, or main board. 4. Steps for checking option bytes, performing firmware upgrades, and resetting settings after replacing the main board or panel.

Uploaded by

Carlos Odilon
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
145 views4 pages

Samsung LN46C630K1FXZA Fast Track Guide (SM)

This document provides troubleshooting information for various issues with LCD TVs. It includes: 1. A wiring diagram showing the main power connections and sequences for turning on the backlight. 2. Instructions for using test patterns in service mode to troubleshoot video problems such as pixelization, green lines, or a green screen. 3. Examples of on-screen failure patterns and their likely causes, such as vertical or horizontal lines being caused by a defective panel, T-CON, LVDS, or main board. 4. Steps for checking option bytes, performing firmware upgrades, and resetting settings after replacing the main board or panel.

Uploaded by

Carlos Odilon
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

LN46C630K1FXZA Fast Track Troubleshooting Manual Rev - 1/10/12

SERVICE BULLETINS

POWER 1. 2010 LCD Option Byte Table


PCB

MAIN
Insert Photo of TV Board Layout Version
Include
PCBBoard Assy names (as appearing in parts) and any
Parts No Short Description
special labels/items (i.e. Plasma voltage label) ALL BN44-00341B Power PCB
LVDS DRIVER
Function & IR PCB

CABLE BOARD ALL BN96-13451C


ALL BN94-02701P Main PCB

T-CON PCB ALL BN07-00833B Panel


SPEAKER SPEAKER
(under shield) ALL BN81-04414A T-CON PCB

HELP : BN96-10689A
1-888-751-4086; 1-866-894-0637 (FE) FIRMWARE ALL Stand Guide Neck

GSPN 10/18/2010 ALL BN96-12768B Rear Cover


http://gspn3.samsungcsportal.com Firmware for Valencia 1G Model BN96-12773A
ALL Front Cover
-. Version : 1030.1
ALL BN96-12795C Stand Guide
PLUS ONE -. Folder Name: T-VALAUSC
http://my.plus1solutions.net/clientPortals/samsung -. Related Models LCD: C560 (Only 40"), ALL BN96-12763F Stand Base
C650, C670, C750 ALL BN40-00163A Tuner
HOT TIPS And this firmware prevents below
BN96-12837B
Power On Problems: (see page 2) issues..'USB Power Overload' message ALL Speaker

Video Problems: (see pages 3,4) pops up even USB port is not connected ALL BN96-12723D LVDS Cable
. Plug & Play is displayed whenever 3903-000467
TIP: After replacing Main/Panel turning on TV.
ALL Power Cord

picture is upside down. ALL BN59-01041A Remote

Fix: Test Mode/Mirror Option/Toggle 1


ALL BN63-01798B Cleaning Cloth
LN46C630K1FXZA Fast Track Troubleshooting Manual

CN201

SW-P

Wiring Diagram
Include Connector Numbers , References, and
Locations.

LN46C670M1FXZA

Power
) On Sequence (approximate Voltages)
1. Standby Voltages: CN201-4 (5V) To Force Backlight On
2. Power On CN201-2 (0 – 3V ) without Main Board :
3. Low Voltage Supplies On CN201- 1. Remove Power Cord
1,3,5,7,13,15,17 (Volts Listed on CN802) 2. Remove CN802
4. Back Light On CN201-16 (0-3V, delayed) 3. Plug Power Cord In.
5. Back Light Confirm CNI802- (FB1 & FB2) 4. Backlight should be
6. Dimming Signal CN201-14 (1V–4V approx) on immediately.
2
Fast Track Troubleshooting Manual
TROUBLESHOOTING VIDEO PROBLEMS
1. Verify Video Operation T-Con Troubleshooting
a. Customer Picture Test (models available)
b. “Display” (If display is OK source is suspected)
C. Substitute with known good Source
(external DVD or Signal Generator)

2. Using Test Patterns in Service Mode


- ENTER SERVICE MODE –
1. Select an active source signal. (HDMI preferred)
Test Pattern may rely on signal source to appear.
Customer Remote Service Remote
2. Power off 2. Power On
3. Mute, 182, Power 3. Info, Factory

2010 Models with FRC 120Hz/240Hz

FBE

FRC

1.Check OSD & Customer Picture Test.


2. Access SVC Mode (with source signal)
3. Activate FBE Test Patterns & Verify.
4. Activate FRC Test Patterns & Verify. 3
Fast Track Troubleshooting Manual
ON SCREEN FAILURE EXAMPLES:
ALIGNMENTS:
1. Check/Set Option Bytes:

If Picture & Display errors Green lines or a green screen


Defective Main Board, LVDS, defective main board , LVDS , or
T-CON.
or T-CON

Model Code Front


Color
Type Model Tuner Region Side
Label

LN46C630K1FXZA T-C- LC630


Pixelization can be caused by the main board 46L1AF0C
Semco US
AA06
BLK
but is more commonly a source error

2. Check/Perform Firmware Upgrade for


all repairs.
3. Perform reset in Service Mode &
Plug and Play if Main board is replaced.
SPECIAL NOTES:
Vertical or Horizontal Lines :Defective Inform customer of reset of all
Panel likely but also T-CON, LVDS, or Main Settings if Main Board or Panel is replaced.
Board. Use Test Patterns in Factory Service 4
Mode to determine error)

You might also like