Sofrel Neo: Data Loggers 4G M2M For Drinking Water Networks Monitoring

The document describes three data loggers from Sofrel for monitoring drinking water networks: NEO LC, NEO DMA, and NEO CWT. The loggers collect data via digital and analog inputs and transmit it over 2G/4G networks to central stations for analysis and monitoring. They archive data locally and allow configuration via Bluetooth. The NEO loggers vary in their input/output capabilities and intended uses for large consumers, district metering areas, and clear water telemetry applications.

Uploaded by

Gotaru Minami
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
671 views2 pages

Sofrel Neo: Data Loggers 4G M2M For Drinking Water Networks Monitoring

The document describes three data loggers from Sofrel for monitoring drinking water networks: NEO LC, NEO DMA, and NEO CWT. The loggers collect data via digital and analog inputs and transmit it over 2G/4G networks to central stations for analysis and monitoring. They archive data locally and allow configuration via Bluetooth. The NEO loggers vary in their input/output capabilities and intended uses for large consumers, district metering areas, and clear water telemetry applications.

Uploaded by

Gotaru Minami
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
  • Product Introduction
  • Technical Characteristics

SOFREL NEO

Data loggers 4G M2M for drinking water


networks monitoring

NEO Large Consumer (LC)

NEO District Metering Area (DMA)

NEO Clear Water Telemetry (CWT)

COMMUNICATION NEO LC NEO DMA NEO CWT


DATA TRANSMISSION
- Sending of data to 1 or 2 SCADA Central Stations IP IP IP
- Communication medium 2G/4G M2M 2G/4G M2M 2G/4G M2M
- Exernal antenna ü ü ü
- Temporary exceptions ü ü ü
ALERT
- Instant detection via a specific DI ü ü
- Sensor fault detection ü ü
CENTRALISATION
- SOFREL WEB LS (cloud hosting of data sent by LACROIX Sofrel data loggers) ü ü ü
- SOFREL PCWin2 (SCADA Central Station for SOFREL devices) ü ü ü
- Open to third-party applications (Web services and FTP) ü ü ü
- Analysis and exploitation of data on PC, tablet or smartphone ü ü ü
- Open to other SCADA systems Contact us
INTER-SITES
-
Periodic or event-driven communications (change of DI status or threshold ü ü ü
exceedance) to RTU’s for remote site control

I/O MANAGEMENT
NUMBER OF INPUTS / OUTPUTS
- Digital Inputs (DI) 2 2 0
- Analogue Inputs (AI) 0 2 2
TYPES OF INPUTS / OUTPUTS
- Pulses ü ü
- Dry contact ü ü
- Remote power feeding to third-party sensors ü ü
SENSORS, ETC.
- Flowmeter (pulse metering) ü ü
- SOFREL CPR / CNPR Pressure sensors ü ü

TREATMENT
CALCULATIONS
- Daily district metering balance (night flow, max flow, min flow and daily volume) ü ü
ARCHIVING
- Daily balances and archiving of meters and flows ü ü
Technical characteristics
GENERAL FEATURES

General characteristics Screwless opening system for easy access by the user to the SIM card and battery
Dimensions H 193 x W 155 mm
Weight 800 g
Operating temperature -20°C to +55°C
Storage temperature -25°C to +70°C
Watertightness IP68
Power supply Power supply by:
- Internal lithium battery
- Photovoltaic cell, mains power, micro-turbine or battery kit
- Input voltage : 5-30VDC - Required power : 3W – Inrush current : 3A
- Battery life: 5 years (depending on configuration)
Connector types Waterproof connectors

DATA LOGGER INPUTS


DI (Digital Inputs) 2 Digital Inputs for standard and bidirectional metering and signalling
Maximum frequency: 250 Hz
Minimum pulse time: 2 ms

DC77-Datasheet NEO-DW-En-2021-07 - LACROIX Sofrel - RCS : B 409 065 810 NANTES - Any reproduction or copying of this document, even in part, is illegal without the consent of LACROIX. The same applies to translation,
Polarisation voltage: 3.3V max
Polarisation current: 15μA max
AI (Analog Inputs) 2 Analog Inputs for measuring pressure or level
Remote power feeding to third-party sensors via 4-20mA loop in 12V or 20V

COMMUNICATIONS

Quadriband 2G/4G M2M 4G LTE-M : B1/B2/B3/B4/B5/B8/B12/B13/B18/B19/B20/B25/B26/B27/B28/B66/B85


4G NB-IoT : B1/B2/B3/B4/B5/B8/B12/B13/B18/B19/B20/B25/B28/B66/B71/B85
Quad-band GSM/GPRS/EDGE (850 MHz, 900 MHz, 1800 MHz, 1900 MHz)
SIM cards supported Standard SIM cards (Nano and Micro SIM cards can be installed via adapter)
Antenna External (cable length 1.5m), IP68
Configuration of the Data Logger Daily synchronisation of the Data Logger with SCADA
Communication to 1 or 2 PCs Periodic, programmed or event-based

CONFIGURATION AND COMMISSIONING

adaptation or transformation, arrangement or reproduction by any art or process (Articles L.122-4 and L.122-5 of the Intellectual Property Code).
Bluetooth Data logger configuration via Bluetooth connection
Assistance with commissioning 4G M2M and 2G signal reception measurement
LED for visual diagnosis
LOCAL DATA ARCHIVING

Archiving capacities 100,000 data points