YB21080 Er - Arunachalam ST05-FLOOR SLAB DETAILS STRUCTURAL DRAWING
YB21080 Er - Arunachalam ST05-FLOOR SLAB DETAILS STRUCTURAL DRAWING
W NOTES:
1'-3"
7. CLEAR COVER FOR
FOOTING :2"(50mm)
6'-1012"
3' B/3 B/10 3 "(30mm)
c
S4 PLINTH BEAM :1 16
COLUMN :1 1/2"(40mm)
c/3
c/5
3'
BEAM :1"(25mm)
℄ SLAB :3/4"(20mm)
5
b/5
b/3
8. LAP LENGTH OF BARS : 50Ø, AT COLUMN LAPPING PROVIDE 4"
3'
SPACING OF TIES, NO LAPPING ALLOWED AT BEAM-COLUMN JOINT.
S2 3' 9. DEVELOPMENT LENGTH (Ld) FOR REINFORCEMENT BARS
1'-3"
E IN COMPRESSION : 40Ø E
9'-1012"
b
IN TENSION : 50Ø
b/3
b/5
10. IN CASE OF BEAM REINFORCEMENT, NO LAPPING SHALL BE ALLOWED
℄ IN FOLLOWING PLACES
(a) TOP ROD NEAR COLUMN, L/4 ON EITHER SIDES OF COLUMN
a/5
B/10
a/3
3' B/3 (b) TOP ROD OF CANTILEVER BEAM ALONG THE LENGTH AND
S2
ALSO DEVELOPMENT LENGTH, BEYOND COLUMN
4
a
3' 3' B/5 B/10 (c) BOTTOM ROD AT MID SPAN OF BEAM
1'-3"
11. REMOVAL OF SHUTTERING / FORM WORK
(a) COLUMN : 24 HOURS
a/10
a/10
6'-6"
3'
S1 (b) BEAM SIDES : 24 HOURS
℄ (c) BEAM BOTTOM : LESS THAN 6M SPAN : 14 DAYS
44'-6"
A B1'-3" : MORE THAN 6M SPAN: 28 DAYS
3 ℄ ℄ ℄ (d) SLAB : LESS THAN 20'SPAN : 14 DAYS
: MORE THAN 20'SPAN : 28 DAYS
TYPICAL ONE WAY SLAB REINFORCEMENT DETAILING HOWEVER 7 DAYS STRENGTH OF CONCRETE SHOULD BE 65% OF THE
TARGET STRENGTH, TO REMOVE FORM WORK.
D 12. THIS BUILDING IS DESIGNED FOR GROUND FLOOR + 1. D
10'-412"
S1
S3
NOTE:
2
1. PROVIDE DISTRIBUTION RIENF. 8 @ 8"c/c
A B C D
FIRST FLOOR SLAB LAYOUT Er.ARUNACHALAM
CONTRACTOR
SRI AMMAN BUILDERS
b
b/3
b/3
b/3
b/5
b/5
b/5
℄ ------
B CLIENT B
SCHEDULE OF SLABS
a/5
a/5
a/5
a/3
a/3
a/3
SLAB NO THICKNESS SHORTER SPAN LONGER SPAN
REMARKS
REINFORCEMENT REINFORCEMENT FIRST FLOOR SLAB LAYOUT & REINFORCEMENT
A/10 A/5 B/3 B/5 C/3 C/10 DETAIL DETAILS
S1 5" Y8@6"c/c Y8@6"c/c TWO WAY SLAB
a
S2 5" Y10@6"c/c Y8@6"c/c TWO WAY SLAB A/10 A/3 B/5 B/3 C/5 C/10 Er.Y.BOOPATHI M.E(Struct), M.I.S.T.E,
LICENSED STRUCTURAL ENGINEER -GRADE 1
S3 6" Y12@5"c/c Y10@4"c/c TWO WAY SLAB STRUCTURAL
CONSULTANT
PYRAMID STRUCTURAL CONSULTANT
S4 Y10@4"c/c Y8@8"c/c
Contact No : +91 9597691155
5" ONE WAY SLAB
a/10
a/10
a/10
a/10
a/10
a/10
Mail id :[email protected]
℄ Scale 1:100
DRAWN CHECKED APPROVED
A A B C Date 22-11-2021 A
℄ ℄ ℄ ℄ AS KR Y.BOOPATHI Paper A3
Size
TYPICAL TWO WAY SLAB REINFORCEMENT DETAILING Rev.no R0
DRAWING NO:- YB-21080-ST-05
Sheet.no (05 OF 06)
1 2 3 4 5 6 7 8 9 10