Rain Stack Pipe Ø 110 F/Up: Soil Pipe Ø160 at Slope 0.5 % Under Ground FD FD Soil Pipe Ø160 FD C.O C.O C.O C.O
Rain Stack Pipe Ø 110 F/Up: Soil Pipe Ø160 at Slope 0.5 % Under Ground FD FD Soil Pipe Ø160 FD C.O C.O C.O C.O
20
Road L.
01
01
A-200-010 01
A-300-040
A-300-020
01 02 03 04 05 06 07 08 09 10 11 12 13 14
37050
2100 5200 1150 2850 1550 2850 550 800 1900 2050 2300 1750 12000
FD C.O +0.45
01 +0.45 01
FD F.F.LRAIN GULLY
1700
F.F.L C.O SOIL PIPE Ø160 @ SLOPE 0.5 % UNDER GROUND C.O
A-300-030 Court A-300-030
2100
2100
C.O
1500
Ø 110 AFC
800
C.C.O. Maid's Room
Dirty Kitchen
110 mm VENT PIPE TO ROOF
C.C.O. 110 mm VENT PIPE TO ROOF
Gr- 19 Gr- 17
WASTE STACK PIPE Ø 110 T/DN SOIL STACK PIPE Ø 110 T/DN
RAIN STACK PIPE Ø 110 F/UP Kitchen
WASTE STACK PIPE Ø 110 F/UP
SOIL STACK PIPE Ø 110 T/DN WASTE STACK PIPE Ø 110 T/DN
+0.17 Gr- 13
Road L.
SOIL STACK PIPE Ø 110 F/UP C.O
RAIN STACK PIPE Ø 110 F/UP +0.63
F.F.L FD
Dining Family Sitting Toilet
Gr- 09 Gr- 10 Main Stair Gr- 07
+0.63 +0.63 Gr- 11
5600
5600
5100
F.F.L F.F.L
C C
Wash +0.45
+0.63 C.O
Gr- 08
2200
RAIN STACK PIPEElevator
Ø 110 T/DN
2" V.P Gr- 15 Toilet FD
19000
19000
Gr- 07
DRAIN STACK PIPE Ø 110 F/UP D
200300 400 500
+0.12
Road L.
Garden SOIL PIPE Ø160 @ SLOPE 0.5 % UNDER GROUND
Gr- 02
7700
SEWERAGE PIPE Ø160 @ SLOPE 0.5 % UNDER GROUND
Water Fall
+0.45 02 +0.45
Gr- 16
1600
4900
4900
F.F.L Main Entrance F.F.L
Pressurized Pipe
+0.10 +0.25
Gr- 01 A-700-020
Road L. Curb L.
PRESSURIZED STACK PIPE Ø110 F/DN Ext. Sitting
Gr- 04
+0.45
1430
E E
740
-3.90 SOIL STACK PIPE Ø 110 T/DN SOIL STACK PIPE Ø 110 T/DN
F.F.L
A-800-022
A-800-011
WASTE STACK PIPE Ø 75 T/DN WASTE STACK PIPE Ø 75 T/DN Garden
01
01
01
Gr- 02
1030
A-300-010
Garden Under Ground Water Tank
500
4200
Ext. Stair F.F.L C.O Gr- 14
3700
700
BS- 07 +0.63
CHECK VALVE ( NON
F.F.L RETURN VALVE ) 01
700
+0.05
Road L. F WATER METER&VALVE F
+0.32 ASSEMBLY BOX
2100 5200 1150 2850 1550 2850 550 800 1900 2050 2300 1750 12000
37050
± 0000
Road L.
01 02 03 04 05 06 07 08 09 10 11 12 01
13 14
01
SANITARY
SA
A-300-040 A-300-020
01
A-200-010
GR
01
01
A-200-010 01
A-300-040
A-300-020
01 02 03 04 05 06 07 08 09 10 11 12 13 14
37050
2100 5200 1150 2850 1550 2850 550 800 1900 2050 2300 1750 12000
2000 3200 1500 5100 1950 2300 3100 800 3500 1600 3100 8900
1000
01 RD SLOPE 0.5%
01
SOIL STACK PIPE Ø 110 T/DN / WET VENT
A-300-030 A-300-030
2100
2100
700 300
.5%
SOIL STACK PIPE Ø 110 T/DN / WET VENT PE 0 WASTE STACK PIPE Ø 110 T/DN
SLO
+5.13 WASTE STACK PIPE Ø 110 T/DN / WET VENT
WASTE STACK PIPE Ø 110 T/DN / WET VENT Roof RAIN STACK PIPE Ø 110 T/DN SOIL STACK PIPE
Roof +5.13Ø 110 T/DN
S S.S.L
SLOPE 0.5%
St-LO01
PE 0
.5 St- 01 S.S.L
BRAIN STACK PIPE Ø 110 T/DN 110 mm VENT PIPE TO ROOF
%
B
.5%
Court
PE 0
+5.13
RD RAIN GULLY
Court RAIN GULLY
S.S.L St- 04 FD 110 mm VENT PIPE TO ROOF
1500
SLO
FD Bath 4 Bath 2
RAIN STACK PIPE Ø 110 F/UP St- 04 Dressing 1
St- 16 St- 09
+5.13 St- 06
S.S.L Bath 3 FD
4400
SLOPE 0.5%
St- 13 Roof
.5% St- 01
PE 0 Pantry
SLOPE 0.5%
5600
5600
St- 10 + 3.63
Dressing 4
SL O
Terrace
S.S.L
St- 15 +5.23 St- 03
.5%
F.F.L +5.13
PE 0
+5.13 S.S.L
Bedroom 3
SLO
S.S.L Dressing 3 + 3.93
St- 11 Main Stair Bedroom 2
St- 12 T.O.P
Roof +5.23 St- 21 St- 08
F.F.L
6300
1200
St- 01 +5.23
F.F.L
.5%
SLOPE 0.5%
PE 0
SLOPE 0.5%
C C
SLO
Bedroom 4 +5.23
RAIN STACK PIPE Ø 110 T/DN
2200
2200
St- 14 Lobby Lobby
2500
F.F.L 110 mm VENT PIPE TO ROOF
St- 20 St- 20 Elevator
.5%
2" V.P +5.23
Gr- 15
PE 0
F.F.L
19000
19000
RD
SLO
RD
D Ø 110 SLEEVE PIPE
D
RAIN GULLY
+5.13 +5.13 RAIN STACK PIPE Ø 110 T/DN
Court
1500
St- 02
4900
4900
SLO
5100
+5.23
F.F.L
Bedroom 1
Bedroom 5 St- 05
St- 17 Bath 5 Bath 1
+5.23
FD
+5.23 St- 19 WASTE STACK PIPE Ø 110 T/DN St- 07
FD SOIL STACK PIPE Ø 110 T/DN F.F.L
F.F.L
5400
RAIN STACK PIPE Ø 110 T/DN WASTE STACK PIPE Ø 110 T/DN
SOIL STACK PIPE Ø 110 T/DN
.5%
E E
PE 0
SLOPE 0.5%
SLO
+5.13
RAIN GULLY
01 S.S.L
A-300-010 Terrace
2000
St- 03 Roof
RAIN STACK PIPE Ø 110 F/UP St- 01
+ 3.93
4200
4200
T.O.P
300
100
+ 3.63
A-800-022
200
S.S.L 01
01
700
A-300-010
1700
300 500
A-800-011
F F
01
100
300 500 700 500 300 800 650 2500 3150 1200 5000 450 300 1000 600 4400 800 200 1600 2800 1800 400 2000 400 1800 2500 300
2100 5200 1150 2850 1550 2850 550 800 1900 2050 2300 1750 12000
37050
01 02 03 04 05 06 07 08 09 10 11 12 01
13 14
01
A-300-040 A-300-020
01
A-200-010
F
01
01
A-200-010 01
A-300-040
A-300-020
01 02 03 04 05 06 07 08 09 10 11 12 13 14
37050
2100 5200 1150 2850 1550 2850 550 800 1900 2050 2300 1750 12000
2000 5700 1100 3450 800 3000 3100 800 3500 13600
01
A-700-011
A A
1000
1000
01 01
A-300-030 A-300-030
2100
2100
300 700 300
700 300
WASTE STACK PIPE Ø 110 T/DN / WET VENT
RAIN STACK PIPE Ø 110 T/DN RAIN STACK PIPE Ø 110 T/DN 110 mm VENT PIPE TO ROOF SOIL STACK PIPE Ø 110 T/DN / WET VENT
110 mm VENT PIPE TO ROOF
B B
RD SLOPE 0.5% SLOPE 0.5% RD +5.13
WALKING TRACK S.S.L FD 110 mm VENT PIPE TO ROOF
Rf- 15
2000
.5%
PE 0 SLO Toilet
SLO
SLOPE 0.5%
PE 0
+5.13 .5% Rf- 09
S.S.L
.5%
SL
OP
PE 0
.5%
E0
E0
SLO
SLOPE 0.5%
300
.5%
SLO
Open To Below OP
PE
SL Store
5600
5600
0.5%
Rf- 11
2600
Main Stair
Rf- 10 Makeup
Rf- 08
9800
+9.03 +9.28 +9.28
S.S.L F.F.L F.F.L
C Roof Garden C
Rf- 12
2800
2200
2200
Master Bedroom Lobby 110 mm VENT PIPE TO ROOF
Rf- 01 Elevator
Rf- 02
Gr- 15
19000
19000
+9.28
F.F.L
D D
+5.13 Open To Below
Open To Below S.S.L RAIN STACK PIPE Ø 110 T/DN
+5.13
S.S.L
Lobby Hall
1000 100
Rf- 03
SLOPE 0.5%
4600
4900
4900
+9.28
SLO
PE 0 RD
.5%
F.F.L
Ø5
Dressing
0U
Rf- 07
SLOPE 0.5%
.T
%
Roof Garden
%
0.5
+9.28
.5
E
Rf- 12
PE 0
M.BEDROOM Toilet
OP
F.F.L Shower STEEM
SL
2000
SLO
RAIN STACK PIPE Ø 110 T/DN SOIL STACK PIPE Ø 110 T/DN / WET VENT
300
E E
SLO
PE 0
.5%
+9.28
WALKING TRACK 110 mm VENT PIPE TO ROOF +5.13 F.F.L
.5%
SLOPE 0.5%
RD RAIN STACK PIPE Ø 110 F/UP
Rf- 15
PE 0
01 S.S.L Open To Below
2100
SLOPE 0.5%
SLO
A-300-010 Terrace
2400
Rf- 13
4200
4200
A-800-022
01
01
A-300-010
2000
1700
A-800-011
01
F F
2100 5200 1150 2850 1550 2850 550 800 1900 2050 2300 1750 12000
37050
01 02 03 04 05 06 07 08 09 10 11 12 01
13 14
01
A-300-040 A-300-020
01
A-200-010
R
01
01
A-200-010 01
A-300-040
A-300-020
01 02 03 04 05 06 07 08 09 10 11 12 13 14
37050
2100 5200 1150 2850 1550 2850 550 800 1900 2050 2300 1750 12000
02
A-700-011
A +4.10 +5.43 +5.43 +5.43 A
400
1000
01 01
A-300-030 A-300-030
2100
2100
1600
Roof
1000
St- 01 Roof
+14.38 St- 01
B +10.88
T.O.P
+14.38
T.O.P T.O.P B
+5.13 +5.43
+5.13
1800
5600
Terrace
5600
5600
Open To Below + 3.63
SL
St- 03 S.S.L
OP
E
0.5
.5%
SLO
%
%
0.5
PE 0
SLOPE 0.5%
PE 0
+10.88
E
+14.38
OP
SLO
SL
T.O.P
.5%
T.O.P + 3.93
+12.78 T.O.P
Roof S.S.L
+9.03
St- 01
S.S.L
5800
Roof
Rf- 14
C C
+5.43
T.O.P +5.43
2200
2200
2500
T.O.P
19000
19000
D D
300 700 200
+14.38
+4.10 T.O.P
+5.13 +5.13
T.O.P Open To Below
1700
S.S.L Open To Below S.S.L
SLOPE 0.5%
.5%
PE 0
2000
4900
4900
SLO
%
0.5
E
OP
SL
SLO
+14.38 +10.88
3100
PE 0
300
.5%
T.O.P T.O.P
+9.03
+10.88
1300
S.S.L
RD
SLOPE 0.5%
T.O.P
+14.38
E T.O.P
+4.10
E
400
T.O.P
+4.10 RAIN STACKTRACK
WALKING PIPE Ø 110 T/DN
+5.13
T.O.P Rf- 15
01 S.S.L Open To Below +9.03 + 3.93
2100
2000
St- 01
+10.88
4200
4200
T.O.P +10.88
500
+ 3.63
A-800-022
T.O.P
S.S.L 01
01
+3.60
700
T.O.P A-300-010
1700
A-800-011
300 500
01
+4.70 +3.50
+4.10 +4.10 +3.50 +4.10 +3.50 +4.10
T.O.P
F T.O.P T.O.P T.O.P T.O.P T.O.P T.O.P T.O.P
F
300 500 700 500 4250 1450 13450 2300 1600 2800 1800 400 2000 400 1800 2500 300
2100 5200 1150 2850 1550 2850 550 800 1900 2050 2300 1750 12000
37050
01 02 03 04 05 06 07 08 09 10 11 12 01
13 14
01
A-300-040 A-300-020
01
A-200-010