MXL-INST-PULSE
Rev 4
04/2021
MX Series
Pulser Options
INSTRUCTION MANUAL
Standard Pulse Cap Industrial Pulse Cap DIN Pulse Cap
fitted to meter fitted to meter fitted to meter
To the Owner
This manual contains connection and operating
instructions for a selection of Pulse output options.
Please read and retain this instruction manual to
assist you in the operation and maintenance of these
products.
In addition Macnaught offer a comprehensive set of
online support materials to compliment this
instruction manual. You can access the website by
scanning the QR code or visiting the Macnaught
website www.macnaughtflowmeasurement.com.au
Page 1 of 16
INDEX
Types of Switches
Reed Switch Page # 3
Hall Effect Switch Page # 3
Technical Specifications for Reed & Hall Switch Page # 3
Available Configurations for Standard, Industrial and DIN Pulse Caps Page # 3
Circuit Diagram for Pulse Caps Page # 4
Standard Pulse Cap
Description & Wiring Instructions Page # 6
Ordering Code Page # 7
Assembly & Disassembly Page # 7
Industrial Pulse Cap
Description & Wiring Instructions Page # 9
Cable Specifications for Standard/Industrial Pulse Caps Page # 9
Ordering Code Page # 10
Assembly & Disassembly Page # 10
DIN Pulse Cap
Description Page # 12
Ordering Code Page # 12
Accessories Page # 12
Connector Details Page # 13
Page 2 of 16
Types of Switches
Reed Switch
Reed Switch: Reed Switch is a 2-wire device which
triggers by magnet inside the rotors as they spin. To
maximise the life of the reed switch, the pulse board
comes equipped with a 1k8Ω current limiting resistor
in series.
Hall Effect Switch
Hall Effect Switch: Hall Effect switch is a 3-wire
device which triggers by south pole of the magnet
inside the rotors as they spin. This switch is NPN
type. The switch circuit is equipped with a 4k7Ω pull
-up resistor between signal and supply.
Technical Specifications for Reed & Hall Switches
Output Signals Standard Pulse Meter 2 x Digital (Square Wave)
Current Maximum 500mA
Reed Switch
Voltage Maximum 30V DC
(Mechanical Sensor)
1
Contact Rating Maximum 10W
Maximum Supply Current 7.5mA
Maximum Output Current 25mA
Hall Effect Switch
(Electronic Sensor) Operating Voltage 4.5V to 24V DC
Output Type Open-Collector NPN
1.Contact rating maximum is 10W. Neither current nor voltage maximums should be exceeded in achieving this.
Available Configurations for Standard, Industrial and DIN Pulse Caps
The Below 3 configurations are available with Standard, Industrial and DIN pulse caps
Configuration 1 Reed and Hall Effect Sensors
Configuration 2 Dual Hall Effect Sensors
Configuration 3 Dual reed switches
Page 3 of 16
Circuit Diagrams for Available Configurations
Reed/ Hall
Reed/ Reed
Hall/ Hall
Page 4 of 16
Standard Pulse Cap
Page 5 of 16
Standard Pulse Cap Output types A, I, J, K WIRING INSTRUCTIONS
Standard Pulse Cap incorporates the M-LOCK (1/4” turn) mounting system. The housing is made up of
polypropylene with PCB fitted inside.
Standard Pulse Cap PCB
- Standard Pulse Cap Temperature (-40 °C -120 °C)
- IP 67
Page 6 of 16
Standard Pulse Cap Output types A, I, J, K
* MXD-JS generate Quadrature Pulse Output
** MXD-KS has one hall effect high resolution sensor.
Illustration
Standard Pulse Cap fitted to 1” meter
Assembly/Disassembly
1. Rotate the pulse cap 90° anticlockwise to disassemble
2. Pull the cap away from body
1 2
Place pulse cap onto the body and rotate 90° clockwise to reassemble
No Tool required to assemble/dissemble
Page 7 of 16
Industrial Pulse Cap
Page 8 of 16
Industrial Pulse Cap Output Type (MXD-xCx-xx) WIRING INSTRUCTIONS
Industrial Pulse Cap is fixed to the flow meter and
does not incorporate M-lock feature. It comes with
Conduit Entry to facilitate customers for own wiring.
Illustration
PCB
* MXD-xCx-HH generate Quadrature Pulse Output
- Industrial Pulse Cap Temperature (-25 °C -120 °C)
- IP 67
Cable Specifications for Standard/Industrial Pulse Cap
Minimal cable specification recommended for wire:
5 core, 24 AWG each
drain wire AND shielding/ copper braiding
Temperature rating: -20 - 80 °C
Voltage rating: 300 V
- Maximum cable length should not exceed 60 metres.
- If cable is extended and/or longer than 10m, it is highly recommended to use 24V power supply for Hall
Switch and reed switch.
Page 9 of 16
Industrial Pulse Cap Output Type (MXD-xCx-xx)
Illustration
Industrial Pulse Cap fitted to 1” meter
* Industrial Pulse Cap Housing material “Aluminium” to be fitted to flow meter having Aluminium Body
* Industrial Pulse Cap Housing material “SS 316” to be fitted to flow meter having SS 316 Body
The Industrial Pulse Cap comprises of 3 major
components.
Pulser Cap Screws
1. Industrial Pulse Cap
2. PCB (sensor board)
3. Secure Base Plate
Pulser Cap
In order to access the PCB, or for the removal/
replacement of the complete Pulser Module, the
Pulser Cap Gasket
Following procedure applies.
PCB screws Disassembly/Reassembly
PCB Circlip Remove the 4 socket head cap screws holding
the Industrial Pulse Cap to the Base Plate.
Take care not to lose the gasket.
Base Plate
Lift the Pulse Cap to expose the terminal block
for the connection/disconnection of the signal
cables.
The PCB can be removed by loosening the
two screws securing it to the Base Plate.
Note: It is not necessary to remove the PCB if
the objective is to remove the complete base
plate (see next step)
To separate the Base Plate from the Flow
meter body, remove the stainless steel Cir-
Flowmeter clip.
Reassemble by reversing the above sequence.
Page 10 of 16
DIN Pulse Cap
Page 11 of 16
DIN Pulse Module Output Type (MXD-xx)
DIN Pulse Module incorporates the M-LOCK (¼ turn) mounting system. It provides a locking facility for added
security against unauthorised removal. A locking screw is supplied with DIN pulse cap to accomplish the job by
fitting module to the flow meter using M-lock feature and replacing the existing screw with locking screw.
During initial installation of the locking screw, the screw will need to pierce the bottom of the pulser.
This will enable the screw to „lock‟ into the plastic cam that is fixed to the flow meter.
The available options are:
DIN Module with 1 x Reed and 1 x Hall effect sensor (MXD-RH)
DIN Module with Dual Hall Effect sensors (MXD-HH)
DIN Module with Dual Reed Switches (MXD-RR)
Illustration
The DIN Pulse Modules accommodates the choice of either a field mountable connector facility, or a fixed (M12)
connection cable.
M12 DIN plug and socket complete with 5 core cable.
Field attachable socket with 5 position screw terminals
M12 DIN cable Field attachable socket/connector
Cable Length Part Number
1.5 Meters MXD-C1.5 Part number: MXD-CF
5 Meters MXD-C5
10 Meters MXD-C10
Page 12 of 16
DIN Pulse Module Output Type (MXD-xx)
- DIN Pulse Cap Temperature (-25 °C -120 °C)
- IP 67
Cable Colour Reed / Hall Module Dual Reed Module Dual Hall Module
1 Brown HE Supply (VCC) N/A HE Supply (VCC)
2 White HE Signal (V out) Reed Signal 1 HE Signal 1 (V out)
3 Blue HE Ground Reed Ground 1 HE Ground
4 Black Reed (Signal) Reed Signal 2 HE Signal 2 (V out)
5 Green-Yellow Reed (Ground) Reed Ground 2 N/A
M12 DIN Female Cable Connector M12 Field Connector
General General
Connector M12 (right angle)
Connector M12
Standards / regulations IEC 61076-2-101
Technical Specifications (Plug and socket) Standards / regulations IEC 61076-2-101
Number of positions 5
Technical Specifications
Protection IP67
Material of body TPU (thermoplastic polyurethane) Number of positions 5
Rated voltage / current 60v / 4A
Protection IP67
Contact resistance Max 5 mΩ
Ambient temperature (plug and socket) -25°C - 90°C Conductor cross section 0.25mm² - 0.75mm²
Technical Specifications (cable) Material of body PTB
Core Number 5 core
Core colours brown, white, blue, black, green-yellow Sealing material NBR (nitrile rubber)
Cable material PUR (polyurethane)
Ambient temperature -25°C - 85°C (plug and socket)
Conductor cross section 5 x 0.34mm² (signal lines)
Rated voltage / current 60v / 4A Rated voltage / current 60v / 4A
Ambient Temperature (operation) -25°C - 80°C (cable, fixed installation)
Cable resistant to acids, alkaline solutions and salt water
Page 13 of 16
NOTES
Page 14 of 16
WEEE Directive - Waste Electrical and Electronic Equipment
The WEEE Directive requires the recycling of waste electrical and electronic equip-
ment in the European Union.
Whilst the WEEE Directive does not apply to some of Macnaught‟s products, we sup-
port its policy and ask you to be aware of how to dispose of this product.
The crossed out wheelie bin symbol illustrated and found on our products signifies that
this product should not be disposed of in general waste or landfill.
Please contact your local dealer national distributor or Macnaught Technical Services
for information on product disposal.
Page 15 of 16
Macnaught USA Inc – Serves the Americas
614 S Ware BLVD
Tampa, Fl 33619
( 813) 628-5506
[email protected]
www.macnaughtusa.com
Page 16 of 16