This 7-page document is a data sheet for an uninterruptible power supply (UPS) system. It provides technical specifications for the key UPS system components, including the static inverter, static transfer switch assembly, rectifier/battery charger, batteries, and average sense voltage. The document requests that vendors furnish this information to describe the UPS system being bid along with a schematic diagram. It will help GAIL India Limited evaluate UPS system proposals.

Uploaded by

Prakash Sinha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
135 views7 pages

Data Sheet - UPS System

This 7-page document is a data sheet for an uninterruptible power supply (UPS) system. It provides technical specifications for the key UPS system components, including the static inverter, static transfer switch assembly, rectifier/battery charger, batteries, and average sense voltage. The document requests that vendors furnish this information to describe the UPS system being bid along with a schematic diagram. It will help GAIL India Limited evaluate UPS system proposals.

Uploaded by

Prakash Sinha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

GAIL INDIA LIMITED

DATA SHEET FOR UPS SYSTEM TOTAL SHEETS 07

DOCUMENT NO GAIL-STD-EL-DOC-DS-002

0 30.01.19 ISSUED FOR BID RKS SB SB

REV DATE DESCRIPTION PREP CHK APPR


TABLE OF CONTENTS

1.0 STATIC INVERTER


2.0 STATIC TRANSFER SWITCH ASSEMBLY
3.0 AVERAGE SENSE VOLTAGE
4.0 RECTIFIER / BA TTERY CHARGER
5.0 ACDB
6.0 BATTE RY
7.0 SCHEMATIC DIAGRAM OF UPS SYSTEM TO BE FURNISHED

Document No. Rev


DATA SHEET FOR UPS SYSTEM GAIL-STD-EL-DOC-DS-002 0

SHEET 2 of 7
(TECHANICAL DATA SHEET)

TECHINICAL DATA SHEET (To be furnished by Vendor)

1.0 STATIC INVERTER :

1.1 APPLICATION :
1.2 TYPE :
1.3 DUTY :
1.4 ENCLOSURE :
1.5 COOLING :
1.6 DESIGN AMBIENT TEMPERATURE :
1.7 INVERTER CAPACITY :
1.8 OVER LOAD CAPACITY :
1.9 POWER WALK IN :
1.10 VOLTAGE :
A. INVERTER INPUT
(BATTERY OUTPUT)
B. NOMINAL OUTPUT
1.11 VOLTAGE REGULATION :
A. REGULATION FOR 0-100% LOAD AND :
FOR MIN. TO MAX. DC BATTERY VOLTS
AND FOR BOTH THE CONDITIONS
EXISTING SIMULTANEOUSLY.
B. DYNAMIC RESPONSE OR TRANS. :
VOLTAGE REGULATION AT 100% STEP
LOAD CHANGE (APPLICATION OR
REMOVAL).
C. DYNAMIC RESPONSE OR TRANSIENT :
VOLTAGE REGULATION DURING
TRANSFER OF LOAD TO ALTERNATE
SOURCE.
D. DYNAMIC RESPONSE OR TRANSIENT :
VOLTAGE REGULATION DURING
TRANSFER OF LOAD TO SYSTEM
OUTPUT.
E. DYNAMIC RESPONSE OR TRANSIENT :
VOLTAGE REGULATION AT ABRUPT +
10% CHANGE OF INPUT VOLTAGE.
F. DYNAMIC RESPONSE OR TRANSIENT :
VOLTAGE REGULATION AT FAILURE/
RECOVERY OF COMMERCIAL POWER
G. TRANSIENT RECOVERY OR RESPONSE :
TIME.
H. STEADY STATE :

Document No. Rev


DATA SHEET FOR UPS SYSTEM GAIL-STD-EL-DOC-DS-002 0
SHEET 3 of 7
(0-100% LOAD AT ALL INPUT VOLTAGES
AND ALL POWER FACTORS)
I. TRANSIENT VOLTAGE :
(ON APPLICATION OR REMOVAL OF 100%
LOAD)
J. TIME TO RECOVER FROM TRANSIENT TO :
NORMAL VOLTAGE

K. STEP DOWN BYPASS TRANSFORMER WITH


SOLID STATE VOLTAGE STABILIZER :

L. CELL BOOSTER :

M. HEAT LOSS OF THE SYSTEM :

N. OVERALL EFFICIENCY OF UPS AT :


50% LOAD
75% LOAD
100% LOAD

1.12 WAVE FORM :


A. NOMINAL FREQUENCY :
B. FREQUENCY RANGE FOR ALL :
CONDITIONS OF INPUT SUPPLIES,
LOADS AND TEMP. OCCURING
SIMULTAN. OR IN ANY COMBINATION
(AUTO CONTROLLED)
C. SYNCHRONISTION LIMITS :
(FOR MAINTENANCE OF SYNCHRONISM
BETWEEN INVERTER AND STANDBY A.C.
SOURCE)
D. FIELD ADJUSTMENT RANGE FOR (C) :
ABOVE.
E. TOTAL HARMONIC CONTENT AT 100% :
LINEAR LOAD.
F. HARMONIC CONTEMT FOR ANY SINGLE
HARMONIC
I) AT 100% LINEAR LOAD :
II) AT 100% NON LINEAR LOAD :
G. FREQUENCY ACCURACY FOR INTERNAL :
OSCILLATION.
H. SLEW RATE :
I. OUTPUT VOLTAGE ADJUSTMENT RANGE :
AT RATED LOAD
1.13 RATED OUTPUT CURRENT AT RATED

Document No. Rev


DATA SHEET FOR UPS SYSTEM GAIL-STD-EL-DOC-DS-002 0
SHEET 4 of 7
OUTPUT VOLTAGE WITH CURRENT LIMIT
NOT OPERATING
A. CURRENT :
B. DURATION :
1.14 EFFICIENCY AT FULL LOAD :
(WATT OUTPUT/WATT INPUT)

2.0 STATIC TRANSFER SWITCH ASSEMBLY

2.1 TYPE :
2.2 DUTY :
2.3 ENCLOSURE :
2.4 COOLING :
2.5 AMBIENT TEMPERATURE :
2.6 CAPACITY
A. CONTINUOUS :
B. OVERLOAD :
C. PEAK :
2.7 NORMAL VOLTAGE :
2.8 TRANSIENT VOLTAGE TOLERANCE :
2.9 TRANSFER TIME MILLI SECONDS :

3.0 AVERAGE SENSE VOLTAGE

3.1 INSTANTANEOUS SENSE VOLTAGE :


3.2 ANTI CYCLING CIRCUIT :
3.3 SYNCHRONOUS DISCONNENT RANGE :
3.4 MANUAL BY-PASS SWITCH :
3.5 TYPE :
3.6 VOLTAGE :
3.7 RATED CURRENT :

4.0 RECTIFIER/BATTERY CHARGER

4.1 CHARGER :
4.2 TYPE :
4.3 DUTY :
4.4 ENCLOSURE :
4.5 COOLING :
4.6 AMBIENT TEMPERATURE :
4.7 A.C. INPUT
A. SUPPLY :
B. VOLTAGE VARIATION :
C. FREQUENCY VARIATION :

Document No. Rev


DATA SHEET FOR UPS SYSTEM GAIL-STD-EL-DOC-DS-002 0
SHEET 5 of 7
D. COMBINED VOLT FREQUENCY :
VARIATION
E. SHORT-CIRCUIT LEVEL :
F. SYSTEM EARTHING :

4.8 D.C. OUTPUT :

FEATURES PROVIDED
A. AUTOMATIC VOLTAGE REGULATION :
B. CURRENT LIMITING CIRCUITRY :
C. SMOOTHING FILTER CIRCUIT :
D. SOFT START FEATURE :
E. AUTOMATIC LOAD SHARING DURING :
PARALLEL OPERATION
F. SCR SURGE PROTECTION AND FAST :
ACTING HRC FUSES
G. DC EARTH FAULT ALARM :

5.0 ACDB

INCOMER MCCB (0NE NO.) :


CURRENT RATTING :
MAKE :
VOLTAGE
FAULT LEVEL :
OUTGOING FEEDERS (MCB) :
QUANTITY :
CURRENT RATING :
VOLTAGE :

6.0 BATTERY

6.1 MAKE :
6.2 AH RATING OF BATTERY :
6.3 BATTERY RACK DIMENSION :
6.4 BATTERY CHARGING REQUIREMENT :
(FLOAT/QUICK CHARGE VOLT/CELL)
6.5 TYPE :
6.6 NO. OF BATTERY SET :
6.7 DC VOLTAGE OF BATTERY SET :
6.8 NOMINAL DISCHARGE VOLTAGE :
6.9 CELL END VOLTAGE AT THE END DUTY :
CYCLE
6.10 DUTY CYCLE :
6.11 NUMVER OF CELLS PER BATTERY :

Document No. Rev


DATA SHEET FOR UPS SYSTEM GAIL-STD-EL-DOC-DS-002 0
SHEET 6 of 7
6.12 BATTERY CIRCUIT BREAKER IN :
SEPARATE WALL CUBICLES

7.0 SCHEMATIC DIAGRAM OF UPS SYSTEM TO BE FURNISHED

*****

Document No. Rev


DATA SHEET FOR UPS SYSTEM GAIL-STD-EL-DOC-DS-002 0
SHEET 7 of 7