Dialux 12M 120W Solar Street Light Dialux Report

The document summarizes the lighting performance of a DIALux 120W LED 1x luminaire. Key details include: - Luminaire luminous flux of 17075 lm with a light output ratio of 100.21% and luminous efficacy of 142.3 lm/W. - Light distribution diagrams and asymmetrical light output are provided. - For a street lighting design using this luminaire, metrics like horizontal illuminance, minimum/maximum lux values, and observer luminance are presented to evaluate lighting uniformity and quality. Performance meets standards for the given arrangement.

Uploaded by

luciano añorga
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
583 views14 pages

Dialux 12M 120W Solar Street Light Dialux Report

The document summarizes the lighting performance of a DIALux 120W LED 1x luminaire. Key details include: - Luminaire luminous flux of 17075 lm with a light output ratio of 100.21% and luminous efficacy of 142.3 lm/W. - Light distribution diagrams and asymmetrical light output are provided. - For a street lighting design using this luminaire, metrics like horizontal illuminance, minimum/maximum lux values, and observer luminance are presented to evaluate lighting uniformity and quality. Performance meets standards for the given arrangement.

Uploaded by

luciano añorga
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
  • DIALux Introduction: Provides an introduction to the DIALux 120W LED 1x project with initial polar and linear luminous distribution diagrams.

Project 0 2020/3/6

DIALux 120W LED 1x / DIALux - LED (1x)

DIALux 120W LED 1x

See our luminaire


catalog for an image of
the luminaire.

Light output ratio: 100.21%


Lamp luminous flux: 17040 lm
Luminaire luminous flux: 17075 lm
Power: 120.0 W
Luminous efficacy: 142.3 lm/W

Luminous emittance 1 / Polar LDC


105° 105°

90° 90°

75° 75°

60° 60°

450

45° 45°

600

750

30° 15° 0° 15° 30°

cd/klm η = 100%
C0 - C180 C90 - C270

Page 1
Project 0 2020/3/6

DIALux 120W LED 1x / DIALux - LED (1x)

Luminous emittance 1 / Linear LDC


600

500

400

300

200

100

90.0° 67.5° 45.0° 22.5° 0.0° 22.5° 45.0° 67.5° 90.0°


cd/klm η = 100%
C0 - C180 C90 - C270

It is not possible to generate a cone diagram, as the light distribution


is asymmetrical.

Page 2
Project 0 2020/3/6

DIALux 120W LED 1x / DIALux - LED (1x)

Luminous emittance 1 / Luminance diagram


C225 C180 C135

C270 C90

800000

1200000

1600000

C315 C0 C45

cd/m²
g = 65.0° g = 75.0° g = 85.0°

It is not possible to generate a UGR diagram, as the light distribution


is asymmetrical.

Page 3
Project 0 2020/3/6

Street 1: Alternative 1 / Planning results

Street 1 according to EN 13201:2015 DIALux 120W LED

Roadway 1 (M5), 300.00 m²


Tarmac: CIE R2, q0: 0.070

10.00 m

30.00 m

Lamp: 1x
Results for valuation fields Luminous flux (luminaire): 17074.50 lm
Light loss factor: 0.67 Luminous flux (lamp): 17039.50 lm

Roadway 1 (M5) Operating Hours

Lm Uo TI [%] EIR Ul 4000 h: 100.0 %, 120.0 W


[cd/m²] ≥ 0.35 ≤ 15 ≥ 0.30 W/km: 3960.0
≥ 0.50
Arrangement: single side top
0.56 0.35 2 0.75 * 0.23
Pole distance: 30.000 m
Boom inclination (3): 15.0°
* Informative, not part of the valuation
Boom length (4): 1.500 m
Results for energy efficiency indicators Light centre height (1): 12.000 m
Power density indicator (Dp) 0.037 W/lxm² Light overhang (2): 1.500 m
Energy consumption density
Arrangement: LED (480.0 kWh/yr) 1.6 kWh/m² yr

ULR: 0.03
ULOR: 0.03
Maximum luminous intensities
at 70° and above 522 cd/klm *
at 80° and above 444 cd/klm *
at 90° and above 38.5 cd/klm *
Luminous intensity class: /
Any direction forming the specified angle from the downward
vertical, with the luminaire installed for use.
* Luminous intensity values in [cd/klm] for calculating luminous
intensity class refer to the output flux of the luminaire, according
EN 13201:2015.
Arrangement complies with glare index class D.3

Page 4
Project 0 2020/3/6

Street 1: Alternative 1 / Roadway 1 (M5) / Results summary

Roadway 1 (M5)
Light loss factor: 0.67
Grid: 10 x 6 Points

Lm Uo TI [%] EIR Ul
[cd/m²] ≥ 0.35 ≤ 15 ≥ 0.30
≥ 0.50
0.56 0.35 2 0.75 * 0.23

* Informative, not part of the valuation

Assigned observer (2):

Observer Position [m] Lm Uo Ul TI [%]


[cd/m²] ≥ 0.35 ≤ 15
≥ 0.50
Observer 1 (-60.000, 2.500, 1.500) 0.58 0.35 0.31 2
Observer 2 (-60.000, 7.500, 1.500) 0.56 0.35 0.23 2

Page 5
Project 0 2020/3/6

Street 1: Alternative 1 / Roadway 1 (M5) / Table

Roadway 1 (M5)
Horizontal illuminance [lx]
9.167 19.5 12.3 6.82 3.90 2.57 4.57 10.9 16.6 21.1 23.7
7.500 18.9 11.9 7.08 4.03 2.75 5.21 11.1 16.0 20.1 23.0
5.833 17.9 11.4 6.82 3.96 2.81 5.39 10.7 15.0 18.7 21.1
4.167 16.3 10.6 6.54 3.99 3.31 5.86 10.3 14.0 17.1 19.1
2.500 14.6 9.40 6.10 4.02 3.81 6.21 9.71 12.7 15.4 17.0
0.833 12.8 8.87 5.47 3.90 4.05 6.18 8.91 11.4 13.8 14.8
m 1.500 4.500 7.500 10.500 13.500 16.500 19.500 22.500 25.500 28.500

Grid: 10 x 6 Points

Em [lx] Emin [lx] Emax [lx] g1 g2


10.9 2.57 23.7 0.236 0.108

Page 6
Project 0 2020/3/6

Street 1: Alternative 1 / Roadway 1 (M5) / Table

Observer 1

Luminance with dry roadway [cd/m²]


9.167 0.75 0.48 0.30 0.21 0.20 0.45 0.90 1.08 1.08 1.01
7.500 0.75 0.48 0.33 0.24 0.25 0.55 0.95 1.07 1.06 1.00
5.833 0.73 0.48 0.33 0.24 0.26 0.56 0.90 1.00 0.99 0.91
4.167 0.66 0.45 0.32 0.23 0.27 0.53 0.81 0.86 0.84 0.79
2.500 0.58 0.40 0.28 0.21 0.27 0.47 0.67 0.69 0.70 0.70
0.833 0.52 0.38 0.25 0.21 0.27 0.38 0.52 0.56 0.60 0.61
m 1.500 4.500 7.500 10.500 13.500 16.500 19.500 22.500 25.500 28.500

Grid: 10 x 6 Points

Lm [cd/m²] Lmin [cd/m²] Lmax [cd/m²] g1 g2


0.58 0.20 1.08 0.350 0.187

Luminance with new lamp [cd/m²]


9.167 1.12 0.72 0.46 0.32 0.30 0.67 1.34 1.61 1.61 1.50
7.500 1.12 0.72 0.49 0.35 0.37 0.82 1.42 1.60 1.58 1.50
5.833 1.10 0.71 0.50 0.36 0.39 0.83 1.34 1.49 1.47 1.35
4.167 0.98 0.67 0.47 0.34 0.41 0.79 1.21 1.28 1.25 1.18
2.500 0.87 0.60 0.42 0.32 0.41 0.70 0.99 1.04 1.05 1.04
0.833 0.78 0.56 0.37 0.31 0.40 0.57 0.78 0.83 0.89 0.91
m 1.500 4.500 7.500 10.500 13.500 16.500 19.500 22.500 25.500 28.500

Grid: 10 x 6 Points

Lm [cd/m²] Lmin [cd/m²] Lmax [cd/m²] g1 g2


0.86 0.30 1.61 0.350 0.187

Page 7
Project 0 2020/3/6

Street 1: Alternative 1 / Roadway 1 (M5) / Table

Observer 2

Luminance with dry roadway [cd/m²]


9.167 0.77 0.50 0.32 0.23 0.22 0.48 0.93 1.10 1.10 1.02
7.500 0.76 0.49 0.34 0.24 0.25 0.55 0.95 1.07 1.06 1.01
5.833 0.72 0.46 0.31 0.22 0.23 0.51 0.84 0.97 0.96 0.88
4.167 0.64 0.43 0.29 0.20 0.24 0.48 0.75 0.81 0.80 0.77
2.500 0.57 0.39 0.27 0.20 0.26 0.42 0.62 0.65 0.68 0.69
0.833 0.52 0.37 0.24 0.20 0.25 0.35 0.48 0.54 0.59 0.61
m 1.500 4.500 7.500 10.500 13.500 16.500 19.500 22.500 25.500 28.500

Grid: 10 x 6 Points

Lm [cd/m²] Lmin [cd/m²] Lmax [cd/m²] g1 g2


0.56 0.20 1.10 0.350 0.179

Luminance with new lamp [cd/m²]


9.167 1.15 0.74 0.48 0.34 0.33 0.71 1.39 1.65 1.64 1.53
7.500 1.13 0.73 0.51 0.36 0.38 0.82 1.42 1.60 1.58 1.50
5.833 1.07 0.68 0.47 0.33 0.35 0.76 1.26 1.44 1.44 1.32
4.167 0.95 0.64 0.44 0.30 0.36 0.72 1.11 1.20 1.19 1.15
2.500 0.85 0.58 0.41 0.30 0.38 0.63 0.92 0.97 1.02 1.03
0.833 0.77 0.55 0.36 0.29 0.37 0.52 0.72 0.81 0.88 0.90
m 1.500 4.500 7.500 10.500 13.500 16.500 19.500 22.500 25.500 28.500

Grid: 10 x 6 Points

Lm [cd/m²] Lmin [cd/m²] Lmax [cd/m²] g1 g2


0.84 0.29 1.65 0.350 0.179

Page 8
Project 0 2020/3/6

Street 1: Alternative 1 / Roadway 1 (M5) / Isolines

Roadway 1 (M5)
Light loss factor: 0.67
Grid: 10 x 6 Points

Lm Uo TI [%] EIR Ul
[cd/m²] ≥ 0.35 ≤ 15 ≥ 0.30
≥ 0.50
0.56 0.35 2 0.75 * 0.23

* Informative, not part of the valuation

Horizontal illuminance

10.00 m

30.00 m

Observer 1

Luminance with dry roadway

10.00 m

30.00 m

Page 9
Project 0 2020/3/6

Street 1: Alternative 1 / Roadway 1 (M5) / Isolines

Luminance with new lamp

10.00 m

30.00 m

Observer 2

Luminance with dry roadway

10.00 m

30.00 m

Page 10
Project 0 2020/3/6

Street 1: Alternative 1 / Roadway 1 (M5) / Isolines

Luminance with new lamp

10.00 m

30.00 m

Page 11
Project 0 2020/3/6

Street 1: Alternative 1 / Roadway 1 (M5) / Value chart

Roadway 1 (M5)
Light loss factor: 0.67
Grid: 10 x 6 Points

Lm Uo TI [%] EIR Ul
[cd/m²] ≥ 0.35 ≤ 15 ≥ 0.30
≥ 0.50
0.56 0.35 2 0.75 * 0.23

* Informative, not part of the valuation

Horizontal illuminance

10.00 m

30.00 m

Observer 1

Luminance with dry roadway

10.00 m

30.00 m

Page 12
Project 0 2020/3/6

Street 1: Alternative 1 / Roadway 1 (M5) / Value chart

Luminance with new lamp

10.00 m

30.00 m

Observer 2

Luminance with dry roadway

10.00 m

30.00 m

Page 13
Project 0 2020/3/6

Street 1: Alternative 1 / Roadway 1 (M5) / Value chart

Luminance with new lamp

10.00 m

30.00 m

Page 14

You might also like