Project 0 2020/3/6
DIALux 120W LED 1x / DIALux - LED (1x)
DIALux 120W LED 1x
See our luminaire
catalog for an image of
the luminaire.
Light output ratio: 100.21%
Lamp luminous flux: 17040 lm
Luminaire luminous flux: 17075 lm
Power: 120.0 W
Luminous efficacy: 142.3 lm/W
Luminous emittance 1 / Polar LDC
105° 105°
90° 90°
75° 75°
60° 60°
450
45° 45°
600
750
30° 15° 0° 15° 30°
cd/klm η = 100%
C0 - C180 C90 - C270
Page 1
Project 0 2020/3/6
DIALux 120W LED 1x / DIALux - LED (1x)
Luminous emittance 1 / Linear LDC
600
500
400
300
200
100
90.0° 67.5° 45.0° 22.5° 0.0° 22.5° 45.0° 67.5° 90.0°
cd/klm η = 100%
C0 - C180 C90 - C270
It is not possible to generate a cone diagram, as the light distribution
is asymmetrical.
Page 2
Project 0 2020/3/6
DIALux 120W LED 1x / DIALux - LED (1x)
Luminous emittance 1 / Luminance diagram
C225 C180 C135
C270 C90
800000
1200000
1600000
C315 C0 C45
cd/m²
g = 65.0° g = 75.0° g = 85.0°
It is not possible to generate a UGR diagram, as the light distribution
is asymmetrical.
Page 3
Project 0 2020/3/6
Street 1: Alternative 1 / Planning results
Street 1 according to EN 13201:2015 DIALux 120W LED
Roadway 1 (M5), 300.00 m²
Tarmac: CIE R2, q0: 0.070
10.00 m
30.00 m
Lamp: 1x
Results for valuation fields Luminous flux (luminaire): 17074.50 lm
Light loss factor: 0.67 Luminous flux (lamp): 17039.50 lm
Roadway 1 (M5) Operating Hours
Lm Uo TI [%] EIR Ul 4000 h: 100.0 %, 120.0 W
[cd/m²] ≥ 0.35 ≤ 15 ≥ 0.30 W/km: 3960.0
≥ 0.50
Arrangement: single side top
0.56 0.35 2 0.75 * 0.23
Pole distance: 30.000 m
Boom inclination (3): 15.0°
* Informative, not part of the valuation
Boom length (4): 1.500 m
Results for energy efficiency indicators Light centre height (1): 12.000 m
Power density indicator (Dp) 0.037 W/lxm² Light overhang (2): 1.500 m
Energy consumption density
Arrangement: LED (480.0 kWh/yr) 1.6 kWh/m² yr
ULR: 0.03
ULOR: 0.03
Maximum luminous intensities
at 70° and above 522 cd/klm *
at 80° and above 444 cd/klm *
at 90° and above 38.5 cd/klm *
Luminous intensity class: /
Any direction forming the specified angle from the downward
vertical, with the luminaire installed for use.
* Luminous intensity values in [cd/klm] for calculating luminous
intensity class refer to the output flux of the luminaire, according
EN 13201:2015.
Arrangement complies with glare index class D.3
Page 4
Project 0 2020/3/6
Street 1: Alternative 1 / Roadway 1 (M5) / Results summary
Roadway 1 (M5)
Light loss factor: 0.67
Grid: 10 x 6 Points
Lm Uo TI [%] EIR Ul
[cd/m²] ≥ 0.35 ≤ 15 ≥ 0.30
≥ 0.50
0.56 0.35 2 0.75 * 0.23
* Informative, not part of the valuation
Assigned observer (2):
Observer Position [m] Lm Uo Ul TI [%]
[cd/m²] ≥ 0.35 ≤ 15
≥ 0.50
Observer 1 (-60.000, 2.500, 1.500) 0.58 0.35 0.31 2
Observer 2 (-60.000, 7.500, 1.500) 0.56 0.35 0.23 2
Page 5
Project 0 2020/3/6
Street 1: Alternative 1 / Roadway 1 (M5) / Table
Roadway 1 (M5)
Horizontal illuminance [lx]
9.167 19.5 12.3 6.82 3.90 2.57 4.57 10.9 16.6 21.1 23.7
7.500 18.9 11.9 7.08 4.03 2.75 5.21 11.1 16.0 20.1 23.0
5.833 17.9 11.4 6.82 3.96 2.81 5.39 10.7 15.0 18.7 21.1
4.167 16.3 10.6 6.54 3.99 3.31 5.86 10.3 14.0 17.1 19.1
2.500 14.6 9.40 6.10 4.02 3.81 6.21 9.71 12.7 15.4 17.0
0.833 12.8 8.87 5.47 3.90 4.05 6.18 8.91 11.4 13.8 14.8
m 1.500 4.500 7.500 10.500 13.500 16.500 19.500 22.500 25.500 28.500
Grid: 10 x 6 Points
Em [lx] Emin [lx] Emax [lx] g1 g2
10.9 2.57 23.7 0.236 0.108
Page 6
Project 0 2020/3/6
Street 1: Alternative 1 / Roadway 1 (M5) / Table
Observer 1
Luminance with dry roadway [cd/m²]
9.167 0.75 0.48 0.30 0.21 0.20 0.45 0.90 1.08 1.08 1.01
7.500 0.75 0.48 0.33 0.24 0.25 0.55 0.95 1.07 1.06 1.00
5.833 0.73 0.48 0.33 0.24 0.26 0.56 0.90 1.00 0.99 0.91
4.167 0.66 0.45 0.32 0.23 0.27 0.53 0.81 0.86 0.84 0.79
2.500 0.58 0.40 0.28 0.21 0.27 0.47 0.67 0.69 0.70 0.70
0.833 0.52 0.38 0.25 0.21 0.27 0.38 0.52 0.56 0.60 0.61
m 1.500 4.500 7.500 10.500 13.500 16.500 19.500 22.500 25.500 28.500
Grid: 10 x 6 Points
Lm [cd/m²] Lmin [cd/m²] Lmax [cd/m²] g1 g2
0.58 0.20 1.08 0.350 0.187
Luminance with new lamp [cd/m²]
9.167 1.12 0.72 0.46 0.32 0.30 0.67 1.34 1.61 1.61 1.50
7.500 1.12 0.72 0.49 0.35 0.37 0.82 1.42 1.60 1.58 1.50
5.833 1.10 0.71 0.50 0.36 0.39 0.83 1.34 1.49 1.47 1.35
4.167 0.98 0.67 0.47 0.34 0.41 0.79 1.21 1.28 1.25 1.18
2.500 0.87 0.60 0.42 0.32 0.41 0.70 0.99 1.04 1.05 1.04
0.833 0.78 0.56 0.37 0.31 0.40 0.57 0.78 0.83 0.89 0.91
m 1.500 4.500 7.500 10.500 13.500 16.500 19.500 22.500 25.500 28.500
Grid: 10 x 6 Points
Lm [cd/m²] Lmin [cd/m²] Lmax [cd/m²] g1 g2
0.86 0.30 1.61 0.350 0.187
Page 7
Project 0 2020/3/6
Street 1: Alternative 1 / Roadway 1 (M5) / Table
Observer 2
Luminance with dry roadway [cd/m²]
9.167 0.77 0.50 0.32 0.23 0.22 0.48 0.93 1.10 1.10 1.02
7.500 0.76 0.49 0.34 0.24 0.25 0.55 0.95 1.07 1.06 1.01
5.833 0.72 0.46 0.31 0.22 0.23 0.51 0.84 0.97 0.96 0.88
4.167 0.64 0.43 0.29 0.20 0.24 0.48 0.75 0.81 0.80 0.77
2.500 0.57 0.39 0.27 0.20 0.26 0.42 0.62 0.65 0.68 0.69
0.833 0.52 0.37 0.24 0.20 0.25 0.35 0.48 0.54 0.59 0.61
m 1.500 4.500 7.500 10.500 13.500 16.500 19.500 22.500 25.500 28.500
Grid: 10 x 6 Points
Lm [cd/m²] Lmin [cd/m²] Lmax [cd/m²] g1 g2
0.56 0.20 1.10 0.350 0.179
Luminance with new lamp [cd/m²]
9.167 1.15 0.74 0.48 0.34 0.33 0.71 1.39 1.65 1.64 1.53
7.500 1.13 0.73 0.51 0.36 0.38 0.82 1.42 1.60 1.58 1.50
5.833 1.07 0.68 0.47 0.33 0.35 0.76 1.26 1.44 1.44 1.32
4.167 0.95 0.64 0.44 0.30 0.36 0.72 1.11 1.20 1.19 1.15
2.500 0.85 0.58 0.41 0.30 0.38 0.63 0.92 0.97 1.02 1.03
0.833 0.77 0.55 0.36 0.29 0.37 0.52 0.72 0.81 0.88 0.90
m 1.500 4.500 7.500 10.500 13.500 16.500 19.500 22.500 25.500 28.500
Grid: 10 x 6 Points
Lm [cd/m²] Lmin [cd/m²] Lmax [cd/m²] g1 g2
0.84 0.29 1.65 0.350 0.179
Page 8
Project 0 2020/3/6
Street 1: Alternative 1 / Roadway 1 (M5) / Isolines
Roadway 1 (M5)
Light loss factor: 0.67
Grid: 10 x 6 Points
Lm Uo TI [%] EIR Ul
[cd/m²] ≥ 0.35 ≤ 15 ≥ 0.30
≥ 0.50
0.56 0.35 2 0.75 * 0.23
* Informative, not part of the valuation
Horizontal illuminance
10.00 m
30.00 m
Observer 1
Luminance with dry roadway
10.00 m
30.00 m
Page 9
Project 0 2020/3/6
Street 1: Alternative 1 / Roadway 1 (M5) / Isolines
Luminance with new lamp
10.00 m
30.00 m
Observer 2
Luminance with dry roadway
10.00 m
30.00 m
Page 10
Project 0 2020/3/6
Street 1: Alternative 1 / Roadway 1 (M5) / Isolines
Luminance with new lamp
10.00 m
30.00 m
Page 11
Project 0 2020/3/6
Street 1: Alternative 1 / Roadway 1 (M5) / Value chart
Roadway 1 (M5)
Light loss factor: 0.67
Grid: 10 x 6 Points
Lm Uo TI [%] EIR Ul
[cd/m²] ≥ 0.35 ≤ 15 ≥ 0.30
≥ 0.50
0.56 0.35 2 0.75 * 0.23
* Informative, not part of the valuation
Horizontal illuminance
10.00 m
30.00 m
Observer 1
Luminance with dry roadway
10.00 m
30.00 m
Page 12
Project 0 2020/3/6
Street 1: Alternative 1 / Roadway 1 (M5) / Value chart
Luminance with new lamp
10.00 m
30.00 m
Observer 2
Luminance with dry roadway
10.00 m
30.00 m
Page 13
Project 0 2020/3/6
Street 1: Alternative 1 / Roadway 1 (M5) / Value chart
Luminance with new lamp
10.00 m
30.00 m
Page 14